993 resultados para Visual impaired


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A patent foramen ovale (PFO), present in ∼40% of the general population, is a potential source of right-to-left shunt that can impair pulmonary gas exchange efficiency [i.e., increase the alveolar-to-arterial Po2 difference (A-aDO2)]. Prior studies investigating human acclimatization to high-altitude with A-aDO2 as a key parameter have not investigated differences between subjects with (PFO+) or without a PFO (PFO-). We hypothesized that in PFO+ subjects A-aDO2 would not improve (i.e., decrease) after acclimatization to high altitude compared with PFO- subjects. Twenty-one (11 PFO+) healthy sea-level residents were studied at rest and during cycle ergometer exercise at the highest iso-workload achieved at sea level (SL), after acute transport to 5,260 m (ALT1), and again at 5,260 m after 16 days of high-altitude acclimatization (ALT16). In contrast to PFO- subjects, PFO+ subjects had 1) no improvement in A-aDO2 at rest and during exercise at ALT16 compared with ALT1, 2) no significant increase in resting alveolar ventilation, or alveolar Po2, at ALT16 compared with ALT1, and consequently had 3) an increased arterial Pco2 and decreased arterial Po2 and arterial O2 saturation at rest at ALT16. Furthermore, PFO+ subjects had an increased incidence of acute mountain sickness (AMS) at ALT1 concomitant with significantly lower peripheral O2 saturation (SpO2). These data suggest that PFO+ subjects have increased susceptibility to AMS when not taking prophylactic treatments, that right-to-left shunt through a PFO impairs pulmonary gas exchange efficiency even after acclimatization to high altitude, and that PFO+ subjects have blunted ventilatory acclimatization after 16 days at altitude compared with PFO- subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nicotine consumption is higher for people within the schizophrenia spectrum compared to controls. This observation supports the self-medication hypothesis, that nicotine relieves symptoms in, for example, schizophrenia patients. We tested whether performance in an endophenotype of schizophrenia (visual backward masking, VBM) is modulated by nicotine consumption in i) smoking and non-smoking schizophrenia patients, their first-degree relatives, and age-matched controls, ii) non-smoking and smoking university students, and iii) non-smoking, early and late onset nicotine smokers. Overall, our results confirmed that VBM deficits are an endophenotype of schizophrenia, i.e., deficits were highest in patients, followed by their relatives, students scoring high in Cognitive Disorganisation, and controls. Moreover, we found i) beneficial effects of chronic nicotine consumption on VBM performance, in particular with increasing age, and ii) little impact of clinical status. alone or in interactionwith nicotine consumption on VBMperformance. Given the younger age of undergraduate students (up to 30 years) versus controls and patients (up to 66 years),we propose that age-dependent VBMdeficits emergewhen schizotypy effects are targeted in populations of a larger age range, but that nicotine consumption might counteract these deficits (supporting the self-medication hypothesis).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the functional outcome of eyes with neovascular AMD (nAMD) and subretinal fluid (SRF) refractory to treatment with ranibizumab. METHODS: Retrospective chart review of consecutive treatment-refractory SRF in nAMD despite monthly ranibizumab injections during 12 months or more. Data were evaluated for baseline characteristics, location of the refractory SRF, mean visual acuity (VA) change, number of injections, and timepoint of first complete disappearance of SRF. RESULTS: Forty-five eyes in 44 patients (mean age of 76 years) were included. The mean follow-up was 32.4 months (range 12-73 months). The mean number of injections was 11.6 in the first year and 27.5 over follow-up. The refractory SRF was located subfoveally in 66.7 %. In 12 eyes (26.7 %), complete absorption of SRF was found after a mean of 22.6 months (range, 13-41 months). Mean VA increased by 10.4, 8.2, and 8.6 letters by month 12, 24, and 36, respectively. CONCLUSIONS: Neovascular AMD with SRF refractory to monthly retreatment with ranibizumab may still allow good and maintained visual improvement, even if the fluid is located subfoveally. SRF may progressively absorb under continuous monthly treatment. The necessity to treat refractory SRF with monthly injections could be questioned and would need future investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Best corrected visual acuity (BCVA) of 0.8 or above in AMD patients can sometimes correspond to poor macular function inducing a serious visual handicap. Microperimetry can be used to objectivize this difference. PATIENTS AND METHODS: A retrospective study was undertaken on 233 files of AMD patients of whom 82 had had a microperimetry. BCVA was compared with microperimetry performance. All examinations were performed in an identical setting by the same team of 3 persons. RESULTS: Among the 82 patients included, 32 (39.0%) had a BCVA equal to or above 0.8 even though their microperimetry performance was lower than 200/560 db. 10 of them (12.2% of total) had an even poorer microperimetry below 120/560 db indicating poor macular function. CONCLUSIONS: More than a third of the AMD patients had a bad or very bad microperimetry performance in parallel with a good visual acuity. Microperimetry is a valuable tool to assess and follow real macular function in AMD patients when visual acuity alone can be misleading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Huolimatta korkeasta automaatioasteesta sorvausteollisuudessa, muutama keskeinen ongelma estää sorvauksen täydellisen automatisoinnin. Yksi näistä ongelmista on työkalun kuluminen. Tämä työ keskittyy toteuttamaan automaattisen järjestelmän kulumisen, erityisesti viistekulumisen, mittaukseen konenäön avulla. Kulumisen mittausjärjestelmä poistaa manuaalisen mittauksen tarpeen ja minimoi ajan, joka käytetään työkalun kulumisen mittaukseen. Mittauksen lisäksi tutkitaan kulumisen mallinnusta sekä ennustamista. Automaattinen mittausjärjestelmä sijoitettiin sorvin sisälle ja järjestelmä integroitiin onnistuneesti ulkopuolisten järjestelmien kanssa. Tehdyt kokeet osoittivat, että mittausjärjestelmä kykenee mittaamaan työkalun kulumisen järjestelmän oikeassa ympäristössä. Mittausjärjestelmä pystyy myös kestämään häiriöitä, jotka ovat konenäköjärjestelmille yleisiä. Työkalun kulumista mallinnusta tutkittiin useilla eri menetelmillä. Näihin kuuluivat muiden muassa neuroverkot ja tukivektoriregressio. Kokeet osoittivat, että tutkitut mallit pystyivät ennustamaan työkalun kulumisasteen käytetyn ajan perusteella. Parhaan tuloksen antoivat neuroverkot Bayesiläisellä regularisoinnilla.