909 resultados para PEAK TORQUE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several brain imaging studies have assumed that response conflict is present in Stroop tasks. However, this has not been demonstrated directly. We examined the time-course of stimulus and response conflict resolution in a numerical Stroop task by combining single-trial electro-myography (EMG) and event-related brain potentials (ERP). EMG enabled the direct tracking of response conflict and the peak latency of the P300 ERP wave was used to index stimulus conflict. In correctly responded trials of the incongruent condition EMG detected robust incorrect response hand activation which appeared consistently in single trials. In 50–80% of the trials correct and incorrect response hand activation coincided temporally, while in 20–50% of the trials incorrect hand activation preceded correct hand activation. EMG data provides robust direct evidence for response conflict. However, congruency effects also appeared in the peak latency of the P300 wave which suggests that stimulus conflict also played a role in the Stroop paradigm. Findings are explained by the continuous flow model of information processing: Partially processed task-irrelevant stimulus information can result in stimulus conflict and can prepare incorrect response activity. A robust congruency effect appeared in the amplitude of incongruent vs. congruent ERPs between 330–400 ms, this effect may be related to the activity of the anterior cingulate cortex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper aims to present a preliminary benefit analysis for airborne GPS occultation technique for the Australian region. The simulation studies are based on current domestic commercial flights between major Australian airports. With the knowledge of GPS satellite ephemeris data, occultation events for for any particular flight can be determined. Preliminary analysis shows a high resolution occultation observations can be achieved with this approach, for instance, about 15 occultation events for a Perth-to-Sydney flight. The simulation result agrees to the results published by other researchers for a different region. Of course, occultation observation during off-peak hours might be affected due to the limited flight activities. --------- High resolution occultation observations obtainable from airborne GPS occultation system provides an opportunity to improve the current global numerical weather prediction (NWP) models and ultimately improves the accuracy in weather forecasting. More intensive research efforts and experimental demonstrations are required in order to demonstrate the technical feasibility of the airborne GPS technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes an automated procedure for analysing the significance of each of the many terms in the equations of motion for a serial-link robot manipulator. Significance analysis provides insight into the rigid-body dynamic effects that are significant locally or globally in the manipulator's state space. Deleting those terms that do not contribute significantly to the total joint torque can greatly reduce the computational burden for online control, and a Monte-Carlo style simulation is used to investigate the errors thus introduced. The procedures described are a hybrid of symbolic and numeric techniques, and can be readily implemented using standard computer algebra packages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Series Elasic Actuator has been proposed as a method for providing safe force or torque based acutation for robots that interact with humans. In this paper we look at some outstanding issues in the implementation and control of Series Elastic Actuators. The study addresses issues in making the Series Elastic Actuator respond effectively in the presence of physical difficulties such as restriction, using a computation efficient controller. The improvement over previous implementations is achieved by treating the motor as a velocity source to the elastic element, rather than as a torque source.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Velocity Sourced Series Elastic Actuator has been proposed as a method for providing safe force or torque based actuation for robots without compromising the actuator performance. In this paper we assess the safety of Velocity Sourced Series Elastic Actuators by measuring the Head Injury Criterion scores for collisions with a model head. The study makes a comparative analysis against stiff, high impedance actuation using the same motor without the series elastic component, showing that the series elastic component brings about a massive reduction in the chance of head injury. The benefits of a collision detection and safe reaction system are shown to be limited to collisions at low speeds, providing greater interaction comfort but not necessarily contributing to safety from injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Near-infrared (NIR) and Fourier transform infrared (FTIR) spectroscopy have been used to determine the mineralogical character of isomorphic substitutions for Mg2+ by divalent transition metals Fe, Mn, Co and Ni in natural halotrichite series. The minerals are characterised by d-d transitions in NIR region 12000-7500 cm-1. NIR spectrum of halotrichite reveals broad feature from 12000 to 7500 cm-1 with a splitting of two bands resulting from ferrous ion transition 5T2g ® 5Eg. The presence of overtones of OH- fundamentals near 7000 cm-1 confirms molecular water in the mineral structure of the halotrichite series. The appearance of the most intense peak at around 5132 cm-1 is a common feature in the three minerals and is derived from combination of OH- vibrations of water molecules and 2 water bending modes. The influence of cations like Mg2+, Fe2+, Mn2+, Co2+, Ni2+ shows on the spectra of halotrichites. Especially wupatkiite-OH stretching vibrations in which bands are distorted conspicuously to low wave numbers at 3270, 2904 and 2454 cm-1. The observation of high frequency 2 mode in the infrared spectrum at 1640 cm-1 indicates coordination of water molecules is strongly hydrogen bonded in natural halotrichites. The splittings of bands in 3 and 4 (SO4)2- stretching regions may be attributed to the reduction of symmetry from Td to C2v for sulphate ion. This work has shown the usefulness of NIR spectroscopy for the rapid identification and classification of the halotrichite minerals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The macerals in bituminous coals with varying organic sulfur content from the Early Permian Greta Coal Measures at three locations (Southland Colliery, Drayton Colliery and the Cranky Corner Basin), in and around the Sydney Basin (Australia), have been studied using light-element electron microprobe (EMP) analysis and micro-ATR–FTIR. Electron microprobe analysis of individual macerals reveals that the vitrinite in both the Cranky Corner Basin and Drayton Colliery (Puxtrees seam) samples have similar carbon contents (ca. 78% C in telocollinite), suggesting that they are of equivalent rank. However, the Cranky Corner coals have anomalously low vitrinite reflectance (down to 0.45%) vs. the Drayton materials (ca. 0.7%). They also have very high organic S content (3–6.5%) and lower O content (ca. 10%) than the equivalent macerals in the Drayton sample (0.7% S and 15.6% O). A study was carried out to investigate the impacts of the high organic S on the functional groups of the macerals in these two otherwise iso-rank, stratigraphically-equivalent seams. An iso-rank low-S coal from the overlying Wittingham Coal Measures near Muswellbrook and coals of slightly higher rank from the Greta Coal Measures at Southland Colliery near Cessnock were also evaluated using the same techniques to extend the data set. Although the telocollinite in the Drayton and Cranky Corner coals have very similar carbon content (ca.78% C), the ATR–FTIR spectra of the vitrinite and inertinite macerals in these respectively low S and high S coals show some distinct differences in IR absorbance from various aliphatic and aromatic functional groups. The differences in absorbance of the aliphatic stretching bands (2800–3000 cm−1) and the aromatic carbon (CC) peak at 1606 cm−1 are very obvious. Compared to that of the Drayton sample (0.7% S and 15% O), the telocollinite of the Cranky Corner coal (6% S and 10% O) clearly shows: (i) less absorbance from OH groups, represented by a broad region around 3553 cm−1, (ii) much stronger aliphatic C–H absorbance (stretching modes around 3000–2800 cm−1 and bending modes around 1442 cm−1) and (iii) less absorbance from aromatic carbon functional groups (peaking at 1606 cm−1). Evaluation of the iso-rank Drayton and Cranky Corner coals shows that: (i) the aliphatic C–H absorbances decrease with increasing oxygen content but increase with increasing organic S content and (ii) the aromatic H to aliphatic H ratio (Har/Hali) for the telocollinite increases with (organic) O%, but decreases progressively with increasing organic S. The high organic S content in the maceral appears to be accompanied by a greater proportion of aliphatic functional groups, possibly as a result of some of the O within maceral ring structures in the high S coal samples being replaced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When classifying a signal, ideally we want our classifier to trigger a large response when it encounters a positive example and have little to no response for all other examples. Unfortunately in practice this does not occur with responses fluctuating, often causing false alarms. There exists a myriad of reasons why this is the case, most notably not incorporating the dynamics of the signal into the classification. In facial expression recognition, this has been highlighted as one major research question. In this paper we present a novel technique which incorporates the dynamics of the signal which can produce a strong response when the peak expression is found and essentially suppresses all other responses as much as possible. We conducted preliminary experiments on the extended Cohn-Kanade (CK+) database which shows its benefits. The ability to automatically and accurately recognize facial expressions of drivers is highly relevant to the automobile. For example, the early recognition of “surprise” could indicate that an accident is about to occur; and various safeguards could immediately be deployed to avoid or minimize injury and damage. In this paper, we conducted initial experiments on the extended Cohn-Kanade (CK+) database which shows its benefits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water Sensitive Urban Design (WSUD) systems have the potential mitigate the hydrologic disturbance and water quality concerns associated with stormwater runoff from urban development. In the last few years WSUD has been strongly promoted in South East Queensland (SEQ) and new developments are now required to use WSUD systems to manage stormwater runoff. However, there has been limited field evaluation of WSUD systems in SEQ and consequently knowledge of their effectiveness in the field, under storm events, is limited. The objective of this research project was to assess the effectiveness of WSUD systems installed in a residential development, under real storm events. To achieve this objective, a constructed wetland, bioretention swale and a bioretention basin were evaluated for their ability to improve the hydrologic and water quality characteristics of stormwater runoff from urban development. The monitoring focused on storm events, with sophisticated event monitoring stations measuring the inflow and outflow from WSUD systems. Data analysis undertaken confirmed that the constructed wetland, bioretention basin and bioretention swale improved the hydrologic characteristics by reducing peak flow. The bioretention systems, particularly the bioretention basin also reduced the runoff volume and frequency of flow, meeting key objectives of current urban stormwater management. The pollutant loads were reduced by the WSUD systems to above or just below the regional guidelines, showing significant reductions to TSS (70-85%), TN (40-50%) and TP (50%). The load reduction of NOx and PO4 3- by the bioretention basin was poor (<20%), whilst the constructed wetland effectively reduced the load of these pollutants in the outflow by approximately 90%. The primary reason for the load reduction in the wetland was due to a reduction in concentration in the outflow, showing efficient treatment of stormwater by the system. In contrast, the concentration of key pollutants exiting the bioretention basin were higher than the inflow. However, as the volume of stormwater exiting the bioretention basin was significantly lower than the inflow, a load reduction was still achieved. Calibrated MUSIC modelling showed that the bioretention basin, and in particular, the constructed wetland were undersized, with 34% and 62% of stormwater bypassing the treatment zones in the devices. Over the long term, a large proportion of runoff would not receive treatment, considerably reducing the effectiveness of the WSUD systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background We have used serial visual analogue scores to demonstrate disturbances of the appetite profile in dialysis patients. This is potentially important as dialysis patients are prone to malnutrition yet have a lower nutrient intake than controls. Appetite disturbance may be influenced by accumulation of appetite inhibitors such as leptin and cholecystokinin (CCK) in dialysis patients. Methods Fasting blood samples were drawn from 43 controls, 50 haemodialysis (HD) and 39 peritoneal dialysis (PD) patients to measure leptin and CCK. Hunger and fullness scores were derived from profiles compiled using hourly visual analogue scores. Nutrient intake was derived from 3 day dietary records. Results Fasting CCK was elevated for PD (6.73 ± 4.42 ng/l vs control 4.99 ± 2.23 ng/l, P < 0.05; vs HD 4.43 ± 2.15 ng/l, P < 0.01). Fasting CCK correlated with the variability of the hunger (r = 0.426, P = 0.01) and fullness (r = 0.52, P = 0.002) scores for PD. There was a notable relationship with the increase in fullness after lunch for PD (r = 0.455, P = 0.006). When well nourished PD patients were compared with their malnourished counterparts, CCK was higher in the malnourished group (P = 0.004). Leptin levels were higher for the dialysis patients than controls (HD and PD, P < 0.001) with pronounced hyperleptinaemia evident in some PD patients. Control leptin levels demonstrated correlation with fullness scores (e.g. peak fullness, r = 0.45, P = 0.007) but the dialysis patients did not. PD nutrient intake (energy and protein intake, r = -0.56, P < 0.0001) demonstrated significant negative correlation with leptin. Conclusion Increased CCK levels appear to influence fullness and hunger perception in PD patients and thus may contribute to malnutrition. Leptin does not appear to affect perceived appetite in dialysis patients but it may influence nutrient intake in PD patients via central feeding centres.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Malnutrition is common among peritoneal dialysis (PD) patients. Reduced nutrient intake contributes to this. It has long been assumed that this reflects disturbed appetite. We set out to define the appetite profiles of a group of PD patients using a novel technique. DESIGN Prospective, cross-sectional comparison of PD patients versus controls. SETTING Teaching hospital dialysis unit. PATIENTS 39 PD patients and 42 healthy controls. INTERVENTION Visual analog ratings were recorded at hourly intervals to generate daily profiles for hunger and fullness. Summary statistics were generated to compare the groups. Food intake was measured using 3-day dietary records. MAIN OUTCOME MEASURES Hunger and fullness profiles. Derived hunger and fullness scores. RESULTS Controls demonstrated peaks of hunger before mealtimes, with fullness scores peaking after meals. The PD profiles had much reduced premeal hunger peaks. A postmeal reduction in hunger was evident, but the rest of the trace was flat. The PD fullness profile was also flatter than in the controls. Mean scores were similar despite the marked discrepancy in the profiles. The PD group had lower peak hunger and less diurnal variability in their hunger scores. They also demonstrated much less change in fullness rating around mealtimes, while the mean and peak fullness scores were little different. The reported nutrient intake was significantly lower for PD. CONCLUSION The data suggest that PD patients normalize their mean appetite perception at a lower level of nutrient intake than controls, suggesting that patient-reported appetite may be misleading in clinical practice. There is a loss of the usual daily variation for the PD group, which may contribute to their reduced food intake. The technique described here could be used to assess the impact of interventions upon the abnormal PD appetite profile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Power transformers are one of the most important and costly equipment in power generation, transmission and distribution systems. Current average age of transformers in Australia is around 25 years and there is a strong economical tendency to use them up to 50 years or more. As the transformers operate, they get degraded due to different loading and environmental operating stressed conditions. In today‘s competitive energy market with the penetration of distributed energy sources, the transformers are stressed more with minimum required maintenance. The modern asset management program tries to increase the usage life time of power transformers with prognostic techniques using condition indicators. In the case of oil filled transformers, condition monitoring methods based on dissolved gas analysis, polarization studies, partial discharge studies, frequency response analysis studies to check the mechanical integrity, IR heat monitoring and other vibration monitoring techniques are in use. In the current research program, studies have been initiated to identify the degradation of insulating materials by the electrical relaxation technique known as dielectrometry. Aging leads to main degradation products like moisture and other oxidized products due to fluctuating thermal and electrical loading. By applying repetitive low frequency high voltage sine wave perturbations in the range of 100 to 200 V peak across available terminals of power transformer, the conductive and polarization parameters of insulation aging are identified. An in-house novel digital instrument is developed to record the low leakage response of repetitive polarization currents in three terminals configuration. The technique is tested with known three transformers of rating 5 kVA or more. The effects of stressing polarization voltage level, polarizing wave shapes and various terminal configurations provide characteristic aging relaxation information. By using different analyses, sensitive parameters of aging are identified and it is presented in this thesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transport regulators consider that, with respect to pavement damage, heavy vehicles (HVs) are the riskiest vehicles on the road network. That HV suspension design contributes to road and bridge damage has been recognised for some decades. This thesis deals with some aspects of HV suspension characteristics, particularly (but not exclusively) air suspensions. This is in the areas of developing low-cost in-service heavy vehicle (HV) suspension testing, the effects of larger-than-industry-standard longitudinal air lines and the characteristics of on-board mass (OBM) systems for HVs. All these areas, whilst seemingly disparate, seek to inform the management of HVs, reduce of their impact on the network asset and/or provide a measurement mechanism for worn HV suspensions. A number of project management groups at the State and National level in Australia have been, and will be, presented with the results of the project that resulted in this thesis. This should serve to inform their activities applicable to this research. A number of HVs were tested for various characteristics. These tests were used to form a number of conclusions about HV suspension behaviours. Wheel forces from road test data were analysed. A “novel roughness” measure was developed and applied to the road test data to determine dynamic load sharing, amongst other research outcomes. Further, it was proposed that this approach could inform future development of pavement models incorporating roughness and peak wheel forces. Left/right variations in wheel forces and wheel force variations for different speeds were also presented. This led on to some conclusions regarding suspension and wheel force frequencies, their transmission to the pavement and repetitive wheel loads in the spatial domain. An improved method of determining dynamic load sharing was developed and presented. It used the correlation coefficient between two elements of a HV to determine dynamic load sharing. This was validated against a mature dynamic loadsharing metric, the dynamic load sharing coefficient (de Pont, 1997). This was the first time that the technique of measuring correlation between elements on a HV has been used for a test case vs. a control case for two different sized air lines. That dynamic load sharing was improved at the air springs was shown for the test case of the large longitudinal air lines. The statistically significant improvement in dynamic load sharing at the air springs from larger longitudinal air lines varied from approximately 30 percent to 80 percent. Dynamic load sharing at the wheels was improved only for low air line flow events for the test case of larger longitudinal air lines. Statistically significant improvements to some suspension metrics across the range of test speeds and “novel roughness” values were evident from the use of larger longitudinal air lines, but these were not uniform. Of note were improvements to suspension metrics involving peak dynamic forces ranging from below the error margin to approximately 24 percent. Abstract models of HV suspensions were developed from the results of some of the tests. Those models were used to propose further development of, and future directions of research into, further gains in HV dynamic load sharing. This was from alterations to currently available damping characteristics combined with implementation of large longitudinal air lines. In-service testing of HV suspensions was found to be possible within a documented range from below the error margin to an error of approximately 16 percent. These results were in comparison with either the manufacturer’s certified data or test results replicating the Australian standard for “road-friendly” HV suspensions, Vehicle Standards Bulletin 11. OBM accuracy testing and development of tamper evidence from OBM data were detailed for over 2000 individual data points across twelve test and control OBM systems from eight suppliers installed on eleven HVs. The results indicated that 95 percent of contemporary OBM systems available in Australia are accurate to +/- 500 kg. The total variation in OBM linearity, after three outliers in the data were removed, was 0.5 percent. A tamper indicator and other OBM metrics that could be used by jurisdictions to determine tamper events were developed and documented. That OBM systems could be used as one vector for in-service testing of HV suspensions was one of a number of synergies between the seemingly disparate streams of this project.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate estimation of input parameters is essential to ensure the accuracy and reliability of hydrologic and water quality modelling. Calibration is an approach to obtain accurate input parameters for comparing observed and simulated results. However, the calibration approach is limited as it is only applicable to catchments where monitoring data is available. Therefore, methodology to estimate appropriate model input parameters is critical, particularly for catchments where monitoring data is not available. In the research study discussed in the paper, pollutant build-up parameters derived from catchment field investigations and model calibration using MIKE URBAN are compared for three catchments in Southeast Queensland, Australia. Additionally, the sensitivity of MIKE URBAN input parameters was analysed. It was found that Reduction Factor is the most sensitive parameter for peak flow and total runoff volume estimation whilst Build-up rate is the most sensitive parameter for TSS load estimation. Consequently, these input parameters should be determined accurately in hydrologic and water quality simulations using MIKE URBAN. Furthermore, an empirical equation for Southeast Queensland, Australia for the conversion of build-up parameters derived from catchment field investigations as MIKE URBAN input build-up parameters was derived. This will provide guidance for allowing for regional variations in the estimation of input parameters for catchment modelling using MIKE URBAN where monitoring data is not available.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the meaning and understanding of domestic food preparation within the lived experience of the household's main food preparer this ethnographic study used a combination of qualitative and quantitative methodologies. Data were collected from three sources: the literature; an in-store survey of251 food shoppers chosen at random while shopping during both peak and off peak shopping periods at metropolitan supermarkets; and semi-structured interviews with the principal food shopper and food preparer of 15 different Brisbane households. Male and female respondents representing a cross section of socio-economic groupings, ranged in age from 19-79 years and were all from English speaking backgrounds. Changes in paid labour force participation, income and education have increased the value of the respondents' time, instigating massive changes in the way they shop, cook and eat. Much of their food preparation has moved from the domestic kitchen into the kitchens of other food establishments. For both sexes, the dominant motivating force behind these changes is a combination of the their self perceived lack of culinary skill; lack of enjoyment of cooking and lack of motivation to cook. The females in paid employment emphasise all factors, particularly the latter two, significantly more than the non-employed females. All factors are of increasing importance for individuals aged less than 35 years and conversely, of significantly diminished importance to older respondents. Overall, it is the respondents aged less than 25 years who indicate the lowest cooking frequency and/or least cooking ability. Inherent in this latter group is an indifference to the art/practice of preparing food. Increasingly, all respondents want to do less cooking and/or get the cooking over with as quickly as possible. Convenience is a powerful lure by which to spend less time in the kitchen. As well, there is an apparent willingness to pay a premium for convenience. Because children today are increasingly unlikely to be taught to cook, addressing the food skills deficit and encouraging individuals to cook for themselves are significant issues confronting health educators. These issues are suggested as appropriate subjects of future research.