969 resultados para Underground cables


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Brazil, the large quantities of solid waste produced are out of step with public policies, technological developments, and government budgets for the division. In small municipalities, the common lack of technological knowledge and financial conditions for suitable waste disposal has resulted in a large number of illegal dumps. Therefore, small sanitary landfill facilities are working with simplified operations focusing on cost reduction and meeting the economic and technological standards of the city without endangering the environment or public health. Currently, this activity is regulated at a federal level although there is some uncertainty regarding the risk of soil and aquifer contamination as theses facilities do not employ liners. Thus, this work evaluates a small landfill to identify changes in soil and groundwater using geotechnical parameters, monitoring wells, and geophysical tests performed by electrical profiling. It is verified that based on current conditions, no contaminants have migrated via underground water aquifers, and overall no significant changes have occurred in the soil. It is concluded that, despite its simplicity, the method investigated is a viable alternative for the final disposal of municipal solid waste from small cities, especially in developing countries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increasing demand for electrical energy and the difficulties involved in installing new transmission lines presents a global challenge. Transmission line cables need to conduct more current, which creates the problem of excessive cable sag and limits the distance between towers. Therefore, it is necessary to develop new cables that have low thermal expansion coefficients, low densities, and high resistance to mechanical stress and corrosion. Continuous fiber-reinforced polymers are now widely used in many industries, including electrical utilities, and provide properties that are superior to those of traditional ACSR (aluminum conductor steel reinforced) cables. Although composite core cables show good performance in terms of corrosion, the contact of carbon fibers with aluminum promotes galvanic corrosion, which compromises mechanical performance. In this work, three different fiber coatings were tested (phenol formaldehyde resin, epoxy-based resin, and epoxy resin with polyester braiding), with measurements of the galvanic current. The use of epoxy resin combined with polyester braiding provided the best inhibition of galvanic corrosion. Investigation of thermal stability revealed that use of phenol formaldehyde resin resulted in a higher glass transition temperature. On the other hand, a post-cure process applied to epoxy-based resin enabled it to achieve glass transition temperatures of up to 200 degrees C. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The contamination of underground waters is a subject of great importance, since a lot of people use this kind of source for public supply. This paperwork manages with how gas stations can contaminate these waters and what are some remediation techniques, used nowadays to solve this problem. The contamination caused by the gas stations can have its origin in the underground storage tanks when they suffer corrosion and show leaking problems. It’s a topic of great relevance, because the hydrocarbons derivated from petroleum present in the fuels can stay for a long time in the environment. Besides that, an analyses of the risk of contamination by gas stations in the city of Rio Claro was made based on three parameters: density of the gas stations, depth of the underground water and hydraulic conductivity. To achieve such goal, maps were elaborated considering those parameters individually and considering the three of them together. Analyzing those maps, it was concluded see that the spots that represent the biggest risks of contamination in Rio Claro are located southeast and center-west.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research aimed to evaluate the quality of “Aquifer Guarani’s” waters in the context of the current legislation related to the radioactive aspects, besides correlating the values obtained with chemical data already available, seeking to make an integrated analysis of the data in order to establish possible tendencies with directions of underground flow. The determinations of the total radioactivity beta and alpha were accomplished through the employment of the available infrastructure at the LABIDRO – Laboratory of Isotope and Hydrochemistry of the Petrology and Metallogeny of UNESP’s Institute of Geosciences and Exact Sciences, largely implanted through resources supplied by FAPESP and CNPq. The systems were gauged for the determinations of interest with tracer of known activity. Preliminaries tests were accomplished with high radioactivity samples of water to check the applicability of the methods. It was ended that the waters analyzed possess low radioactivity, as much alpha as total beta, and, therefore, they are appropriate for the human consumption; that there is not lineal relationship between the obtained data and the chemical data already available; and that the direction of the underground flow of the Aquifer doesn't check any tendency to the generated data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to analyze data from a Natural Electric Potential landfill type ditch located in Cordeirópolis (SP). The procedure measures initially involved the assembly and installation of an apparatus cables, sensors and drain geophysical measurements and flow rate of biogas in a ditch later filled by solid waste. Biogas is a product of degradation of organic matter in waste by the action of microorganisms in an anaerobic environment. Its features high methane content in the gas potentially usable as fuel in energy generation systems or steam. The study area is characterized by clayey soil composition change from the diabase sill correlated to the event Serra Geral Formation siltstones overlapping Tatuí with groundwater level site around 50m. The cables were installed vertically in parallel with drain gas manifold, which allowed the collection of data by the technique geophysical logging every 15 days over a period of eight months. For data analysis we used four parameters in the study, the closing time of the ditch, natural electric potential, the flow velocity of biogas and rain. With the tabulated data plots were constructed for each collection day showing values in the range of the cable is in contact with waste (200 cm - 400 cm) and range of the cable in contact with the soil (600 cm - 800 cm). Subsequently graphs were generated with the period of eight months to analyze the data tabulated. A statistical correlation data, which show the influence of rainfall on the production of biogas. The results were satisfactory and demonstrated the feasibility of the research method in studies for the feasibility analysis for the capture of biogas energy

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Aquidauana Formation is characterized by sandstones of variable granulation, mudstones and diamectites abundant in clay, typical colors like brick red (vermelho tijolo) of glacial, fluvial and lacustrine origin. It’s chronostratigraphic equivalent to the Itarará group from the Neo Carboniferous age, that under the exploratory view, such units represent important intervals in the basin, occurring together with them minerals as well as energy resources as petroleum, underground water and coal – what requires a great paleogeography and stratigraphy knowledge for its exploration. By gathering information from the columnar sections of the area, it was possible to characterize the sedimentary facies, the stacking pattern as well as the association. It was also made an attempt of stratigraphic correlation, which showed great difficulties since glacial environments present a great lateral discontinuity of the facies besides the complex relationship process of formation. As a result, it was obtained 8 sedimentary facies, the lateral and vertical relations and genesis process. It is proposed that the sedimentary environment in the study area is the fluvio glacial, characterized by alluvial systems formed by defrosted water which transport the sediments that are deposited in plains in front of the glacier (distal outwash). Petrographic thin section analysis showed that the transportation process was ineffective. The grains present punctual to lobular contacts, characterizing good porosity and permeability to the rock, varying these qualities according to more or less existence of matrix. The presence of Iron Oxide deposited between the recrystallization border and feldspathic mineral indicates that this rock has possibly presented a primary rubefaction, intensified by alkaline fluid percolation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to prove the economic feasibility of the installation of mechanical compression chillers on plastic injection molding machines in order to reduce the production cycle time of toothbrush cables in a specific case study. This evidence was confirmed by the comparative analysis of the system replaced and the new system installed. The old system had only one closed loop cooling tower which pumped chilled water to the injection molds, and the new system has the same tower sending cold water to the condensers of individual chillers installed on each injection machine. We conducted an analysis of energy efficiency in each system, showing that in terms of thermal efficiency virtually nothing has changed, but in terms of electricity demand the new system consumes 60.3 kW more. We conducted an analysis of machine productivity for both systems, showing a much higher productivity of the new system due to reduced cycle times caused by the presence of chillers and their greater cooling capacities. Equipped with data such as electricity rates, increases in operating costs and initial investments, the increase in consumption and demand of electricity plus the cycle time reduction were also calculated over so the simple payback 1 year and 2 months was reached

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the increasing demand for electricity, the retraining of transmission lines is necessary despite environmental restrictions and crossings in densely populated areas to build new transmission and distribution lines. Solution is reuse the existent cables, replacing the old conductor cables for new cables with higher capacity power transmission, and control of sag installed. The increasing demand for electrical power has increased the electric current on the wires and therefore, it must bear out temperatures of 150°C or more, without the risk of the increasing sag beyond the established limits. In the case of long crossings or densely populated areas, sag is due to high weight of the cable on clearance. The cable type determines the weight, sag, height and the towers dimensions, which are the items that most influence the investment of the transmission line. Hence, to reduce both cost of investment and maintenance of the line, the use of a lighter cable can reduce both number and the height of the towers, with financial return on short and long term. Therefore, in order to increase the amount of transmitted energy and reduce the number of built towers and sag, is recommended in the current work substitute the current core material (steel or aluminium) for alternatives alloys or new materials, in this case a composite, which has low density, elevated stiffness (elasticity module), thus apply the pultruded carbon fiber with epoxy resin as matrix systems and perform the study of the kinetics of degradation by thermogravimetric analysis (TGA), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC), according to their respective standards

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The lack of proper planning in intervention works of runoff water on rural properties and rural public roads leads to economic damage and loss of environmental quality. The impact of the action without technical base is soil erosion, siltation of water sources, loss of the quality and availability of water, invalidating areas for cultivation and livestock. The conservation of headwaters requires beyond regeneration of the environmental characteristics the repair and management of the degraded watercourse in order to control erosion. This graduate work in Environmental Engineering from Universidade Estadual Paulista Julio de Mesquita Filho - UNESP Presidente Prudente proposes a headwater recuperation and management in rural area of Álvares Machado municipality, São Paulo State, through the method of deep drainage applied to the case of a rural road near the outcrop of water. This technique consists in the installation of draining structures in sub-areas of the road surface, or sub-gutter and/or in the platform border in order to conduct the underground flow of water and reduce the loss of sediment in water flow. Therefore, was performed a historic study of use and occupation of land in the municipality of Álvares Machado, portraying transformations of the landscape caused by human action. Geology, geomorphology, pedology and hydrogeology data were collected from the study area in order to establish the conditions that led into the current situation of degradation and formulate an effective intervention strategy for civil works