The surface oxidation of UO2 sintered plates at 170-275 ° C was studied in situ by high temperature X-ray diffractometry. At very low oxygen concentration, UO2 is oxidized to U4O9, while at 300°C and argon-20 vol% oxygen it is oxidized up to U3O7. X-ray diffraction profiles of the UO2, U4O9 and U3O7 phases were well characterized during the transformations. The activation energy for the transformation of UO2 to U4O9, obtained from X-ray diffraction data, was found to be 117 ± 9 kJ/mol and 90 ± 14 kJ/mol for the β-(311) and α-(200) reflections, respectively. © 1991.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electron-diffraction pattern for two slits with magnetic flux confined to an inaccessible region between them is calculated. The Aharonov-Bohm effect gives a diffraction pattern that is asymmetric but has a symmetric envelope. In general, both the expected displacement and the kinetic momentum of the electron are nonzero as a consequence of the asymmetry. Nevertheless, Ehrenfests theorems and the conservation of momentum are satisfied. © 1992 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural changes induced by ultrasound during the aging of the aluminum monohydroxide (boehmite) were studied by means of X-ray diffraction (XRD) and nitrogen adsorption. The BET surface area and the pore volume of the ultrasound stimulated hydroxide (HU) are about 40% less than those of the non-stimulated one (HS). The mean pore size practically does not change, while the mean crystallite size (L) is about 25% greater in the HU system. The increase of L alone is not enough to account for the surface area diminution, suggesting that the sonication also induces compaction by elimination of some porosity. The sonication of the precursor hydroxide does not seem to play an apparent role in the structural properties of the resulting calcinated γ-alumina. © 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemoglobin remains, despite the enormous amount of research involving this molecule, as a prototype for allosteric models and new conformations. Functional studies carried out on Hemoglobin-I from the South-American Catfish Liposarcus anisitsi [1] suggest the existence of conformational states beyond those already described for human hemoglobin, which could be confirmed crystallographically. The present work represents the initial steps towards that goal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diphasic gel in the mullite composition was prepared from a colloidal sol of boehmite mixed with a hydrolyzed tetraethoxisilane (TEOS) solution. The boehmite sol was obtained by peptization of a poorly crystallized or very small mean crystallite size (∼34 Å) precipitate, resulting from the reaction between solutions of aluminum sulfate and sodium hydroxide. Ultrasound was utilized in the processes of the TEOS hydrolysis and the boehmite peptization, and also for complete homogenization of the mixture to gel. The wet gel is almost clear and monolithic. The gel transparency is lost on drying, when syneresis has ended, so that the interlinked pore structure starts to empty and is recovered upon water re-absorption. Cracking closely accompanies this critical drying process. Differential thermal analysis (DTA) and X-ray diffraction (XRD) show that the solid structure of the gel is composed of an amorphous silica phase, as a matrix, and a colloidal sized crystalline phase of boehmite. Upon heat treatment, the boehmite phase within the gel closely follows the same transition sequence as in pure alumina shifted towards higher temperatures. Orthorhombic mullite formation was detected at 1300°C. © 1998 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work it is introduced a new approach to calculate the density of liquids in terms of the energies of the acoustic signals. This method is compared to other methods in the time domain (peak-to-peak amplitudes) and frequency domain magnitudes at a single frequency. It is used a measurement cell based on a multiple reflection technique, and it is developed an acoustic model for the cell. Simulations and experiments using several liquids are presented, showing that the energy method a less sensitive to noise than the other techniques. The relative errors in the density are smaller than 0.2% when compared to the values measured with a pycnometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an ultrasonic method to measure small concentrations of water in lubricating oil. It uses an ultrasonic measurement cell composed by a piezoceramic emitter (5 and 10 MHz), and a large aperture PVDF receiver that eliminates diffraction effects. The propagation velocity, attenuation coefficient and density of several samples of water-in-oil emulsion were measured. The concentrations of water of the samples were in the range of 0 to 5% in volume, and the results showed that these low concentrations can be discriminated within a resolution of 0.2% in the studied range, using the measurement of the propagation velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ultrasonic densitometer is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 to 40°C temperature range. Results are compared to tabulated values in the case of distilled water, showing accuracy of 0.07% for the propagation velocity. Density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% under thermal gradient conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This review of the literature intends to evaluate the effect of brushes with high frequency motion when compared with manual toothbrushes regarding the indices of plaque and gingival bleeding. METHODS: Patients presenting gingivitis and/or chronic periodontitis were evaluated in addition to patients having osseointegrated implants and fixed orthodontic appliances. Pertinent literature was reviewed to select articles according to previously defined inclusion criteria. RESULTS: In the assessed studies results showed significant decreases in plaque and gingival indices by utilization of both types of brushes. However, in the selected studies where sonic brushes were tested in orthodontic and dental implant patients there was a more significant decrease in the indices. Furthermore, there was no indication of gingival recession attributed to product use. CONCLUSION: Future studies with a more homogeneous methodology and better experiment designs will be needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several studies have reported the benefits of sonic and/or ultrasonic instrumentation for root debridement, with most of them focusing on changes in periodontal clinical parameters. The present study investigated possible alterations in the tensile bond strength of crowns cemented with zinc phosphate cement to natural teeth after ultrasonic instrumentation. Forty recently extracted intact human third molars were selected, cleaned and stored in physiologic serum at 4°C. They received standard preparations, at a 16° convergence angle, and AgPd alloy crowns. The crowns were cemented with zinc phosphate cement and then divided into four groups of 10 teeth each. Each group was then subdivided into two subgroups, with one of the subgroups being submitted to 5,000 thermal cycles ranging from 55 ± 2 to 5 ± 2°C, while the other was not. Each group was submitted to ultrasonic instrumentation for different periods of time: group 1 - 0 min (control), group 2 - 5 min, group 3 - 10 min, and group 4 - 15 min. Tensile bond strength tests were performed with an Instron testing machine (model 4310). Statistical analysis was performed using ANOVA and Tukey's test at the 5% level of significance. A significant reduction in the tensile bond strength of crowns cemented with zinc phosphate and submitted to thermal cycles was observed at 15 min (196.75 N versus 0 min = 452.01 N, 5 min = 444.23 N and 10 min = 470.85 N). Thermal cycling and ultrasonic instrumentation for 15 min caused a significant reduction in tensile bond strength (p < .05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was to compare the dentin-pulp complex response to cavity preparation in human teeth using ultrasonic chemical vapor deposition (CVD) diamond tip and high-speed diamond bur. Class V buccal cavities were randomly prepared in 40 premolars from 14 patients aged 11 to 15 years. The cutting time was recorded and the cavities had the axial walls protected with gutta-percha and were filled with glass ionomer cement. The teeth were extracted at intervals of 0, 5, 10 and 20 days, and were decalcified, sectioned and stained by Hematoxylin & Eosin, Masson's Trichrome and Brown & Brenn techniques. The inflammatory response and cell disorganization were blindly evaluated by two examiners. The remaining dentin thickness (RDT) was measured by a linear scale using computer software. Statistical analysis by one-way ANOVA showed no statistically significant difference (P≤0.05) among the cavities prepared with either type of instrument, with mean RDT of 1132.50 mm. Cutting time and the pulp-dentin complex responses were analyzed statistically by Kruskal-Wallis and Dunn tests (P≤0.05). The ultrasonic CVD diamond tip took 5 times longer to prepare the cavities and there were no typical inflammatory pulp responses in cavities prepared with either type of cutting instrument, only mild to moderate cell disorganization was present. Even taking longer to cut the dental substrate, the ultrasonic CVD diamond tip produced similar pulp response compared to the conventional high-speed diamond bur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study used scanning electron microscopy (SEM) to evaluate the morphology and adhesion of blood components on root surfaces instrumented by curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser. One hundred samples from 25 teeth were divided into 5 groups: 1) Curettes; 2) Piezoelectric ultrasonic scaler; 3) Curettes plus piezoelectric ultrasonic scaler; 4) Er,Cr:YSGG laser; 5) Curettes plus Er,Cr:YSGG laser. Ten samples from each group were used for analysis of root morphology and the other 10 were used for analysis of adhesion of blood components on root surface. The results were analyzed statistically by the Kruskall-Wallis and Mann-Whitney tests with a significance level of 5%. The group treated with curettes showed smoother surfaces when compared to the groups were instrumented with piezoelectric ultrasonic scaler and the Er,Cr:YSGG laser. The surfaces instrumented with piezoelectric ultrasonic scaler and Er,Cr:YSGG laser, alone or in combination with hand scaling and root planing, did not differ significantly (p>0.05) among themselves. No statistically significant differences (p>0.05) among groups were found as to the adhesion of blood components on root surface. Ultrasonic instrumentation and Er,Cr:YSGG irradiation produced rougher root surfaces than the use of curettes, but there were no differences among treatments with respect to the adhesion of blood components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the effectiveness of ultrasonic activation of bleaching agents during ex vivo internal bleaching. Methodology: Fifty canine human teeth were artificially stained, root filled and divided into five groups (n = 10) that received SP - sodium perborate plus deionized water (control group), CP - 37% carbamide peroxide gel, CPUS - 37% carbamide peroxide gel plus ultrasonic application, HP - 35% hydrogen peroxide gel or HPUS - 35% hydrogen peroxide gel plus ultrasonic application. In groups CP and HP, the bleaching agent was left inside the pulp chamber for three applications of 10 min. In groups CPUS and HPUS, the same process was performed, but ultrasonic vibration was applied to the bleaching agent by an alloy tip for 30 s, with 30 s intervals. Two sessions were performed. The colour was measured initially and after each session by an intraoral dental spectrophotometer. The variation (Δ) of the colour parameters based on the CIELab system L*, a* and b*, and the colour alteration ΔE* were calculated after first and second section. Data were analysed by one-way anova and Tukey's test. Results: There was no significant difference amongst groups for ΔL*, Δa* and ΔE*, but there was a significant difference for Δb* in the first and second sessions (P = 0.0006 and 0.0016, respectively). After the first session, Δb* was significantly greater for groups HP and HPUS, without a significant difference between them. For the second session, group HPUS had the greatest Δb* values, but they were similar to groups HP and SP; group CP had the lowest values, which were similar to groups CPUS and SP. Conclusion: Ultrasonic activation of bleaching agents during ex vivo internal bleaching was no more effective than conventional internal bleaching procedures, without activation. © 2012 International Endodontic Journal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the excellent properties of mineral trioxide aggregate (MTA), the condensation technique may have some influence in its sealing ability. The purpose of this study was to compare the sealing ability of sonic and ultrasonic setting of MTA. Thirty-four extracted human teeth had their canals prepared and filled with Sealapex sealer and gutta-percha using the active lateral condensation technique. The teeth were rendered waterproof and apicoectomy performed at 3 mm from the apex. Root-end cavities (3.0 mm deep and 1.4 mm diameter) were prepared with diamond ultrasonic tips. The root-end cavities were filled with Pro-Root MTA® with ultrasonic vibration, sonic vibration or no vibration. The positive control group did not receive any material while the negative control group was totally rendered waterproof. After material set, the specimens were immersed in Rodhamine B for 24 h, under vacuum in the first 15 min, then washed, dried and split longitudinally for evaluating the infiltration at the dentin/material interface. Data were analyzed using ANOVA and Tukey's tests at 5% significance level. Sonic vibration promoted the lowest infiltration values (p<0.05). It was concluded that sonic vibration could be considered an efficient aid to improve the sealing ability of MTA when used as root-end filling material.