801 resultados para early education
Resumo:
This publication is a support and resource document for the "National Action Plan for Promotion, Prevention and Early Intervention for Mental Health 2000". It includes indicators, measurement tools and databases relevant to assessing the implementation of the outcomes and strategies identified in the action plan.
Resumo:
Assesses the status of women in Bangladesh by analysing the dynamics of female participation in labour force and education as well as gender earnings differentials at the macro level. The study finds evidence of growing commercialisation of women’s work in Bangladesh. Although the bulk of the female labour force is engaged in self-employment activities in the rural area or in low-skilled textile and readymade garment industries in the urban area, women’s participation in high-skill and entrepreneurial jobs as well as various decision-making bodies is also on the rise. While the gender wage differentials have been considerably reduced in many industries, in general women tend to be paid less than men. There have been remarkable improvements in women’s educational attainments compared to men. Further, female access to education is found to be highly correlated with overall female labour force participation, and relative to male participation. The overall results are suggestive of an improvement in the status of women in Bangladesh.
Resumo:
Background: Oncogenic Wnt/beta-catenin signaling occurs in numerous types of cancers, but little is known about the role of the Wnt protein family member, WNT-5A, in lip carcinogenesis. The aim of this study was to investigate WNT-5A, beta-catenin, and matrix metalloproteinase (MMP)-3 protein expression in actinic cheilitis (AC), and lip squamous cell carcinoma (LSCC). Methods: Twenty-one cases of AC, and fifty-one cases of LSCC were analyzed, with normal lip mucosa used as a control. Qualitative and semi-quantitative analyses of WNT-5A, beta-catenin, and MMP-3 immunostaining pattern and cellular distribution were performed. Results: WNT-5A was observed in more than 50% of the cells, scattered in all layers of AC, in contrast to the absence of immunostaining in normal lip mucosa. AC presented a higher level of WNT-5A expression than LSCC (P = 0.0289, Fisher test), while MMP-3 immunoexpression was statistically more significant in LSCC than in AC (P = 0.0285, Fisher test). Immunolabeling of beta-catenin protein was differentially distributed between samples; the majority of AC cases (61.90%) demonstrated a membranous-cytoplasmic pattern, while a considerable number of LSCC cases (29.41%) revealed a cytoplasmic pattern, instead of the usual membranous pattern. Conclusions: The present results suggest that WNT-5A may be an important marker during initial events of AC malignant transformation, in which non-canonical and canonical Wnt/beta-catenin signaling pathways could be involved. Additionally, WNT-5A might recruit other events in LSCC, such as MMP-3 protein synthesis, as its presence is increased in established malignant processes without beta-catenin dependency.
Resumo:
Purpose: To evaluate the qualitative and quantitative differences on dental plaque formation on two different roughness titanium implant surfaces, i.e. machined and titanium plasma sprayed, as well as the amount of plaque removal by regular toothbrushing after 72-hour plaque accumulation. Methods: Eight systemically healthy subjects were recruited from the patient pool of a private dental practice. All patients underwent oral hygiene instruction and full mouth prophylaxis. Subsequently, maxillary casts from all patients were obtained and removable 0.7 mm-thick acetate stents without occlusal contact points were fabricated to support four titanium specimens of 4x2x2 mm divided into two groups (machined and plasma sprayed). Subjects were instructed to wear the stents for 72 hours, full time, removing them only during regular oral hygiene. Subsequently, the appliances were immediately repositioned and then the test side was brushed for 20 seconds. At the end of the 72-hour period, the stents were removed and prepared for microbiological analysis. Results: Both machined and plasma sprayed brushed surfaces presented statistically significant fewer bacteria than non-brushed surfaces. Similarly, regarding surface roughness, machined surfaces presented a total number of bacteria significantly smaller than those presented by plasma sprayed surfaces (P< 0.05). Statistically, the non-brushed machined turned surfaces presented a greater amount of Streptoccocus sp. when compared to the brushed machined surfaces. It was concluded that rough surfaces accumulated more dental plaque than polished surfaces. Both brushed surfaces presented less plaque accumulation, however, implant brushing was more effective on machined surfaces. (Am J Dent 2008;21:318-322).
Resumo:
Objectives: The aim of this study was to test the effect of adhesive temperature on the bond strength to dentin (mu TBS) and silver nitrate uptake (SNU) of an ethanol/water (Adper Single Bond 2 [SB]) and an acetone-based (Prime&Bond 2.1 [PB]) etch-and-rinse adhesive system. Methods: The bottles of each adhesive were kept in various temperatures (5 degrees C, 20 degrees C, 37 degrees C and 50 degrees C) for 1 h previously to its application in the occlusal demineralized dentin of 40 molars. Bonded sticks (0.8 mm(2)) were tested in tension (0.5 mm/min) immediately (IM) or after 6 months (6 M) of water storage. Two bonded sticks from each hemi-tooth were immersed in silver nitrate and analyzed by SEM. Data were analyzed by two-way repeated measures ANOVA and Tukey`s test (alpha = 0.05). Results: No significant difference in mu TBS was detected for both adhesives at 5 degrees C and 20 degrees C. The highest bond strength for PB was observed in the 37 degrees C group while for SB it was in the 50 degrees C. Significant reductions of bond strengths were observed for PB at 37 degrees C and SB at 50 degrees C after 6 M of water storage. Silver nitrate deposition was seen in all hybrid layers, irrespective of the group. Lower silver nitrate deposition (water trees) in the adhesive layer was seen for PB and SB at higher temperatures. Conclusions: The heating or refrigeration of the adhesives did not improve their resin-dentin bond resistance to water degradation over time. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Objectives. The aim of this study was to ultrastructurally examine the influence of simvastatin on bone healing in surgically created defects in rat mandibles. Study design. Bone defects 0.8 mm in diameter were created in the buccal aspect of first mandibular molar roots and filled with 2.5% simvastatin gel, while the controls were allowed to heal spontaneously. The rats were humanely killed 7, 9, 11, or 14 days postoperatively, and the specimens were processed for scanning and transmission electron microscopy, as well as for colloidal gold immunolabeling of osteopontin. Results. The regenerated alveolar bone in the simvastatin-treated defects presented smaller marrow spaces, and the collagen fibrils were regularly packed exhibiting a lamellar bone aspect. Osteopontin was present through the bone matrix during the wound healing and alveolar bone regeneration. Conclusion. The present study provides evidence that a single topical application of 2.5% simvastatin gel improves the quality of the new bone and decreases bone resorption. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 170-179)
Resumo:
Purpose: To evaluate early and 24-hour microtensile bond strength (mu TBS) and the degree of conversion (DC) of one representative adhesive system from each of the four current bonding approaches. Methods: 40 human molars were sectioned occluso-gingivally into two halves. Resin composite was bonded incrementally to flat, mid-coronal dentin, using the adhesives Adper Scotchbond MP (MP); Adper Scotchbond 2 (SB); Clearfil SE Bond (SE); and Adper Prompt L-Pop (LP) according to the respective manufacturer`s instructions (n= 10). One half was immediately sectioned into sticks and subjected to mu TBS test. As the sectioning process took approximately 1 hour, the results were designated as 1-hour bond strengths. The other half was stored in distilled water at 37 degrees C for 24 hours before being sectioned and tested. The DC of these systems was measured using Fourier Transform-Raman spectroscopy in three periods: immediately, 1 and 24 hours after polymerization. Data were analyzed with ANOVA and Tukey`s tests. Results: There were no significant differences between the 1-hour and 24-hour bond strengths (P> 0.05), or among the DC measured immediately, 1 hour and 24 hours after polymerization (P> 0.05). However, significant differences were observed among adhesives (P< 0.05). mu TBS values obtained, in MPa (1 hour/24 hour), were: SB (48.6 + 1.3/48.4 + 3.5) = SE (51.9 + 4.7/53.3 +/- 2.9) > MP (35.3 +/- 10.9/38.6 + 6.7) > LP (25.5 + 1.1/26.0 + 1.5). The DC, in percentage (immediately/1 hour/24 hour), were: SE (81/82/87) > MP (79/77/81) > SB (60/63/65) > LP (39/37/42).