984 resultados para PERSONNEL DOSIMETRY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Education for health is a process in which all public health and medical care personnel are involved. People learn both formally (planned learning experiences) and informally (unplanned learning experiences). Since the patient, the client, the consummer and the community expect public health and medical care personnel to assist them with health and disease issues and problems, the response of the professional "educates" the customer whether the professional intends to educate or not. Therefore, it is incumbent on all public health and medical care professionals to understand their educational functions and their role in health education. It is also important that the role of the specialist in education be clear. The specialist, as to all other specialists, has an in-depth knowledge of his area of expertise, i.e., the teaching/learning process; s/he may function as a consultant to others to enhance the educational potential of their role or s/he may work with a team or with communities or groups of patients. Specific competencies and knowledge are required of the health education specialist; and there is a body of learning and social change theory which provides a frame of reference for planning, implementing and evaluating educational programs. Working with others to enhance their potential to learn and to make informed decisions about health/disease issues is the hallmark of the health education specialist.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The exposure index (lgM) obtained from a radiographic image may be a useful feedback indicator to the radiographer about the appropriate exposure level in routine clinical practice. This study aims to evaluate lgM in orthopaedic radiography performed in the standard clinical environment. We analysed the lgM of 267 exposures performed with an AGFA CR system. The mean value of lgM in our sample is 2.14. A significant difference (P=0.000<0.05) from 1.96 lgM reference is shown. Data show that 72% of exposures are above the 1.96 lgM and 42% are above the limit of 2.26. Median values of lgM are above 1.96 and below 2.26 for Speed class (SC) 200 (2.16) and SC400 (2.13). The interquartile range is lower in SC400 than in SC200. Data seem to indicate that lgM values are above the manufacturer’s reference of 1.96. Departmental exposure charts should be optimised to reduce the dose given to patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Typical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in the Lisbon area and to compare the collected data with European references [Commission of European Communities (CEC) guidelines]. The results show that in four examinations (skull, chest, lumbar spine and pelvis), there is a strong tendency of using exposure times above the European recommendation. The X-ray tube potential values (in kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region), radiographic practice does not comply with CEC guidelines concerning exposure techniques. Further national/local studies are recommended with the objective to improve exposure optimisation and technical procedures in plain radiography. This study also suggests the need to establish national/local diagnostic reference levels and to proceed to effective measurements for exposure optimisation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Em Portugal não são conhecidos estudos publicados que identifiquem com clareza as distribuições típicas dos valores associados aos parâmetros técnicos de exposição utilizados nos exames radiológicos mais comuns. Este estudo tem como objectivos identificar os parâmetros técnicos utilizados em exames radiológicos convencionais na região de Lisboa e comparar os dados com a referência europeia CEC. Os resultados obtidos evidenciam que nas projecções estudadas existe uma predominância para o uso de termos de exposição acima da recomendação CEC e de valores de potencial da ampola (kV) abaixo da recomendação. Esta investigação sugere a necessidade de fixar os NRD nacionais, e/ou locais, e efectuar as respectivas medições, dado que a optimização da exposição é um mecanismo de controlo fundamental para limitar as exposições desnecessárias dos pacientes às radiações ionizantes. Conclui-se que a nível local (região da Grande Lisboa) existe um desconhecimento da prática radiológica enquadrada nos referenciais europeus de boa prática radiológica. Desconhecendo-se a situação a nível nacional, sugerem-se estudos no sentido de identificar os padrões de prática radiológica a nível do País e de promover a optimização dos procedimentos em radiologia convencional. ABSTRACT - Typical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in Lisbon area and to compare collected data with European references (CEC guidelines). Results show that in the four anatomic regions there is a strong tendency of using exposure times above the European recommendation. We also found that x-ray tube potential values (kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region) radiographic practice does not fit with CEC guidelines concerning exposure techniques. We suggest continuing national/local studies with the objective to improve exposure optimization and technical procedures in plain radiography. This study also suggests the need to establish national/local DRL’s and to proceed to effective measurements for exposure optimization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actualmente a Tomografia Computorizada (TC) é um dos métodos de diagnóstico por imagem que tem uma maior contribuição para a dose de radiação X recebida pelos pacientes. Pretende-se com este estudo avaliar as doses praticadas em TC e contribuir para o estabelecimento de Níveis de Referência de Diagnóstico (NRD) na região da Grande Lisboa, Portugal. Foram efectuadas medições de dose em 5 equipamentos de TC multidetectores, considerando o abdómen como área anatómica de interesse. Recorreu-se a uma câmara de ionização e a um fantoma para obter o índice de dose de TC (CTDI) e o produto dose-comprimento (DLP), que permitem determinar os NRD. Estes valores foram comparados com os NRD propostos pela Guideline Europeia e com os estudos desenvolvidos em outros países, como o Reino Unido, Grécia e Taiwan. Os resultados revelaram que os valores de NRD obtidos neste estudo (16,7 mGy para o CTDIvol e 436,5 mGy·cm para o DLP) são discrepantes relativamente à Guideline Europeia (±50%), mas muito próximos relativamente aos NRD estabelecidos nos países considerados. Estes valores podem ser eventualmente explicados pelos equipamentos em análise e pela utilização de protocolos de exame adoptados pelos profissionais de Radiologia nas instituições analisadas. ABSTRACT - Nowadays Computed Tomography (CT) is one of the imaging techniques which have a large contribution to radiation dose received by patients. The purpose of this study is to evaluate CT doses and contribute to the establishment of Diagnostic Reference Levels (DRL) in Lisbon, Portugal. Dose measurements on 5 multidetector CT scanners have been performed, considering the abdomen as the anatomic region of interest. All measurements were performed using an ionization chamber and a phantom to obtain the index CT dose (CTDI) and the dose-length product (DLP), which are used to determine DRL. These values were compared not only with European reference dose values but also with DRL studies developed in other countries like United Kingdom, Greece and Taiwan. The results revealed that DRL values obtained in this study (CTDIvol is 16,7 mGy and DLP is 436,5 mGy·cm) have a higher discrepancy to European Guideline (±50%), while the DRL´s of other countries are nearest to values obtained in this study. Those differences may be eventually explained by the type of the evaluated equipments but also by the exam protocols used by the Radiology professionals on the analyzed institutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The results of an evaluative longitudinal study, which identified the effects of health care decentralization on health financing in Mexico, Nicaragua and Peru are presented in this article. METHODS: The methodology had two main phases. In the first, secondary sources of data and documents were analyzed with the following variables: type of decentralization implemented, source of financing, funds for financing, providers, final use of resources, mechanisms for resource allocation. In the second phase, primary data were collected by a survey of key personnel in the health sector. RESULTS: Results of the comparative analysis are presented, showing the changes implemented in the three countries, as well as the strengths and weaknesses of each country in matters of financing and decentralization. CONCLUSIONS: The main financing changes implemented and quantitative trends with respect to the five financing indicators are presented as a methodological tool to implement corrections and adjustments in health financing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – A monitorização da exposição ocupacional a doses de radiação ionizante pode ser complementada por dosímetros eletrónicos individuais que permitem uma leitura direta da dose de radiação recebida. Dada a dependência energética e de débito de dose já reportada para estes dosímetros, este trabalho pretende determinar a linearidade da resposta de um dosímetro eletrónico individual e estudar o comportamento da sua resposta em função da energia de radiação e do débito de dose. Metodologia – Para estudar a dependência da energia da radiação do dosímetro eletrónico pessoal Vertec Bleeper Sv procedeu‑se à sua irradiação com um equivalente de dose individual, Hp(10), de 500 μSv de radiação gama do Cobalto – 60 (60C) e Césio – 137 (137Cs) e das qualidades de radiação X da série Narrow (N): N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. Para investigar a dependência da resposta em função do débito de dose aplicaram‑se à ampola de raios X as intensidades de corrente elétrica de 1 mA, 5 mA, 10 mA, 15 mA e 20 mA. Resultados – Não existe uma relação entre a resposta do detetor e a energia de radiação a que este é exposto. Ocorre uma subestimação superior a 50% na grandeza medida para energias inferiores a 33 keV, mas ostenta uma medida relativamente linear da grandeza Hp(10) para doses inferiores a 100 μSv. Também se constata que, à medida que o débito de dose aumenta, existe uma diminuição na resposta do dosímetro. O menor decréscimo na resposta deste dosímetro eletrónico individual dá‑se para as qualidades de radiação N‑30 (1,1%), N‑40 (4,1%) e N‑120 (20,0%). Conclusão – Verifica‑se que a resposta do dosímetro individual Vertec Bleeper Sv depende fortemente da energia da radiação e do débito de dose. ABSTRACT: Introduction – The measurement of occupational exposure to radiation doses can be completed with an electronic personal dosemeter that allows a direct reading and alarm function of the received radiation dose. Due to the energy and dose rate dependence already reported for this type of dosemeter, it is intended, with this work, to determine the response linearity of an Electronic Personal Dosemeter and to study its response behavior to the dose rate and radiation energy. Methodology – The electronic personal dosemeter Vertec Bleeper Sv energy dependency was evaluated by its irradiation with 500 μSv from the radionuclides Cobalt – 60 (60C) and Cesium – 137 (137Cs) as well as by the radiation qualities of the Narrow (N) series: N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. To investigate the dose rate dependency, the intensities of electric current of 1 mA, 5 mA, 10 mA, 15 mA and 20 mA were applied to the X‑ray tube. Results – There is no relationship between the response of the detector and the radiation energy. For energies below 33 keV there is an underestimation over 50% of the radiation dose measured but the detector presents a linear response for energies under 100 μSv. A dependency on the dose rate is perceived since as the dose rate increases, the response of the individual monitor decreases. There is a smaller decrease for the radiation qualities of N‑30 (1.1%), N‑40 (4.1%) and N‑120 (20.0%). Conclusion – It is concluded that there is a strong dependence of radiation energy and dose rate on the response of an electronic personal dosemeter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção Contra Radiações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção contra Radiações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: As in Brazil cancer registries are mostly based on large cities, there are no estimates per state or per region and information on the disease incidence in the vast in-land areas is very scarce. An incidence survey was conducted in 18 major cities of the state of São Paulo, excluding the capital, aiming to collect information about cancer incidence in the state of São Paulo. METHODS: Of the 18 cities in state of São Paulo included in the survey, all had available resources for cancer management. Data from the year of 1991 were collected by the personnel of the Instituto Brasileiro de Geografia e Estatística (Brazilian Institute of Statistics), who were especially trained by the study coordinators at the Fundação Oncocentro de São Paulo (Cancer Center of São Paulo). The collected data were processed and analyzed at the Oncocentro. Data collection, processing, and analyses were performed according to the recommendations of the International Agency for Research on Cancer. RESULTS: Although some discrepancies were observed in cancer incidence rates between the cities, results obtained for all 18 cities combined were remarkably close to those recently found for the city of São Paulo in the year 1993. One remarkable finding was the relatively high cancer incidence rates in both sexes in the city of Santos. CONCLUSIONS: The very similar all-sites cancer incidence rates found in the year 1991, when compared to those for the city of São Paulo in the year 1993, are suggestive that all regions have common cancer-related factors. Nevertheless, other explanations, such as the inclusion in the study of prevalent cases, as well as of non-residents, may have occurred in both studies, biasing the results. There is a need of further studies to confirm the high cancer incidence in Santos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nos últimos anos verificou-se uma alteração das condições e modo de funcionamento de empresas e instituições, privadas e públicas, muitas delas através da introdução de novas ferramentas de gestão. De entre elas, podemos destacar o outsourcing, que apesar de não ser um fenómeno actual, é ainda em Portugal uma ferramenta recente e pouco explorada, que pode contribuir de forma decisiva para a modernização, flexibilidade e competitividade das empresas. O presente estudo pretende abordar a contratação de serviços externos nos serviços de saúde públicos, também conhecido como outsourcing, mediante uma análise prática da realidade de uma instituição hospitalar com sete serviços em regime de outsourcing, com recolha dos dados durante o triénio 2008-2010. No Serviço de Urgência durante 2010 o principal prestador recebeu mais 104,28% acima do valor referência/hora, no Serviço de Oftalmologia no ano de 2010 o prestador recebeu um valor superior em 24,91%, no Serviço de Limpeza, Higiene e Conforto é pago ao prestador durante o ano de 2010 um valor superior em 13,85%, no Serviço de Vigilância e Segurança o prestador recebeu durante o ano de 2010 um valor superior em 27,5%, caso a instituição hospitalar optasse por contratar, para os serviços atrás referidos, profissionais para o quadro de pessoal. Ainda em relação ao Serviço de Urgência foi pago mais 21,38% acima do valor de referência publicado por Despacho governamental. Em relação aos Serviços de Lavandaria e de Tratamento de Resíduos Sólidos, não foi possível recolher os dados necessários que pudessem levar a uma conclusão válida sobre os custos pagos pela instituição hospitalar. Pode-se concluir que a contratação de prestadores externos, para os serviços de saúde, essenciais e não essenciais, em regime de outsourcing, revela-se na maioria dos casos analisados a opção menos económica, com custos bastantes elevados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada ao Instituto Superior de Contabilidade para obtenção do Grau de Mestre em Auditoria Orientada por: Doutora Alcina Dias