884 resultados para Validation of analytical methodology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Despite the focus on facial photoaging ratings, there are few classifications developed for forearm skin aging assessment.Objective: To develop and validate a clinical scale for the evaluation of forearm skin aging.Methods: Three clinical dermatology faculty members selected, discussed, and appraised the main signs of forearm photoaging. The validation of the resulting scale was performed by 5 assessors who were previously trained to classify 102 photographs of forearms with different degrees of aging. Retests were performed in 15 days.Results: There was significant correlation between the selected variables and the subjective global aging scale. The developed scale showed high internal consistency (Cronbach's alpha = 0.87) and high correlation with the global photoaging scale (rho = 0.92). Inter- and intraobserver final scores showed high agreement.Conclusion: A validated clinical photoaging scale for forearms with internal consistency, reliability, and validity was developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was studied the trapezius muscle and serratus anterior muscle in 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes, during the execution of four different modalities of military press exercises with open grip. The results showed that TS acted significantly in the modalities standing and sitting press behind neck, while SI acted in all the modalities, i.e., standing and sitting press behind neck and forward, justifying their inclusion as basic exercises for physical conditioning programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To validate a model for investigating the effects of analgesic drugs on mechanical, thermal and electrical stimulation testing. To investigate repeatability, sensitivity and specificity of nociceptive tests. Randomised experiment with 2 observers in 2 phases. Mechanical (M), thermal (TL) and electrical (E) stimuli were applied to the dorsal metacarpus (M-left and TL-right) and coronary band of the left thoracic limb (E) and a thoracic thermal stimulus (TT) was applied caudal to the withers in 8 horses (405 ± 43 kg). Stimuli intensities were increased until a clear avoidance response was detected without exceeding 20 N (M), 60°C (TL and TT) and 15 V (E). For each set of tests, 3 real stimuli and one sham stimulus were applied (32 per animal) using a blinded, randomised, crossover design repeated after 6 months. A distribution frequency and, for each stimulus, Chi-square and McNemar tests compared both the proportion of positive responses detected by 2 observers and the 2 study phases. The κ coefficients estimated interobserver agreement in determining endpoints. Sensitivity (384 tests) and specificity (128 tests) were evaluated for each nociceptive stimulus to assess the evaluators' accuracy in detecting real and sham stimuli. Nociceptive thresholds were 3.1 ± 2 N (M), 8.1 ± 3.8 V (E), 51.4 ± 5.5°C (TL) and 55.2 ± 5.3°C (TT). The level of agreement after all tests, M, E, TL and TT, was 90, 100, 84, 98 and 75%, respectively. Sensitivity was 89, 100, 89, 98 and 70% and specificity 92, 97, 88, 91 and 94%, respectively. The high interobserver agreement, sensitivity and specificity suggest that M, E and TL tests are valid for pain studies in horses and are suitable tools for investigating antinociceptive effects of analgesics in horses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An accurate, sensitive, precise and rapid reversed-phase high-performance liquid chromatographic method was successfully developed and validated for the determination of caffeic acid (CA) in emulsions. The best separation was achieved on a 250 × 4.6 mm, 5.0 µm particle size RP18 XDB Waters column using ethanol and purified water (40:60 v/v) adjusted to pH 2.5 with acetic acid as the mobile phase at a flow rate of 0.7 mL/min. Ultraviolet detection was performed at 325 nm at ambient column temperature (25°C). The method was linear over the concentration range of 10-60 µg/mL (r(2) = 0.9999) with limits of detection and quantification of 1.44 and 4.38 µg/mL, respectively. CA was subjected to oxidation, acid, base and neutral degradation, as well as photolysis and heat as stress conditions. There were no interfering peaks at or near the retention time of CA. The method was applied to the determination of CA in standard and pharmaceutical products with excellent recoveries. The method is applicable in the quality control of CA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A GC method to determine caprolactam in water, 15 ethanol, and olive oil food simulants was developed and validated. Linear ranges varied from 0.96 to 642.82 g/mL for water, 0.64 to 800.32 g/mL for 15 ethanol, and 1.06 to 1062.34 g/g for olive oil, with correlation coefficients higher than 0.999. Method precision studies showed RSD values lower than 5.45, while method accuracy studies showed recovery from 72 to 111 for all simulants. The effect of gamma irradiation on caprolactam migration from multilayer polyamide 6 (PA-6) films intended for cheese into water, 15 ethanol, olive oil, and 3 acetic acid simulants was also studied. For migration assay, non-irradiated and irradiated (12 kGy) films were placed in contact with the simulant and exposed at 40C for 10 days. The validated method was used to quantify caprolactam migration from multilayer PA-6 films into the simulants, which ranged from 1.03 to 7.59 mg/kg for non-irradiated films, and from 4.82 to 11.32 mg/kg for irradiated films. Irradiation caused almost no changes in caprolactam levels, with the exception of olive oil, which showed an increase in the caprolactam level. All multilayer PA-6 films were in accordance with the requirements of the legislation for caprolactam migration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study is to develop and validate a dissolution test for fluconazole, an antifungal used for the treatment of superficial, cutaneous, and cutaneomucous infections caused by Candida species, in capsules dosage form. Techniques by HPLC and UV first derivative spectrophotometry (UV-FDS) were selected for quantitative evaluation. In the development of release profile, several conditions were evaluated. Dissolution test parameters were considered appropriate when a most discriminative release profile for fluconazole capsules was yielded. Dissolution test conditions for fluconazole capsules were 900 mL of HCl 0.1 M, 37 ± 0.5 °C using baskets with 50 rpm for 30 min of test. The developed HPLC and UV-FDS methods for the antifungal evaluation were selective and met requirements for an appropriate and validated method, according to ICH and USP requirements. Both methods can be useful in the registration process of new drugs or their renewal. For routine analysis application cost, simplicity, equipment, solvents, speed, and application to large or small workloads should be observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Darunavir (DRV) is a protease inhibitor used in the treatment of HIV infection, which constitutes a keystone in the therapy of patients infected with this virus. There is no monograph described in official compendia. The literature provides few methods of analysis for the determination of DRV in pharmaceuticals which include TLC, IR, UPLC, HPLC, HPLC-MS, HPLC-MS/MS, but there are no reports of the use of capillary electrophoresis (CE) for the determination of this drug. Thus, this research proposed the development and validation of a CE method for the determination of DRV in tablets. The method was completely validated according to the International Conference on Harmonization guidelines, showing linearity, selectivity, precision, accuracy and robustness. The migration was achieved in less than 1 minute using fused-silica uncoated capillary with an id of 50 μm and total length of 21 cm and voltage of +20 kV. The sample injection was performed in the hydrodynamic mode. The method was linear over the concentration range of 50-200 μg mL-1 with correlation coefficient 0.9998 and limits of detection and quantification of 7.29 and 22.09 μg mL-1, respectively. The drug was subjected to acid, base, oxidation and photolysis degradation. Degradation products were found interfering with the assay of DRV, therefore the method can be regarded as stability indicating. The validated method is useful and appropriate for the routine quality control of DRV in tablets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antimicrobials have unquestionable importance in the control of many diseases; however the constant concern with evolution of resistant microorganisms is increasing. The ertapenem sodium is a β-lactam antibiotic of the carbapenem class, which it has a broader activity spectrum than most other β-lactam antimicrobials, and is more resistant to the enzyme β-lactamase, which is the main mechanism of resistance of many bacteria. The progress of microbial resistance to existing antibiotics is alarming. Thus we need to preserve antimicrobials that still have activity against these pathogens. In this context, the quality control has a key role to ensure the correct dosage, by contributing preventively to minimize the development of resistant microorganisms. Study of the physicochemical characteristics of the drug and the quantification of the content of active substance are of fundamental importance for the pharmaceutical industry to ensure the quality of the product sold. This work presents a literature survey of existing methods for ertapenem sodium quantification which was performed. Ertapenem sodium can be analyzed by many types of assays; however the HPLC is the most used method. This review will examine the published analytical methods reported for determination of ertapenem sodium, in biological fluids and formulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)