926 resultados para digital spiral analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stress distribution of platform switching implants using a photoelastic method. Three models were constructed of the photoelastic resin PL-2, with a single implant and a screw-retained implant-supported prosthesis. These models were Model A, platform 5.0 mm/abutment 4.1 mm; Model B, platform 4.1 mm/abutment 4.1 mm; and Model C, platform 5.00 mm/abutment 5.00 mm. Axial and oblique (45 degrees) loads of 100 N were applied using a Universal Testing Machine (EMIC DL 3000). Images were photographed with a digital camera and visualized with software (AdobePhotoshop) to facilitate the qualitative analysis. The highest stress concentrations were observed at the apical third of the 3 models. With the oblique load, the highest stress concentrations were located at the implant apex, opposite the load application. Stress concentrations decreased in the cervical region of Model A (platform switching), and Models A (platform switching) and C (conventional/wide-diameter) displayed similar stress magnitudes. Finally, Model B (conventional/regular diameter) displayed the highest stress concentrations of the models tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: (1) To evaluate the intraobserver agreement related to image interpretation and (2) to compare the accuracy of 100%, 200% and 400% zoomed digital images in the detection of simulated periodontal bone defects.Methods: Periodontal bone defects were created in 60 pig hemi-mandibles with slow-speed burs 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm and 3.0 mm in diameter. 180 standardized digital radiographs were made using Schick sensor and evaluated at 100%, 200% and 400% zooming. The intraobserver agreement was estimated by Kappa statistic (kappa). For the evaluation of diagnostic accuracy receiver operating characteristic (ROC) analysis was performed followed by chi-square test to compare the areas under ROC curves according to each level of zooming.Results: For 100%, 200% and 400% zooming the intraobserver agreement was moderate (kappa = 0.48, kappa = 0.54 and kappa = 0.43, respectively) and there were similar performances in the discrimination capacity, with ROC areas of 0.8611 (95% CI: 0.7660-0.9562), 0.8600 (95% CI: 0.7659-0.9540), and 0.8368 (95% CI: 0.7346-0.9390), respectively, with no statistical significant differences (chi(2)-test; P = 0.8440).Conclusions: A moderate intraobserver agreement was observed in the classification of periodontal bone defects and the 100%, 200% and 400% zoomed digital images presented similar performances in the detection of periodontal bone defects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. Pixel intensity values (PI) and fractal dimensions (FD) were compared in selected mandibular regions on digital panoramic images of normal, osteopenic, and osteoporotic perimenopausal and postmenopausal women to evaluate their relative efficacies in detecting osteoporotic-associated bone density changes.Study design. Standardized mandibular angle, body, and canine/premolar (C/PM) regions on 54 charge-coupied device (CCD) digital panoramic images of normal and potentially osteoporotic postmenopausal women were analyzed for PI and FD. Lumbar spine and femoral neck dual-energy x-ray absorptiometry QXA) on each patient served as the reference standard examination. Pearson correlation coefficients and analysis of variance (ANOVA) were performed.Results. There was significant correlation among PI measurements (P < 0.01), and no significant correlation between FD. C/PM had significantly lower PI than control C/PM (P = 0.049).Conclusions. Osteoporotic changes in mandibular C/PM cancellous bone were detected in our study population on CCD digital panoramic images by using a robust image analysis paradigm. Future automated application of such image analysis could enable widespread, cost effective screening for osteoporosis in dental settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring.Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring.Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring.Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task.Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing image, calculation, subtract, and new document tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capture web of N. clavipes presents viscous droplets, which play important roles in web mechanics and prey capture. By using scanning and transmission electron microscopy, it was demonstrated that the web droplets are constituted of different chemical environments, provided by the existence both of an aqueous and a lipid layer, which, in turn, present a suspension of tenths of vesicles containing polypeptides and/or tipids. GC/EI-MS Analysis of the contents of these vesicles led to the identification of some saturated fatty acids, such as decanoic acid, undecanoic acid, dodecanoic acid, tetradecanoic acid, octadecanoic acid, and icosanoic acid, while other components were unsaturated fatty acids, such as (Z)-tetradec-9-enoic acid, (Z)-octadec-9-enoic acid, and (Z)-icosa-11-enoic acid; and polyunsaturated fatty acids like (9Z,12Z)-octadeca-9,12-dienoic acid, (9Z,12Z,15Z)-octadeca-9,12,15-trienoic acid, and (11Z,14Z)-icosa-11,14-dienoic acid. Toxic proteins such as calcium-activated proteinase and metalloproteinase jararhagin-like precursor were also identified by using a proteomic approach, indicating the possible involvement of these enzymes in the pre-digestion of spiders' preys web-captured. Apparently, the mixture of fatty acids are relatively toxic to insects by topical application (LD50 64.3 +/- 7.6 ng mg(-1) honeybee), while the proteins alone present no topical effect; however, when injected into the prey-insects, these proteins presented a moderate toxicity (LD50 40.3 +/- 4.8 ng mg(-1) honeybee); the mixture of fatty acids and proteins is very toxic to the preys captured by the web droplets of the viscid spiral of Nephila clavipes when topically applied on them (LD50 14.3 +/- 1.8ng mg(-1) honeybee).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Concern regarding hydrological resources has been a theme of growing importance in Brazil, associating the development of new management policies and maintenance of natural areas related to rivers. An efficient way to maintain natural areas around rivers has been the development of greenways, and some cites have already adopted specific legislation in this respect. Following this growing evolution in the treatment of hydrological resources, this study was carried out to demarcate a greenway along the Corumbatai River in the state of São Paulo, Using multi-criteria analysis in a GIS environment. First, thematic maps were elaborated based on Landsat 7 satellite, aerial photographs and digital topographic base, Supported by field activities. With the use of multi-criteria analysis, for which ad hoe consultations were conducted to attribute weights to the thematic maps, a suitability map was elaborated for the allocation of the greenway. Sites that should be included in the greenway were also selected, such as areas appropriate for leisure activities, and ecologically important areas. Based on the suitability map, a pathway analysis was done, connecting the relevant points of interest, thus generating a greenway that runs along the Corumbatai River, with the aim of contributing to the conservation of this important hydrological resource. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reliable spectral analysis is only achieved if the spectrum is thoroughly investigated in regard to all hidden and overlapped peaks. This paper describes the steps undertaken to find and separate such peaks in the range of 3000 to 4000 cm(-1) in the case of three different infrared absorption spectra of the glass surface of hydrolyzed silica optical fibers. Peak finding was done by the analysis of the second and fourth derivatives of the digital data, coupled with the available knowledge of infrared spectroscopy of silica-water interaction in the investigated range. Peak separation was accomplished by curve fitting with four different models. The model with the best fit was described by a sum of pure Gaussian peaks. Shoulder limit and detection limit maps were used to validate the revealed spectral features.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar a influência do cetoprofeno sobre o processo de reparação óssea em tíbias de ratos, por meio da análise da densidade óptica digital. Vinte ratos da linhagem Wistar foram divididos em 2 grupos: um grupo controle (sem tratamento) e um grupo tratado com cetoprofeno. Os procedimentos experimentais consistiram de: anestesia, cirurgia, administração do cetoprofeno e exame radiográfico. As imagens radiográficas foram adquiridas empregando-se o sensor digital Visualix GX-S-HDI™ e um aparelho de raios X. As radiografias foram realizadas nos períodos baseline (inicial), 7, 14, 21 e 30 dias pós-operatório, sendo a densidade óptica (DO) avaliada por meio do sistema Vix winTM 1.4. Os valores médios da leitura da do obtidos foram analisados estatisticamente por meio de ANOVA e teste de Tukey com nível de significância de 5%. No grupo controle, houve diferença estatisticamente significante (p=0,001) entre o tempo e a DO, enquanto no grupo tratado com cetoprofeno a diferença não foi estatisticamente significante (p=0,100). O grupo controle apresentou as menores proporções de do (%) no 1º e 7º dias e as maiores proporções de do (%) no 14º, 21º e 30º dias, com diferença estatisticamente significante (p=0,001). Não houve diferença estatisticamente significante (p=0,100) entre as proporções médias de do (%) no grupo tratado, independentemente do período de avaliação. Os achados deste trabalho sugerem que houve influência do cetoprofeno sobre o processo de reparo ósseo, uma vez que na primeira semana o medicamento proporcionou aumento na densidade óptica e provocou atraso na neoformação óssea após o 21º dia.