891 resultados para electric power generation


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the scope of the discussions about microgeneration (and microgrids), the avoided electrical losses are often pointed out as an important value to be credited to those entities. Therefore, methods to assess the impact of microgeneration on losses must be developed in order to support the definition of a suitable regulatory framework for the economic integration of microgeneration on distribution networks. This paper presents an analytical method to quantify the value of avoided losses that microgeneration may produce on LV networks. Intervals of expected avoided losses are used to account for the variation of avoided losses due to the number, size and location of microgenerators, as well as for the kind of load distribution on LV networks.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Hydroelectric systems are well-known for large scale power generation. However, there are virtually no studies on energy harvesting with these systems to produce tens or hundreds of milliwatts. The goal of this work was to study which design parameters from large-scale systems can be applied to small-scale systems. Two types of hydro turbines were evaluated. The first one was a Pelton turbine which is suitable for high heads and low flow rates. The second one was a propeller turbine used for low heads and high flow rates. Several turbine geometries and nozzle diameters were tested for the Pelton system. For the propeller, a three-bladed turbine was tested for different heads and draft tubes. The mechanical power provided by these turbines was measured to evaluate the range of efficiencies of these systems. A small three-phase generator was developed for coupling with the turbines in order to evaluate the generated electric power. Selected turbines were used to test battery charging with hydroelectric systems and a comparison between several efficiencies of the systems was made. Keywords

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La presente investigación pretendió incorporar el uso intensivo de TIC en los procedimientos establecidos y necesarios en los procesos de generación, distribución y control de la energía, lo que se expresa en un manual para el sistema de gestión humana de la organización analizada. La investigación partió de un levantamiento de un estado del arte, continuó con la realización de un análisis de actitudes y aptitudes de los colaboradores, basado en propuestas teóricas y mejores prácticas existentes del medio, y, por último, concluyó con un manual de gestión humana en el que se indican las competencias en los diferentes perfiles de la organización para el uso de TIC y su aplicación, con el propósito de alinearse con las perspectivas y objetivos de la organización analizada al tener como base la perdurabilidad y la competitividad de la misma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Waterfalls attract tourists because they are aesthetically appealing landscape features that are not part of everyday experience. It is generally understood that falls are usually seen at their best when there is a copious flow of water, especially after heavy rain. Guidebooks often contain this observation when referring to waterfalls, sometimes warning readers that the flow may be severely reduced during dry periods. Indeed, many visitors are disappointed when they see falls at such times. Some are saddened when the discharge of a waterfall has been depleted by the abstraction of water upstream for power generation or other purposes. While, for those in search of the Sublime or merely the superlative, size is often important, small waterfalls can give great pleasure to lovers of landscape beauty. According to guidebooks, however, even these falls are usually best seen after rain. Drawing on tourist and travel literature and personal journals from the eighteenth century to the present, and with reference to examples from different parts of the world, this paper discusses the importance of discharge in the tourist experience of waterfalls.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study investigates the short-run dynamics and long-run equilibrium relationship between residential electricity demand and factors influencing demand - per capita income, price of electricity, price of kerosene oil and price of liquefied petroleum gas - using annual data for Sri Lanka for the period, 1960-2007. The study uses unit root, cointegration and error-correction models. The long-run demand elasticities of income, own price and price of kerosene oil (substitute) were estimated to be 0.78, - 0.62, and 0.14 respectively. The short-run elasticities for the same variables were estimated to be 032, - 0.16 and 0.10 respectively. Liquefied petroleum (LP) gas is a substitute for electricity only in the short-run with an elasticity 0.09. The main findings of the paper support the following (1) increasing the price of electricity is not the most effective tool to reduce electricity consumption (2) existing subsidies on electricity consumption can be removed without reducing government revenue (3) the long-run income elasticity of demand shows that any future increase in household incomes is likely to significantly increase the demand for electricity and(4) any power generation plans which consider only current per capita consumption and population growth should be revised taking into account the potential future income increases in order to avoid power shortages ill the country.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent months the extremes of Australia’s weather have affected, killed a good number of people and millions of dollars lost. Contrary to a manned aircraft or a helicopter; which have restricted air time, a UAS or a group of UAS could provide 24 hours coverage of the disaster area and be instrumented with infrared cameras to locate distressed people and relay information to emergency services. The solar powered UAV is capable of carrying a 0.25Kg payload consuming 0.5 watt and fly continuously for at low altitude for 24 hrs ,collect the data and create a special distribution . This system, named Green Falcon, is fully autonomous in navigation and power generation, equipped with solar cells covering its wing, it retrieves energy from the sun in order to supply power to the propulsion system and the control electronics, and charge the battery with the surplus of energy. During the night, the only energy available comes from the battery, which discharges slowly until the next morning when a new cycle starts. The prototype airplane was exhibited at the Melbourne Museum form Nov09 to Feb 2010.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Power transformers are one of the most important and costly equipment in power generation, transmission and distribution systems. Current average age of transformers in Australia is around 25 years and there is a strong economical tendency to use them up to 50 years or more. As the transformers operate, they get degraded due to different loading and environmental operating stressed conditions. In today‘s competitive energy market with the penetration of distributed energy sources, the transformers are stressed more with minimum required maintenance. The modern asset management program tries to increase the usage life time of power transformers with prognostic techniques using condition indicators. In the case of oil filled transformers, condition monitoring methods based on dissolved gas analysis, polarization studies, partial discharge studies, frequency response analysis studies to check the mechanical integrity, IR heat monitoring and other vibration monitoring techniques are in use. In the current research program, studies have been initiated to identify the degradation of insulating materials by the electrical relaxation technique known as dielectrometry. Aging leads to main degradation products like moisture and other oxidized products due to fluctuating thermal and electrical loading. By applying repetitive low frequency high voltage sine wave perturbations in the range of 100 to 200 V peak across available terminals of power transformer, the conductive and polarization parameters of insulation aging are identified. An in-house novel digital instrument is developed to record the low leakage response of repetitive polarization currents in three terminals configuration. The technique is tested with known three transformers of rating 5 kVA or more. The effects of stressing polarization voltage level, polarizing wave shapes and various terminal configurations provide characteristic aging relaxation information. By using different analyses, sensitive parameters of aging are identified and it is presented in this thesis.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper discusses the operating principles and control characteristics of a dynamic voltage restorer (DVR). It is assumed that the source voltages contain interharmonic components in addition to fundamental components. The main aim of the DVR is to produce a set of clean balanced sinusoidal voltages across the load terminals irrespective of unbalance, distortion and voltage sag/swell in the supply voltage. An algorithm has been discussed for extracting fundamental phasor sequence components from the samples of three-phase voltages or current waveforms having integer harmonics and interharmonics. The DVR operation based on extracted components is demonstrated. The switching signal is generated using a deadbeat controller. It has been shown that the DVR is able to compensate these interharmonic components such that the load voltages are perfectly regulated. The DVR operation under deep voltage sag is also discussed. The proposed DVR operation is verified through the computer simulation studies using the MATLAB software package.