976 resultados para Orthodontic mini-implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In normal aging, the decrease in the syntactic complexity of written production is usually associated with cognitive deficits. This study was aimed to analyze the quality of older adults' textual production indicated by verbal fluency (number of words) and grammatical complexity (number of ideas) in relation to gender, age, schooling, and cognitive status. Methods: From a probabilistic sample of community-dwelling people aged 65 years and above (n = 900), 577 were selected on basis of their responses to the Mini-Mental State Examination (MMSE) sentence writing, which were submitted to content analysis; 323 were excluded as they left the item blank or performed illegible or not meaningful responses. Education adjusted cut-off scores for the MMSE were used to classify the participants as cognitively impaired or unimpaired. Total and subdomain MMSE scores were computed. Results: 40.56% of participants whose answers to the MMSE sentence were excluded from the analyses had cognitive impairment compared to 13.86% among those whose answers were included. The excluded participants were older and less educated. Women and those older than 80 years had the lowest scores in the MMSE. There was no statistically significant relationship between gender, age, schooling, and textual performance. There was a modest but significant correlation between number of words written and the scores in the Language subdomain. Conclusions: Results suggest the strong influence of schooling and age over MMSE sentence performance. Failing to write a sentence may suggest cognitive impairment, yet, instructions for the MMSE sentence, i.e. to produce a simple sentence, may limit its clinical interpretation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of chronic inflammatory periodontal disease due to dental plaque in adults over 30 years of age was noticed in 47.2% of the 3,742 subjects studied, representing a 64.7 million people population in the 50 states of the U.S. and the District of Columbia. The methods used by the authors were uniquely precise and the results brought us to great insight on the correlation between orthodontic treatment and periodontal health, which is described below.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From a recent perspective the morse-taper dental implants connections are increasingly being used as an alternative for replacement of a missing teeth. Nevertheless, there are a large variety of prosthetic components available on the market with some limitations regarding the final prothesis. This article demonstrated the difficulties and limitations of prosthesis implant-retained connections when using morse-taper implants (with a prosthetic index) case in which the surgical placement of the implant wasn’t successfully performed. The alternative to overcome this scenario was the technique using the tube screw over the top of a mini abutment component. It was possible to manufacture and to have satisfactory adaptation, achieving the satisfaction of the patient, restoring function and esthetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In recent years, the benefits associated with the use of cochlear implants (CIs), especially with regard to speech perception, have proven to surpass those produced by the use of hearing aids, making CIs a highly efficient resource for patients with severe/profound hearing loss. However, few studies so far have assessed the satisfaction of adult users of CIs. Objective: To analyze the relationship between the level of speech perception and degree of satisfaction of adult users of CI. Method: This was a prospective cross-sectional study conducted in the Audiological Research Center (CPA) of the Hospital of Craniofacial Anomalies, University of São Paulo (HRAC/USP), in Bauru, São Paulo, Brazil. A total of 12 users of CIs with pre-lingual or post-lingual hearing loss participated in this study. The following tools were used in the assessment: a questionnaire, "Satisfaction with Amplification in Daily Life" (SADL), culturally adapted to Brazilian Portuguese, as well as its relationship with the speech perception results; a speech perception test under quiet conditions; and the Hearing in Noise Test (HINT)Brazil under free field conditions. Results: The participants in the study were on the whole satisfied with their devices, and the degree of satisfaction correlated positively with the ability to perceive monosyllabic words under quiet conditions. The satisfaction did not correlate with the level of speech perception in noisy environments. Conclusion: Assessments of satisfaction may help professionals to predict what other factors, in addition to speech perception, may contribute to the satisfaction of CI users in order to reorganize the intervention process to improve the users' quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to compare the dentoskeletal changes of patients with Class II Division 1 malocclusion treated with either the Jasper jumper appliance or the activator-headgear combination, both associated with fixed appliances. Methods: The sample comprised 72 subjects with Class II Division 1 malocclusion divided into 3 groups: group 1 included 25 subjects treated with fixed appliances and the force modules of the Jasper jumper at an initial mean age of 12.72 years, group 2 included 25 subjects treated with the activator-headgear combination followed by fixed appliances at an initial mean age of 11.07 years, and group 3 included 22 untreated subjects at an initial mean age of 12.67 years. Initial cephalometric characteristics and dentoskeletal changes were compared with analysis of variance. Results: Both experimental groups had similar dentoskeletal changes: restrictive effect on the maxilla, clockwise mandibular rotation and a slight increase in anterior face height, retrusion of the maxillary incisors, distalization of the maxillary molars, protrusion of the mandibular incisors, extrusion of the mandibular molars, and significant improvements of the maxillomandibular relationship, overjet, overbite, and the molar relationship. Conclusions: The effects of the Jasper jumper and the activator-headgear combination followed by fixed orthodontic appliances were similar in Class II malocclusion treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone remodeling is affected by mechanical loading and inflammatory mediators, including chemokines. The chemokine (C–C motif) ligand 3 (CCL3) is involved in bone remodeling by binding to C–C chemokine receptors 1 and 5 (CCR1 and CCR5) expressed on osteoclasts and osteoblasts. Our group has previously demonstrated that CCR5 down-regulates mechanical loading-induced bone resorption. Thus, the present study aimed to investigate the role of CCR1 and CCL3 in bone remodeling induced by mechanical loading during orthodontic tooth movement in mice. Our results showed that bone remodeling was significantly decreased in CCL3−/− and CCR1−/− mice and in animals treated with Met-RANTES (an antagonist of CCR5 and CCR1). mRNA levels of receptor activator of nuclear factor kappa-B (RANK), its ligand RANKL, tumor necrosis factor alpha (TNF-α) and RANKL/osteoprotegerin (OPG) ratio were diminished in the periodontium of CCL3−/− mice and in the group treated with Met-RANTES. Met-RANTES treatment also reduced the levels of cathepsin K and metalloproteinase 13 (MMP13). The expression of the osteoblast markers runt-related transcription factor 2 (RUNX2) and periostin was decreased, while osteocalcin (OCN) was augmented in CCL3−/− and Met-RANTES-treated mice. Altogether, these findings show that CCR1 is pivotal for bone remodeling induced by mechanical loading during orthodontic tooth movement and these actions depend, at least in part, on CCL3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the aesthetics of an implant-supported denture at the cleft area, comparing the peri-implant tissues and prosthetic crown with the contralateral tooth. Settings: Hospital for Rehabilitation of Craniofacial Anomalies, Bauru, São Paolo, Brazil. Patients: A total of 39 individuals of both genders, with complete unilateral cleft lip and palate, who received secondary alveolar bone graft and were rehabilitated with single implant-supported dentures at the area of the missing maxillary lateral incisor after completion of orthodontic treatment. Interventions: The following parameters were analyzed in follow-up sessions: length and width of prosthetic crown and contralateral tooth, characteristics of implants, filling of interproximal space by the papilla, and smile height of the patients. Results: The implant-supported prosthetic crowns were longer than the contralateral tooth (p < .001). Among the 78 papillae analyzed, 29 (37.17%) received a score of 3; 32 (41.02%) papillae had a score of 2; and 17 (21.79%) received a score of 1. Concerning the smile height, among the 39 patients analyzed, 23 (56.41%) had a medium smile, 15 (38.46%) had a high smile, and two (5.12%) presented a low smile. Conclusion: The use of dental implants to rehabilitate the edentulous cleft area is an excellent option. However, adequate evaluation of the bone quantity and quality, positioning and shape of adjacent teeth, smile height, and patient expectations should be considered to achieve success and avoid aesthetic deformities such as elongated teeth and absence of gingival papillae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The watermelon is traditionally cultivated horizontally on the ground. The cultivars of small fruits (1 to 3 kg), which reach better market prices, are also being grown in a greenhouse, where the plants are trained upward on vertical supports, with branches pruning and fruits thinning. These practices make possible an increase of the plant density, fruit quality and yield compared to the traditional growth system. The aim of this experiment was to evaluate the influence of three training heights (1.7, 2.2 and 2.7 m) and two planting densities (3.17 and 4.76 plants m-2) over the productive and qualitative characteristics of mini watermelon "Smile" cultivated in greenhouse. The pruning was done at 43, 55 and 66 days after transplanting (DAT), when the plant height reached 1.7, 2.2 and 2.7 m, respectively. The dry mass of branches, petioles, leaves and total were affected by the training height, where the highest values were obtained by the plants pruned at 2.2 and 2.7 m. Leaf area, specific leaf area and leaf area index were not affected by the height of the plants. The training height of 2.7 m raised the total yield, however, marketable yield, average fruit mass and all the quality characteristics did not differ significantly from those obtained by the training height of 2.2 m. Regarding to plant density, the best option was 4.76 plants m-2, due to the increasing of marketable yield in 37.4% without reducing the average weight of fruits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate in vivo the failure rate of metallic brackets bonded with two orthodontic composites. Nineteen patients with ages ranging from 10.5 to 38.7 years needing corrective orthodontic treatment were selected for study. The enamel surfaces from second premolars to second premolars were treated with Transbond Plus-Self Etching Primer (3M Unitek). Next, 380 orthodontic brackets were bonded on maxillary and mandibular teeth, as follows: 190 with Transbond XT composite (3M Unitek) (control) and 190 with Transbond Plus Color Change (3M Unitek) (experimental) in contralateral quadrants. The bonded brackets were light cured for 40 s, and initial alignment archwires were inserted. Bond failure rates were recorded over a six-month period. At the end of the evaluation, six bond failures occurred, three for each composite. Kaplan-Meyer method and log-rank test (Mantel-Cox) was used for statistical analysis, and no statistically significant difference was found between the materials (p=0.999). Both Transbond XT and Transbond Plus Color Change composites had low debonding rates over the study period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To explore the biomechanical effects of the different implantation bone levels of Morse taper implants, employing a finite element analysis (FEA). METHODS: Dental implants (TitamaxCM) with 4x13 mm and 4x11 mm, and their respective abutments with 3.5 mm height, simulating a screwed premolar metal-ceramic crown, had their design performed using the software AnsysWorkbench 10.0. They were positioned in bone blocks, covered by 2.5 mm thickness of mucosa. The cortical bone was designed with 1.5 mm thickness and the trabecular bone completed the bone block. Four groups were formed: group 11CBL (11 mm implant length on cortical bone level), group 11TBL (11 mm implant length on trabecular bone level), group 13CBL (13mm implant length on cortical bone level) and group 13TBL (13 mm implant length on trabecular bone level). Oblique 200 N loads were applied. Von Mises equivalent stresses in cortical and trabecular bones were evaluated with the same design program. RESULTS: The results were shown qualitatively and quantitatively by standard scales for each type of bone. By the results obtained, it can be suggested that positioning the implant completely in trabecular bone brings harm with respect to the generated stresses. Its implantation in the cortical bone has advantages with respect to better anchoring and locking, reflecting a better dissipation of the stresses along the implant/bone interfaces. In addition, the search for anchoring the implant in its apical region in cortical bone is of great value to improve stabilization and consequently better stress distribution. CONCLUSIONS: The implant position slightly below the bone in relation to the bone crest brings advantages as the best long-term predictability with respect to the expected neck bone loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information about orthodontic movement of teeth with hypercementosis is scarce. As cementum deposition continues to occur, cementum is expected to change the shape of the root and apex over time, but this has not yet been demonstrated. Nor has it ever been established whether it increases or decreases the prevalence of root resorption during orthodontic treatment. The unique biological function of the interconnected network of cementocytes may play a role in orthodontic movement and its associated root resorptions, but no research has ever been conducted on the topic. Unlike cementum thickness and hypercementosis, root and apex shape has not yet been related to patient age. A study of the precise difference between increased cementum thickness and hypercementosis is warranted. Hypercementosis refers to excessive cementum formation above and beyond the extent necessary to fulfill its normal functions, resulting in abnormal thickening with macroscopic changes in the tooth root, which may require the delivery of forces that are different from conventional mechanics in their intensity, direction and distribution. What are the unique features and specificities involved in moving teeth that present with hypercementosis? Bodily movements would be expected to occur, since inclination might prove difficult to achieve, but would the root resorption index be higher or lower?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Define and compare numbers and types of occlusal contacts in maximum intercuspation. METHODS: The study consisted of clinical and photographic analysis of occlusal contacts in maximum intercuspation. Twenty-six Caucasian Brazilian subjects were selected before orthodontic treatment, 20 males and 6 females, with ages ranging between 12 and 18 years. The subjects were diagnosed and grouped as follows: 13 with Angle Class I malocclusion and 13 with Angle Class II Division 1 malocclusion. After analysis, the occlusal contacts were classified according to the established criteria as: tripodism, bipodism, monopodism (respectively, three, two or one contact point with the slope of the fossa); cuspid to a marginal ridge; cuspid to two marginal ridges; cuspid tip to opposite inclined plane; surface to surface; and edge to edge. RESULTS: The mean number of occlusal contacts per subject in Class I malocclusion was 43.38 and for Class II Division 1 malocclusion it was 44.38, this difference was not statistically significant (p>0.05). CONCLUSIONS: There is a variety of factors that influence the number of occlusal contacts between a Class I and a Class II, Division 1 malocclusion. There is no standardization of occlusal contact type according to the studied malocclusions. A proper selection of occlusal contact types such as cuspid to fossa or cuspid to marginal ridge and its location in the teeth should be individually defined according to the demands of each case. The existence of an adequate occlusal contact leads to a correct distribution of forces, promoting periodontal health.