986 resultados para dental implant-abutment design
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Nowadays, articaine hydrochloride (ATC) is a local anesthetic widely used in dental procedures, but its side effects include paresthesia and nerve injury. Alginate/chitosan nanoparticles (AG/CSnano) can be used as carrier for drugs, overcoming the problems. The aim of this work was to evaluate the factors (Calcium/alginate [Ca2+:AG] and Chitosan/alginate [CS:AG] mass ratios) influence on the average size, polydispersity index, zeta potential and encapsulation efficiency of ATC. AG/CSnano containing ATC were prepared by ionic pregelation method. A three-level factorial design was carried out and the factors varied were Ca2+/AG mass ratio and CS/AG mass ratio. There were obtained nanoparticles with size range of 340–550 nm and polydispersity index between 0.2 and 0.5, zeta potential range –19 and –22 mV and encapsulation efficiency of ATC in AG/Csnano between 22 and 45%. According to the results, the average size, polydispersity index and encapsulation efficiency were significantly affected to the variation of Ca2+/AG and CS/AG mass ratio, but the zeta potential didn't change significantly with factor variations. The factorial design showed it was possible to identify formulations that presented better results for the parameters measured. The factor chosen for the suitable formulations was the encapsulation efficiency. Through this parameter, one formulation was chosen with highest encapsulation efficiency of ATC and presented good colloidal stability parameters aiming future clinical applications.
Resumo:
By means of tensile strength, NiCr total crowns were removed from machine-made conical abutments composed by an Ti-6Al-4V alloy. In a total of 20 abutments, 10 were used with it surface presenting high smoothness and 10 abutments had its surfaces modifi ed by laser both cemented with zinc phosphate. The mechanical test was performed at a MTS 810 universal machine adjusted to a speed of 0.5 mm/m. The statistical analysis was done by Levene’s test, which showed homogeneity of variances among groups (F =2.21; p < 0.1). “Student t test” showed that signifi cant differences were found between groups. The modifi cation of the abutment surface through laser caused an increase in pull-out resistance of crowns cemented with zinc phosphate from 430.66 N to 1.514,87 N.
Resumo:
AIM: The aim of this study was to evaluate, through a systematic review of the literature, the effects of different implant surface modifications on osseointegration in diabetic subjects. METHODS: A search was performed of the PubMed database, using a combination of the following keywords: “Implant surface” OR “Dental implants” AND “Diabetes” OR “Hyperglycemia”. Papers published in English between January 1960 and November 2013 were selected. All experimental models were considered in this search, but case reports and in vitro studies were excluded from this review. RESULTS: The initial search identified 182 articles. After reading the titles and abstracts, 39 articles were selected for full reading. Finally, 4 papers were selected after evaluation of all the papers, and these papers are discussed in this review. Due to the methodological heterogeneity of the selected studies, it was not possible to perform a meta-analysis of the data. CONCLUSION: It can be concluded that although the benefits of surface modifications present in individuals with diabetes have biological plausibility, there is little evidence of the benefits of these modifications.
Resumo:
Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.
Resumo:
Introduction: In clinical situations where severe bone resorption has occurred following tooth loss, implant treatment options may comprise either a previous bone reconstruction or only the use of short implants. Objective: This non-systematic review summarizes and discusses some aspects of the use of short implants, such as: biomechanical aspects, success rate, longevity and surgical-prosthetic planning. Literature review: Current and relevant references were selected in order to compare short dental implants to conventional ones. Several studies have highlighted the great importance of wide-diameter implants. Dental short implants have shown high predictability and success rates when some biomechanical aspects are taken into consideration. Conclusion: Placement of short dental implants is a viable treatment method for patients with decreased bone height.
Resumo:
The purpose of this paper was to evaluate the influence of different implant designs on the micromovements of immediately placed implants. CT-based finite element models comprising an upper central incisor socket and four commercially available internal connection implant designs (SIN SW®, 3i Certain®, Nobel ReplaceTM, and RN synOcta® ITI Standard) of comparable diameter and length were constructed. 50, 100 and 200N magnitude loads were applied over the implant. ANOVA at 95% level of significance was used to evaluate bone to implant relative displacement (micromovements). The implant design (68,80%) greatly influences the micromovement of immediately placed implants. However, the loading magnitude (68,80%) is the most important factor regarding the implant stability in this protocol.
Resumo:
The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.
Resumo:
The aim of this paper is to present a complex rehabilitation, of fractured tooth, with implants in anterior region considering the orthodontics extrusion to clinical success. At 7 years old, the patient fractured the maxillary left central incisor and the dentist did a crown with the fragment. Twenty years later, the patient was referred to a dental clinic for orthodontic treatment, with the chief complaint related to an accentuated deep bite, and a professional started an orthodontic treatment. After sixteen months of orthodontic treatment, tooth 21 fractured. The treatment plan included an orthodontic extrusion of tooth 21 and implant placement. This case has been followed up and the clinical and radiographic examinations show excellence esthetic results and satisfaction of patient. The forced extrusion can be a viable treatment option in the management of crown root fracture of an anterior tooth to gain bone in a vertical direction. This case emphasizes that to achieve the esthetic result a multidisciplinary approach is necessary.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
A prospective clinical study of maxillary sinus lift procedures in the posterior region of the maxilla, using only blood clot as filling material, was conducted. Seventeen patients underwent a maxillary sinus lift procedure; 20 maxillary sinus regions were operated on and a total of 25 implants were placed. The sinus mucosa was lifted together with the anterior wall of the osteotomized maxilla and supported by the implants placed. Computed tomography (CT) scans were obtained immediately postoperative (T-initial) and at 3 (T-1) and 51(T-2) months postoperative for the measurement of linear bone height and bone density (by grey tones). Only one implant was lost in the first stage (96% success). After dental prosthesis placement and during up to 51 months of follow-up, no implant was lost (100% success, second stage). The difference in mean bone height between T-initial (5.94 mm) and T-1 (13.14 mm), and between T-initial and T-2 (11.57 mm), was statistically significant (both P < 0.001); comparison between T-1 and T-2 also presented a statistical difference (P < 0.001). Bone density had increased at the end of the period analyzed, but this was not statistically significant (P > 0.05). Thus, the maxillary sinus lift technique with immediate implant placement, filling with blood clot only, may be performed with a high success rate.
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: The aim of this systematic review was to compare straight-line and offset implant configurations for three-element implant-retained prostheses. Materials and Methods: Two independent reviewers conducted a review on PubMed/Medline, EMBASE, and Cochrane Library for studies published in English, from January 1, 1995 to January 17, 2014. A systematic review was conducted following the PRISMA statement. All relevant titles were selected according to inclusion/exclusion criteria. From this pool of titles, abstracts and full texts were reviewed. Results: A total of 6080 titles were identified with the initial search. Twenty-one were selected based on title and abstract. Of these, after discussion and complete reading, 12 studies were selected according to the inclusion and exclusion criteria, all of which were in vitro studies. Conclusions: A systematic review of the current literature showed only in vitro evidence that there is no consensus on the advantage of using an offset configuration implant compared to those in straight-line configuration, even though some studies present a slight improvement of bone stress distribution when an offset implant is under oblique loading (PICO).