921 resultados para PCR fluorescente
Resumo:
Use of PCR in the field of molecular diagnostics has increased to the point where it is now accepted as the standard method for detecting nucleic acids from a number of sample and microbial types. However, conventional PCR was already an essential tool in the research laboratory. Real-time PCR has catalysed wider acceptance of PCR because it is more rapid, sensitive and reproducible, while the risk of carryover contamination is minimised. There is an increasing number of chemistries which are used to detect PCR products as they accumulate within a closed reaction vessel during real-time PCR. These include the non-specific DNA-binding fluorophores and the specific, fluorophore-labelled oligonucleotide probes, some of which will be discussed in detail. It is not only the technology that has changed with the introduction of real-time PCR. Accompanying changes have occurred in the traditional terminology of PCR, and these changes will be highlighted as they occur. Factors that have restricted the development of multiplex real-time PCR, as well as the role of real-time PCR in the quantitation and genotyping of the microbial causes of infectious disease, will also be discussed. Because the amplification hardware and the fluorogenic detection chemistries have evolved rapidly, this review aims to update the scientist on the current state of the art. Additionally, the advantages, limitations and general background of real-time PCR technology will be reviewed in the context of the microbiology laboratory.
Resumo:
Today, quantitative real-time PCR is the method of choice for rapid and reliable quantification of mRNA transcription. However, for an exact comparison of mRNA transcription in different samples or tissues it is crucial to choose the appropriate reference gene. Recently glyceraldehyde 3-phosphate dehydrogenase and P-actin have been used for that purpose. However, it has been reported that these genes as well as alternatives, like rRNA genes, are unsuitable references, because their transcription is significantly regulated in various experimental settings and variable in different tissues. Therefore, quantitative real-time PCR was used to determine the mRNA transcription profiles of 13 putative reference genes, comparing their transcription in 16 different tissues and in CCRF-HSB-2 cells stimulated with 12-O-tetradecanoylphorbol-13-acetate and ionomycin. Our results show that Classical reference genes are indeed unsuitable, whereas the RNA polymerase II gene was the gene with the most constant expression in different tissues and following stimulation in CCRF-HSB-2 cells. (C) 2003 Elsevier Inc. All rights reserved.
Resumo:
Human polyomaviruses JCV and BKV can cause several clinical manifestations in immunocompromised hosts, including progressive multifocal leukoencephalopathy (PML) and haemorrhagic cystitis. Molecular detection by polymerase chain reaction (PCR) is recognised as a sensitive and specific method for detecting human polyomaviruses in clinical samples. In this study, we developed a PCR assay using a single primer pair to amplify a segment of the VP1 gene of JCV and BKV. An enzyme linked amplicon hybridisation assay (ELAHA) using species-specific biotinylated oligonucleotide probes was used to differentiate between JCV and BKV. This assay (VP1-PCR-ELAHA) was evaluated and compared to a PCR assay targeting the human polyomavirus T antigen gene (pol-PCR). DNA sequencing was used to confirm the polyomavirus species identified by the VP1-PCR-ELAHA and to determine the subtype of each JCV isolate. A total of 297 urine specimens were tested and human polyomavirus was detected in 105 specimens (35.4%) by both PCR assays. The differentiation of JCV and BKV by the VP1-PCR-ELAHA showed good agreement with the results of DNA sequencing. Further, DNA sequencing of the JCV positive specimens showed the most prevalent JCV subtype in our cohort was 2a (27%) followed by 1b (20%), 1a (15%), 2c (14%), 4 (14%) and 2b (10%). The results of this study show that the VP1-PCR-ELAHA is a sensitive, specific and rapid method for detecting and differentiating human polyomaviruses JC and BK and is highly suitable for routine use in the clinical laboratory. (C) 2004 Wiley-Liss, Inc.
Resumo:
Aim: The aim of this study was to assess the discriminatory power and potential turn around time ( TAT) of a PCR-based method for the detection of methicillin-resistant Staphylococcus aureus (MRSA) from screening swabs. Methods: Screening swabs were examined using the current laboratory protocol of direct culture on mannitol salt agar supplemented with oxacillin (MSAO-direct). The PCR method involved pre-incubation in broth for 4 hours followed by a multiplex PCR with primers directed to mecA and nuc genes of MRSA. The reference standard was determined by pre-incubation in broth for 4 hours followed by culture on MSAO (MSAO-broth). Results: A total of 256 swabs was analysed. The rates of detection of MRSA using MSAO-direct, MSAO-broth and PCR were 10.2, 13.3 and 10.2%, respectively. For PCR, the sensitivity, specificity, positive predictive value and negative predictive values were 66.7% (95% CI 51.9 - 83.3%), 98.6% ( 95% CI 97.1 - 100%), 84.6% ( 95% CI 76.2 - 100%) and 95.2% ( 95% CI 92.4 - 98.0%), respectively, and these results were almost identical to those obtained from MSAO-direct. The agreement between MSAO-direct and PCR was 61.5% ( 95% CI 42.8 - 80.2%) for positive results, 95.6% ( 95% CI 93.0 - 98.2%) for negative results and overall was 92.2% ( 95% CI 88.9 - 95.5%). Conclusions: ( 1) The discriminatory power of PCR and MSAO-direct is similar but the level of agreement, especially for true positive results, is low. ( 2) The potential TAT for the PCR method provides a marked advantage over conventional methods. ( 3) Further modifications to the PCR method such as increased broth incubation time, use of selective broth and adaptation to real-time PCR may lead to improvement in sensitivity and TAT.
Resumo:
Pentobarbitone sodium (Sodium 5-ethyl-5[1-methylbutyl]-pentobarbitone) is a short-acting barbiturate that is commonly used to euthanase animals. As part of our studies into the molecular genetics of copper toxicosis in Bedlington terrier dogs, reverse-transcription (RT)-PCR was noted to always fail on RNA samples collected from livers of dogs sacrificed by pentobarbitone injection. When samples were collected without pentobarbitone, however, RTPCR was always successful. We suspected the possible inhibition by pentobarbitone sodium of either reverse transcriptase or Taq polymerase. In vitro studies showed that pentobarbitone interference of PCR occurred at >4 mug/mul. To identify if pentobarbitone produced competitive inhibition, each components (Taq polymerase, MgCl2, dNTP, etc.) of the PCR was individually altered. However, inhibition still persisted, suggesting that multiple PCR components may be affected. Also it was shown that pentobarbitone interference was not dependent on the PCR product size. Simple dilution of pentobarbitone contaminated DNA solutions, and the addition of bovine serum albumin (BSA) to the PCR mix overcame pentobarbitone interference. In vivo, PCR by pentobarbitone was found to be compounded by high DNA concentration and pentobarbitone contamination. In addition, both high DNA concentration and pentobarbitone contamination could be overcome through dilution and the addition of BSA. Further work is required to quantify pentobarbitone concentration in the liver-extracted DNA and RNA samples before this inhibition effect on PCR can be fully elucidated. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
In this study, the suitability of two repetitive-element-based PCR (rep-PCR) assays, enterobacterial repetitive intergenic consensus (ERIC)-PCR and BOX-PCR, to rapidly characterize Pseudomonas aeruginosa strains isolated from patients with cystic fibrosis (CF) was examined. ERIC-PCR utilizes paired sequence-specific primers and BOX-PCR a single primer that target highly conserved repetitive elements in the P. aeruginosa genome. Using these rep-PCR assays, 163 P. aeruginosa isolates cultured from sputa collected from 50 patients attending an adult CF clinic and 50 children attending a paediatric CF clinic were typed. The results of the rep-PCR assays were compared to the results of PFGE. All three assays revealed the presence of six major clonal groups shared by multiple patients attending either of the CF clinics, with the dominant clonal group infecting 38% of all patients. This dominant clonal group was not related to the dominant clonal group detected in Sydney or Melbourne (pulsotype 1), nor was it related to the dominant groups detected in the UK. In all, PFGE and rep-PCR identified 58 distinct clonal groups, with only three of these shared between the two clinics. The results of this study showed that both ERIC-PCR and BOX-PCR are rapid, highly discriminatory and reproducible assays that proved to be powerful surveillance screening tools for the typing of clinical P. aeruginosa isolates recovered from patients with CF.
Resumo:
The Roche Cobas Amplicor system is widely used for the detection of Neisseria gonorrhoeae but is known to cross react with some commensal Neisseria spp. Therefore, a confirmatory test is required. The most common target for confirmatory tests is the cppB gene of N. gonorrhoeae. However, the cppB gene is also present in other Neisseria spp. and is absent in some N. gonorrhoeae isolates. As a result, laboratories targeting this gene run the risk of obtaining both false-positive and false-negative results. In the study presented here, a newly developed N. gonorrhoeae LightCycler assay (NGpapLC) targeting the N. gonorrhoeae porA pseudogene was tested. The NGpapLC assay was used to test 282 clinical samples, and the results were compared to those obtained using a testing algorithm combining the Cobas Amplicor System (Roche Diagnostics, Sydney, Australia) and an in-house LightCycler assay targeting the cppB gene (cppB-LC). In addition, the specificity of the NGpapLC assay was investigated by testing a broad panel of bacteria including isolates of several Neisseria spp. The NGpapLC assay proved to have comparable clinical sensitivity to the cppB-LC assay. In addition; testing of the bacterial panel showed the NGpapLC assay to be highly specific for N. gonorrhoeae DNA. The results of this study show the NGpapLC assay is a suitable alternative to the cppB-LC assay for confirmation of N. gonorrhoeae-positive results obtained with Cobas Amplicor.
Resumo:
The dwarf somaclonal variant is a major problem affecting micropropagation of the banana cultivar Williams (Musa spp. AAA; subgroup Cavendish). This problem arises from genetic changes that occur during the tissue culture process. Early identification of this problem is difficult and propagators must wait until plants are ex vitro in order to visualise the dwarfism phenotype. In this study, we have improved a SCAR-based molecular diagnostic technique, developed by Damasco et al. [Acta Hortic. 461 (1997) 157], for the early identification of dwarf off-types. We have included a positive internal control in a multiplex PCR and adapted the technique for use with small amounts of fresh in vitro leaf material as PCR template. The control product is a 500 bp fragment from 18S rRNA and is amplified in all tissues irrespective of phenotype. The use of small in vitro leaf material removing the need for genomic DNA extraction. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Bacterial artificial chromosome (BAC) libraries have been widely used in different aspects of genome research. In this paper we report the construction of the first mungbean (Vigna radiata L. Wilczek) BAC libraries. These BAC clones were obtained from two ligations and represent an estimated 3.5 genome equivalents. This correlated well with the screening of nine random single-copy restriction fragment length polymorphism probes, which detected on average three BACs each. These mungbean clones were successfully used in the development of two PCR-based markers linked closely with a major locus conditioning bruchid (Callosobruchus chinesis) resistance. These markers will be invaluable in facilitating the introgression of bruchid resistance into breeding programmes as well as the further characterisation of the resistance locus.
Resumo:
This study was designed to assess the effect of sequence mismatches between primers and their targets on viral quantitative PCR. Numerous primers were constructed incorporating various mismatches with a target sequence on the BKV T antigen gene. When using these primers in standard Taqman two-step cycling conditions, as few as two mismatches in a single primer increased cycle threshold values and significantly influenced the calculation of viral load. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
The potential for large-scale use of a sensitive real time reverse transcription polymerase chain reaction (RT-PCR) assay was evaluated for the detection of Tomato spotted wilt virus (TSWV) in single and bulked leaf samples by comparing its sensitivity with that of DAS-ELISA. Using total RNA extracted with RNeasy (R) or leaf soak methods, real time RT-PCR detected TSWV in all infected samples collected from 16 horticultural crop species (including flowers, herbs and vegetables), two arable crop species, and four weed species by both assays. In samples in which DAS-ELISA had previously detected TSWV, real time RT-PCR was effective at detecting it in leaf tissues of all 22 plant species tested at a wide range of concentrations. Bulk samples required more robust and extensive extraction methods with real time RT-PCR, but it generally detected one infected sample in 1000 uninfected ones. By contrast, ELISA was less sensitive when used to test bulked samples, once detecting up to I infected in 800 samples with pepper but never detecting more than I infected in 200 samples in tomato and lettuce. It was also less reliable than real time RT-PCR when used to test samples from parts of the leaf where the virus concentration was low. The genetic variability among Australian isolates of TSWV was small. Direct sequencing of a 587 bp region of the nucleoprotein gene (S RNA) of 29 isolates from diverse crops and geographical locations yielded a maximum of only 4.3% nucleotide sequence difference. Phylogenetic analysis revealed no obvious groupings of isolates according to geographic origin or host species. TSWV isolates, that break TSWV resistance genes in tomato or pepper did not differ significantly in the N gene region studied, indicating that a different region of the virus genome is responsible for this trait.