950 resultados para Radiotherapy Setup Errors
Resumo:
Height of instrument (HI) blunders in GPS measurements cause position errors. These errors can be pure vertical, pure horizontal, or a mixture of both. There are different error regimes depending on whether both the base and the rover both have HI blunders, if just the base has an HI blunder, or just the rover has an HI blunder. The resulting errors are on the order of 30 cm for receiver separations of 1000 km for an HI blunder of 2 m. Given the complicated nature of the errors, we believe it would be difficult, if not impossible, to detect such errors by visual inspection. This serves to underline the necessity to enter GPS HIs correctly.
Resumo:
The purpose of this work was to develop a comprehensive IMSRT QA procedure that examined, using EPID dosimetry and Monte Carlo (MC) calculations, each step in the treatment planning and delivery process. These steps included verification of the field shaping, treatment planning system (RTPS) dose calculations, and patient dose delivery. Verification of each step in the treatment process is assumed to result in correct dose delivery to the patient. ^ The accelerator MC model was verified against commissioning data for field sizes from 0.8 × 0.8 cm 2 to 10 × 10 cm 2. Depth doses were within 2% local percent difference (LPD) in low gradient regions and 1 mm distance to agreement (DTA) in high gradient regions. Lateral profiles were within 2% LPD in low gradient regions and 1 mm DTA in high gradient regions. Calculated output factors were within 1% of measurement for field sizes ≥1 × 1 cm2. ^ The measured and calculated pretreatment EPID dose patterns were compared using criteria of 5% LPD, 1 mm DTA, or 2% of central axis pixel value with ≥95% of compared points required to pass for successful verification. Pretreatment field verification resulted in 97% percent of the points passing. ^ The RTPS and Monte Carlo phantom dose calculations were compared using 5% LPD, 2 mm DTA, or 2% of the maximum dose with ≥95% of compared points required passing for successful verification. RTPS calculation verification resulted in 97% percent of the points passing. ^ The measured and calculated EPID exit dose patterns were compared using criteria of 5% LPD, 1 mm DTA, or 2% of central axis pixel value with ≥95% of compared points required to pass for successful verification. Exit dose verification resulted in 97% percent of the points passing. ^ Each of the processes above verified an individual step in the treatment planning and delivery process. The combination of these verification steps ensures accurate treatment delivery to the patient. This work shows that Monte Carlo calculations and EPID dosimetry can be used to quantitatively verify IMSRT treatments resulting in improved patient care and, potentially, improved clinical outcome. ^
Resumo:
Because the goal of radiation therapy is to deliver a lethal dose to the tumor, accurate information on the location of the tumor needs to be known. Margins are placed around the tumor to account for variations in the daily position of the tumor. If tumor motion and patient setup uncertainties can be reduced, margins that account for such uncertainties in tumor location in can be reduced allowing dose escalation, which in turn could potentially improve survival rates. ^ In the first part of this study, we monitor the location of fiducials implanted in the periphery of lung tumors to determine the extent of non-gated and gated fiducial motion, and to quantify patient setup uncertainties. In the second part we determine where the tumor is when different methods of image-guided patient setup and respiratory gating are employed. In the final part we develop, validate, and implement a technique in which patient setup uncertainties are reduced by aligning patients based upon fiducial locations in projection images. ^ Results from the first part indicate that respiratory gating reduces fiducial motion relative to motion during normal respiration and setup uncertainties when the patients were aligned each day using externally placed skin marks are large. The results from the second part indicate that current margins that account for setup uncertainty and tumor motion result in less than 2% of the tumor outside of the planning target volume (PTV) when the patient is aligned using skin marks. In addition, we found that if respiratory gating is going to be used, it is most effective if used in conjunction with image-guided patient setup. From the third part, we successfully developed, validated, and implemented on a patient a technique for aligning a moving target prior to treatment to reduce the uncertainties in tumor location. ^ In conclusion, setup uncertainties and tumor motion are a significant problem when treating tumors located within the thoracic region. Image-guided patient setup in conjunction with treatment delivery using respiratory gating reduces these uncertainties in tumor locations. In doing so, margins around the tumor used to generate the PTV can be reduced, which may allow for dose escalation to the tumor. ^
Resumo:
Medication errors, one of the most frequent types of medical errors, are a common cause of patient harm in hospital systems today. Nurses at the bedside are in a position to encounter many of these errors since they are there at the start of the process (ordering/prescribing) and the end of the process (administration). One of the recommendations from the IOM (Institute of Medicine) report, "To Err is Human," was for organizations to identify and learn from medical errors through event reporting systems. While many organizations have reporting systems in place, research studies report a significant amount of underreporting by nurses. A systematic review of the literature was performed to identify contributing factors related to the reporting and not reporting of medication errors by nurses at the bedside.^ Articles included in the literature review were primary or secondary studies, dated January 1, 2000 – July 2009, related to nursing medication error reporting. All 634 articles were reviewed with an algorithm developed to standardize the review process and help filter out those that did not meet the study criteria. In addition, 142 article bibliographies were reviewed to find additional studies that were not found in the original literature search.^ After reviewing the 634 articles and the additional 108 articles discovered in the bibliography review, 41 articles met the study criteria and were used in the systematic literature review results.^ Fear of punitive reactions to medication errors was a frequent barrier to error reporting. Nurses fear reactions from their leadership, peers, patients and their families, nursing boards, and the media. Anonymous reporting systems and departments/organizations with a strong safety culture in place helped to encourage the reporting of medication errors by nursing staff.^ Many of the studies included in this literature review do not allow results that can be generalized. The majority of them took place in single institutions/organizations with limited sample sizes. Stronger studies with larger sample sizes need to be performed, utilizing data collection methods that have been validated, to determine stronger correlations between safety cultures and nurse error reporting.^
Resumo:
A large number of ridge regression estimators have been proposed and used with little knowledge of their true distributions. Because of this lack of knowledge, these estimators cannot be used to test hypotheses or to form confidence intervals.^ This paper presents a basic technique for deriving the exact distribution functions for a class of generalized ridge estimators. The technique is applied to five prominent generalized ridge estimators. Graphs of the resulting distribution functions are presented. The actual behavior of these estimators is found to be considerably different than the behavior which is generally assumed for ridge estimators.^ This paper also uses the derived distributions to examine the mean squared error properties of the estimators. A technique for developing confidence intervals based on the generalized ridge estimators is also presented. ^
Resumo:
Errors in the administration of medication represent a significant loss of medical resources and pose life altering or life threatening risks to patients. This paper considered the question, what impact do Computerized Physician Order Entry (CPOE) systems have on medication errors in the hospital inpatient environment? Previous reviews have examined evidence of the impact of CPOE on medication errors, but have come to ambiguous conclusions as to the impact of CPOE and decision support systems (DSS). Forty-three papers were identified. Thirty-one demonstrated a significant reduction in prescribing error rates for all or some drug types; decreases in minor errors were most often reported. Several studies reported increases in the rate of duplicate orders and failures to remove contraindicated drugs, often attributed to inappropriate design or to an inability to operate the system properly. The evidence on the effectiveness of CPOE to reduce errors in medication administration is compelling though it is limited by modest study sample sizes and designs. ^
Resumo:
This report describes the development of a Markov model for comparing percutaneous radiofrequency ablation (RFA) and stereotactic body radiation therapy (SBRT) in terms of their cost-utility in treating isolated liver metastases from colorectal cancer. The model is based on data from multiple retrospective and prospective studies, available data on different utility states associated with treatment and complications, as well as publicly available Medicare costs. The purpose of this report is to establish a well-justified model for clinical management decisions. In comparison with SBRT, RFA is the most cost-effective treatment for this patient population. From the societal perspective, SBRT may be an acceptable alternative with an ICER of $28,673/QALY. ^
Resumo:
Next-generation sequencing (NGS) technology has become a prominent tool in biological and biomedical research. However, NGS data analysis, such as de novo assembly, mapping and variants detection is far from maturity, and the high sequencing error-rate is one of the major problems. . To minimize the impact of sequencing errors, we developed a highly robust and efficient method, MTM, to correct the errors in NGS reads. We demonstrated the effectiveness of MTM on both single-cell data with highly non-uniform coverage and normal data with uniformly high coverage, reflecting that MTM’s performance does not rely on the coverage of the sequencing reads. MTM was also compared with Hammer and Quake, the best methods for correcting non-uniform and uniform data respectively. For non-uniform data, MTM outperformed both Hammer and Quake. For uniform data, MTM showed better performance than Quake and comparable results to Hammer. By making better error correction with MTM, the quality of downstream analysis, such as mapping and SNP detection, was improved. SNP calling is a major application of NGS technologies. However, the existence of sequencing errors complicates this process, especially for the low coverage (
Resumo:
Over the last decade, adverse events and medical errors have become a main focus of interest for the standards of quality and safety in the U.S. healthcare system (Weinstein & Henderson, 2009). Particularly when a medical error occurs, the disclosure of medical errors and its practices have become a focal point of the healthcare process. Patients and family members who have experienced a medical error might be able to provide knowledge and insight on how to improve the disclose process. However, patient and family member are not typically involved in the disclosure process, thus their experiences go unnoticed. ^ The purpose of this research was to explore how best to include patients and family members in the disclosure process regarding a medical error. The research consisted of 28 qualitative interviews from three stakeholder groups: Hospital Administrators, Clinical Service Providers, and Patients and Family Members. They were asked for their ideas and suggestions on how best to include patients and family members in the disclosure process. Framework Analysis was used to analyze this data and find prevalent themes based on the primary research question. A secondary aim was to index categories created based on the interviews that were collected. Data was used from the Texas Disclosure and Compensation Study with Dr. Eric Thomas as the Principal Investigator. Full acknowledgement of access to this data is given to Dr. Thomas. ^ The themes from the research revealed that each stakeholder group was interested and open to including patients and family members in the disclosure process and that the disclosure process should not be a "one-way" avenue. The themes gave many suggestions regarding how to best include patients and family members in the disclosure process of a medical error. Secondary aims revealed several ways to assess the ideas and suggestion given by the stakeholders. Overall, acceptability of getting the perspective of patients and family members was the most common theme. Comparison of each stakeholder group revealed that including patients and family members would be beneficial to improving hospital disclosure practices. ^ Conclusions included a list of recommendations and measureable appropriate strategies that could provide hospital with key stakeholders insights on how to improve their disclosure process. Sharing patients and family members experience with healthcare providers can encourage a shift in culture where patients are valued and active in participating in hospital practices. To my knowledge, this research is the very first of its kind and moves the disclosure process conversation forward in a patient-family member inclusion direction that will assist in improving disclosure practices. Future research should implement and evaluate the success of the various inclusion strategies.^
Resumo:
Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some patients with Hodgkin lymphoma, carbon-ion therapy would reduce the predicted risk of second cancer incidence in the breast compared with proton therapy. The purpose of this work was to determine whether 4D-optimized carbon-ion therapy would significantly reduce the predicted risk of radiation induced second cancers in the breast for female Hodgkin lymphoma patients while preserving tumor control compared with proton therapy. To achieve our goals, we first investigated whether 4D-optimized carbon beam tracking could reduce dose to volumes outside a moving target compared with 3D-optimized carbon beam tracking while preserving target dose coverage. To understand the reliability of scanned carbon beam tracking, we studied the robustness of dose distributions in thoracic targets to uncertainties in patient motion. Finally, we investigated whether using carbon-ion therapy instead of proton therapy would significantly reduce the predicted risk of second cancer in the breast for a sample of Hodgkin lymphoma patients. We found that 4D-optimized ion beam tracking therapy can reduce the maximum dose to critical structures near a moving target by as much as 53%, compared to 3D-optimized ion beam tracking therapy. We validated these findings experimentally using a scanned carbon ion synchrotron and a motion phantom. We found scanned carbon beam tracking to be sensitive to a number of motion uncertainties, most notably phase delays in tracking, systematic spatial errors, and interfractional motion changes. Our findings indicate that a lower risk of second cancer in the breast might be expected for some Hodgkin lymphoma patients using carbon-ion therapy instead of proton therapy. For our reference scenario, we found the ratio of risk to be 0.77 ± 0.35 for radiogenic breast cancer after carbon-ion therapy versus proton therapy. Our findings were dependent on the RBE values for tumor induction and the radiosensitivity of breast tissue, as well as the physical dose distribution.