832 resultados para accelerometer accuracy
Resumo:
Hitting a moving target demands that movement is both spatially and temporally accurate. Recent experiments have begun to reveal how performance of such actions depends on the spatial and temporal accuracy requirements of the task. The results suggest a simple strategy for achieving spatiotemporal accuracy using brief, high-speed movements.
Resumo:
Purpose: Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. Methods: First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21degreesC) and time (1 h at similar to300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. Results: The mean error scores for SRM and PT factory calibration over a range of 50-1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however. power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. Conclusions: When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.
Resumo:
OBJECTIVES We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). BACKGROUND Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. METHODS Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. RESULTS The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. CONCLUSIONS Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice. (C) 2004 by the American College of Cardiology Foundation.
Resumo:
Achievement of steady state during indirect calorimetry measurements of resting energy expenditure (REE) is necessary to reduce error and ensure accuracy in the measurement. Steady state is often defined as 5 consecutive min (5-min SS) during which oxygen consumption and carbon dioxide production vary by +/-10%. These criteria, however, are stringent and often difficult to satisfy. This study aimed to assess whether reducing the time period for steady state (4-min SS or 3-min SS) produced measurements of REE that were significantly different from 5-min SS. REE was measured with the use of open-circuit indirect calorimetry in 39 subjects, of whom only 21 (54%) met the 5-min SS criteria. In these 21 subjects, median biases in REE between 5-min SS and 4-min SS and between 5-min SS and 3-min SS were 0.1 and 0.01%, respectively. For individuals, 4-min SS measured REE within a clinically acceptable range of +/-2% of 5-min SS, whereas 3-min SS measured REE within a range of -2-3% of 5-min SS. Harris-Benedict prediction equations estimated REE for individuals within +/-20-30% of 5-min SS. Reducing the time period of steady state to 4 min produced measurements of REE for individuals that were within clinically acceptable, predetermined limits. The limits of agreement for 3-min SS fell outside the predefined limits of +/-2%; however, both 4-min SS and 3-min SS criteria greatly increased the proportion of subjects who satisfied steady state within smaller limits than would be achieved if relying on prediction equations.
Resumo:
Videoconferencing has become a routine technique for the post-acute burns care of children in Queensland. We compared the agreement between clinical assessments conducted via videoconference and assessments conducted in the conventional, face-to-face manner (FTF). A total of 35 children with a previous burn injury were studied. Twenty-five children received three consecutive assessments: first FTF by a consultant in the outpatient department, then by a second consultant who reviewed the patient via videoconference, and then by the second consultant in person. The second consultant also reviewed another 10 children twice. At each review, the following variables were measured: scar colour, scar thickening, contractures, range of motion, the patient's level of general activity, any breakdown of the graft site, and adequacy of the consultation. Agreement between the two consultants when seeing patients FTF was moderately high, with an overall concordance of 85%. When videoconferencing was used, the level of agreement was almost the same, at 84%. If one consultant reviewed patients FTF first and then via videoconference, the overall concordance was 98%; if the process was reversed, the overall concordance was 97%. This study confirms that the quality of information collected during a videoconference appointment is comparable to that collected during a traditional, FTF appointment for a follow-up burns consultation.
Resumo:
The H I Parkes All Sky Survey (HIPASS) is a blind extragalactic H I 21-cm emission-line survey covering the whole southern sky from declination -90degrees to +25degrees. The HIPASS catalogue (HICAT), containing 4315 H I-selected galaxies from the region south of declination +2degrees, is presented in Meyer et al. (Paper I). This paper describes in detail the completeness and reliability of HICAT, which are calculated from the recovery rate of synthetic sources and follow-up observations, respectively. HICAT is found to be 99 per cent complete at a peak flux of 84 mJy and an integrated flux of 9.4 Jy km. s(-1). The overall reliability is 95 per cent, but rises to 99 per cent for sources with peak fluxes >58 mJy or integrated flux >8.2 Jy km s(-1). Expressions are derived for the uncertainties on the most important HICAT parameters: peak flux, integrated flux, velocity width and recessional velocity. The errors on HICAT parameters are dominated by the noise in the HIPASS data, rather than by the parametrization procedure.
Resumo:
In this paper, we assess the relative performance of the direct valuation method and industry multiplier models using 41 435 firm-quarter Value Line observations over an 11 year (1990–2000) period. Results from both pricingerror and return-prediction analyses indicate that direct valuation yields lower percentage pricing errors and greater return prediction ability than the forward price to aggregated forecasted earnings multiplier model. However, a simple hybrid combination of these two methods leads to more accurate intrinsic value estimates, compared to either method used in isolation. It would appear that fundamental analysis could benefit from using one approach as a check on the other.
Resumo:
This study was designed to assess the effect of sequence mismatches between primers and their targets on viral quantitative PCR. Numerous primers were constructed incorporating various mismatches with a target sequence on the BKV T antigen gene. When using these primers in standard Taqman two-step cycling conditions, as few as two mismatches in a single primer increased cycle threshold values and significantly influenced the calculation of viral load. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
A meta-analysis of rapid (
Resumo:
In the past, the accuracy of facial approximations has been assessed by resemblance ratings (i.e., the comparison of a facial approximation directly to a target individual) and recognition tests (e.g., the comparison of a facial approximation to a photo array of faces including foils and a target individual). Recently, several research studies have indicated that recognition tests hold major strengths in contrast to resemblance ratings. However, resemblance ratings remain popularly employed and/or are given weighting when judging facial approximations, thus indicating that no consensus has been reached. This study aims to further investigate the matter by comparing the results of resemblance ratings and recognition tests for two facial approximations which clearly differed in their morphological appearance. One facial approximation was constructed by an experienced practitioner privy to the appearance of the target individual (practitioner had direct access to an antemortem frontal photograph during face construction), while the other facial approximation was constructed by a novice under blind conditions. Both facial approximations, whilst clearly morphologically different, were given similar resemblance scores even though recognition test results produced vastly different results. One facial approximation was correctly recognized almost without exception while the other was not correctly recognized above chance rates. These results suggest that resemblance ratings are insensitive measures of the accuracy of facial approximations and lend further weight to the use of recognition tests in facial approximation assessment. (c) 2006 Elsevier Ireland Ltd. All rights reserved.