955 resultados para Six van Vromade, P. H.
Resumo:
info:eu-repo/semantics/published
Resumo:
P-glycoprotein (Pgp) antagonists have had unpredictable pharmacokinetic interactions requiring reductions of chemotherapy. We report a phase I study using tariquidar (XR9576), a potent Pgp antagonist, in combination with vinorelbine. EXPERIMENTAL DESIGN: Patients first received tariquidar alone to assess effects on the accumulation of (99m)Tc-sestamibi in tumor and normal organs and rhodamine efflux from CD56+ mononuclear cells. In the first cycle, vinorelbine pharmacokinetics was monitored after the day 1 and 8 doses without or with tariquidar. In subsequent cycles, vinorelbine was administered with tariquidar. Tariquidar pharmacokinetics was studied alone and with vinorelbine. RESULTS: Twenty-six patients were enrolled. Vinorelbine 20 mg/m(2) on day 1 and 8 was identified as the maximum tolerated dose (neutropenia). Nonhematologic grade 3/4 toxicities in 77 cycles included the following: abdominal pain (4 cycles), anorexia (2), constipation (2), fatigue (3), myalgia (2), pain (4) and dehydration, depression, diarrhea, ileus, nausea, and vomiting, (all once). A 150-mg dose of tariquidar: (1) reduced liver (99m)Tc-sestamibi clearance consistent with inhibition of liver Pgp; (2) increased (99m)Tc-sestamibi retention in a majority of tumor masses visible by (99m)Tc-sestamibi; and (3) blocked Pgp-mediated rhodamine efflux from CD56+ cells over the 48 hours examined. Tariquidar had no effects on vinorelbine pharmacokinetics. Vinorelbine had no effect on tariquidar pharmacokinetics. One patient with breast cancer had a minor response, and one with renal carcinoma had a partial remission. CONCLUSIONS: Tariquidar is a potent Pgp antagonist, without significant side effects and much less pharmacokinetic interaction than previous Pgp antagonists. Tariquidar offers the potential to increase drug exposure in drug-resistant cancers.
Resumo:
Comprend : Hommage au R.P. Louis Gravoueille ; Henri de Guise
Resumo:
Este estudio de caso se centra en los esfuerzos de China por reanudar los Six Party Talks o Diálogos a Seis Bandas que son considerados como la opción más viable para tratar la situación nuclear en la península coreana.
Resumo:
A measurement of the top quark pair production cross section in proton antiproton collisions at an interaction energy of root s=1.96 TeV is presented. This analysis uses 405 +/- 25 pb(-1) of data collected with the D0 detector at the Fermilab Tevatron Collider. Fully hadronic t (t) over bar decays with final states of six or more jets are separated from the multijet background using secondary vertex tagging and a neural network. The t (t) over bar cross section is measured as sigma(t (t) over bar)=4.5(-1.9)(+2.0)(stat)(-1.1)(+1.4)(syst)+/- 0.3(lumi) pb for a top quark mass of m(t)=175 GeV/c(2).
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Abstract Background Considering the increasing use of polymyxins to treat infections due to multidrug resistant Gram-negative in many countries, it is important to evaluate different susceptibility testing methods to this class of antibiotic. Methods Susceptibility of 109 carbapenem-resistant P. aeruginosa to polymyxins was tested comparing broth microdilution (reference method), disc diffusion, and Etest using the new interpretative breakpoints of Clinical and Laboratory Standards Institute. Results Twenty-nine percent of isolates belonged to endemic clone and thus, these strains were excluded of analysis. Among 78 strains evaluated, only one isolate was resistant to polymyxin B by the reference method (MIC: 8.0 μg/mL). Very major and major error rates of 1.2% and 11.5% were detected comparing polymyxin B disc diffusion with the broth microdilution (reference method). Agreement within 1 twofold dilution between Etest and the broth microdilution were 33% for polymyxin B and 79.5% for colistin. One major error and 48.7% minor errors were found comparing polymyxin B Etest with broth microdilution and only 6.4% minor errors with colistin. The concordance between Etest and the broth microdilution (reference method) was respectively 100% for colistin and 90% for polymyxin B. Conclusion Resistance to polymyxins seems to be rare among hospital carbapenem-resistant P. aeruginosa isolates over a six-year period. Our results showed, using the new CLSI criteria, that the disc diffusion susceptibility does not report major errors (false-resistant results) for colistin. On the other hand, showed a high frequency of minor errors and 1 very major error for polymyxin B. Etest presented better results for colistin than polymyxin B. Until these results are reproduced with a large number of polymyxins-resistant P. aeruginosa isolates, susceptibility to polymyxins should be confirmed by a reference method.
Resumo:
AIMS To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.