872 resultados para Two-body abrasion


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA. METHODS In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups. RESULTS Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0). CONCLUSIONS Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg. KEY POINTS • 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over recent years, it has repeatedly been shown that optimal gaze strategies enhance motor control (e.g., Foulsham, 2015). However, little is known, whether, vice versa, visual performance can be improved by optimized motor control. Consequently, in two studies, we investigated visual performance as a function of motor control strategies and task parameters, respectively. In Experiment 1, 72 participants were tested on visual acuity (Landolt) and contrast sensitivity (Grating), while standing in two different postures (upright vs. squat) on a ZEPTOR-platform that vibrated at four different frequencies (0, 4, 8, 12 Hz). After each test, perceived exertion (Borg) was assessed. Significant interactions were revealed for both tests, Landolt: F(3,213)=13.25, p<.01, ηp2=.16, Grating: F(3,213)=4.27, p<.01, ηp2=.06, elucidating a larger loss of acuity/contrast sensitivity with increasing frequencies for the upright compared with the squat posture. For perceived exertion, however, a diametrical interaction for frequency was found for acuity, F(3,213)=7.45, p<.01, ηp2=.09, and contrast sensitivity, F(3,213)=7.08, p < .01, ηp2=.09, substantiating that the impaired visual performance cannot be attributed to exertion. Consequently, the squat posture could permit better head and, hence, gaze stabilization. In Experiment 2, 64 participants performed the same tests while standing in a squat position on a ski-simulator, which vibrated with two different frequencies (2.4, 3.6 Hz) and amplitudes (50, 100 mm) in a predictable or unpredictable manner. Control strategies were identified by tracking segmental motion, which allows to derive damping characteristics. Considerable main effects were found for frequency, all F’s(1,52)>10.31, all p’s<.01, all ηp2’s>.16, as well as, in the acuity test, for predictability, F(1,52)=10.31, p<.01, ηp2=.17, and by tendency for amplitude, F(1,52)=3.53, p=.06, ηp2=.06. A significant correlation between the damping amplitude in the knee joint and the performance drop in visual acuity, r=-.97, p<.001, again points towards the importance of motor control strategies to maintain optimal visual performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

After attending this presentation, attendees will: (1) understand how body height from computed tomography data can be estimated; and, (2) gain knowledge about the accuracy of estimated body height and limitations. The presentation will impact the forensic science community by providing knowledge and competence which will enable attendees to develop formulas for single bones to reconstruct body height using postmortem Computer Tomography (p-CT) data. The estimation of Body Height (BH) is an important component of the identification of corpses and skeletal remains. Stature can be estimated with relative accuracy via the measurement of long bones, such as the femora. Compared to time-consuming maceration procedures, p-CT allows fast and simple measurements of bones. This study undertook four objectives concerning the accuracy of BH estimation via p-CT: (1) accuracy between measurements on native bone and p-CT imaged bone (F1 according to Martin 1914); (2) intra-observer p-CT measurement precision; (3) accuracy between formula-based estimation of the BH and conventional body length measurement during autopsy; and, (4) accuracy of different estimation formulas available.1 In the first step, the accuracy of measurements in the CT compared to those obtained using an osteometric board was evaluated on the basis of eight defleshed femora. Then the femora of 83 female and 144 male corpses of a Swiss population for which p-CTs had been performed, were measured at the Institute of Forensic Medicine in Bern. After two months, 20 individuals were measured again in order to assess the intraobserver error. The mean age of the men was 53±17 years and that of the women was 61±20 years. Additionally, the body length of the corpses was measured conventionally. The mean body length was 176.6±7.2cm for men and 163.6±7.8cm for women. The images that were obtained using a six-slice CT were reconstructed with a slice thickness of 1.25mm. Analysis and measurements of CT images were performed on a multipurpose workstation. As a forensic standard procedure, stature was estimated by means of the regression equations by Penning & Riepert developed on a Southern German population and for comparison, also those referenced by Trotter & Gleser “American White.”2,3 All statistical tests were performed with a statistical software. No significant differences were found between the CT and osteometric board measurements. The double p-CT measurement of 20 individuals resulted in an absolute intra-observer difference of 0.4±0.3mm. For both sexes, the correlation between the body length and the estimated BH using the F1 measurements was highly significant. The correlation coefficient was slightly higher for women. The differences in accuracy of the different formulas were small. While the errors of BH estimation were generally ±4.5–5.0cm, the consideration of age led to an increase in accuracy of a few millimetres to about 1cm. BH estimations according to Penning & Riepert and Trotter & Gleser were slightly more accurate when age-at-death was taken into account.2,3 That way, stature estimations in the group of individuals older than 60 years were improved by about 2.4cm and 3.1cm.2,3 The error of estimation is therefore about a third of the common ±4.7cm error range. Femur measurements in p-CT allow very accurate BH estimations. Estimations according to Penning led to good results that (barely) come closer to the true value than the frequently used formulas by Trotter & Gleser “American White.”2,3 Therefore, the formulas by Penning & Riepert are also validated for this substantial recent Swiss population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Denosumab reduced the incidence of new fractures in postmenopausal women with osteoporosis by 68% at the spine and 40% at the hip over 36 months compared with placebo in the FREEDOM study. This efficacy was supported by improvements from baseline in vertebral (18.2%) strength in axial compression and femoral (8.6%) strength in sideways fall configuration at 36 months, estimated in Newtons by an established voxel-based finite element (FE) methodology. Since FE analyses rely on the choice of meshes, material properties, and boundary conditions, the aim of this study was to independently confirm and compare the effects of denosumab on vertebral and femoral strength during the FREEDOM trial using an alternative smooth FE methodology. Unlike the previous FE study, effects on femoral strength in physiological stance configuration were also examined. QCT data for the proximal femur and two lumbar vertebrae were analyzed by smooth FE methodology at baseline, 12, 24, and 36 months for 51 treated (denosumab) and 47 control (placebo) subjects. QCT images were segmented and converted into smooth FE models to compute bone strength. L1 and L2 vertebral bodies were virtually loaded in axial compression and the proximal femora in both fall and stance configurations. Denosumab increased vertebral body strength by 10.8%, 14.0%, and 17.4% from baseline at 12, 24, and 36 months, respectively (p < 0.0001). Denosumab also increased femoral strength in the fall configuration by 4.3%, 5.1%, and 7.2% from baseline at 12, 24, and 36 months, respectively (p < 0.0001). Similar improvements were observed in the stance configuration with increases of 4.2%, 5.2%, and 5.2% from baseline (p ≤ 0.0007). Differences between the increasing strengths with denosumab and the decreasing strengths with placebo were significant starting at 12 months (vertebral and femoral fall) or 24 months (femoral stance). Using an alternative smooth FE methodology, we confirmed the significant improvements in vertebral body and proximal femur strength previously observed with denosumab. Estimated increases in strength with denosumab and decreases with placebo were highly consistent between both FE techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Treatment of displaced tarsal navicular body fractures usually consists of open reduction and internal fixation. However, there is little literature reporting results of this treatment and correlation to fracture severity. METHODS We report the results of 24 patients treated in our institution over a 12-year period. Primary outcome measurements were Visual-Analogue-Scale Foot and Ankle score (VAS-FA), AOFAS midfoot score, and talonavicular osteoarthritis at final follow-up. According to a new classification system reflecting talonavicular joint damage, 2-part fractures were classified as type I, multifragmentary fractures as type II, and fractures with talonavicular joint dislocation and/or concomitant talar head fractures as type III. Spearman's coefficients tested this classification's correlation with the primary outcome measurements. Mean patient age was 33 (range 16-61) years and mean follow-up duration 73 (range 24-159) months. RESULTS Average VAS-FA score was 74.7 (standard deviation [SD] 16.9), and average AOFAS midfoot score was 83.8 (SD = 12.8). Final radiographs showed no talonavicular arthritis in 5 patients, grade 1 in 7, grade 2 in 3, grade 3 in 6, and grade 4 in 1 patient. Two patients had secondary or spontaneous talonavicular fusion. Spearman coefficients showed strong correlation of the classification system with VAS-FA score (r = -0.663, P < .005) and talonavicular arthritis (r = 0.600, P = .003), and moderate correlation with AOFAS score (r = -.509, P = .011). CONCLUSION At midterm follow-up, open reduction and internal fixation of navicular body fractures led to good clinical outcome but was closely related to fracture severity. A new classification based on the degree of talonavicular joint damage showed close correlation to clinical and radiologic outcome. LEVEL OF EVIDENCE Level IV, retrospective case series.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the effect of airborne-particle abrasion or diamond bur preparation as pretreatment steps of non-carious cervical root dentin regarding substance loss and bond strength. Methods: 45 dentin specimens produced from crowns of extracted human incisors by grinding the labial surfaces with silicon carbide papers (control) were treated with one of three adhesive systems (Group 1A-C; A: OptiBond FL, B: Clearfil SE Bond, or C: Scotchbond Universal; n=15/adhesive system). Another 135 dentin specimens (n=15/group) produced from the labial, non-carious cervical root part of extracted human incisors were treated with one of the adhesive systems after either no pre-treatment (Group 2A-C), pre-treatment with airborne-particle abrasion (CoJet Prep and 50 µm aluminum oxide powder; Group 3A-C), or pre-treatment with diamond bur preparation (40 µm grit size; Group 4A-C). Substance loss caused by the pre-treatment was measured in Groups 3 and 4. After treatment with the adhesive systems, resin composite was applied and all specimens were stored (37°C, 100% humidity, 24 hours) until measurement of microshear bond strength (µSBS). Data were analyzed with a nonparametric ANOVA followed by Kruskal-Wallis and Wilcoxon rank sum tests (level of significance: alpha=0.05). Results: Overall substance loss was significantly lower in Group 3 (median: 19 µm) than in Group 4 (median: 113 µm; p<0.0001). There were no significant differences in µSBS between the adhesive systems (A-C) in Group 1, Group 3, and Group 4 (p>=0.133). In Group 2, OptiBond FL (Group 2A) and Clearfil SE Bond (Group 2B) yielded significantly higher µSBS than Scotchbond Universal (Group 2C; p<=0.032). For OptiBond FL and Clearfil SE Bond, there were no significant differences in µSBS between the ground crown dentin and the non-carious cervical root dentin regardless of any pre-treatment of the latter (both p=0.661). For Scotchbond Universal, the µSBS to non-carious cervical root dentin without pre-treatment was significantly lower than to ground crown dentin and to non-carious cervical root dentin pre-treated with airborne-particle abrasion or diamond bur preparation p<=0.014).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). Materials and Methods: 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. Results: The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. Conclusion: The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT. Key Points: • The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %.• The diagnostic reference standard MSCT is the preferred and reliable imaging modality.• LS may be valuable for quick detection of extremity fractures. Citation Format: • Jöres APW., Heverhagen JT, Bonél H et al. Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. Fortschr Röntgenstr 2016; 188: 163 - 171.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The factors shaping cometary nuclei are still largely unknown, but could be the result of concurrent effects of evolutionary(1,2) and primordial processes(3,4). The peculiar bilobed shape of comet 67P/Churyumov-Gerasimenko may be the result of the fusion of two objects that were once separate or the result of a localized excavation by outgassing at the interface between the two lobes(5). Here we report that the comet's major lobe is enveloped by a nearly continuous set of strata, up to 650 metres thick, which are independent of an analogous stratified envelope on the minor lobe. Gravity vectors computed for the two lobes separately are closer to perpendicular to the strata than those calculated for the entire nucleus and adjacent to the neck separating the two lobes. Therefore comet 67P/Churyumov-Gerasimenko is an accreted body of two distinct objects with 'onion-like' stratification, which formed before they merged. We conclude that gentle, low-velocity collisions occurred between two fully formed kilometre-sized cometesimals in the early stages of the Solar System. The notable structural similarities between the two lobes of comet 67P/Churyumov-Gerasimenko indicate that the early-forming cometesimals experienced similar primordial stratified accretion, even though they formed independently.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous studies of normal children have linked body fat but not body fat distribution (BFD), to higher blood pressures, lipids, and insulin resistance (Berenson et al., 1988) BFD is a well-established risk factor for cardiovascular disease in adults (Björntorp, 1988). This study investigates the relation of BFD and serum lipids at baseline in children from Project HeartBeat!, a study of the growth and development of cardiovascular risk factors in 678 children in three cohorts measured initially at ages 8, 11, and 14 years. Initially, two of four indices of BFD were significantly related to the lipids: ratio of upper to lower body skinfolds (ln US:LS) and conicity (C Index). A factor analysis reduced the information in the serum lipids to two vectors: (1) total cholesterol + LDL-cholesterol and (2) HDL-cholesterol − triglycerides, which together accounted for 85% of the lipid variation. Using each serum lipid and vector as separate dependent variables, linear and quadratic regression models were constructed to examine the predictive ability of the two BFD variables, controlling for total body fat, gender, ethnicity (Black, non-Black) and maturation. Linear models provided an acceptable fit. Percent body fat (%BF) was a significant predictor in each and every lipid model, independent of age, maturation, or ethnicity (p ≤ 0.05). No BFD variable entered the equation for total or LDL-cholesterol, although there was a significant maturity by BFD interaction for LDL (ln US:LS was a significant predictor in more mature individuals). Both %BF and BFD (by way of Conicity) were significant predictors of HDL-cholesterol and triglycerides (p ≤ 0.01). All models were statistically significant at a high level (p ≤ 0.01), but adjusted R 2's for all models were low (0.05–0.15). Body fat distribution is a significant predictor of lipids in normal children, but secondarily to %BF, and for LDL-cholesterol in particular, the relation is dependent on maturity status. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Caenorhabditis elegans germline is an excellent model system for studying meiosis, as the gonad contains germ cells in all stages of meiosis I prophase in a linear temporal and spatial pattern. To form healthy gametes, many events must be coordinated. Failure of any step in the process can reduce fertility. Here, we describe a C. elegans Germinal Center Kinase, GCK-1, that is essential for the accurate progression of germ cells through meiosis I prophase. In the absence of GCK-1, germ cells undergo precocious maturation due to the activation of a specific MAP kinase isoform. Furthermore, GCK-1 localizes to P-bodies, RNP particles that have been implicated in RNA degradation and translational control. Like two other components of C. elegans germline P-bodies, GCK-1 functions to limit physiological germ cell apoptosis. This is the first study to identify a role for a GCK-III kinase in metazoan germ cell development and to link P-body function with MAP kinase activation and germ cell maturation. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prevalence of obesity has increased sharply in the United States since the mid 1970's. Obese women who become pregnant are at increased risk of pregnancy complications for both mother and fetus. This study assessed whether women in higher body mass index (BMI) categories engage in the preventive behaviors of contraception more frequently than normal weight women. It also evaluated the type of contraception used by both obese and normal weight women. The study used cross-sectional data from 7 states participating in the Family Planning Module of the 2006 Behavioral Risk Factor Surveillance System (BRFSS). The Behavioral Risk Factor Surveillance System survey is an annual random digit dialed telephone survey of the non-institutionalized civilian population aged 18 years and older. The Family Planning Module was administered by Arizona, Kentucky, Minnesota, Missouri, Montana, Oregon, and Wisconsin. Of the 4,757 women who participated in the Family Planning Module, 2,244 (53.2%) were normal weight, 1,202 (25.6%) were overweight, and 1,072 (21.2%) were obese. The majority of these women 4,115 (86.2%) reported using some type of contraception to prevent pregnancy. Six hundred forty two women (13.8%) stated they did not use any type of contraception to prevent pregnancy. Within body mass index categories, 14% of normal weight women, 13% of overweight women, and 13.4% of obese women did not use any type of contraception. Neither the bivariate analysis nor the logistic regressions found body mass index categories to be statistically associated with contraceptive use. The relationship between body mass index categories and contraceptive method was found to be statistically significant. The predictive probability graph found that women at all levels of BMI have a lower probability of using barrier contraception methods as compared to procedural and hormonal methods. Hormonal contraception methods have the highest probability of use for women with a BMI of 15 to 25. In contrast, the probability of using procedural contraception methods is relatively flat and less than hormonal methods for BMI between 15 and 25. However, the probability of using procedural contraception increases dramatically with a BMI greater than 25. At a BMI greater than 42, women have a greater than 50% probability of using procedural contraception. Although a relationship between body mass index and contraception use was not found, contraception method was found to be associated with body mass index. The reasons why normal weight women prefer hormonal contraception while overweight/obese women are more likely to use procedural methods needs to be explored. By understanding the relationship between obesity and contraception, we can hopefully decrease unintended pregnancies and overall improve pregnancy related health outcomes. To determine if relationships between contraception use/type and body mass index exist, further research needs to be conducted on a national level. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Risk factors underlying the development of Barrett's esophagus (BE) are poorly understood. Recent studies have examined the association between elevated body mass index (BMI) and BE with conflicting results. A systematic review of literature was performed to study this association.^ Methods. Cross-sectional, case control and cohort studies published through April 2007 meeting strict inclusion and exclusion criteria were included. A thorough data abstraction, including that of reported crude or adjusted odds ratios or mean BMI, was performed. Crude odds ratios were estimated from available information in 3 studies.^ Results. Of 630 publications identified by our search items, 59 were reviewed in detail and 12 included in the final analyses. 3 studies showed a statistically significant association between obesity and BE (30-32) while 2 studies found a statistically significant association between overweight and BE (31, 32). Two studies that reported BMI as a continuous variable found BMI in cases to be significantly higher than that in the comparison group (30, 32). Other studies failed to show an significant association between elevated BMI and BE.^ Conclusions. There is conflicting data regarding the association between elevated BMI and BE. It is important to identify other risk factors that in combination with elevated BMI may lead to BE. Further studies are needed to evaluate if the presence of reflux symptoms or any particular pattern of obesity, are independently associated with BE.^ Key words. Barrett's esophagus, obesity, Body Mass Index, gastroesophageal reflux disease, meta-analysis^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation examined body mass index (BMI) growth trajectories and the effects of gender, ethnicity, dietary intake, and physical activity (PA) on BMI growth trajectories among 3rd to 12th graders (9-18 years of age). Growth curve model analysis was performed using data from The Child and Adolescent Trial for Cardiovascular Health (CATCH) study. The study population included 2909 students who were followed up from grades 3-12. The main outcome was BMI at grades 3, 4, 5, 8, and 12. ^ The results revealed that BMI growth differed across two distinct developmental periods of childhood and adolescence. Rate of BMI growth was faster in middle childhood (9-11 years old or 3rd - 5th grades) than in adolescence (11-18 years old or 5th - 12th grades). Students with higher BMI at 3rd grade (baseline) had faster rates of BMI growth. Three groups of students with distinct BMI growth trajectories were identified: high, average, and low. ^ Black and Hispanic children were more likely to be in the groups with higher baseline BMI and faster rates of BMI growth over time. The effects of gender or ethnicity on BMI growth differed across the three groups. The effects of ethnicity on BMI growth were weakened as the children aged. The effects of gender on BMI growth were attenuated in the groups with a large proportion of black and Hispanic children, i.e., “high” or “average” BMI trajectory group. After controlling for gender, ethnicity, and age at baseline, in the “high BMI trajectory”, rate of yearly BMI growth in middle childhood increased 0.102 for every 500 Kcals increase (p=0.049). No significant effects of percentage of energy from total fat and saturated fat on BMI growth were found. Baseline BMI increased 0.041 for every 30 minutes increased in moderate-to-vigorous PA (MVPA) in the “low BMI trajectory”, while Baseline BMI decreased 0.345 for every 30 minutes increased in vigorous PA (VPA) in the “high BMI trajectory”. ^ Childhood overweight and obesity interventions should start at the earliest possible ages, prior to 3rd grade and continue through grade school. Interventions should focus on all children, but specifically black and Hispanic children, who are more likely to be highest at-risk. Promoting VPA earlier in childhood is important for preventing overweight and obesity among children and adolescents. Interventions should target total energy intake, rather than only percentage of energy from total fat or saturated fat. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Body fat distribution is a cardiovascular health risk factor in adults. Body fat distribution can be measured through various methods including anthropometry. It is not clear which anthropometric index is suitable for epidemiologic studies of fat distribution and cardiovascular disease. The purpose of the present study was to select a measure of body fat distribution from among a series of indices (those traditionally used in the literature and others constructed from the analysis) that is most highly correlated with lipid-related variables and is independent of overall fatness. Subjects were Mexican-American men and women (N = 1004) from a study of gallbladder disease in Starr County, Texas. Multivariate associations were sought between lipid profile measures (lipids, lipoproteins, and apolipoproteins) and two sets of anthropometric variables (4 circumferences and 6 skinfolds). This was done to assess the association between lipid-related measures and the two sets of anthropometric variables and guide the construction of indices.^ Two indices emerged from the analysis that seemed to be highly correlated with lipid profile measures independent of obesity. These indices are: 2*arm circumference-thigh skinfold in pre- and post-menopausal women and arm/thigh circumference ratio in men. Next, using the sum of all skinfolds to represent obesity and the selected body fat distribution indices, the following hypotheses were tested: (1) state of obesity and centrally/upper distributed body fat are equally predictive of lipids, lipoproteins and apolipoproteins, and (2) the correlation among the lipid-related measures is not altered by obesity and body fat distribution.^ With respect to the first hypothesis, the present study found that most lipids, lipoproteins and apolipoproteins were significantly associated with both overall fatness and anatomical location of body fat in both sex and menopausal groups. However, within men and post-menopausal women, certain lipid profile measures (triglyceride and HDLT among post-menopausal women and apos C-II, CIII, and E among men) had substantially higher correlation with body fat distribution as compared with overall fatness.^ With respect to the second hypothesis, both obesity and body fat distribution were found to alter the association among plasma lipid variables in men and women. There was a suggestion from the data that the pattern of correlations among men and post-menopausal women are more comparable. Among men correlations involving apo A-I, HDLT, and HDL$\sb2$ seemed greatly influenced by obesity, and A-II by fat distribution; among post-menopausal women correlations involving apos A-I and A-II were highly affected by the location of body fat.^ Thus, these data point out that not only can obesity and fat distribution affect levels of single measures, they also can markedly influence the pattern of relationship among measures. The fact that such changes are seen for both obesity and fat distribution is significant, since the indices employed were chosen because they were independent of one another. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Longitudinal principal components analyses on a combination of four subcutaneous skinfolds (biceps, triceps, subscapular and suprailiac) were performed using data from the London Longitudinal Growth Study. The main objectives were to discover at what age during growth sex differences in body fat distribution occur and to see if there is continuity in body fatness and body fat distribution from childhood into the adult status (18 years). The analyses were done for four age sectors (3mon-3yrs, 3yrs-8yrs, 8yrs-18yrs and 3yrs-18yrs). Longitudinal principal component one (LPC1) for each age interval in both sexes represents the population mean fat curve. Component two (LPC2) is a velocity of fatness component. Component three (LPC3) in the 3mon-3yrs age sector represents infant fat wave in both sexes. In the next two age sectors component three in males represents peaks and shifts in fat growth (change in velocity), while in females it represents body fat distribution. Component four (LPC4) in the same two age sectors is a reversal in the sexes of the patterns seen for component three, i.e., in males it is body fat distribution and in females velocity shifts. Components five and above represent more complicated patterns of change (multiple increases and decreases across the age interval). In both sexes there is strong tracking in fatness from middle childhood to adolescence. In males only there is also a low to moderate tracking of infant fat with middle to late childhood fat. These data are strongly supported in the literature. Several factors are known to predict adult fatness among the most important being previous levels of fatness (at earlier ages) and the age at rebound. In addition we found that the velocity of fat change in middle childhood was highly predictive of later fatness (r $\approx -$0.7), even more so than age at rebound (r $\approx -$0.5). In contrast to fatness (LPC1), body fat distribution (LPC3-LPC4) did not track well even though significant components of body fat distribution occur at each age. Tracking of body fat distribution was higher in females than males. Sex differences in body fat distribution are non existent. Some sex differences are evident with the peripheral-to-central ratios after age 14 years. ^