976 resultados para PERI-IMPLANT BONE


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabecular bone plays an important mechanical role in bone fractures and implant stability. Homogenized nonlinear finite element (FE) analysis of whole bones can deliver improved fracture risk and implant loosening assessment. Such simulations require the knowledge of mechanical properties such as an appropriate yield behavior and criterion for trabecular bone. Identification of a complete yield surface is extremely difficult experimentally but can be achieved in silico by using micro-FE analysis on cubical trabecular volume elements. Nevertheless, the influence of the boundary conditions (BCs), which are applied to such volume elements, on the obtained yield properties remains unknown. Therefore, this study compared homogenized yield properties along 17 load cases of 126 human femoral trabecular cubic specimens computed with classical kinematic uniform BCs (KUBCs) and a new set of mixed uniform BCs, namely periodicity-compatible mixed uniform BCs (PMUBCs). In stress space, PMUBCs lead to 7–72 % lower yield stresses compared to KUBCs. The yield surfaces obtained with both KUBCs and PMUBCs demonstrate a pressure-sensitive ellipsoidal shape. A volume fraction and fabric-based quadric yield function successfully fitted the yield surfaces of both BCs with a correlation coefficient R2≥0.93. As expected, yield strains show only a weak dependency on bone volume fraction and fabric. The role of the two BCs in homogenized FE analysis of whole bones will need to be investigated and validated with experimental results at the whole bone level in future studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. Accurate modeling is critical for orthopedic application to evaluate implant design and surgical planning. It has been shown that bone strength can be estimated from the bone mineral density (BMD) and trabecular bone architecture. However, these findings cannot be directly and fully transferred to patient-specific modeling since only BMD can be derived from clinical CT. Therefore, the objective of this study was to propose a method to predict the trabecular bone structure using a µCT atlas and an image registration technique. The approach has been evaluated on femurs and patellae under physiological loading. The displacement and ultimate force for femurs loaded in stance position were predicted with an error of 2.5% and 3.7%, respectively, while predictions obtained with an isotropic material resulted in errors of 7.3% and 6.9%. Similar results were obtained for the patella, where the strain predicted using the registration approach resulted in an improved mean squared error compared to the isotropic model. We conclude that the registration of anisotropic information from of a single template bone enables more accurate patient-specific simulations from clinical image datasets than isotropic model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The aim of this investigation was to evaluate the performance of Straumann Bone Level SLActive implants in various clinical situations in daily dental practice for up to 3 years. METHOD AND MATERIALS This was a prospective, multicenter, non-interventional study in which implants were placed within approved indications in any situation deemed suitable by the treating clinician. No implant placement or loading protocol was specified, and implants were placed according to the routine treatment protocols at each participating center. RESULTS In this analysis, data were available from 342 implants in 233 patients in three countries (USA, Canada, and Switzerland). One or two implants were placed in the majority of patients (70.8% and 19.3%, respectively), mostly in the maxilla (71.3%); almost half (47.7%) were placed in the esthetic zone. Implant placement after 4 to > 16 weeks of healing was preferred in Switzerland (92.0%), while 42.0% of implants were placed immediately in the USA and Canada. A flapless procedure was performed in 25.2% of cases in the USA and Canada, compared to 0.5% in Switzerland. Cumulative implant survival and success rates after 3 years were 97.5% and 93.5%, respectively. CONCLUSION Straumann Bone Level Implants can achieve favorable outcomes and high survival rates after 3 years in daily dental practice. The survival and success rates were comparable with those achieved in formal controlled clinical trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to analyze the patient pool referred to a specialty clinic for implant surgery over a 3-year period. MATERIALS AND METHODS All patients receiving dental implants between 2008 and 2010 at the Department of Oral Surgery and Stomatology were included in the study. As primary outcome parameters, the patients were analyzed according to the following criteria: age, sex, systemic diseases, and indication for therapy. For the inserted implants, the type of surgical procedure, the types of implants placed, postsurgical complications, and early failures were recorded. A logistic regression analysis was performed to identify possible local and systemic risk factors for complications. As a secondary outcome, data regarding demographics and surgical procedures were compared with the findings of a historic study group (2002 to 2004). RESULTS A total of 1,568 patients (792 women and 776 men; mean age, 52.6 years) received 2,279 implants. The most frequent indication was a single-tooth gap (52.8%). Augmentative procedures were performed in 60% of the cases. Tissue-level implants (72.1%) were more frequently used than bone-level implants (27.9%). Regarding dimensions of the implants, a diameter of 4.1 mm (59.7%) and a length of 10 mm (55.0%) were most often utilized. An early failure rate of 0.6% was recorded (13 implants). Patients were older and received more implants in the maxilla, and the complexity of surgical interventions had increased when compared to the patient pool of 2002 to 2004. CONCLUSION Implant therapy performed in a surgical specialty clinic utilizing strict patient selection and evidence-based surgical protocols showed a very low early failure rate of 0.6%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To analyze the indications and frequency for three-dimensional (3D) imaging for implant treatment planning in a pool of patients referred to a specialty clinic over a 3-year period. MATERIALS AND METHODS All patients who received dental implants between 2008 and 2010 at the Department of Oral Surgery and Stomatology at the University of Bern were included in the study. The influence of age, gender, and time of treatment (2008 to 2010) on the frequency of use of two-dimensional (2D) radiographic imaging modalities alone or in combination with 3D cone beam computed tomography (CBCT) scans was analyzed. Furthermore, the influence of the indication, location, and need for bone augmentation on the frequency of use of 2D imaging modalities alone or in combination with CBCT was evaluated. RESULTS In all, 1,568 patients (792 women and 776 men) received 2,279 implants. Overall, 633 patients (40.4%) were analyzed with 2D imaging procedures alone. CBCT was performed in 935 patients (59.6%). There was a statistically significant increase in CBCT between 2008 and 2010. Patients older than 55 years received a CBCT scan in addition to 2D radiographic imaging statistically significantly more often. Additional 3D imaging was most frequently performed in the posterior maxilla, whereas 2D radiographs alone exhibited the highest frequency in the anterior mandible. The combination of 2D with CBCT was used predominantly for implant placement with simultaneous or staged guided bone regeneration or sinus elevation. CONCLUSION Based on these findings from a specialty clinic, the use of additional CBCT imaging for implant treatment planning is influenced by the indication, location, local anatomy (including the need for bone augmentation), and the age of the patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Implant failures and postoperative complications are often associated to the bone drilling. Estimation and control of drilling parameters are critical to prevent mechanical damage to the bone tissues. For better performance of the drilling procedures, it is essential to understand the mechanical behaviour of bones that leads to their failures and consequently to improve the cutting conditions. This paper investigates the effect of drill speed and feed-rate on mechanical damage during drilling of solid rigid foam materials, with similar mechanical properties to the human bone. Experimental tests were conducted on biomechanical blocks instrumented with strain gauges to assess the drill speed and feed-rate influence. A three-dimensional dynamic finite element model to predict the bone stresses, as a function of drilling conditions, drill geometry and bone model, was developed. These simulations incorporate the dynamic characteristics involved in the drilling process. The element removal scheme is taken into account and allows advanced simulations of tool penetration and material removal. Experimental and numerical results show that generated stresses in the material tend to increase with tool penetration. Higher drill speed leads to an increase of von-Mises stresses and strains in the solid rigid foams. However, when the feed-rate is higher, the stresses and strains are lower. The numerical normal stresses and strains are found to be in good agreement with experimental results. The models could be an accurate analysis tool to simulate the stresses distribution in the bone during the drilling process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fixation failure of glenoid components is the main cause of unsuccessful total shoulder arthroplasties. The characteristics of these failures are still not well understood, hence, attempts at improving the implant fixation are somewhat blind and the failure rate remains high. This lack of understanding is largely due to the fundamental problem that direct observations of failure are impossible as the fixation is inherently embedded within the bone. Twenty custom made implants, reflecting various common fixation designs, and a specimen set-up was prepared to enable direct observation of failure when the specimens were exposed to cyclic superior loads during laboratory experiments. Finite element analyses of the laboratory tests were also carried out to explain the observed failure scenarios. All implants, irrespective of the particular fixation design, failed at the implant-cement interface and failure initiated at the inferior part of the component fixation. Finite element analyses indicated that this failure scenario was caused by a weak and brittle implant-cement interface and tensile stresses in the inferior region possibly worsened by a stress raiser effect at the inferior rim. The results of this study indicate that glenoid failure can be delayed or prevented by improving the implant/cement interface strength. Also any design features that reduce the geometrical stress raiser and the inferior tensile stresses in general should delay implant loosening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The generation of functional, vascularized tissues is a key challenge for the field of tissue engineering. Before clinical implantations of tissue engineered bone constructs can succeed, in vitro fabrication needs to address limitations in large-scale tissue development, including controlled osteogenesis and an inadequate vasculature network to prevent necrosis of large constructs. The tubular perfusion system (TPS) bioreactor is an effective culturing method to augment osteogenic differentiation and maintain viability of human mesenchymal stem cell (hMSC)-seeded scaffolds while they are developed in vitro. To further enhance this process, we developed a novel osteogenic growth factors delivery system for dynamically cultured hMSCs using microparticles encapsulated in three-dimensional alginate scaffolds. In light of this increased differentiation, we characterized the endogenous cytokine distribution throughout the TPS bioreactor. An advantageous effect in the ‘outlet’ portion of the uniaxial growth chamber was discovered due to the system’s downstream circulation and the unique modular aspect of the scaffolds. This unique trait allowed us to carefully tune the differentiation behavior of specific cell populations. We applied the knowledge gained from the growth profile of the TPS bioreactor to culture a high-volume bone composite in a 3D-printed femur mold. This resulted in a tissue engineered bone construct with a volume of 200cm3, a 20-fold increase over previously reported sizes. We demonstrated high viability of the cultured cells throughout the culture period as well as early signs of osteogenic differentiation. Taking one step closer toward a viable implant and minimize tissue necrosis after implantation, we designed a composite construct by coculturing endothelial cells (ECs) and differentiating hMSCs, encouraging prevascularization and anastomosis of the graft with the host vasculature. We discovered the necessity of cell to cell proximity between the two cell types as well as preference for the natural cell binding capabilities of hydrogels like collagen. Notably, the results suggested increased osteogenic and angiogenic potential of the encapsulated cells when dynamically cultured in the TPS bioreactor, suggesting a synergistic effect between coculture and applied shear stress. This work highlights the feasibility of fabricating a high-volume, prevascularized tissue engineered bone construct for the regeneration of a critical size defect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The use of artificial endoprostheses has become a routine procedure for knee and hip joints while ankle arthritis has traditionally been treated by means of arthrodesis. Due to its advantages, the implantation of endoprostheses is constantly increasing. While finite element analyses (FEA) of strain-adaptive bone remodelling have been carried out for the hip joint in previous studies, to our knowledge there are no investigations that have considered remodelling processes of the ankle joint. In order to evaluate and optimise new generation implants of the ankle joint, as well as to gain additional knowledge regarding the biomechanics, strain-adaptive bone remodelling has been calculated separately for the tibia and the talus after providing them with an implant. Methods: FE models of the bone-implant assembly for both the tibia and the talus have been developed. Bone characteristics such as the density distribution have been applied corresponding to CT scans. A force of 5,200 N, which corresponds to the compression force during normal walking of a person with a weight of 100 kg according to Stauffer et al., has been used in the simulation. The bone adaptation law, previously developed by our research team, has been used for the calculation of the remodelling processes. Results: A total bone mass loss of 2% in the tibia and 13% in the talus was calculated. The greater decline of density in the talus is due to its smaller size compared to the relatively large implant dimensions causing remodelling processes in the whole bone tissue. In the tibia, bone remodelling processes are only calculated in areas adjacent to the implant. Thus, a smaller bone mass loss than in the talus can be expected. There is a high agreement between the simulation results in the distal tibia and the literature regarding. Conclusions: In this study, strain-adaptive bone remodelling processes are simulated using the FE method. The results contribute to a better understanding of the biomechanical behaviour of the ankle joint and hence are useful for the optimisation of the implant geometry in the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de mestrado em Bioquímica, apresentada à Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa, 2016.