952 resultados para Three models
Resumo:
A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.
Resumo:
Searches are reported for Higgs bosons in the context of either the standard model extended to include a fourth generation of fermions (SM4) with masses of up to 600 GeV or fermiophobic models. For the former, results from three decay modes (ττ, WW, and ZZ) are combined, whilst for the latter the diphoton decay is exploited. The analysed proton-proton collision data correspond to integrated luminosities of up to 5.1 fb-1 at 7 TeV and up to 5.3 fb-1 at 8 TeV. The observed results exclude the SM4 Higgs boson in the mass range 110-600 GeV at 99% confidence level (CL), and in the mass range 110-560 GeV at 99.9% CL. A fermiophobic Higgs boson is excluded in the mass range 110-147 GeV at 95% CL, and in the range 110-133 GeV at 99% CL. The recently observed boson with a mass near 125 GeV is not consistent with either an SM4 or a fermiophobic Higgs boson. © 2013 CERN.
Resumo:
The project comprises three phases of which Phase I would be implemented over the period September to December 2008. The major objectives of Phase I are, firstly, to establish the scope and feasibility of carrying out a study on the costs/benefits of taking action on climate change adaptation and cost effectiveness of mitigation in the Caribbean compared to a “business as usual” scenario, and secondly, to support initial actions to alert policymakers and key influencing constituencies to the urgency of this challenge.
Resumo:
The aim of this study was to evaluate stress distribution on the pen-implant bone, simulating the influence of Nobel Select implants with straight or angulated abutments on regular and switching platform in the anterior maxilla, by means of 3-dimensional finite element analysis. Four mathematical models of a central incisor supported by external hexagon implant (13 mm x 5 mm) were created varying the platform (R, regular or S. switching) and the abutments (S, straight or A, angulated 15 degrees). The models were created by using Mimics 13 and Solid Works 2010 software programs. The numerical analysis was performed using ANSYS Workbench 10.0. Oblique forces (100 N) were applied to the palatine surface of the central incisor. The bone/implant interface was considered perfectly integrated. Maximum (sigma(max)) and minimum (sigma(min)) principal stress values were obtained. For the cortical bone the highest stress values (sigma(max)) were observed in the RA (regular platform and angulated abutment, 51 MPa), followed by SA (platform switching and angulated abutment, 44.8 MPa), RS (regular platform and straight abutment, 38.6 MPa) and SS (platform switching and straight abutment, 36.5 MPa). For the trabecular bone, the highest stress values (sigma(max)) were observed in the RA (6.55 MPa), followed by RS (5.88 MPa), SA (5.60 MPa), and SS (4.82 MPa). The regular platform generated higher stress in the cervical periimplant region on the cortical and trabecular bone than the platform switching, irrespective of the abutment used (straight or angulated).
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: The purpose of this study is to analyze the tension distribution on bone tissue around implants with different angulations (0 degrees, 17 degrees, and 30 degrees) and connections (external hexagon and tapered) through the use of three-dimensional finite element and statistical analyses.Methods: Twelve different configurations of three-dimensional finite element models, including three inclinations of the implants (0 degrees, 17 degrees, and 30 degrees), two connections (an external hexagon and a tapered), and two load applications (axial and oblique), were simulated. The maximum principal stress values for cortical bone were measured at the mesial, distal, buccal, and lingual regions around the implant for each analyzed situation, totaling 48 groups. Loads of 200 and 100 N were applied at the occlusal surface in the axial and oblique directions, respectively. Maximum principal stress values were measured at the bone crest and statistically analyzed using analysis of variance. Stress patterns in the bone tissue around the implant were analyzed qualitatively.Results: The results demonstrated that under the oblique loading process, the external hexagon connection showed significantly higher stress concentrations in the bone tissue (P < 0.05) compared with the tapered connection. Moreover, the buccal and mesial regions of the cortical bone concentrated significantly higher stress (P < 0.005) to the external hexagon implant type. Under the oblique loading direction, the increased external hexagon implant angulation induced a significantly higher stress concentration (P = 0.045).Conclusions: The study results show that: 1) the oblique load was more damaging to bone tissue, mainly when associated with external hexagon implants; and 2) there was a higher stress concentration on the buccal region in comparison to all other regions under oblique load.
Resumo:
Background: The aim of this study is to characterize and evaluate the host response caused by three different models of experimental periodontitis in mice.Methods: C57BL/6 wild-type female mice were distributed into six experimental groups and sacrificed at 7, 15, and 30 days after the induction of periodontal disease: 1) group C: no treatment control group; 2) group L: periodontal disease induced by ligature; 3) group G-Pg: oral gavage with Porphyromonas gingivalis (Pg); 4) group G-PgFn: oral gavage with Fusobacterium nucleatum + Pg; 5) group I-Pg: heat-killed Pg injected into the palatal mucosa between the molars; and 6) group I-V: phosphatebuffered saline injected into the palatal mucosa. The samples were used to analyze the immune-inflammatory process in the gingival tissue via descriptive histologic and real-time polymerase chain reaction analyses. The alveolar bone loss was evaluated using microcomputed tomography. The data were analyzed using the Kruskal-Wallis test, followed by a post hoc Dunn test and analysis of variance, followed by a Tukey test using a 5% significance level.Results: Only the ligature model displayed significant alveolar bone loss in the initial period (7 days), which was maintained with time. The group injected with heat-killed Pg displayed significant alveolar bone loss starting from day 15, which continued to progress with time (P < 0.05). A significant increase (P < 0.05) in the gene expression of proinflammatory cytokines (interleukin-6 and -1b) and proteins involved in osteoclastogenesis (receptor activator of nuclear factor-kB ligand and osteoprotegerin) was observed in the ligature group on day 7.Conclusion: The ligature and injection of heat-killed Pg models were the most representative of periodontal disease in humans, whereas the oral gavage models were not effective at inducing the disease under the experimental conditions.
Resumo:
Adjusting autoregressive and mixed models to growth data fits discontinuous functions, which makes it difficult to determine critical points. In this study we propose a new approach to determine the critical stability point of cattle growth using a first-order autoregressive model and a mixed model with random asymptote, using the deterministic portion of the models. Three functions were compared: logistic, Gompertz, and Richards. The Richards autoregressive model yielded the best fit, but the critical growth values were adjusted very early, and for this purpose the Gompertz model was more appropriate.
Three-dimensional analysis of reinforced concrete members via embedded discontinuity finite elements
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents a modeling effort for developing safety performance models (SPM) for urban intersections for three major Brazilian cities. The proposed methodology for calibrating SPM has been divided into the following steps: defining the safety study objective, choosing predictive variables and sample size, data acquisition, defining model expression and model parameters and model evaluation. Among the predictive variables explored in the calibration phase were exposure variables (AADT), number of lanes, number of approaches and central median status. SPMs were obtained for three cities: Fortaleza, Belo Horizonte and Brasilia. The SPM developed for signalized intersections in Fortaleza and Belo Horizonte had the same structure and the most significant independent variables, which were AADT entering the intersection and number of lanes, and in addition, the coefficient of the best models were in the same range of values. For Brasilia, because of the sample size, the signalized and unsignalized intersections were grouped, and the AADT was split in minor and major approaches, which were the most significant variables. This paper also evaluated SPM transferability to other jurisdiction. The SPM for signalized intersections from Fortaleza and Belo Horizonte have been recalibrated (in terms of the COx) to the city of Porto Alegre. The models were adjusted following the Highway Safety Manual (HSM) calibration procedure and yielded C-x of 0.65 and 2.06 for Fortaleza and Belo Horizonte SPM respectively. This paper showed the experience and future challenges toward the initiatives on development of SPMs in Brazil, that can serve as a guide for other countries that are in the same stage in this subject. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Patterns of spatio-temporal distribution of Brachyura are determined by the interaction among life history traits, inter and intraspecific relationships, as well as by the variation of abiotic factors. This study aimed to characterize patterns of spatio-temporal distribution of Persephona lichtensteinii, Persephona mediterranea and Persephona punctata in two regions of the northern coast of Sao Paulo State, southeastern region of Brazil. Collections were done monthly from July 2001 to June 2003 in Caraguatatuba and Ubatuba, using a shrimp fishery boat equipped with double-rig nets. The patterns of species distribution were tested by means of redundancy analysis (RDA) and generalized linear mixed models (GLMM) in relation to the recorded environmental factors (BT: bottom temperature, BS: bottom salinity, OM: organic matter and granulometry (Phi)). The most influent environmental factor over the species distribution was the Phi, and the ascendant order of influence was P. lichtensteinii, P. punctata and P. mediterranea. The greater abundance of P. mediterranea showed a conservative pattern of distribution for the genus in the sampled region. The greater occurrence of P. punctata and P. lichtensteinii, in distinct transects than those occupied by P. mediterranea, seems to be a strategy to avoid competition among congeneric species, which is related to the substratum specificity.