960 resultados para Photon Conversion
Resumo:
Referred to as orthographic depth, the degree of consistency of grapheme/phoneme correspondences varies across languages from high in shallow orthographies to low in deep orthographies. The present study investigates the impact of orthographic depth on reading route by analyzing evoked potentials to words in a deep (French) and shallow (German) language presented to highly proficient bilinguals. ERP analyses to German and French words revealed significant topographic modulations 240-280ms post-stimulus onset, indicative of distinct brain networks engaged in reading over this time window. Source estimations revealed that these effects stemmed from modulations of left insular, inferior frontal and dorsolateral regions (German>French) previously associated to phonological processing. Our results show that reading in a shallow language was associated to a stronger engagement of phonological pathways than reading in a deep language. Thus, the lexical pathways favored in word reading are reinforced by phonological networks more strongly in the shallow than deep orthography.
Resumo:
With the development of the water calorimeter direct measurement of absorbed dose in water becomes possible. This could lead to the establishment of an absorbed dose rather than an exposure related standard for ionization chambers for high energy electrons and photons. In changing to an absorbed dose standard it is necessary to investigate the effect of different parameters, among which are the energy dependence, the air volume, wall thickness and material of the chamber. The effect of these parameters is experimentally studied and presented for several commercially available chambers and one experimental chamber, for photons up to 25 MV and electrons up to 20 MeV, using a water calorimeter as the absorbed dose standard and the most recent formalism to calculate the absorbed dose with ion chambers.^ For electron beams, the dose measured with the calorimeter was 1% lower than the dose calculated with the chambers, independent of beam energy and chamber.^ For photon beams, the absorbed dose measured with the calorimeter was 3.8% higher than the absorbed dose calculated from the chamber readings. Such differences were found to be chamber and energy independent.^ The results for the photons were found to be statistically different from the results with the electron beams. Such difference could not be attributed to a difference in the calorimeter response. ^
Resumo:
u.a.: Lizardi, Bansa;
Resumo:
Radiation therapy has been used as an effective treatment for malignancies in pediatric patients. However, in many cases, the side effects of radiation diminish these patients’ quality of life. In order to develop strategies to minimize radiogenic complications, one must first quantitatively estimate pediatric patients’ relative risk for radiogenic late effects, which has not become feasible till recently because of the calculational complexity. The goals of this work were to calculate the dose delivered to tissues and organs in pediatric patients during contemporary photon and proton radiotherapies; to estimate the corresponding risk of radiogenic second cancer and cardiac toxicity based on the calculated doses and on dose-risk models from the literature; to test for the statistical significance of the difference between predicted risks after photon versus proton radiotherapies; and to provide a prototype of an evidence-based approach to selecting treatment modalities for pediatric patients, taking second cancer and cardiac toxicity into account. The results showed that proton therapy confers a lower predicted risk of radiogenic second cancer, and lower risks of radiogenic cardiac toxicities, compared to photon therapy. An uncertainty analysis revealed that the qualitative findings of this study are insensitive to changes in a wide variety of host and treatment related factors.
Resumo:
Measurement of the absorbed dose from ionizing radiation in medical applications is an essential component to providing safe and reproducible patient care. There are a wide variety of tools available for measuring radiation dose; this work focuses on the characterization of two common, solid-state dosimeters in medical applications: thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD). There were two main objectives to this work. The first objective was to evaluate the energy dependence of TLD and OSLD for non-reference measurement conditions in a radiotherapy environment. The second objective was to fully characterize the OSLD nanoDot in a CT environment, and to provide validated calibration procedures for CT dose measurement using OSLD. Current protocols for dose measurement using TLD and OSLD generally assume a constant photon energy spectrum within a nominal beam energy regardless of measurement location, tissue composition, or changes in beam parameters. Variations in the energy spectrum of therapeutic photon beams may impact the response of TLD and OSLD and could thereby result in an incorrect measure of dose unless these differences are accounted for. In this work, we used a Monte Carlo based model to simulate variations in the photon energy spectra of a Varian 6MV beam; then evaluated the impact of the perturbations in energy spectra on the response of both TLD and OSLD using Burlin Cavity Theory. Energy response correction factors were determined for a range of conditions and compared to measured correction factors with good agreement. When using OSLD for dose measurement in a diagnostic imaging environment, photon energy spectra are often referenced to a therapy-energy or orthovoltage photon beam – commonly 250kVp, Co-60, or even 6MV, where the spectra are substantially different. Appropriate calibration techniques specifically for the OSLD nanoDot in a CT environment have not been presented in the literature; furthermore the dependence of the energy response of the calibration energy has not been emphasized. The results of this work include detailed calibration procedures for CT dosimetry using OSLD, and a full characterization of this dosimetry system in a low-dose, low-energy setting.
Resumo:
Supported file formats: - CrossRef XML file(s) - TRiDaS (Tree Ring Data Standard, http://www.tridas.org). Example: hdl:10013/epic.42747.d001 - IMMA (International Maritime Meteorological Archive). Used by the project CLIWOC (García-Herrera et al. 2007, http://doi.pangaea.de/10.1594/PANGAEA.743343) - NOAA IOAS (International Ocean Atlas Series). Example: hdl:10013/epic.42747.d008 - SOCAT (Surface Ocean CO2 Atlas, Bakker et al. 2014, http://doi.pangaea.de/10.1594/PANGAEA.811776) - CHUAN (Comprehensive Historical Upper-Air Network, Stickler et al. 2013, http://doi.pangaea.de/10.1594/PANGAEA.821222). Example: hdl:10013/epic.42747.d003 - Thermosalinograph (TSG) data. Format developed by Gerd Rohardt. Example: hdl:10013/epic.42747.d002 - Columus GPS Data Logger V-900 format to KML or GPX. Example: hdl:10013/epic.42747.d006
Resumo:
In the early stages of the development of Japan’s environmental policy, sulfur oxide (SOx) emissions, which seriously damage health, was the most important air pollution problem. In the second half of the 1960s and the first half of the 1970s, the measures against SOx emissions progressed quickly, and these emissions were reduced drastically. The most important factor of the reduction was the conversion to a low-sulfur fuel for large-scale fuel users, such as the electric power industry. However, industries started conversion to low-sulfur fuel not due to environmental concerns, but simply to reduce costs. Furthermore, the interaction among the various interests of the electric power industry, oil refineries, the central government, local governments, and citizens over the energy and environmental policies led to the measures against SOx emissions by fuel conversion.
Resumo:
The effects of conversion treatments, depending on ecological factors and silvicultural parameters (thinning intensity, thinning type and rotation, among others) have been studied during the last fifteen years in an experimental trial in Central Spain. The general climate is continental Mediterranean; soils are low depth and limy; vegetation is an homogeneous dense coppices of Quercus ilex with isolated Pinus nigra trees. The experimental design (three locations) includes different thinning intensities (from 0 to 100% of extracted basal area). Inventories have been carried out in 1994 and 2010; thinning treatments were done in 1995 and 2011. Analysis of the effects of the conversion treatment show the increment of diameter and height growth rates, the canopy recovery and the stand resprouting, finding differences in these effects between thinning treatments. Besides the induced changes at holm oak stand, the application of conversion treatment clearly changed the woodland dynamics. Fifteen years after the thinnings, floristic composition varied and an abundant pine regeneration was installed in the woodland. In this work we describe the changes between inventories in tree species composition and diameter distribution, specially in the case of black pine. The conversion treatment caused changes in forest dynamics in the short term, increasing biodiversity and diversifying the forest structure. The fast installation of Pinus regeneration suggests the potential of the zone for the establishment of multipurpose mixed Quercus-Pinus stands in wide areas where Quercus species were favoured by human populations for firewood production. Conversion treatment of coppices, with the creation of mixed stands, constitutes a good management alternative for extensive areas and an interesting technique to adaptation to global change.