840 resultados para Standardization Sample


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine sample sizes in studies on diagnostic accuracy and the proportion of studies that report calculations of sample size. DESIGN: Literature survey. DATA SOURCES: All issues of eight leading journals published in 2002. METHODS: Sample sizes, number of subgroup analyses, and how often studies reported calculations of sample size were extracted. RESULTS: 43 of 8999 articles were non-screening studies on diagnostic accuracy. The median sample size was 118 (interquartile range 71-350) and the median prevalence of the target condition was 43% (27-61%). The median number of patients with the target condition--needed to calculate a test's sensitivity--was 49 (28-91). The median number of patients without the target condition--needed to determine a test's specificity--was 76 (27-209). Two of the 43 studies (5%) reported a priori calculations of sample size. Twenty articles (47%) reported results for patient subgroups. The number of subgroups ranged from two to 19 (median four). No studies reported that sample size was calculated on the basis of preplanned analyses of subgroups. CONCLUSION: Few studies on diagnostic accuracy report considerations of sample size. The number of participants in most studies on diagnostic accuracy is probably too small to analyse variability of measures of accuracy across patient subgroups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power calculations in a small sample comparative study, with a continuous outcome measure, are typically undertaken using the asymptotic distribution of the test statistic. When the sample size is small, this asymptotic result can be a poor approximation. An alternative approach, using a rank based test statistic, is an exact power calculation. When the number of groups is greater than two, the number of calculations required to perform an exact power calculation is prohibitive. To reduce the computational burden, a Monte Carlo resampling procedure is used to approximate the exact power function of a k-sample rank test statistic under the family of Lehmann alternative hypotheses. The motivating example for this approach is the design of animal studies, where the number of animals per group is typically small.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Outcome-dependent, two-phase sampling designs can dramatically reduce the costs of observational studies by judicious selection of the most informative subjects for purposes of detailed covariate measurement. Here we derive asymptotic information bounds and the form of the efficient score and influence functions for the semiparametric regression models studied by Lawless, Kalbfleisch, and Wild (1999) under two-phase sampling designs. We show that the maximum likelihood estimators for both the parametric and nonparametric parts of the model are asymptotically normal and efficient. The efficient influence function for the parametric part aggress with the more general information bound calculations of Robins, Hsieh, and Newey (1995). By verifying the conditions of Murphy and Van der Vaart (2000) for a least favorable parametric submodel, we provide asymptotic justification for statistical inference based on profile likelihood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PRINCIPLES: The aim of this study was to determine the prevalence of hepatitis C (HCV) infection in a sample of pregnant women living in Switzerland in 1990-1991, in order to complement existing data in various populations. METHODS: Blood samples were collected from women from consecutive births in obstetric wards in public hospitals of 23 Swiss cantons over a one-year period. They were tested, among other things, for the presence of hepatitis C virus antibodies (anti-HCV). Statistical analyses were done to explore the association of demographic variables with anti-HCV. RESULTS: The study included a total of 9,057 women of whom 64 tested positive for anti-HCV, resulting in a crude prevalence of 0.71%. Prevalence varied by age and was highest in the 25-29-year age-group (0.90%). 43/5,685 Swiss women were HCV seropositive (0.76%) compared with 21/3,372 non-Swiss women (0.62%). Stratified analysis showed a significant association between anti-HCV and anti-HBc antibody positivity in Swiss (adjusted OR [aOR] 23, 95% CI 12-43) and non-Swiss nationals (aOR 3.3, 95% CI 1.3-8.3). CONCLUSIONS: The prevalence of anti-HCV antibodies in the early 1990s was <1% in this sample of pregnant women in Switzerland and was associated with age, nationality and the presence of anti-HBc antibodies, a marker of exposure to hepatitis B virus. These results are in accordance with those from other published European studies. If an effective intervention to prevent vertical transmission becomes available, information on the current prevalence of HCV in pregnant women would be needed in order to assess how screening recommendations should be modified.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Although critically ill patients usually have various central intravenous (i.v.) lines, numerous drugs have to be infused simultaneously through the same lines. This can result in potentially harmful in-line incompatibility that can cause decreased drug effectiveness or increased microparticle load. To minimize the risk of these medication errors at an anesthesia intensive care unit (ICU), the preparation and administration of continuously infused drugs were standardized and the practicability in daily clinical routine was evaluated. SUMMARY: The concentration and diluent of continuously administered i.v. drugs were standardized. The drugs were grouped according to pH, medical indication, and chemical structure. The ICU staff decided to use multilumen central venous catheters, and each group of drugs was assigned to one lumen. Only drugs that belonged to the same group were infused simultaneously through the same lumen; therefore, intragroup incompatibilities had to be excluded before establishing the new drug administration plan at the ICU. The visual compatibility of 115 clinically reasonable intragroup drug mixtures was investigated. All drug combinations were compatible for six hours except mixtures containing thiopental, which was reassigned to a single-line use. In the following year, the practicability of this drug administration plan was evaluated. No deviations were found in the compliance of the staff prescribing and preparing only standardized concentrations and diluents. Further research to investigate the chemical compatibility of the drugs in these multiple mixtures will follow. CONCLUSION: A project intended to avoid incompatibility among i.v. drugs infused in the intensive care setting included steps to standardize solutions and determine which could be given together.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reproducible, standardized and simple sample preparation methodology is the key to successful two-dimensional gel electrophoresis (2-DE). This chapter describes step-by-step the sample preparation of culture medium from Madin-Darby canine kidney (MDCK) cells. Tips and tricks are given to circumvent possible pitfalls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary zone electrophoresis (CZE) in fused-silica capillaries is an effective analytical approach for the separation and determination of the transferrin (Tf) isoforms and thus carbohydrate-deficient transferrin (CDT) in human serum. Sera of patients with progressed liver cirrhosis are prone to interferences in the beta region which prevent the proper determination of CDT by CZE without additional sample preparation. Efforts to identify, reduce or even eliminate these interferences have been undertaken. Data obtained by ultrafiltration, affinity subtraction procedures using protein A, protein L and antibodies against immunoglobulins or Tf, and immunopurification of Tf suggest that the interferences in the patient sera are caused by increased levels of IgA and IgM and are best eliminated by immunopurification. Avian IgY antibody spin column immunocapture of serum Tf followed by CZE analysis of the stripped and concentrated fraction is shown to provide an attractive approach for CDT monitoring in sera with beta region interferences.