896 resultados para Tooth artificial


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the dimensions of gingival papillae in anterosuperior areas presenting at natural teeth (teeth sites) or single-tooth implants adjacent to natural teeth (implant-tooth sites) by analyzing determined distances. A total of 45 teeth and 46 implant-tooth sites were carefully selected. Clinical evaluation consisted of visual and quantitative analyses with millimeter grids on radiographs. Implant-tooth sites showed a smaller gingival papilla dimension than tooth sites (P < .01). Both evaluated distances (contact point to bone crest and between the roots of adjacent teeth or implant platform to root of adjacent tooth) in all groups significantly influenced the presence/absence of gingival papillae (P < .01). (Int J Periodontics Restorative Dent 2012;32:93-100.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteodistraction is a clinical reality available for the resolution of bone deficiencies before dental implant placement or in cases where the existing implants are at the wrong position. The objective of this study is to suggest a new possibility for bone distraction, based on tooth-implant bone distractors, in areas were there is the need for extensive alveolar bone recovery, with installed dental implants. This technique presented good results associated with its simplicity and low cost, making it a viable clinical solution for bone tissue augmentation. Although its use is recent, the suggested technique shows the potential to become used widely in attempts to achieve bone-height augmentation, primarily when dental implants are installed and osteointegrated already. (C) 2008 American Association of Oral and Maxillofacial Surgeons

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the success rate of maxillary immediate nonfunctional single-tooth loaded implants used into fresh extraction sites (immediate placement condition) or healed ridge (delayed placement condition).Materials and Methods: Eighty-two dental implants were placed in the maxilla of 64 consecutive patients from Private practice office and from a specialization course in Implantology. Forty-six implants were inserted under immediate placement condition, and 36 were inserted under delayed placement condition. The criteria used to evaluate success rate were those previously described by Albrektsson and Zarb (Int J Prosthodont 1993;6: 95-105), and follow-up period ranged from 18.0 to 39.7 months.Results: Seventy-nine implants fulfilled the success rate criteria (96.3%). Moreover, differences concerning implantation condition were not significant (P = 0.33, Qui-square test): three of the failed implants were from immediate placement group (success rate of 93.5%), and none was from delayed placement group (success rate of 100.0%).Conclusion: In the present sample, no statistically significant differences were detected for immediate nonfunctional single-tooth loaded implants under immediate placement condition in comparison with those inserted under delayed placement condition; both protocols had high success rate in maxillary incisors, canines, and premolars areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. To select the width of denture teeth, the distance between the marks indicating the location of the canines is usually measured around the curvature of the wax occlusal rim; however, most manufacturers' mold charts provide the measurements of the artificial 6 anterior teeth as if they were on a straight line.Purpose. The purpose of this study was to investigate whether the curve distance between the distal surfaces of the maxillary canines can be related to the combined width (straight measurement) of the 6 anterior teeth in 4 ethnic groups.Material and methods. Maxillary stone casts were obtained for 160 dentate subjects of 4 ethnic groups (40 whites, 40 blacks, 40 multiracial - descendants of white and black parents, and 40 Asians). The width of each maxillary anterior tooth was measured on the casts with sliding calipers. The combined width of the 6 anterior teeth (CW) corresponded to the sum of the width of each anterior tooth. The curve distance between the distal surfaces of the canines (CD) was measured by using dental tape and sliding calipers. The Pearson correlation coefficient and regression analysis were used to evaluate the relationship between CD and CW in each ethnic group (alpha=.05).Results. The mean CD and CW values (in mm) obtained were: whites (CD=52.12; CW=45.65); blacks (CD=56.10; CW=48.13); multiracial (CD=53.58; CW=46.54); and Asians (CD=53.29; CW=46.60). Significant (P<.001) correlations between CD and CW measurements were observed for all ethnic groups studied (whites, r=0.957; blacks, r=0.803; multiracial, r=0.917; and Asians, r=0.881). The following linear regression equations were obtained: whites [CD=1.1(CW)+0.3]; blacks [CD=0.95(CW)+9.3]; multiracial [CD=1.2(CW)-1.1]; and Asians [CD=1.0(CW)+5].Conclusions. The curve distance between the distal surfaces of the maxillary canines can be accurately related to the combined width of the 6 anterior teeth in the selection of denture teeth for the studied ethnic groups. (J Prosthet Dent 2012;107:400-404)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling.Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05).Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps.Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the assumption that there are morphological differences between the natural anterior dentition of men and women. The goal of the study was to determine the gender of patients based on the appearance of the anterior teeth in photographs. Materials and Methods: Laymen and observers from different specialties were asked to determine the gender of individuals based on the shape and arrangement of anterior teeth. Forty anterior dentition photographs of dental students of both genders (20 women, 20 men) between 18 and 26 years old were selected, coded, and randomly arranged in an album. The albums were delivered to five groups of observers: general practitioners (recently graduated dentists), prosthodontists, orthodontists, restorative dentists (specialists in cosmetic and restorative dentistry), and laymen (control group). The observers evaluated the photographs twice at 1-week intervals. Results: The average correctly identified values in women and men were 57.6% and 58.8%, respectively. There was no statistical difference between observers and between each group of professionals and the laymen group (p > 0.05). An intraobserver agreement was not observed between the evaluations (kappa =-0.01). Conclusion: The results of this limited study indicated that it was not possible to differentiate gender by viewing photographs of anterior teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To report the outcome of the endodontic treatment of a reimplanted central maxillary incisor with open apex after 8 years and 7 months of follow-up.This case report presents the treatment of a right central maxillary incisor of an 8-year old white male patient with history of traumatic avulsion and immediate replantation. The endodontic therapy consisted of periodical changes of calcium hydroxide dressing and a definitive root canal filling with mineral trioxide aggregate (MTA). The treatment was successful without pathologies up to 7 years of follow-up. After the institution of orthodontic treatment a localized and late root resorption was noticed at the last radiographic examination (8 years and 7 months postoperative follow-up). Moreover, the use of MTA promoted a mild crown grey discoloration.