906 resultados para Satellite solar power stations.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements of solar radiation over and under sea ice have been performed on various stations in the Arctic Ocean during the Polarstern cruise PS92 (TRANSSIZ) between 19 May and 30 June 2015. All radiation measurements have been performed with Ramses spectral radiometers (Trios, Rastede, Germany). All data are given in full spectral resolution interpolated to 1.0 nm, and integrated over the entire wavelength range (broadband, total: 320 to 950 nm). Two sensors were mounted on a Remotely Operated Vehicle (ROV) and one radiometer was installed on the sea ice for surface reference measurements (solar irradiance). On the ROV, one irradiance sensor (cos-collector) for energy budget calculations and one radiance sensor (9° opening angle) to obtain high resolution spatial variability were installed. Along with the radiation measurements, ROV positions were obtained from acoustic USBL-positioning and all parameters of vehicle depth, distance to the ice and attitude recorded. All times are given in UTC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Baseline Surface Radiation Network (BSRN) and its central archive - the World Radiation Monitoring Center (WRMC) - was created in 1992. It is a project of the Data Assimilation Panel from the Global Energy and Water Cycle Experiment (GEWEX) under the umbrella of the World Climate Research Programme (WCRP) and as such is aimed at detecting important changes in the Earth's radiation field at the Earth's surface which may be related to climate changes. The data are of primary importance in supporting the validation and confirmation of satellite and computer model estimates of these quantities. At a small number of stations in contrasting climatic zones, covering a latitude range from 80°N to 90°S, solar and atmospheric radiation is measured with instruments of the highest available accuracy and with high time resolution (1 to 3 minutes). Since 2008 the WRMC is hosted by the Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research (AWI), Bremerhaven, Germany (http://www.bsrn.awi.de/).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite continuous efforts to improve the coverage, the access to electricity remains insufficient in many developing countries, particularly in geographically challenged locations, due mostly to the high cost of grid extension. To rigorously investigate the effectiveness of solar products as an alternative in remote areas, we conducted a randomized controlled trial in river islands of northern Bangladesh where no grid-based electricity is available. We found that solar lanterns significantly increased home study hours among schooled children, especially in the night and before exams. School attendance rate also initially increases due to the provision of solar lamps, although such effects fade away over time. The increased study time and initial school attendance rate, however, did not improve children's exam results. We also found marginal improvements on health-related indicators, such as eye redness and irritation, but negligible impacts on respiratory indicators. Households that received solar lanterns substituted the traditional lighting sources with modern technology, leading to a significant decrease in annual biomass fuel consumptions, particularly kerosene. Finally, treated households showed a greater self-reported willingness to purchase solar products compared with the control group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we study the optimization of laser-fired contact (LFC) processing parameters, namely laser power and number of pulses, based on the electrical resistance measurement of an aluminum single LFC point. LFC process has been made through four passivation layers that are typically used in c-Si and mc-Si solar cell fabrication: thermally grown silicon oxide (SiO2), deposited phosphorus-doped amorphous silicon carbide (a-SiCx/H(n)), aluminum oxide (Al2O3) and silicon nitride (SiNx/H) films. Values for the LFC resistance normalized by the laser spot area in the range of 0.65–3 mΩ cm2 have been obtained

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article analyses the long-term performance of collective off-grid photovoltaic (PV) systems in rural areas. The use of collective PV systems for the electrification of small medium-size villages in developing countries has increased in the recent years. They are basically set up as stand-alone installations (diesel hybrid or pure PV) with no connection with other electrical grids. Their particular conditions (isolated) and usual installation places (far from commercial/industrial centers) require an autonomous and reliable technology. Different but related factors affect their performance and the energy supply; some of them are strictly technical but others depend on external issues like the solar energy resource and users’ energy and power consumption. The work presented is based on field operation of twelve collective PV installations supplying the electricity to off-grid villages located in the province of Jujuy, Argentina. Five of them have PV generators as unique power source while other seven include the support of diesel groups. Load demand evolution, energy productivity and fuel consumption are analyzed. Besides, energy generation strategies (PV/diesel) are also discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The power generated by large grid-connected photovoltaic (PV) plants depends greatly on the solar irradiance. This paper studies the effects of the solar irradiance variability analyzing experimental 1-s data collected throughout a year at six PV plants, totaling 18 MWp. Each PV plant was modeled as a first order filter function based on an analysis in the frequency domain of the irradiance data and the output power signals. An empiric expression which relates the filter parameters and the PV plant size has been proposed. This simple model has been successfully validated precisely determining the daily maximum output power fluctuation from incident irradiance measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Concentrator photovoltaic is an emergent technology that may be a good economical and efficient alternative for the generation of electricity at a competitive cost. However, the reliability of these new solar cells and systems is still an open issue due to the high-irradiation level they are subjected to as well as the electrical and thermal stresses that they are expected to endure. To evaluate the reliability in a short period of time, accelerated aging tests are essential. Thermal aging tests for concentrator photovoltaic solar cells and systems under illumination are not available because no technical solution to the problem of reaching the working concentration inside a climatic chamber has been available. This work presents an automatic instrumentation system that overcomes the aforementioned limitation. Working conditions have been simulated by forward biasing the solar cells to the current they would handle at the working concentration (in this case, 700 and 1050 times the irradiance at one standard sun). The instrumentation system has been deployed for more than 10 000 h in a thermal aging test for III-V concentrator solar cells, in which the generated power evolution at different temperatures has been monitored. As a result of this test, the acceleration factor has been calculated, thus allowing for the degradation evolution at any temperature in addition to normal working conditions to be obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Models based on degradation are powerful and useful tools to evaluate the reliability of those devices in which failure happens because of degradation in the performance parameters. This paper presents a procedure for assessing the reliability of concentrator photovoltaic (CPV) modules operating outdoors in real-time conditions. With this model, the main reliability functions are predicted. This model has been applied to a real case with a module composed of GaAs single-junction solar cells and total internal reflection (TIR) optics

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El objetivo de este trabajo es el análisis comparativo de dos fuentes de irradiación solar para el territorio peninsular español, siguiendo la iniciativa de estudios previos para otras regiones. La primera de estas fuentes corresponde a medidas de irradiación global diaria en el plano horizontal realizadas por los piranómetros de la red de estaciones meteorológicas del Sistema de Información Agroclimática del Regadío (SIAR), perteneciente al Ministerio de Medio Ambiente, Rural y Marino. Esta red está compuesta por más de 360 estaciones ubicadas en once Comunidades Autónomas de la España peninsular. La otra fuente de comparación es un conjunto de imágenes de satélite proporcionadas por la iniciativa denominada ``The Satellite Application Facility on Climate Monitoring'' (CM-SAF).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sunrise is a solar telescope, successfully flown in June 2009 with a long duration balloon from the Swedish Space Corporation Esrange launch site. The design of the thermal control of SUNRISE was quite critical because of the sensitivity to temperature of the optomechanical devices and the electronics. These problems got more complicated due the size and high power dissipation of the system. A detailed thermal mathematical model of SUNRISE was set up to predict temperatures. In this communication the thermal behaviour of SUNRISE during flight is presented. Flight temperatures of some devices are presented and analysed. The measured data have been compared with the predictions given by the thermal mathematical models. The main discrepancies between flight data and the temperatures predicted by the models have been identified. This allows thermal engineers to improve the knowledge of the thermal behaviour of the system for future missions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of photovoltaic experimental plants in engineering educational buildings contributes to an increase in acceptance of this technology by future engineers. There are some photovoltaic (PV) systems in educational buildings in Spain, but they are usually limited to buildings in relation to electrical technologies or research areas. They are not common in other educational or official buildings. This paper presents the project of a grid-connected solar plant with two main objectives. First, different PV module technologies will be compared. Second, an emphasis on agronomical areas in educational settings will be reviewed in an attempt to facilitate student engagement in the use of the power plant. The system is grid-connected in order to pay-back the investment in the plant. In fact the electricity generated by the plant will be used by the installations of the building, as it is the closest consumer. This work intends to approximate photovoltaic technology to university degrees not directly related with it and at the same time research in comparison of systems with different technologies. This is a good example of an solar plant for both optimum production and educational purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An asymmetric stripline is proposed in this paper. The main aim of this line is to distribute the power among subarrays in an array with minimum losses. Several vertical transitions to subarrays are shown besides some network designs at X band for a square array for satellite communications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to complement ISFOC’s characterization capabilities, a Helios 3198 CPV Solar Simulator was installed in summer 2010. This Solar Simulator, based on a parabolic mirror and a high-intensity, small area Xenon flash lamp was developed by the Instituto de Energía Solar in Madrid [1] and is manufactured and distributed by Soldaduras Avanzadas [2]. This simulator is used not only for R&D purposes, but as a quality control tool for incoming modules that are to be installed in ISFOC’s CPV plants. In this paper we will discuss the results of recent measurements of close to 5000 modules, the entire production of modules corresponding to a small CPV power plant (200 kWp). We scrutinize the resultant data for signs of drift in the measurements, and analyze the light quality before and after, to check for changes in spectrum or spatial uniformity.)