This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
Studies on the assessment of heart rate variability threshold (HRVT) during walking are scarce. We determined the reliability and validity of HRVT assessment during the incremental shuttle walk test (ISWT) in healthy subjects. Thirty-one participants aged 57 ± 9 years (17 females) performed 3 ISWTs. During the 1st and 2nd ISWTs, instantaneous heart rate variability was calculated every 30 s and HRVT was measured. Walking velocity at HRVT in these tests (WV-HRVT1 and WV-HRVT2) was registered. During the 3rd ISWT, physiological responses were assessed. The ventilatory equivalents were used to determine ventilatory threshold (VT) and the WV at VT (WV-VT) was recorded. The difference between WV-HRVT1 and WV-HRVT2 was not statistically significant (median and interquartile range = 4.8; 4.8 to 5.4 vs4.8; 4.2 to 5.4 km/h); the correlation between WV-HRVT1 and WV-HRVT2 was significant (r = 0.84); the intraclass correlation coefficient was high (0.92; 0.82 to 0.96), and the agreement was acceptable (-0.08 km/h; -0.92 to 0.87). The difference between WV-VT and WV-HRVT2 was not statistically significant (4.8; 4.8 to 5.4 vs 4.8; 4.2 to 5.4 km/h) and the agreement was acceptable (0.04 km/h; -1.28 to 1.36). HRVT assessment during walking is a reliable measure and permits the estimation of VT in adults. We suggest the use of the ISWT for the assessment of exercise capacity in middle-aged and older adults.
Resumo:
Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To deliver the energy saving potential, there is a need for easily implementable methods to monitor the system output. This is because information is needed to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable speed drives have proven to be able to give information on the system output without additional metering; however, the current model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.
Electromagnetic and thermal design of a multilevel converter with high power density and reliability
Resumo:
Electric energy demand has been growing constantly as the global population increases. To avoid electric energy shortage, renewable energy sources and energy conservation are emphasized all over the world. The role of power electronics in energy saving and development of renewable energy systems is significant. Power electronics is applied in wind, solar, fuel cell, and micro turbine energy systems for the energy conversion and control. The use of power electronics introduces an energy saving potential in such applications as motors, lighting, home appliances, and consumer electronics. Despite the advantages of power converters, their penetration into the market requires that they have a set of characteristics such as high reliability and power density, cost effectiveness, and low weight, which are dictated by the emerging applications. In association with the increasing requirements, the design of the power converter is becoming more complicated, and thus, a multidisciplinary approach to the modelling of the converter is required. In this doctoral dissertation, methods and models are developed for the design of a multilevel power converter and the analysis of the related electromagnetic, thermal, and reliability issues. The focus is on the design of the main circuit. The electromagnetic model of the laminated busbar system and the IGBT modules is established with the aim of minimizing the stray inductance of the commutation loops that degrade the converter power capability. The circular busbar system is proposed to achieve equal current sharing among parallel-connected devices and implemented in the non-destructive test set-up. In addition to the electromagnetic model, a thermal model of the laminated busbar system is developed based on a lumped parameter thermal model. The temperature and temperature-dependent power losses of the busbars are estimated by the proposed algorithm. The Joule losses produced by non-sinusoidal currents flowing through the busbars in the converter are estimated taking into account the skin and proximity effects, which have a strong influence on the AC resistance of the busbars. The lifetime estimation algorithm was implemented to investigate the influence of the cooling solution on the reliability of the IGBT modules. As efficient cooling solutions have a low thermal inertia, they cause excessive temperature cycling of the IGBTs. Thus, a reliability analysis is required when selecting the cooling solutions for a particular application. The control of the cooling solution based on the use of a heat flux sensor is proposed to reduce the amplitude of the temperature cycles. The developed methods and models are verified experimentally by a laboratory prototype.
Resumo:
The goal of this thesis is to study user-driven innovations and user involvement throughout the innovation process in context of B2B companies. Significant emphasis in the analysis put onto the late stages of innovation process and commercialization of innovations. Thesis includes detailed review of theoretical concepts and underlying frameworks of innovation process, lead users and user-driven innovations. The empirical part of the thesis consist of interviews of the four companies from ICT industry, followed by the comprehensive analysis and comparison of the results. The presented findings indicate common challenges, which ICT companies face, when shifting towards innovation by users paradigm. Linkages and connections among current situation and theoretical frameworks presented in the discussion part of the thesis allow to draw practical managerial implications. The results of the research emphasize valuable insights and challenges of user interactions within innovation process as well as output and participation related benefits for the companies and users. The research points out current state of the user involvement techniques and tools used for user interactions as well as suggests the possibilities for improvement in the future.
Resumo:
This thesis studies energy efficiencies and technical properties of gas driven ground source heat pumps and pump systems. The research focuses on two technologies: gas engine driven compressor heat pump and thermally driven gas absorption heat pump. System consist of a gas driven compressor or absorption ground source heat pump and a gas condensing boiler, which covers peak load. The reference system is a standard electrically powered compressor heat pump with electric heating elements for peak load. The systems are compared through primary energy ratios. Coefficient of performances of different heat pump technologies are also compared. At heat pump level, gas driven heat pumps are having lower coefficient of performances as compared with corresponding electric driven heat pump. However, gas heat pumps are competitive when primary energy ratios, where electricity production losses are counted in, are compared. Technically, gas heat pumps can potentially achieve a slightly higher temperatures with greater total energy efficiency as compared to the electric driven heat pump. The primary energy ratios of gas heat pump systems in relation to EHP-system improves when the share of peak load increases. Electric heat pump system's overall energy efficiency is heavily dependent on the electricity production efficiency. Economy as well as CO2-emissions were not examined in this thesis, which however, would be good topics for further study.
Resumo:
The application of VSC-HVDC technology throughout the world has turned out to be an efficient solution regarding a large share of wind power in different power systems. This technology enhances the overall reliability of the grid by utilization of the active and reactive power control schemes which allows to maintain frequency and voltage on busbars of the end-consumers at the required level stated by the network operator. This master’s thesis is focused on the existing and planned wind farms as well as electric power system of the Åland Islands. The goal is to analyze the wind conditions of the islands and appropriately predict a possible production of the existing and planned wind farms with a help of WAsP software program. Further, to investigate the influence of increased wind power it is necessary to develop a simulation model of the electric grid and VSC-HVDC system in PSCAD and examine grid response to different wind power production cases with respect to the grid code requirements and ensure the stability of the power system.
Resumo:
The search for efficient and accessible cooling systems has increased worldwide. This study aims to build and evaluate an evaporative cooling system using a water driven ejector, allowing it to be installed in places with plenty of water. The system was investigated varying the flow rate and temperature of the circulating water, temperature of the replacement water, and coefficient of performance. The best vacuum obtained was 8.5 kPa at nominal operating conditions of 4.1 ± 0.1 m³/h and 5 ± 0.5 ºC for the circulating water reaching the temperature of 9.7 ± 0.5 ºC. The pulse-like disturbance generated by replacing the cooling water at different periods of times did not result in significant affect vacuum destabilization and the temperature rise in the cooling tank. The coefficient of performance of the system at the highest thermal power of 92.27 W was 0.077, which was underestimated due to possible problems related to pump efficiency. The system evaluated under the conditions proposed can be very efficient for cooling fluids at higher temperatures, and it can be complementary to main refrigeration systems.
Resumo:
The awareness and concern of our environment together with legislation have set more and more tightening demands for energy efficiency of non-road mobile machinery (NRMM). Integrated electro-hydraulic energy converter (IEHEC) has been developed in Lappeenranta University of Technology (LUT). The elimination of resistance flow, and the recuperation of energy makes it very efficient alternative. The difficulties of IEHEC machine to step to the market has been the requirement of one IEHEC machine per one actuator. The idea is to switch IEHEC between two actuators of log crane using fast on/off valves. The control system architecture is introduced. The system has been simulated in co-simulation using two different software. The simulated responses of pump-controlled system is compared to the responses of the conventional valve-controlled system.
Resumo:
Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.
Resumo:
Knowledge seems to need the admixture of de facto reliability and epistemic responsibility. But philosophers have had a hard time in attempting to combine them in order to achieve a satisfactory account of knowledge. In this paper I attempt to find a solution by capitalizing on the real and ubiquitous human phenomenon that is the social dispersal of epistemic labour through time. More precisely, the central objective of the paper is to deliver a novel and plausible social account of knowledge-relevant responsibility and to consider the merits of the proposed combination of reliability and responsibility with respect to certain cases of unreflective epistemic subjects.
Resumo:
Objectlve:--This study examined the intraclass reliability· of different measures of the
excitability of the Hoffmann reflex, derived from stimulus-response curves. The slope of the
regression line of the H-reflex stimulus-response curve advocated by Funase et al. (1994) was
also compared to the peak of the first derivative of the H-reflex stimulus-response curve
(dHIdVmax), a new measure introduced in this investigation. A secondary purpose was to explore
the possibility of mood as a covariate when measuring excitability of the H-reflex arc.
Methods: The H-reflex amplitude at a stimulus intensity corresponding to 5% of the
maximum M-wave (Mmax) is an established measure that was used as an additional basis of
comparison. The H-reflex was elicited in the soleus for 24 subjects (12 males and 12 females)
on five separate days. Vibration was applied to the Achilles tendon prior to stimulation to test
the sensitivity of the measures on test day four. The means of five evoked potentials at each
gradually increasing intensity, from below H-reflex threshold to above Mmax, were used to create
both the H-reflex and M-wave stimulus response curves for each subject across test days. The
mood of the subjects was assessed using the Subjective Exercise Experience Scale (SEES) prior
to the stimulation protocol each day.
Results: There was a modest decrease in all H-reflex measures from the first to third test day,
but it was non-significant (P's>0.05). All measures of the H-reflex exhibited a profound
reduction following vibration on test day four, and then returned to baseline levels on test day
five (P's<0.05). The intraclass correlation coefficient (ICC) for H-reflex amplitude at 5% of
Mmax was 0.85. The ICC for the slope of the regression line was 0.79 while it was 0.89 for
dH/dVmax. Maximum M-wave amplitude had an ICC of 0.96 attesting to careful methodological
controls. The SEES subscales of fatigue and psychological well-being remained unchanged
IV
across the five days. The psychological distress subscale (P
Resumo:
To date there is no documented procedure to extrapolate findings of an isometric nature to a whole body performance setting. The purpose of this study was to quantify the reliability of perceived exertion to control neuromuscular output during an isometric contraction. 21 varsity athletes completed a maximal voluntary contraction and a 2 min constant force contraction at both the start and end of the study. Between pre and post testing all participants completed a 2 min constant perceived exertion contraction once a day for 4 days. Intra-class correlation coefficient (R=O.949) and standard error of measurement (SEM=5.12 Nm) concluded that the isometric contraction was reliable. Limits of agreement demonstrated only moderate initial reliability, yet with smaller limits towards the end of 4 training sessions. In conclusion, athlete's na"ive to a constant effort isometric contraction will produce reliable and acceptably stable results after 1 familiarization sessions has been completed.
Resumo:
This document could not have been completed without the hard work of a number of individuals. First and foremost, my supervisor, Dr. David Gabriel deserves the utmost recognition for the immense effort and time spent guiding the production of this document through the various stages of completion. Also, aiding in the data collection, technical support, and general thought processing were Lab Technician Greig Inglis and fellow members of the Electromyographic Kinesiology Laboratory Jon Howard, Sean Lenhardt, Lara Robbins, and Corrine Davies-Schinkel. The input of Drs. Ted Clancy, Phil Sullivan and external examiner Dr. Anita Christie, all members ofthe assessment committee, was incredibly important and vital to the completion of this work. Their expertise provided a strong source of knowledge and went to ensure that this project was completed at exemplary level. There were a number of other individuals who were an immense help in getting this project off the ground and completed. The donation of their time and efforts was very generous and much needed in order to fulfill the requirements needed for completion of this study. Finally, I cannot exclude the contributions of my family throughout this project especially that of my parents whose support never wavers.
Resumo:
This study occurred in 2009 and questioned how Ontario secondary school principals perceived their role had changed, over a 7 year period, in response to the increased demands of data-driven school environments. Specifically, it sought to identify principals' perceptions on how high-stakes testing and data-driven environments had affected their role, tasks, and accountability responsibilities. This study contextualized the emergence of the Education Quality and Accountability Offices (EQAO) as a central influence in the creation of data-driven school environments, and conceptualized the role of the principal as using data to inform and persuade a shift in thinking about the use of data to improve instruction and student achievement. The findings of the study suggest that data-driven environments had helped principals reclaim their positional power as instructional leaders, using data as an avenue back into the classroom. The use of data shifted the responsibilities of the principal to persuade teachers to work collaboratively to improve classroom instruction in order to demonstrate accountability.