989 resultados para Quantitative imaging
Resumo:
The subthalamic nucleus (STN) is a small, glutamatergic nucleus situated in the diencephalon. A critical component of normal motor function, it has become a key target for deep brain stimulation in the treatment of Parkinson's disease. Animal studies have demonstrated the existence of three functional sub-zones but these have never been shown conclusively in humans. In this work, a data driven method with diffusion weighted imaging demonstrated that three distinct clusters exist within the human STN based on brain connectivity profiles. The STN was successfully sub-parcellated into these regions, demonstrating good correspondence with that described in the animal literature. The local connectivity of each sub-region supported the hypothesis of bilateral limbic, associative and motor regions occupying the anterior, mid and posterior portions of the nucleus respectively. This study is the first to achieve in-vivo, non-invasive anatomical parcellation of the human STN into three anatomical zones within normal diagnostic scan times, which has important future implications for deep brain stimulation surgery.
Resumo:
As future treatments increasingly target the protein chemistry underlying the different dementias, itbecomes crucially important to distinguish between the dementias during life. Neither specific proteinnor genetic markers are as yet available in clinical practice. However, neuroimaging is an obviouscandidate technique that may yield enhanced diagnostic accuracy when applied to thedementias. The physiopathology and anatomopathology is complex in dementia with Lewy bodies(DLB). Besides the relative sparing of medial temporal lobe structures in DLB in comparison toAlzheimer's disease, no clear signature pattern of cerebral atrophy associated with DLB has beenestablished so far. Among others, one reason may be the difficulty in visualizing the small brainnuclei that are differentially involved among the dementias. While we think that structural magneticresonance imaging neuroimaging should be part of the diagnostic workup of most dementia syndromesdue to its usefulness in the differential diagnosis, its contribution to a positive diagnosis ofDLB is as yet limited. The development of different neuroimaging techniques may help distinguishreliably DLB from other neurodegenerative disorders. However, in order to become accepted as partof standard care, these techniques must still prove their effectiveness under routine conditions suchas those encountered by the general practitioner.
Resumo:
RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.
Resumo:
Background and Purpose Early prediction of motor outcome is of interest in stroke management. We aimed to determine whether lesion location at DTT is predictive of motor outcome after acute stroke and whether this information improves the predictive accuracy of the clinical scores. Methods We evaluated 60 consecutive patients within 12 hours of MCA stroke onset. We used DTT to evaluate CST involvement in the MC and PMC, CS, CR, and PLIC and in combinations of these regions at admission, at day 3, and at day 30. Severity of limb weakness was assessed using the m-NIHSS (5a, 5b, 6a, 6b). We calculated volumes of infarct and FA values in the CST of the pons. Results Acute damage to the PLIC was the best predictor associated with poor motor outcome, axonal damage, and clinical severity at admission (P&.001). There was no significant correlation between acute infarct volume and motor outcome at day 90 (P=.176, r=0.485). The sensitivity, specificity, and positive and negative predictive values of acute CST involvement at the level of the PLIC for 4 motor outcome at day 90 were 73.7%, 100%, 100%, and 89.1%, respectively. In the acute stage, DTT predicted motor outcome at day 90 better than the clinical scores (R2=75.50, F=80.09, P&.001). Conclusions In the acute setting, DTT is promising for stroke mapping to predict motor outcome. Acute CST damage at the level of the PLIC is a significant predictor of unfavorable motor outcome.
Resumo:
Es presenta un estudi retrospectiu descrivint les característiques radiològiques en una sèrie de nou casos de tumor fibrós solitari que affecta partes toves. Aquests resultats es comparen amb els resultats d’anatomia patològica i amb l’evolució clínica dels pacients
Resumo:
Despite the central role of quantitative PCR (qPCR) in the quantification of mRNA transcripts, most analyses of qPCR data are still delegated to the software that comes with the qPCR apparatus. This is especially true for the handling of the fluorescence baseline. This article shows that baseline estimation errors are directly reflected in the observed PCR efficiency values and are thus propagated exponentially in the estimated starting concentrations as well as 'fold-difference' results. Because of the unknown origin and kinetics of the baseline fluorescence, the fluorescence values monitored in the initial cycles of the PCR reaction cannot be used to estimate a useful baseline value. An algorithm that estimates the baseline by reconstructing the log-linear phase downward from the early plateau phase of the PCR reaction was developed and shown to lead to very reproducible PCR efficiency values. PCR efficiency values were determined per sample by fitting a regression line to a subset of data points in the log-linear phase. The variability, as well as the bias, in qPCR results was significantly reduced when the mean of these PCR efficiencies per amplicon was used in the calculation of an estimate of the starting concentration per sample.
Resumo:
The electromagnetic radiation at a terahertz frequencies (from 0.1 THz to 10 THz) is situated in the frequency band comprised between the optical band and the radio band. The interest of the scientific community in this frequency band has grown up due to its large capabilities to develop innovative imaging systems. The terahertz waves are able to generate extremely short pulses that achieve good spatial resolution, good penetration capabilities and allow to identify microscopic structures using spectral analysis. The work carried out during the period of the grant has been based on the developement of system working at the aforementioned frequency band. The main system is based on a total power radiometer working at 0.1 THz to perform security imaging. Moreover, the development of this system has been useful to gain knowledge in the behavior of the component systems at this frequency band. Moreover, a vectorial network analyzer has been used to characterize materials and perform active raster imaging. A materials measurement system has been designed and used to measure material properties as permittivity, losses and water concentration. Finally, the design of a terahertz time-domain spectrometer (THz-TDS) system has been started. This system will allow to perform tomographic measurement with very high penetration resolutions while allowing the spectral characterization of the sample material. The application range of this kind of system is very wide: from the identification of cancerous tissues of a skin to the characterization of the thickness of a painted surface of a car.
Resumo:
PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.
Resumo:
Introduction: Cognitive impairment affects 40-65% of multiple sclerosis (MS) patients, often since early stages of the disease (relapsing remitting MS, RRMS). Frequently affected functions are memory, attention or executive abilities but the most sensitive measure of cognitive deficits in early MS is the information processing speed (Amato, 2008). MRI has been extensively exploited to investigate the substrate of cognitive dysfunction in MS but the underlying physiopathological mechanisms remain unclear. White matter lesion load, whole-brain atrophy and cortical lesions' number play a role but correlations are in some cases modest (Rovaris, 2006; Calabrese, 2009). In this study, we aimed at characterizing and correlating the T1 relaxation times of cortical and sub-cortical lesions with cognitive deficits detected by neuropsychological tests in a group of very early RR MS patients. Methods: Ten female patients with very early RRMS (age: 31.6 ±4.7y; disease duration: 3.8 ±1.9y; EDSS disability score: 1.8 ±0.4) and 10 age- and gender-matched healthy volunteers (mean age: 31.2 ±5.8y) were included in the study. All participants underwent the following neuropsychological tests: Rao's Brief Repeatable Battery of Neuropsychological tests (BRB-N), Stockings of Cambridge, Trail Making Test (TMT, part A and B), Boston Naming Test, Hooper Visual Organization Test and copy of the Rey-Osterrieth Complex Figure. Within 2 weeks from neuropsychological assessment, participants underwent brain MRI at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil. The imaging protocol included 3D sequences with 1x1x1.2 mm3 resolution and 256x256x160 matrix, except for axial 2D-FLAIR: -DIR (T2-weighted, suppressing both WM and CSF; Pouwels, 2006) -MPRAGE (T1-weighted; Mugler, 1991) -MP2RAGE (T1-weighted with T1 maps; Marques, 2010) -FLAIR SPACE (only for patient 4-10, T2-weighted; Mugler, 2001) -2D Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix). Lesions were identified by one experienced neurologist and radiologist using all contrasts, manually contoured and assigned to regional locations (cortical or sub-cortical). Lesion number, volume and T1 relaxation time were calculated for lesions in each contrast and in a merged mask representing the union of the lesions from all contrasts. T1 relaxation times of lesions were normalized with the mean T1 value in corresponding control regions of the healthy subjects. Statistical analysis was performed using GraphPad InStat software. Cognitive scores were compared between patients and controls with paired t-tests; p values ≤ 0.05 were considered significant. Spearmann correlation tests were performed between the cognitive tests, which differed significantly between patients and controls, and lesions' i) number ii) volume iii) T1 relaxation time iv) disease duration and v) years of study. Results: Cortical and sub-cortical lesions count, T1 values and volume are reported in Table 1 (A and B). All early RRMS patients showed cortical lesions (CLs) and the majority consisted of CLs type I (lesions with a cortical component extending to the sub-cortical tissue). The rest of cortical lesions were characterized as type II (intra-cortical lesions). No type III/IV lesions (large sub-pial lesions) were detected. RRMS patients were slightly less educated (13.5±2.5y vs. 16.3±1.8y of study, p=0.02) than the controls. Signs of cortical dysfunction (i.e. impaired learning, language, visuo-spatial skills or gnosis) were rare in all patients. However, patients showed on average lower scores on measures of visual attention and information processing speed (TMT-part A: p=0.01; TMT-part B: p=0.006; PASAT-included in the BRB-N: p=0.04). The T1 relaxation values of CLs type I negatively correlated with the TMT-part A score (r=0.78, p<0.01). The correlations of TMT-part B score and PASAT score with T1 relaxation time of lesions as well and the correlation between TMT-part A, TMT-part B and PASAT score with lesions' i) number ii) volume iii) disease duration and iv) years of study did not reach significance. In order to preclude possible influences from partial volume effects on the T1 values, the correlation between lesion volume and T1 value of CLs type I was calculated; no correlation was found, suggesting that partial volume effects did not affect the statistics. Conclusions: The present pilot study reports for the first time the presence and the T1 characteristics at 3 T of cortical lesions in very early RRMS (< 6 y disease duration). It also shows that CLS type I represents the most frequent cortical lesion type in this cohort of RRMS patients. In addition, it reveals a negative correlation between the attentional test TMT-part A and the T1 properties of cortical lesions type I. In other words, lower attention deficits are concomitant with longer T1-relaxation time in cortical lesions. In respect to this last finding, it could be speculated that long relaxation time correspond to a certain degree of tissue loss that is enough to stimulate compensatory mechanisms. This hypothesis is in line with previous fMRI studies showing functional compensatory mechanisms to help maintaining normal or sub-normal attention performances in RR MS patients (Penner, 2003).
Resumo:
La localització d'òrgans és un tòpic important en l'àmbit de la imatge mèdica per l'ajuda del tractament i diagnosi del càncer. Un exemple es pot trobar en la cal•libració de models farmacoquinètics. Aquesta pot ésser realitzada utilitzant un teixit de referència, on, per exemple en imatges de ressonància magnètica de pit, una correcta segmentació del múscul pectoral és necessària per a la detecció de signes de malignitat. Els mètodes de segmentació basat en atlas han estat altament avaluats en imatge de ressonància magnètica de cervell, obtenint resultats satisfactoris. En aquest projecte, en col•laboració amb el el Diagnostic Image Analysis Group de la Radboud University Nijmegen Medical Centre i la supervisió del Dr. N.Karssemeijer, es presenta la primera aproximació d'un mètode de segmentació basat en atlas per segmentar els diferents teixits visibles en imatges de ressonància magnètica (T1) del pit femení. L'atlas consisteix en 5 estructures (teixit greixòs, teixit dens, cor, pulmons i múscul pectoral) i ha estat utilitzat en un algorisme de segmentació Bayesià per tal de delinear les esmentades estructures. A més a més, s'ha dut a terme una comparació entre un mètode de registre global i un de local, utilitzats tant en la construcció de l'atlas com en la fase de segmentació, essent el primer el que ha presentat millors resultats en termes d'eficiència i precisió. Per a l'avaluació, s'ha dut a terme una comparació visual i numèrica entre les segmentacions obtingudes i les realitzades manualment pels experts col•laboradors. Pel que fa a la numèrica, s'ha emprat el coeficient de similitud de Dice ( mesura que dóna valors entre 0 i 1, on 0 significa no similitud i 1 similitud màxima) i s'ha obtingut una mitjana general de 0.8. Aquest resultat confirma la validesa del mètode presentat per a la segmentació d'imatges de ressonància magnètica del pit.
Resumo:
Introduction Lesion detection in multiple sclerosis (MS) is an essential part of its clinical diagnosis. In addition, radiological characterisation of MS lesions is an important research field that aims at distinguishing different MS types, monitoring drug response and prognosis. To date, various MR protocols have been proposed to obtain optimal lesion contrast for early and comprehensive diagnosis of the MS disease. In this study, we compare the sensitivity of five different MR contrasts for lesion detection: (i) the DIR sequence (Double Inversion Recovery, [4]), (ii) the Dark-fluid SPACE acquisition schemes, a 3D variant of a 2D FLAIR sequence [1], (iii) the MP2RAGE [2], an MP-RAGE variant that provides homogeneous T1 contrast and quantitative T1-values, and the sequences currently used for clinical MS diagnosis (2D FLAIR, MP-RAGE). Furthermore, we investigate the T1 relaxation times of cortical and sub-cortical regions in the brain hemispheres and the cerebellum at 3T. Methods 10 early-stage female MS patients (age: 31.64.7y; disease duration: 3.81.9y; disability score, EDSS: 1.80.4) and 10 healthy controls (age and gender-matched: 31.25.8y) were included in the study after obtaining informed written consent according to the local ethic protocol. All experiments were performed at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil [5]. The imaging protocol included the following sequences, (all except for axial FLAIR 2D with 1x1x1.2 mm3 voxel and 256x256x160 matrix): DIR (TI1/TI2/TR XX/3652/10000 ms, iPAT=2, TA 12:02 min), MP-RAGE (TI/TR 900/2300 ms, iPAT=3, TA 3:47 min); MP2RAGE (TI1/TI2/TR 700/2500/5000 ms, iPAT=3, TA 8:22 min, cf. [2]); 3D FLAIR SPACE (only for patient 4-6, TI/TR 1800/5000 ms, iPAT=2, TA=5;52 min, cf. [1]); Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix, TI/TR 2500/9000 ms, iPAT=2, TA 4:05 min). Lesions were identified by two experienced neurologist and radiologist, manually contoured and assigned to regional locations (s. table 1). Regional lesion masks (RLM) from each contrast were compared for number and volumes of lesions. In addition, RLM were merged in a single "master" mask, which represented the sum of the lesions of all contrasts. T1 values were derived for each location from this mask for patients 5-10 (3D FLAIR contrast was missing for patient 1-4). Results & Discussion The DIR sequence appears the most sensitive for total lesions count, followed by the MP2RAGE (table 1). The 3D FLAIR SPACE sequence turns out to be more sensitive than the 2D FLAIR, presumably due to reduced partial volume effects. Looking for sub-cortical hemispheric lesions, the DIR contrast appears to be equally sensitive to the MP2RAGE and SPACE, but most sensitive for cerebellar MS plaques. The DIR sequence is also the one that reveals cortical hemispheric lesions best. T1 relaxation times at 3T in the WM and GM of the hemispheres and the cerebellum, as obtained with the MP2RAGE sequence, are shown in table 2. Extending previous studies, we confirm overall longer T1-values in lesion tissue and higher standard deviations compared to the non-lesion tissue and control tissue in healthy controls. We hypothesize a biological (different degree of axonal loss and demyelination) rather than technical origin. Conclusion In this study, we applied 5 MR contrasts including two novel sequences to investigate the contrast of highest sensitivity for early MS diagnosis. In addition, we characterized for the first time the T1 relaxation time in cortical and sub-cortical regions of the hemispheres and the cerebellum. Results are in agreement with previous publications and meaningful biological interpretation of the data.
Resumo:
RATIONALE AND OBJECTIVES: Dose reduction may compromise patients because of a decrease of image quality. Therefore, the amount of dose savings in new dose-reduction techniques needs to be thoroughly assessed. To avoid repeated studies in one patient, chest computed tomography (CT) scans with different dose levels were performed in corpses comparing model-based iterative reconstruction (MBIR) as a tool to enhance image quality with current standard full-dose imaging. MATERIALS AND METHODS: Twenty-five human cadavers were scanned (CT HD750) after contrast medium injection at different, decreasing dose levels D0-D5 and respectively reconstructed with MBIR. The data at full-dose level, D0, have been additionally reconstructed with standard adaptive statistical iterative reconstruction (ASIR), which represented the full-dose baseline reference (FDBR). Two radiologists independently compared image quality (IQ) in 3-mm multiplanar reformations for soft-tissue evaluation of D0-D5 to FDBR (-2, diagnostically inferior; -1, inferior; 0, equal; +1, superior; and +2, diagnostically superior). For statistical analysis, the intraclass correlation coefficient (ICC) and the Wilcoxon test were used. RESULTS: Mean CT dose index values (mGy) were as follows: D0/FDBR = 10.1 ± 1.7, D1 = 6.2 ± 2.8, D2 = 5.7 ± 2.7, D3 = 3.5 ± 1.9, D4 = 1.8 ± 1.0, and D5 = 0.9 ± 0.5. Mean IQ ratings were as follows: D0 = +1.8 ± 0.2, D1 = +1.5 ± 0.3, D2 = +1.1 ± 0.3, D3 = +0.7 ± 0.5, D4 = +0.1 ± 0.5, and D5 = -1.2 ± 0.5. All values demonstrated a significant difference to baseline (P < .05), except mean IQ for D4 (P = .61). ICC was 0.91. CONCLUSIONS: Compared to ASIR, MBIR allowed for a significant dose reduction of 82% without impairment of IQ. This resulted in a calculated mean effective dose below 1 mSv.
Resumo:
BACKGROUND: The cerebellum is a complex structure that can be affected by several congenital and acquired diseases leading to alteration of its function and neuronal circuits. Identifying the structural bases of cerebellar neuronal networks in humans in vivo may provide biomarkers for diagnosis and management of cerebellar diseases. OBJECTIVES: To define the anatomy of intrinsic and extrinsic cerebellar circuits using high-angular resolution diffusion spectrum imaging (DSI). METHODS: We acquired high-resolution structural MRI and DSI of the cerebellum in four healthy female subjects at 3T. DSI tractography based on a streamline algorithm was performed to identify the circuits connecting the cerebellar cortex with the deep cerebellar nuclei, selected brainstem nuclei, and the thalamus. RESULTS: Using in-vivo DSI in humans we were able to demonstrate the structure of the following cerebellar neuronal circuits: (1) connections of the inferior olivary nucleus with the cerebellar cortex, and with the deep cerebellar nuclei (2) connections between the cerebellar cortex and the deep cerebellar nuclei, (3) connections of the deep cerebellar nuclei conveyed in the superior (SCP), middle (MCP) and inferior (ICP) cerebellar peduncles, (4) complex intersections of fibers in the SCP, MCP and ICP, and (5) connections between the deep cerebellar nuclei and the red nucleus and the thalamus. CONCLUSION: For the first time, we show that DSI tractography in humans in vivo is capable of revealing the structural bases of complex cerebellar networks. DSI thus appears to be a promising imaging method for characterizing anatomical disruptions that occur in cerebellar diseases, and for monitoring response to therapeutic interventions.
Resumo:
Shigella, a Gram-negative invasive enteropathogenic bacterium responsible for bacillary dysentery, causes the rupture, invasion, and inflammatory destruction of the human colonic mucosa. We explored the mechanisms of protection mediated by Shigella LPS-specific secretory IgA (SIgA), the major mucosal Ab induced upon natural infection. Bacteria, SIgA, or SIgA-S. flexneri immune complexes were administered into rabbit ligated intestinal loops containing a Peyer's patch. After 8 h, localizations of bacteria, SIgA, and SIgA-S. flexneri immune complexes were examined by immunohistochemistry and confocal microscopy imaging. We found that anti-Shigella LPS SIgA, mainly via immune exclusion, prevented Shigella-induced inflammation responsible for the destruction of the intestinal barrier. Besides this luminal trapping, a small proportion of SIgA-S. flexneri immune complexes were shown to enter the rabbit Peyer's patch and were internalized by dendritic cells of the subepithelial dome region. Local inflammatory status was analyzed by quantitative RT-PCR using newly designed primers for rabbit pro- and anti-inflammatory mediator genes. In Peyer's patches exposed to immune complexes, limited up-regulation of the expression of proinflammatory genes, including TNF-alpha, IL-6, Cox-2, and IFN-gamma, was observed, consistent with preserved morphology. In contrast, in Peyer's patches exposed to Shigella alone, high expression of the same mediators was measured, indicating that neutralizing SIgA dampens the proinflammatory properties of Shigella. These results show that in the form of immune complexes, SIgA guarantees both immune exclusion and neutralization of translocated bacteria, thus preserving the intestinal barrier integrity by preventing bacterial-induced inflammation. These findings add to the multiple facets of the noninflammatory properties of SIgA.