872 resultados para VALVE-REPLACEMENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Total knee replacement is the gold standard treatment for patients suffering from advanced symptomatic knee osteoarthritis. The main goals of knee prosthetics are pain reduction and restoration of knee motion. The new prostheses on the market such as the bi-cruciate stabilized Journey knee implant, promise a reconstruction of total physiological function of the knee with physiological range of motion and therefore high patient satisfaction. Purpose: The aim of this study was to analyze the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS) outcome after total knee replacement with new physiological bi-cruciate stabilized Journey knee prosthesis. Study Design: Prospective, consecutive case-series. Patients: Ninety nine patients, who received bi-cruciate stabilized Journey total knee prosthesis between January 1st 2006 and May 31st 2012, were included in the study. A single surgeon operated all patients. There were 61.1% females and the overall average age was 68 years (range 41-83 years). Left knee was replaced in 55.6%. Methods: The patients filled in KOO’s questionnaire pre- and 1 year postoperative. Range of motion (ROM) was studied preoperatively and at 1-year follow-ups. The pre- and postoperative KOOS subscores and ROM were compared using the Wilcoxon signed rank test. Results: There are significant improvements of all KOOS subscores. Ninety percent of patients have reached the minimum clinically relevant 10 points in symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sport and recreation, and 90% in knee related quality of life. Postoperative, the average passive ROM was 131° (range 110-145°) and the average active ROM 122° (range 105-135°). The highest correlation coefficients ROM and the KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore. Conclusions: Bi-cruciate stabilized knee prosthetic offers a solid outcome 1 year postoperative based on the results measured with the KOOS evaluation questionnaire. The Patients showed a generalized improvement in all domains measured in the KOOS of minimally 35, and up to over 52 points, what can be described as statistically significant. Patients described the level of functionality close to double compared to the preoperative status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM The aim of this study was to evaluate whether coronary artery disease (CAD) severity exerts a gradient of risk in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS A total of 445 patients with severe AS undergoing TAVI were included into a prospective registry between 2007 and 2012. The preoperative SYNTAX score (SS) was determined from baseline coronary angiograms. In case of revascularization prior to TAVI, residual SS (rSS) was also determined. Clinical outcomes were compared between patients without CAD (n = 158), patients with low SS (0-22, n = 207), and patients with high SS (SS >22, n = 80). The pre-specified primary endpoint was the composite of cardiovascular death, stroke, or myocardial infarction (MI). At 1 year, CAD severity was associated with higher rates of the primary endpoint (no CAD: 12.5%, low SS: 16.1%, high SS: 29.6%; P = 0.016). This was driven by differences in cardiovascular mortality (no CAD: 8.6%, low SS: 13.6%, high SS: 20.4%; P = 0.029), whereas the risk of stroke (no CAD: 5.1%, low SS: 3.3%, high SS: 6.7%; P = 0.79) and MI (no CAD: 1.5%, low SS: 1.1%, high SS: 4.0%; P = 0.54) was similar across the three groups. Patients with high SS received less complete revascularization as indicated by a higher rSS (21.2 ± 12.0 vs. 4.0 ± 4.4, P < 0.001) compared with patients with low SS. High rSS tertile (>14) was associated with higher rates of the primary endpoint at 1 year (no CAD: 12.5%, low rSS: 16.5%, high rSS: 26.3%, P = 0.043). CONCLUSIONS Severity of CAD appears to be associated with impaired clinical outcomes at 1 year after TAVI. Patients with SS >22 receive less complete revascularization and have a higher risk of cardiovascular death, stroke, or MI than patients without CAD or low SS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. Methods and results: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm2) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). Conclusions: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renal replacement therapy by hemodialysis requires a permanent vascular access. Implantable ports offer a potential alternative to standard vascular access strategies although their development is limited both in number and extent. We explored the fluid dynamics within two new percutaneous bone-anchored dialysis port prototypes, both by in vitro experiments and computer simulation. The new port is to be fixed to bone and allows the connection of a dialysis machine to a central venous catheter via a built-in valve. We found that the pressure drop induced by the two ports was between 20 and 50 mmHg at 500 ml/min, which is comparable with commercial catheter connectors (15–80 mmHg). We observed the formation of vortices in both geometries, and a shear rate in the physiological range (<10,000s-1), which is lower than maximal shear rates reported in commercial catheters (up to 13,000s-1). A difference in surface shear rate of 15% between the two ports was obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyse the results after elective open total aortic arch replacement. METHODS We analysed 39 patients (median age 63 years, median logistic EuroSCORE 18.4) who underwent elective open total arch replacement between 2005 and 2012. RESULTS In-hospital mortality was 5.1% (n = 2) and perioperative neurological injury was 12.8% (n = 5). The indication for surgery was degenerative aneurysmal disease in 59% (n = 23) and late aneurysmal formation following previous surgery of type A aortic dissection in 35.9% (n = 14); 5.1% (n = 2) were due to anastomotical aneurysms after prior ascending repair. Fifty-nine percent (n = 23) of the patients had already undergone previous proximal thoracic aortic surgery. In 30.8% (n = 12) of them, a conventional elephant trunk was added to total arch replacement, in 28.2% (n = 11), root replacement was additionally performed. Median hypothermic circulatory arrest time was 42 min (21-54 min). Selective antegrade cerebral perfusion was used in 95% (n = 37) of patients. Median follow-up was 11 months [interquartile range (IQR) 1-20 months]. There was no late death and no need for reoperation during this period. CONCLUSIONS Open total aortic arch replacement shows very satisfying results. The number of patients undergoing total arch replacement as a redo procedure and as a part of a complex multisegmental aortic pathology is high. Future strategies will have to emphasize neurological protection in extensive simultaneous replacement of the aortic arch and adjacent segments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glycogen storage disease type II is a rare multi-systemic disorder characterised by an intracellular accumulation of glycogen due a mutation in the acid alpha glucosidase (GAA) gene. The level of residual enzyme activity, the genotype and other yet unknown factors account for the broad variation of the clinical phenotype. The classical infantile form is characterised by severe muscle hypotonia and cardiomyopathy leading to early death. The late-onset form presents as a limb girdle myopathy with or without pulmonary dysfunction. Enzyme replacement therapy (ERT) with recombinant human GAA (rhGAA) in infants is life saving. In contrast, therapeutic efficacy of rhGAA in the late-onset form is modest. High expenses of rhGAA, on-going infusions and poor pharmacokinetic efficacy raised a discussion of the cost effectiveness of ERT in late-onset Pompe disease in Switzerland. This discussion was triggered by a Swiss federal court ruling which confirmed the reluctance of a health care insurer not to reimburse treatment costs in a 67-year-old female suffering from Pompe disease. As a consequence of this judgement ERT was stopped by all insurance companies in late-onset Pompe patients in Switzerland regardless of their clinical condition. Subsequent negotiations lead to the release of a national guideline of the management of late-onset Pompe disease. Initiation and limitation of ERT is outlined in a national Pompe registry. Reimbursement criteria are defined and individual efficacy of ERT with rhGAA is continuously monitored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Proteomics approaches to cardiovascular biology and disease hold the promise of identifying specific proteins and peptides or modification thereof to assist in the identification of novel biomarkers. METHOD: By using surface-enhanced laser desorption and ionization time of flight mass spectroscopy (SELDI-TOF-MS) serum peptide and protein patterns were detected enabling to discriminate between postmenopausal women with and without hormone replacement therapy (HRT). RESULTS: Serum of 13 HRT and 27 control subjects was analyzed and 42 peptides and proteins could be tentatively identified based on their molecular weight and binding characteristics on the chip surface. By using decision tree-based Biomarker Patternstrade mark Software classification and regression analysis a discriminatory function was developed allowing to distinguish between HRT women and controls correctly and, thus, yielding a sensitivity of 100% and a specificity of 100%. The results show that peptide and protein patterns have the potential to deliver novel biomarkers as well as pinpointing targets for improved treatment. The biomarkers obtained represent a promising tool to discriminate between HRT users and non-users. CONCLUSION: According to a tentative identification of the markers by their molecular weight and binding characteristics, most of them appear to be part of the inflammation induced acute-phase response

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND There is great variability for the type of anaesthesia used during TAVI, with no clear consensus coming from comparative studies or guidelines. We sought to detect regional differences in the anaesthetic management of patients undergoing transcatheter aortic valve implantation (TAVI) in Europe and to evaluate the relationship between type of anaesthesia and in-hospital and 1year outcome. METHODS Between January 2011 and May 2012 the Sentinel European TAVI Pilot Registry enrolled 2807 patients treated via a transfemoral approach using either local (LA-group, 1095 patients, 39%) or general anaesthesia (GA-group, 1712 patients, 61%). RESULTS A wide variation in LA use was evident amongst the 10 participating countries. The use of LA has increased over time (from a mean of 37.5% of procedures in the first year, to 57% in last 6months, p<0.01). MI, major stroke as well as in-hospital death rate (7.0% LA vs 5.3% GA, p=0.053) had a similar incidence between groups, confirmed in multivariate regression analysis after adjusting for confounders. Dividing our population in tertiles according to the Log-EuroSCORE we found similar mortality under LA, whilst mortality was higher in the highest risk tertile under GA. Survival at 1year, compared by Kaplan-Meier analysis, was similar between groups (log-rank: p=0.1505). CONCLUSIONS Selection of anaesthesia appears to be more influenced by national practice and operator preference than patient characteristics. In the absence of an observed difference in outcomes for either approach, there is no compelling argument to suggest that operators and centres should change their anaesthetic practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transapical transcatheter aortic valve implantation (TA-TAVI) is the recognized first choice surgical TAVI access. Expansion of this well-established treatment modality with subsequent broader patient inclusion has accelerated development of second-generation TA-TAVI devices. The Swiss ACURATE TA Symetis valve allows for excellent anatomical positioning, resulting in a very low incidence of paravalvular leaks. The self-expanding stent features an hourglass shape to wedge the native aortic valve annulus. A specially designed delivery system facilitates controlled release aided by tactile operator feedback. The ACURATE TA valve made of three native porcine non-coronary leaflets has received CE approval in September 2011. Since then, this valve is the third most frequently implanted TAVI device with over 1200 implants in Europe and South America. Results from the Symetis ACURATE TA™ Valve Implantation ('SAVI') Registry showed a procedural success rate of 98.0% and a survival rate of 93.2% at 30 days. This presentation provides technical considerations and detailed procedural aspects of device implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) has demonstrated the feasibility of treating valvular heart disease with transcatheter therapy. On the back of this success, various transcatheter concepts are being evaluated to treat other valvular disease, especially mitral regurgitation (MR). The concepts currently approved to treat MR replicate surgical mitral valve repair. However, most of them cannot eliminate MR completely. Similar to TAVI, a transcatheter mitral valve implantation may provide a valuable alternative. The FORTIS transcatheter mitral valve (Edwards Lifesciences, Irvine, CA, USA) is a self-expanding device implanted via a transapical approach. We describe our experience and early results in the first five patients treated on compassionate grounds. We also describe the details of the device, selection criteria and technical details of implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The use of transcatheter mitral valve repair (TMVR) has gained widespread acceptance in Europe, but data on immediate success, safety, and long-term echocardiographic follow-up in real-world patients are still limited. OBJECTIVES The aim of this multinational registry is to present a real-world overview of TMVR use in Europe. METHODS The Transcatheter Valve Treatment Sentinel Pilot Registry is a prospective, independent, consecutive collection of individual patient data. RESULTS A total of 628 patients (mean age 74.2 ± 9.7 years, 63.1% men) underwent TMVR between January 2011 and December 2012 in 25 centers in 8 European countries. The prevalent pathogenesis was functional mitral regurgitation (FMR) (n = 452 [72.0%]). The majority of patients (85.5%) were highly symptomatic (New York Heart Association functional class III or higher), with a high logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) (20.4 ± 16.7%). Acute procedural success was high (95.4%) and similar in FMR and degenerative mitral regurgitation (p = 0.662). One clip was implanted in 61.4% of patients. In-hospital mortality was low (2.9%), without significant differences between groups. The estimated 1-year mortality was 15.3%, which was similar for FMR and degenerative mitral regurgitation. The estimated 1-year rate of rehospitalization because of heart failure was 22.8%, significantly higher in the FMR group (25.8% vs. 12.0%, p[log-rank] = 0.009). Paired echocardiographic data from the 1-year follow-up, available for 368 consecutive patients in 15 centers, showed a persistent reduction in the degree of mitral regurgitation at 1 year (6.0% of patients with severe mitral regurgitation). CONCLUSIONS This independent, contemporary registry shows that TMVR is associated with high immediate success, low complication rates, and sustained 1-year reduction of the severity of mitral regurgitation and improvement of clinical symptoms.