995 resultados para Radiation Pattern


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study analyses the spatial pattern of quaternary gravitational slope deformations (GSD) and historical/present-day instabilities (HPI) inventoried in the Swiss Rhone Valley. The main objective is to test if these events are clustered (spatial attraction) or randomly distributed (spatial independency). Moreover, analogies with the cluster behaviour of earthquakes inventoried in the same area were examined. The Ripley's K-function was applied to measure and test for randomness. This indicator allows describing the spatial pattern of a point process at increasing distance values. To account for the non-constant intensity of the geological phenomena, a modification of the K-function for inhomogeneous point processes was adopted. The specific goal is to explore the spatial attraction (i.e. cluster behaviour) among landslide events and between gravitational slope deformations and earthquakes. To discover if the two classes of instabilities (GSD and HPI) are spatially independently distributed, the cross K-function was computed. The results show that all the geological events under study are spatially clustered at a well-defined distance range. GSD and HPI show a similar pattern distribution with clusters in the range 0.75?9 km. The cross K-function reveals an attraction between the two classes of instabilities in the range 0?4 km confirming that HPI are more prone to occur within large-scale slope deformations. The K-function computed for GSD and earthquakes indicates that both present a cluster tendency in the range 0?10 km, suggesting that earthquakes could represent a potential predisposing factor which could influence the GSD distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adherence to aMediterranean diet (MD) is associated with a reduced risk of coronary heart disease. However, themolecular mechanisms involved are not fully understood. The aim of this studywas to compare the effects of 2MD with those of a lowfat- diet (LFD) on circulating inflammatory biomarkers related to atherogenesis. A total of 516 participants included in the PreventionwithMediterraneanDiet Studywere randomized into 3 intervention groups [MD supplementedwith virgin olive oil (MD-VOO); MD supplemented with mixed nuts (MD-Nuts); and LFD]. At baseline and after 1 y, participants completed FFQ and adherence to MD questionnaires, and plasma concentrations of inflammatory markers including intercellular adhesion molecule-1(ICAM-1), IL-6, and 2 TNF receptors (TNFR60 and TNFR80) were measured by ELISA. At 1 y, the MD groups had lower plasma concentrations of IL-6, TNFR60, and TNFR80 (P , 0.05), whereas ICAM-1, TNFR60, and TNFR80 concentrations increased in the LFD group (P , 0.002). Due to between-group differences, participants in the 2 MD groups had lower plasma concentrations of ICAM-1, IL-6, TNFR60, and TNFR80 compared to those in the LFD group (P # 0.028). When participants were categorized in tertiles of 1-y changes in the consumption of selected foods, those in the highest tertile of virgin olive oil (VOO) and vegetable consumption had a lower plasma TNFR60 concentration compared with those in tertile 1 (P,0.02).Moreover, the only changes in consumption thatwere associated with 1-y changes in the geometricmean TNFR60 concentrations were those of VOO and vegetables (P = 0.01). This study suggests that a MD reduces TNFR concentrations in patients at high cardiovascular risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain damage caused by an acute injury depends on the initial severity of the injury and the time elapsed after the injury. To determine whether these two variables activate common mechanisms, we compared the response of the rat medial septum to insult with a graded series of concentrations of a-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid (AMPA) with the time-course effects of a low dose of AMPA. For this purpose we conducted a dose-response study at concentrations of AMPA between 0.27 and 10.8 nmol to measure atrophy of the septal area, losses of cholinergic and GABAergic neurons, astroglial and microglial reactions, and calcification. Cholinergic neurons, whose loss paralleled the degree of septal atrophy produced by AMPA, are more sensitive than GABAergic neurons to the injury produced by AMPA. At doses of AMPA above 2.7 nmol, calcification and the degree of microglial reaction increased only in the GABAergic region of the septal area, whereas atrophy and neuronal loss reached a plateau. We chose the 2.7-nmol dose of AMPA to determine how these parameters were modified between 4 days and 6 months after injection. We found that atrophy and neuronal loss increased progressively through the 6-month study period, whereas astrogliosis ceased to be observed after 1 month, and calcium precipitates were never detected. We conclude that septal damage does not increase with the intensity of an excitotoxic insult. Rather, it progresses continuously after the insult. Because these two situations involve different mechanisms, short-term paradigms are inappropriate for interpreting the pathogenic mechanisms responsible for long-term neurodegenerative processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fusion of bone marrow (BM) hematopoietic cells with hepatocytes to generate BM derived hepatocytes (BMDH) is a natural process, which is enhanced in damaged tissues. However, the reprogramming needed to generate BMDH and the identity of the resultant cells is essentially unknown. In a mouse model of chronic liver damage, here we identify a modification in the chromatin structure of the hematopoietic nucleus during BMDH formation, accompanied by the loss of the key hematopoietic transcription factor PU.1/Sfpi1 (SFFV proviral integration 1) and gain of the key hepatic transcriptional regulator HNF-1A homeobox A (HNF-1A/Hnf1a). Through genome-wide expression analysis of laser captured BMDH, a differential gene expression pattern was detected and the chromatin changes observed were confirmed at the level of chromatin regulator genes. Similarly, Tranforming Growth Factor-β1 (TGF-β1) and neurotransmitter (e.g. Prostaglandin E Receptor 4 [Ptger4]) pathway genes were over-expressed. In summary, in vivo BMDH generation is a process in which the hematopoietic cell nucleus changes its identity and acquires hepatic features. These BMDHs have their own cell identity characterized by an expression pattern different from hematopoietic cells or hepatocytes. The role of these BMDHs in the liver requires further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Blunted nocturnal dip of blood pressure (BP) and reversed circadian rhythm have been described in preeclampsia (PE). Non-dipper status and preeclampsia are both associated with an increased risk of cardiovascular disease later in life. Complete recovery of BP in PE is reported to occur over a variable period of time. Twenty-four hours-ambulatory blood pressure measurement (ABPM) in the post-partum follow-up after a PE has not been described. The aim of this study was to assess 24h-ambulatory blood pressure pattern after a PE and to determine the prevalence of non-dipper status, nocturnal hypertension, white coat hypertension and masked hypertension. METHODS: This is an observational, prospective study on women who suffered from a preeclampsia. A 24h-ABPM was done 6 weeks post-partum at the Hypertension Unit of the University Hospitals of Geneva, concomitantly with a clinical and biological evaluation. RESULTS: Forty-five women were included in a preliminary analysis. Mean age was 33±6years, 57.3% were Caucasian, mean BMI before pregnancy was 24±5kg/m(2). Office and ambulatory BP are shown in Table 1. Prevalence of nocturnal hypertension was high and half of the women had no nocturnal dipping. The diagnosis of hypertension based on office BP was discordant with the diagnosis based on ABPM in 25% of women. CONCLUSIONS: The prevalence of increased nighttime BP and abnormal BP pattern is high at 6weeks post-partum in preeclamptic women. Early assessment of BP with ABPM after preeclampsia allows an early identification of women with persistent circadian abnormalities who might be at increased risk. It also provides a more accurate assessment than office BP. DISCLOSURES: A. Ditisheim: None. B. Ponte: None. G. Wuerzner: None. M. Burnier: None. M. Boulvain: None. A. Pechère-Bertschi: None.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pancreatic adenocarcinoma is associated with a very poor prognosis, characterized with a 5-year survival rate of only 5%. Surgery is the only curative treatment for selected patients. Nevertheless, recurrence is very frequent. Identifying prognostic factors is thus warranted. Like numerous other tumors, adenocarcinomas are preceded by preneoplastic lesions. The role and the impact of these lesions remain unclear. This study aimed to assess the impact of the preneoplastic lesion pattern and histo-morphological features, on survival after pancreatic resection. Thirty-five patients who underwent pancreatic resection for pancreatic adenocarcinoma were identified from a prospective database of a single center, between 2003 and 2008. We considered demographics, tumor characteristics and type of treatment. The major outcome was survival. Analyzes were separated into two groups, according to the preneoplastic lesions: Pancreatic intraepithelial neoplasia (PanIN)-related carcinomas and intracanalar papillary mucinous neoplasia (IPMN)-related carcinomas. The former were more frequent, accounting for 63% (22/35). Moreover, they displayed more aggressive features, with a higher tumor stage (p = 0.01) and higher rate of positive lymph nodes (p = 0.019). Lymphatic (p = 0.009) and perinervous (p = 0.019) invasions were also more frequent. Survival was negatively influenced by PanIN preneoplastic lesions (p = 0.015), T3-4 tumor stage (p = 0.038), positive lymph nodes (p = 0.044), lymphatic (p = 0.019) and vascular (p = 0.029) invasions. Pancreatic adenocarcinoma displays different behavior according to its preneoplastic lesion. Indeed, PanIN-related adenocarcinoma showed more aggressive features and lower survival rate. Preneoplastic lesions may represent predictive factors for survival. Their role and predictive value should be investigated more thoroughly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:In the present study, the authors investigated the in vitrobehavior of radio-resistant breast adenocarcinoma (MDA-MB-231) cells line and radiosensitive peripheral blood mononuclear cells (PBMC), as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy.Materials and Methods:The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed.Results:Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation.Conclusion:Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.