889 resultados para computer vision, facial expression recognition, swig, red5, actionscript, ruby on rails, html5


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objectives - Postoperative pain is one of the major discomforts but often under treated, especially in the pediatric patient. The aim of this study was to evaluate nasal morphine postoperative analgesia as an alternative drug administration route and show its applicability, effectiveness, tolerability and side effects. Methods - Participated in this study 20 patients aged 3 to 13 years, physical status ASA I and II sequentially submitted the different small and medium-size surgeries. Analgesia was obtained with nasal morphine hydrochloride in aqueous solution in variable concentrations of 2%, 1%, 0.5%, 0.25% and 0.125%. The dose for each instillation has been 0.1 mg.kg -1 at three-hour intervals for 36 postoperative hours. Quality of analgesia in pre-verbal age patients was evaluated by a pain intensity scale based on facial expression and crying, sleep, motor activity, sociability and food ingestion was used. Standardized evaluations were performed at 3-hour intervals. A four-grade scale was used to evaluate tolerability, where: 1) Good; 2) Regular; 3) Bad; 4) Very bad. Result - Postoperative analgesia results have proven to be good and safe, especially from the third evaluation on (6 hours). Drug tolerability has been good, although side effects were observed, especially nausea and vomiting. Conclusions - Patients and relatives accepted the method very well. The nasal route was considered an adequate way for opioid administration although more studies are needed to accept it as a routine for postoperative morphine analgesia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the main problems in Computer Vision and Close Range Digital Photogrammetry is 3D reconstruction. 3D reconstruction with structured light is one of the existing techniques and which still has several problems, one of them the identification or classification of the projected targets. Approaching this problem is the goal of this paper. An area based method called template matching was used for target classification. This method performs detection of area similarity by correlation, which measures the similarity between the reference and search windows, using a suitable correlation function. In this paper the modified cross covariance function was used, which presented the best results. A strategy was developed for adaptative resampling of the patterns, which solved the problem of deformation of the targets due to object surface inclination. Experiments with simulated and real data were performed in order to assess the efficiency of the proposed methodology for target detection. The results showed that the proposed classification strategy works properly, identifying 98% of targets in plane surfaces and 93% in oblique surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several kinds of research in road extraction have been carried out in the last 6 years by the Photogrammetry and Computer Vision Research Group (GPF&VC - Grupo de Pesquisa em Fotogrametria e Visão Computacional). Several semi-automatic road extraction methodologies have been developed, including sequential and optimizatin techniques. The GP-F&VC has also been developing fully automatic methodologies for road extraction. This paper presents an overview of the GP-F&VC research in road extraction from digital images, along with examples of results obtained by the developed methodologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to measure and verify the esthetic influence of the bilateral spaces between maxillary teeth and lip corners, called negative space (NS), during smile. The sample was comprised of 60 smile photographs obtained from 60 individuals (30 men and 30 women) aged 18 to 25 years old. Two orthodontists and two lay people evaluated these pictures regarding esthetics by a visual analogue scale. In each picture, the right and left NS were measured in millimeters and in proportion to the smile width (SW). Data were analyzed for statistical significance (P = .05). The mean NS of the sample was 6.68 ± 1.99 mm, and the NS proportion in relation to the SW was 9.6 ± 2.56%, for both sides of the arch. No significant asymmetries were observed between the right and left sides. The NS was significantly larger in men than in women when measured in millimeters (P = .028) (7.08 ± 2.24 mm in men vs 6.28 ± 1.62 mm in women), but the NS proportion to the SW was similar (9.94 ± 2.24% in men vs 9.26 ± 1.61% in women). When the 12 individuals with the smallest NS in proportion to SW were compared with the 12 individuals with the largest NS in proportion to SW, there was no statistical difference regarding the esthetic evaluation (P = .11). It was concluded that the NS did not influence the esthetic evaluation of smile photographs in the sample in this study, for both orthodontists and lay people. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optimal facial esthetics is one of the objectives in orthodontic treatment and an important issue in modern society. In this context, orthodontic treatment permits individuals with dental malpositions to achieve improved dentofacial esthetics. To reach this result, the orthodontist needs to recognize the characteristics considered normal and pleasant in dental arches and smiles. The objective of this article is to review and discuss criterion adopted by dental literature to technically analyze the smile, such as dental midline, smile line, dental exposure, negative space, dental proportion, and symmetry. This article proposes a way to visualize an ideal smile for each patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methods based on visual estimation still is the most widely used analysis of the distances that is covered by soccer players during matches, and most description available in the literature were obtained using such an approach. Recently, systems based on computer vision techniques have appeared and the very first results are available for comparisons. The aim of the present study was to analyse the distances covered by Brazilian soccer players and compare the results to the European players', both data measured by automatic tracking system. Four regular Brazilian First Division Championship matches between different teams were filmed. Applying a previously developed automatic tracking system (DVideo, Campinas, Brazil), the results of 55 outline players participated in the whole game (n = 55) are presented. The results of mean distances covered, standard deviations (s) and coefficient of variation (cv) after 90 minutes were 10,012 m, s = 1,024 m and cv = 10.2%, respectively. The results of three-way ANOVA according to playing positions, showed that the distances covered by external defender (10642 ± 663 m), central midfielders (10476 ± 702 m) and external midfielders (10598 ± 890 m) were greater than forwards (9612 ± 772 m) and forwards covered greater distances than central defenders (9029 ± 860 m). The greater distances were covered in standing, walking, or jogging, 5537 ± 263 m, followed by moderate-speed running, 1731 ± 399 m; low speed running, 1615 ± 351 m; high-speed running, 691 ± 190 m and sprinting, 437 ± 171 m. Mean distance covered in the first half was 5,173 m (s = 394 m, cv = 7.6%) highly significant greater (p < 0.001) than the mean value 4,808 m (s = 375 m, cv = 7.8%) in the second half. A minute-by-minute analysis revealed that after eight minutes of the second half, player performance has already decreased and this reduction is maintained throughout the second half. ©Journal of Sports Science and Medicine (2007).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To present a technique for filling facial folds by using autologous orbicularis oculi muscle, based on an experimental model. Methods: two studies are presented: (1) an experimental study using 15 albino guinea-pigs from which a strip of the sural triceps muscle was removed and implanted in the subcutaneous tissue of the dorsal area. The animals were sacrificed 7, 30 and 60 days after the implantation, and the material was histologically evaluated. And (2%) an interventional prospective clinical trial carried out on 20 patients referred to blepharoplasty surgery. They received autologous preseptal orbicularis muscle for filling facial folds. The results where evaluated by patients satisfaction and clinical exam. Results: the sural tricep muscle, when implanted in the subcutaneous tissue, resulted in fibrosis. The patients whom received autologous orbicularis muscle implanted for filling facial folds showed that the procedure can be successfully carried out. Conclusions: autologous preseptal orbicularis muscle is a good material for filling facial folds. Cicatricial tissue will be formed on its implantation site, filling the tissue gap that forms the folds on the skin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Automatic inspection of petroleum well drilling has became paramount in the last years, mainly because of the crucial importance of saving time and operations during the drilling process in order to avoid some problems, such as the collapse of the well borehole walls. In this paper, we extended another work by proposing a fast petroleum well drilling monitoring through a modified version of the Optimum-Path Forest classifier. Given that the cutting's volume at the vibrating shale shaker can provide several information about drilling, we used computer vision techniques to extract texture informations from cutting images acquired by a digital camera. A collection of supervised classifiers were applied in order to allow comparisons about their accuracy and effciency. We used the Optimum-Path Forest (OPF), EOPF (Efficient OPF), Artificial Neural Network using Multilayer Perceptrons (ANN-MLP) Support Vector Machines (SVM), and a Bayesian Classifier (BC) to assess the robustness of our proposed schema for petroleum well drilling monitoring through cutting image analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents three methods for automatic detection of dust devils tracks in images of Mars. The methods are mainly based on Mathematical Morphology and results of their performance are analyzed and compared. A dataset of 21 images from the surface of Mars representative of the diversity of those track features were considered for developing, testing and evaluating our methods, confronting their outputs with ground truth images made manually. Methods 1 and 3, based on closing top-hat and path closing top-hat, respectively, showed similar mean accuracies around 90% but the time of processing was much greater for method 1 than for method 3. Method 2, based on radial closing, was the fastest but showed worse mean accuracy. Thus, this was the tiebreak factor. © 2011 Springer-Verlag.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hyoid bone contributes to the maintenance of the airway, chewing and swallowing, given to its anatomical and functional relations to the craniocervical complex. Cephalometric analysis has great importance for orthopedics, orthodontics and oral maxillary surgery. For the treatment of patients with special care needs, the cephalometric evaluation of the position of the hyoid bone should also contribute as a complementary element for dental diagnosis and the selection of the adequate treatment. The aim of this paper is to demonstrate the alteration of the hyoid position after carrying out the functional orthopedic maxillary treatment in a 9 year-old patient with Down Syndrome. Initial cephalometric analysis revealed inadequate position of hyoid bone. The association of speech therapy to dynamic functional rehabilitation of jaws showed a positive effect in occlusal relation and facial expression. After treatment, all dimensions obtained from the hyoid triangle were higher than initial ones, except the anterior-posterior value of C3-H, which suggested function improvement of stomatognathic system. Once considered its anatomical and physiological relationship with the others structures of the stomatognathic system, cephalometric analysis of hyoid bone position was helpful to the comprehension of the craniofacial abnormalities related to chromosomal anomaly, and thus is essential to the interdisciplinary dialogue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Augmented Reality (AR) systems which use optical tracking with fiducial marker for registration have had an important role in popularizing this technology, since only a personal computer with a conventional webcam is required. However, in most these applications, the virtual elements are shown only in the foreground a real element does not occlude a virtual one. The method presented enables AR environments based on fiducial markers to support mutual occlusion between a real element and many virtual ones, according to the elements position (depth) in the environment. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dengue virus is a mosquito-borne flavivirus that has a large impact in global health. It is considered as one of the medically important arboviruses, and developing a preventive or therapeutic solution remains a top priority in the medical and scientific community. Drug discovery programs for potential dengue antivirals have increased dramatically over the last decade, largely in part to the introduction of high-throughput assays. In this study, we have developed an image-based dengue high-throughput/high-content assay (HT/HCA) using an innovative computer vision approach to screen a kinase-focused library for anti-dengue compounds. Using this dengue HT/HCA, we identified a group of compounds with a 4-(1-aminoethyl)-N-methylthiazol-2-amine as a common core structure that inhibits dengue viral infection in a human liver-derived cell line (Huh-7.5 cells). Compounds CND1201, CND1203 and CND1243 exhibited strong antiviral activities against all four dengue serotypes. Plaque reduction and time-of-addition assays suggests that these compounds interfere with the late stage of viral infection cycle. These findings demonstrate that our image-based dengue HT/HCA is a reliable tool that can be used to screen various chemical libraries for potential dengue antiviral candidates. © 2013 Cruz et al.