930 resultados para Periodical breathing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of a specific orbit and the procedure to calculate orbital maneuvers of artificial satellites are problems of extreme importance in the study of orbital mechanics. Therefore, the transferring problem of a spaceship from one orbit to another, and the attention due to this subject has in increased during the last years. Many applications can be found in several space activities, for example, to put a satellite in a geostationary orbit, to change the position of a spaceship, to maintain a specific satellite's orbit, in the design of an interplanetary mission, and others. The Brazilian Satellite SCD-1 (Data Collecting Satellite) will be used as example in this paper. It is the first satellite developed entirely in Brazil, and it remains in operation to this date. SCD-1 was designed, developed, built, and tested by Brazilian scientists, engineers, and technicians working at INPE (National Institute for Space Research, and in Brazilian Industries. During the lifetime, it might be necessary do some complementary maneuvers, being this one either an orbital transferring, or just to make periodical corrections. The purpose of transferring problem is to change the position, velocity and the satellite's mass to a new pre determined state. This transfer can be totally linked (in the case of "Rendezvous") or partially free (free time, free final velocity, etc). In the global case, the direction, the orientation and the magnitude of the thrust to be applied must be chosen, respecting the equipment's limit. In order to make this transferring, either sub-optimal or optimal maneuvers may be used. In the present study, only the sub-optimal will be shown. Hence, this method will simplify the direction of thrust application, to allow a fast calculation that may be used in real time, with a very fast processing. The thrust application direction to be applied will be assumed small and constant, and the purpose of this paper is to find the time interval that the thrust is applied. This paper is basically divided into three parts: during the first one the sub-optimal maneuver is explained and detailed, the second presents the Satellite SCD-1, and finally the last part shows the results using the sub-optimal maneuver applied to the Brazilian Satellite.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synchronism is the efetivation of the same behavior at the same time by two or more individuals. In cetology only from 2000 we verify an increasing of efforts for studies of synchronic behaviors. The synchronism in cetaceans was reported for a variety of contexts, including feeding, socializing, parental care, while resting, traveling and play, during afilliation, in sexual behaviour and possible while teaching. The synchronism in behavior is influenced by environmental factors and can be modified during stress situations such as the presence of boats. The aim of this study is to explore behavior synchronism presented by the estuarine dolphin (Sotalia guianensis) in Pipa, Rio Grande do Norte state, Northeastern Brazil. A total of 414 hours of observation during the year 2006, using scan sampling method, from a land based sighting was conducted. Analyses were conducted in four steps. Firstly, we determined the pattern of activity of the groups within the bay, testing for the influence of bay configuration before and after rains periods on the activity of animals. Analyses show that forage occurs more frequently after the rainy period, but there was no change in the number of individuals or spatial cohesions between them. Secondly, we analysed the influence of turism boat traffic on the behavior of animals. We verified no changes on the bahavior of animals during the presence of boats. Finally, we tested seven hypotheses regarding the ecological and social dynamics of synchronic behavior. Environmental aspects were considered the main influence for the synchronism, no influences of age, and more selective exihibition of synchronic breathing in feeding and social displays were observed during the study period

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A diminuição da densidade mineral óssea das vértebras, própria do processo de envelhecimento e que pode ser agravada pela osteoporose, determina uma diminuição da região anterior dos corpos vertebrais, resultando em compressão e colapso dessas vértebras, com maior estreitamento dos discos e espaços intervertebrais. Essas novas condições interferem no funcionamento normal de órgãos e sistemas do organismo. O objetivo foi avaliar o grau de cifose torácica e a capacidade funcional de mulheres idosas com e sem osteoporose. Foram avaliadas 30 idosas ativas fisicamente, sendo 20 sem osteoporose ( GSO: 65,1± 4,67 anos) e 10 idosas com osteoporose (GCO: 68,6± 6,46anos). Foram avaliados a medida da cifose torácica, teste de caminhada de seis minutos (TC6'), Timed Up and go (TUG) e força dos músculos respiratórios (PImáx e PEmáx). Os dados obtidos foram analisados utilizando o teste t de Student. O nível de significância utilizado foi de 5% (α£ 0,05). Houve diferença significativa entre os grupos sem (GSO) e com osteoporose (GCO) somente no TC6'(GSO: 426,63±46,36 m; GCO: 392,64±36,68 m , α =0,02). As outras variáveis analisadas não apresentaram diferença significativa (Cifose torácica: α = 0,17; TUG: α =0,49; PImax: α =0,45; PEmax: α =0,19). A osteoporose não influenciou o grau de cifose torácica, a força dos músculos respiratórios e mobilidade das idosas. Entretanto, o desempenho no TC6' foi influenciado negativamente pela osteoporose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TEMA: medidas da dinâmica respiratória são freqüentemente utilizadas na clínica fonoaudiológica, mas poucos são os dados científicos destas na população infantil. OBJETIVO: estudar a dinâmica respiratória entre crianças que respiram pelo modo nasal. MÉTODO: o estudo foi realizado com uma amostra aleatória estratificada de 106 crianças respiradoras nasais de escolas da cidade de Marília / SP, entre quatro e dez anos de ambos os sexos. Foram realizadas as medidas de capacidade vital (CV), nas posições em pé e sentada, com e sem oclusão nasal; de tempo máximo de fonação (TMF) de vogais e consoantes sustentadas, além de fala em seqüência com a contagem de números. RESULTADOS: a medida média da CV na posição em pé com e sem oclusão nasal foi 1515,56 ml e 1538,67 ml respectivamente e na posição sentada, 1524 ml e 1539,15 ml respectivamente; o TMF das vogais em segundos foi: /a/ = 8,32 , /i/ = 8,61 e /u/ 8,42; o de consoantes foi: /s/ = 6,64 e /z/ = 7,65 e o de seqüência de números foi de 7,76 segundos. Resultados: observou-se que o tempo médio destas medidas aumentou progressivamente conforme as faixas etárias. Tanto para o TMF das vogais como, para o das consoantes, houve diferença estatística significante (p < 0,05) nas idades mais distantes, ou seja, entre quatro e dez anos, quatro e nove, e quatro e oito anos. em faixas etárias consecutivas não houve diferença estatística significante nos valores de CV. Houve forte associação entre a CV e o crescimento físico da criança. CONCLUSÃO: esse estudo mostrou medidas de dinâmica respiratória em crianças que podem ser úteis no diagnóstico e terapia fonoaudiológica. Outras pesquisas deveriam ser desenvolvidas para adicionais informações sobre o assunto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar qualidade do serviço prestado aos pacientes de cirurgia cardíaca no período hospitalar, em serviço do SUS, identificando as expectativas e percepções dos pacientes. Relacionar qualidade de serviço com gênero, faixa etária e circulação extracorpórea. MÉTODOS: Estudaram-se 82 pacientes (52,4% do sexo feminino e 47,6% do masculino) submetidos a cirurgia cardíaca eletiva, operados por toracotomia médio-esternal, idade: 31 a 83 anos (média 60,4 ± 13,2 anos), período: março a setembro de 2006. Avaliou-se a qualidade do serviço em dois momentos: expectativas no pré-operatório e percepções do atendimento recebido no 6º dia de pós-operatório; mediante aplicação da escala SERVQUAL modificada (SERVQUAL-Card). O resultado foi obtido pela diferença da somatória das notas das percepções e expectativas por meio de análise estatística. RESULTADOS: A escala SERVQUAL-Card foi validada estatisticamente, apresentando adequado índice de consistência interna. Encontrou-se maior frequência de revascularização do miocárdio 55 (67,0%); primeira cirurgia cardíaca 72 (87,8%) e utilização de CEC 69 (84,1%). Verificaram-se altos valores para expectativas e percepções, com resultados significantes (P<0,05). Observou-se relação significante entre qualidade de serviço com gênero, na empatia (P=0,04) e faixa etária, na confiabilidade (P=0,02). Não se observou significância entre CEC e qualidade de serviço. CONCLUSÃO: A qualidade dos serviços foi satisfatória. O paciente demonstrou expectativa alta ao serviço médicohospitalar. Mulheres apresentaram maior percepção da qualidade na empatia, jovens na confiabilidade. A utilização de CEC não está relacionada com qualidade do serviço nesta amostra. Os dados obtidos sugerem que a qualidade deste serviço de saúde pode ser monitorada pelo emprego periódico da escala SERQUAL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To compare the cardiorespiratory effects and incidence of gastroesophageal reflux with the use of a laryngeal mask airway (LMA) or endotracheal tube (ET) in anesthetized cats during spontaneous (SV) or controlled ventilation (CV).Study design Prospective randomized experimental trial.Animals Thirty-two adult crossbred cats, weighing 2.7 +/- 0.4 kg.Methods the cats were sedated with intramuscular (IM) methotrimeprazine (0.5 mg kg(-1)) and buprenorphine (0.005 mg kg(-1)), followed 30 minutes later by induction of anesthesia with intravenous (IV) thiopental (12.5-20 mg kg(-1)). An ET was used in 16 cats and an LMA in the remaining 16 animals. Anesthesia was maintained with 0.5 minimum alveolar concentration (0.6%) of halothane in oxygen using a Mapleson D breathing system. Cats in both groups were further divided into two equal groups (n = 8), undergoing either SV or CV. Neuromuscular blockade with pancuronium (0.06 mg kg(-1)) was used to facilitate CV. Heart and respiratory rates, direct arterial blood pressure, capnometry (PE'CO2) and arterial blood gases were measured. Gastric reflux and possible aspiration was investigated by intragastric administration of 5 mL of radiographic contrast immediately after induction of anesthesia. Cervical and thoracic radiographs were taken at the end of anesthesia. Data were analyzed using ANOVA followed by Student-Newman-Keuls, Kruskal-Wallis or Friedman test where appropriate.Results Values for PaCO2 and PE'CO2 were higher in spontaneously breathing cats with the LMA when compared with other groups. Values of PaO2 and hemoglobin oxygen saturation did not differ between groups. Gastroesophageal reflux occurred in four of eight and two of eight cats undergoing CV with ET or LMA, respectively. There was no tracheal or pulmonary aspiration in any cases.Conclusions and clinical relevance the use of an LMA may be used as an alternative to endotracheal intubation in anesthetized cats. Although aspiration was not observed, gastric reflux may occur in mechanically ventilated animals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito da utilização de um programa de treinamento específico dos músculos respiratórios sobre a função pulmonar em indivíduos tabagistas. MÉTODOS: Foram estudados 50 indivíduos tabagistas assintomáticos com idade superior a 30 anos, nos seguintes momentos: A0 - avaliação inicial seguida do protocolo de exercícios respiratórios; A1 - reavaliação após 10 minutos da aplicação do protocolo; e A2 -reavaliação final após duas semanas de treinamento utilizando o mesmo protocolo três vezes por semana. A avaliação foi realizada através das medidas de pressões respiratórias máximas (PImax. e PEmax.), picos de fluxo respiratórios (PFI e PFE), ventilação voluntária máxima (VVM), capacidade vital Forçada (CVF) e Volume expiratório forçado no primeiro segundo (VEF1). RESULTADOS: Não houve melhora na CVF e VEF1 da avaliação inicial para a final. Houve aumento significativo das variáveis PFI, PFE, VVM e PImax nas avaliações A1 e A2. A variável PEmax. aumentou somente na avaliação A2. CONCLUSÃO: A aplicação de protocolo de exercícios respiratórios com e sem carga adicional em indivíduos tabagistas produziu melhora imediata na performance dos músculos respiratórios, mas esta melhora foi mais acentuada após duas semanas de exercício.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o desempenho diagnóstico do índice de respiração rápida e superficial (IRRS) na predição do insucesso da extubação de pacientes adultos em terapia intensiva e verificar a adequação do valor de corte clássico para esse índice. MÉTODOS: Estudo prospectivo realizado na unidade de terapia intensiva de adultos do Hospital das Clínicas da Faculdade de Medicina de Botucatu, através da avaliação do IRRS em 73 pacientes consecutivos considerados clinicamente prontos para extubação. RESULTADOS: O IRRS com valor de corte clássico (105 ciclos/min/L) apresentou sensibilidade de 20% e especificidade de 95% (soma = 115%). A análise da curva receiver operator characteristic (ROC) demonstrou melhor valor de corte (76,5 ciclos/min/L), o qual forneceu sensibilidade de 66% e especificidade de 74% (soma = 140%), e a área sob a curva ROC para o IRRS foi de 0,78. CONCLUSÕES: O valor de corte clássico do IRRS se mostrou inadequado nesta casuística, prevendo apenas 20% dos pacientes com falha na extubação. A obtenção do novo valor de corte permitiu um acréscimo substancial de sensibilidade, com aceitável redução da especificidade. O valor da área sob a curva ROC indicou satisfatório poder discriminativo do índice, justificando a validação de sua aplicação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: estudar a validade da prova de trabalho de parto (PTP) em gestantes com uma cesárea anterior. Métodos: estudo retrospectivo, tipo coorte, incluindo 438 gestantes com uma cesárea anterior ao parto em estudo e seus 450 recém-nascidos (RN), divididas em dois grupos - com e sem PTP. O tamanho amostral mínimo foi de 121 gestantes/grupo. Considerou-se variável independente a PTP e as dependentes relacionaram-se à ocorrência de parto vaginal e à freqüência de complicações maternas e perinatais. Foram efetuadas análises uni e multivariada, respectivamente. A comparação entre as freqüências (%) foi analisada pelo teste do qui-quadrado (chi²) com significância de 5% e regressão logística com cálculo do odds ratio (OR) e do intervalo de confiança a 95% (IC95%). Resultados: a PTP associou-se a 59,2% de partos vaginais. Foi menos indicada nas gestantes com mais de 40 anos (2,7% vs 6,5%) e nas portadoras de doenças associadas e complicações da gravidez: síndromes hipertensivas (7,0%) e hemorragias de 3º trimestre (0,3%). A PTP não se relacionou às complicações maternas e perinatais. As gestantes que tiveram o parto por cesárea, independente da PTP, apresentaram maior risco de complicações puerperais (OR = 3,53; IC95% = 1,57-7,93). A taxa de mortalidade perinatal foi dependente do peso do RN e das malformações fetais e não se relacionou à PTP. Ao contrário, as complicações respiratórias foram mais freqüentes nos RN de mães não testadas quanto à PTP (OR = 1,92; IC95% = 1,20-3,07). Conclusões: os resultados comprovaram que a PTP em gestantes com uma cesárea anterior é estratégia segura - favoreceu o parto vaginal em 59,2% dos casos e não interferiu com a morbimortalidade materna e perinatal. Portanto, é recurso que deve ser estimulado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivos: avaliar a eficácia do acetato de medroxiprogesterona e do acetato de megestrol nas hiperplasias de endométrio. Métodos: foram incluídas, retrospectivamente 47 pacientes com sangramento uterino anormal, submetidas a curetagem uterina diagnóstica e/ou biópsia de endométrio, cujo achado histopatológico foi de hiperplasia de endométrio. Nas pacientes com hiperplasia sem atipia foi iniciado a terapêutica com acetato de medroxiprogesterona por via oral, na dose de 10 mg/dia durante 10-12 dias por mês. Nas com atipia, era utilizado o acetato de megestrol por via oral, dose de 160 mg/dia, uso contínuo. O período de tratamento variou de 3 a 18 meses. Biópsia de endométrio e/ou curetagem uterina de controle foram realizadas entre três e seis meses do início do tratamento e periodicamente para avaliar a resposta terapêutica. Resultados: foram analisadas 42 pacientes com hiperplasia endometrial sem atipia e cinco com atipia. A média de idade das pacientes foi de 49,5 ± 10,6 anos, sendo 70,2% com idade superior a 45 anos. O acetato de medroxiprogesterona foi eficaz em fazer regredir as hiperplasias sem atipias em 83,2% (35/42) e o acetato de megestrol em 80% (4/5) das hiperplasias com atipia. em 16,8% (7 casos) das hiperplasias sem atipia e em 20% (1 caso) das com atipia, ocorreu persistência das lesões, apesar do tratamento. em nenhum caso ocorreu progressão para câncer de endométrio, durante o período de seguimento que foi de 3 meses a 9 anos. No acompanhamento dessas pacientes, verificamos que 18 (38,3%) apresentaram amenorréia, em 12 (25,5%) ocorreu regularização do ciclo menstrual e 17 (36,2%) permaneceram com sangramento uterino anormal, sendo submetidas a histerectomia total abdominal. O exame anatomopatológico mostrou a persistência da lesão hiperplásica em oito casos, leiomioma em quatro, adenomiose em três, mio-hipertrofia uterina difusa em um caso e útero normal em outro, tendo havido regressão das lesões hiperplásicas nesses últimos nove casos. Conclusões: o tratamento das hiperplasias de endométrio com acetato de medroxiprogesterona e/ou acetato de megestrol, representa uma alternativa satisfatória para mulheres que desejam preservar o útero ou que tenham risco cirúrgico elevado. Entretanto, é necessário monitorização cuidadosa do endométrio, o que deve ser realizado pela avaliação dos sintomas, ultra-sonografia transvaginal e biópsia periódica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: traduzir e adaptar protocolo desenvolvido por pesquisadores alemães, adequando-o às características fonéticas e linguísticas do português falado no Brasil. Caracterizar os componentes de fala mais alterados na população com doença de Parkinson, comparando-os com grupo de sujeitos normais na mesma faixa etária. MÉTODOS: realizou-se a tradução e adaptação do protocolo. Posteriormente foram avaliados 21 pacientes com diagnóstico neurológico de Doença de Parkinson nos estágios Hoehn &Yarh, entre 2 e 3, e 10 sujeitos normais. O protocolo incluía avaliação da respiração, fonação, ressonância, articulação, prosódia e a análise acústica dos parâmetros vocais. RESULTADOS: o protocolo mostrou-se de fácil aplicação clínica. Nos sujeitos com doença de Parkinson foram observadas alterações predominantes na fonação (85,9%) e articulação (42,9%). CONCLUSÃO: o estudo demonstrou ser o protocolo uma ferramenta eficiente para a avaliação da disartria em pacientes com doença de Parkinson.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to perform voice evaluation in teachers with and without vocal symptoms, identifying etiologic factors of dysphonia, voice symptoms, vocal qualities, and laryngeal lesions. Eighty teachers were divided into two groups: GI (without or sporadic symptoms, 40) and GII (with frequent vocal symptoms, 40). They answered a specific questionnaire, and were subject to a perceptual vocal assessment (maximum phonation time, glottal attack, resonance, coordination of breathing and voicing, pitch, and loudness), GIRBAS scale, and to videolaryngoscopy. Females were predominant in both groups, and the age range was from 36 to 50 years. Elementary teachers predominated, working in classes with 31-40 students. Voice symptoms and alterations in the perceptual vocal analysis and in the GIRBAS scale were more frequent in GII In 46 teachers (GI-16; GII-30), videolaryngoscopy exams were abnormal with the vocal nodules being the most frequent lesions. These results indicate that a teacher's voice is compromised, and requires more attention including control of environmental factors and associated diseases, preventive vocal hygiene, periodic laryngeal examinations, and access to adequate specialist treatment.