880 resultados para Point-of-care systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arthrocentesis, injection and infiltration of joints and soft tissues belong to the basic procedures in rheumatology. The indications and the practical performance are based on experience and tradition. Nowadays, a crucial reappraisal and adaption of indications and technical aspects appear important in the light of new evidence and technical developments. The main indications for puncture remain the search of an infectious arthritis and reduction of intra-articular pressure due to effusion. Good indications for the injection of glucocorticoids are inflammation in sterile joints and activated osteoarthritis. The local infiltration with corticosteroids in mechanically induced enthesopathies at the lateral epicondyle of the humerus or at the plantar fascia have to be questioned in the light of recent publications which show that this common practice is associated with a poorer outcome than without injection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background and Aims: Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. Subjects and Methods: Two CGM sensors were inserted simultaneously in the abdomen on either side of 20 individuals with type 1 diabetes. One sensor was calibrated predominantly using preprandial glucose (calibration(PRE)). The other sensor was calibrated predominantly using postprandial glucose (calibration(POST)). At minimum three additional glucose values per day were obtained for analysis of accuracy. Sensor readings were divided into four categories according to the glycemic range of the reference values (low, ≤4 mmol/L; euglycemic, 4.1-7 mmol/L; hyperglycemic I, 7.1-14 mmol/L; and hyperglycemic II, >14 mmol/L). Results: The overall mean±SEM absolute relative difference (MARD) between capillary reference values and sensor readings was 18.3±0.8% for calibration(PRE) and 21.9±1.2% for calibration(POST) (P<0.001). MARD according to glycemic range was 47.4±6.5% (low), 17.4±1.3% (euglycemic), 15.0±0.8% (hyperglycemic I), and 17.7±1.9% (hyperglycemic II) for calibration(PRE) and 67.5±9.5% (low), 24.2±1.8% (euglycemic), 15.5±0.9% (hyperglycemic I), and 15.3±1.9% (hyperglycemic II) for calibration(POST). In the low and euglycemic ranges MARD was significantly lower in calibration(PRE) compared with calibration(POST) (P=0.007 and P<0.001, respectively). Conclusions: Sensor calibration predominantly based on preprandial glucose resulted in a significantly higher overall sensor accuracy compared with a predominantly postprandial calibration. The difference was most pronounced in the hypo- and euglycemic reference range, whereas both calibration patterns were comparable in the hyperglycemic range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ROTEM® is considered a helpful point-of-care device to monitor blood coagulation in emergency situations. Centrally performed analysis is desirable but rapid transport of blood samples is an important prerequisite. The effect of acceleration forces on sample transport through a pneumatic tube system on ROTEM® should be tested at each institution to exclude a pre-analytical influence. The aims of the present work were: (i) to investigate the effect of pneumatic tube transport on ROTEM® parameters; (ii) to compare blood sample transport via pneumatic tube vs. manual transportation; and (iii) to determine the effect of acceleration forces on ROTEM® parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alternans of cardiac action potential duration (APD) is a well-known arrhythmogenic mechanism which results from dynamical instabilities. The propensity to alternans is classically investigated by examining APD restitution and by deriving APD restitution slopes as predictive markers. However, experiments have shown that such markers are not always accurate for the prediction of alternans. Using a mathematical ventricular cell model known to exhibit unstable dynamics of both membrane potential and Ca2+ cycling, we demonstrate that an accurate marker can be obtained by pacing at cycle lengths (CLs) varying randomly around a basic CL (BCL) and by evaluating the transfer function between the time series of CLs and APDs using an autoregressive-moving-average (ARMA) model. The first pole of this transfer function corresponds to the eigenvalue (λalt) of the dominant eigenmode of the cardiac system, which predicts that alternans occurs when λalt≤−1. For different BCLs, control values of λalt were obtained using eigenmode analysis and compared to the first pole of the transfer function estimated using ARMA model fitting in simulations of random pacing protocols. In all versions of the cell model, this pole provided an accurate estimation of λalt. Furthermore, during slow ramp decreases of BCL or simulated drug application, this approach predicted the onset of alternans by extrapolating the time course of the estimated λalt. In conclusion, stochastic pacing and ARMA model identification represents a novel approach to predict alternans without making any assumptions about its ionic mechanisms. It should therefore be applicable experimentally for any type of myocardial cell.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Goitre recurrence is a common problem following subtotal thyroid gland resection for multinodular goitre disease. The aim of the present study was to evaluate morbidity rate in relation to the side of initial and redo-surgery for recurrent disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: This project is part of an evaluation of complementary and alternative medicine (CAM) aimed at providing a scientific basis for the Swiss Government to include 5 CAM methods in basic health coverage: anthroposophic medicine, homeopathy, neural therapy, phytotherapy and Traditional Chinese Medicine (TCM). OBJECTIVES: The objective was to explore the philosophy of care (convictions and values, priorities in medical activity, motivation for CAM, criteria for the practice of CAM, limits of the used methods) of conventional and CAM general practitioners (GPs) and to determine differences between both groups. MATERIALS AND METHODS: This study was a cross-sectional survey of a representative sample of 623 GPs who provide complementary or conventional primary care. A mailed questionnaire with open-ended questions focusing on the philosophy of care was used for data collection. An appropriate methodology using a combination of quantitative and qualitative approaches was developed. RESULTS: Significant differences between both groups include philosophy of care (holistic versus positivistic approaches), motivation for CAM (intrinsic versus extrinsic) and priorities in medical activity. Both groups seem to be aware of limitations of the therapeutic methods used. The study reveals that conventional physicians are also using complementary medicine. DISCUSSION: Our study provides a wealth of data documenting several aspects of physicians' philosophy of care as well as differences and similarities between conventional and complementary care. Implications of the study with regard to quality of care as well as ethical and health policy issues should be investigated further.