974 resultados para Ocular prostheses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report a case of Nocardia asteroides scleritis in a patient without risk factors for infeccious scleritis. METHODS: A 38-year old woman was initially examined for pain, discharge, photophobia of 1 month duration in her right eye. Her medical and ophthalmological history were unremarkable. The results of laboratory tests were normal. Surgical debridement of necrotic tissue was performed and material was sent for biopsy and culture confirmed as Nocardia asteroides. Treatment consisted of amikacin eyedrops, and systemic trimethropim-sulfamethoxazole. The infection resolved leaving scleral thinning and a subconjunctival fibrovascular scar. Best corrected visual acuity two months after referral had improved to LE, 20/20. CONCLUSION: Prompt evaluation and treatment is essential for successful management of Nocardia asteroides infectious scleritis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: In Divinolândia (SP), the Consortium of Development of São João da Boa Vista Region Policy (CONDERG), in partnership with State University of Campinas (UNICAMP), has founded an eyeglass store to produce low cost glasses to distribute freely to their customers. The purpose is to analyze the evolution and working process of CONDERG eyeglass store in the last 13 years, since its foundation. METHODS: Data were collected from CONDERG store files from 1988 to 2001. Data regarding the amount of spectacles produced per year, ability to increase the production and store feasibility were analyzed. RESULTS: In 13 years, 16,500 spectacles were supplied. Currently, 400 spectacles are delivered per month, being 200 supported by SUS and the other 200 by CONDERG's own resources. CONCLUSION: The 13-year operation of CONDERG eyeglass store, the free provision of 16,500 spectacles and the increase productive ability have shown this model feasibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To characterize the behavior of premature newborns in the first year of chronological age. METHODS: This is a cross-sectional descriptive study, bound to a longitudinal study titled: Comparison of visual behavior on the first quarter of year of life of premature nursling born at two maternities of Recife/PE. The sample was composed by 52 premature newborns selected from June, 2007 to June, 2008 from the Maternity of the Federal University of Pernambuco (UFPE). Biological, socioeconomic and demographic data was collected through medical records and interviews with progeny. Newborns were evaluated by the Assessment Guide of Visual Ability in Infants. RESULTS: Most of the newborns were male at a gestational period between 33 weeks and 36 weeks and 6 days, showed a good visual behavior development for the age researched, and most of the families showed good socioeconomical and demographic profile. Besides, it was possible to detect ocular signs in 19% of sample, that were referred to an Ophthalmology Service. CONCLUSION: This study results point out the method like an important key in the early detection and visual screening for premature nursling since the first month of life and it led us to believe that clinical view for occupational therapy intervention must be focused not only on biological risks but also at the influence environment in newborn performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a topiramate induced acute bilateral angle-closure glaucoma. This rare adverse effect is an idiosyncratic reaction characterized by uveal effusion and lens forward displacement, leading to increased intraocular pressure and vision loss. We describe a 55 year-old white woman with migraine, spasmodic torticollis and essential tremor, who developed bilateral acute angle-closure glaucoma, one week after starting topiramate 25 mg/day. She was seen at the Ophthalmology Emergency Department of the Fundação João Penido Burnier (Campinas, SP, Brazil) with a 4 hours history of blurry vision, ocular pain and bright flashes vision. Slit lamp examination revealed moderate conjunctival injection and corneal edema, and shallow anterior chambers. Intraocular pressure was 48 mmHg in both eyes. Fundoscopic examination findings were normal. She was treated with timolol, brimonidine, dorzolamide, pilocarpine, prednisone acetate eye drops and acetazolamide. One hour after those measures, as the intraocular pressure was 30 mmHg, she received a manitol intravenous injection and the intraocular pressure normalized. After 24 hours an iridotomy with Yag laser was performed. Topiramate was discontinued and she was totally recovered after one week.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dry eye disease and ocular surface disorders may be caused or worsened by viral agents. There are several known and suspected virus associated to ocular surface diseases. The possible pathogenic mechanisms for virus-related dry eye disease are presented herein. This review serves to reinforce the importance of ophthalmologists as one of the healthcare professional able to diagnose a potentially large number of infected patients with high prevalent viral agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Facial trauma can be considered one of the most serious aggressions found in the medical centers due to the emotional consequences and the possibility of deformity. In craniofacial surgery, the use of autologous bone is still the first choice for reconstructing bony defects or irregularities. When there is a shortage of donor bone or a patient refuses an intracranial operation, alloplastic materials such as polymethylmethacrylate (PMMA) can be used. The PMMA prosthesis can be pre-fabricated, bringing advantages such as reduction of surgical time, easy technical handling and good esthetic results. This paper describes the procedures for rehabilitating a patient with PMMA implants in the region of the face, recovering the facial contours and esthetics of the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (a=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using a resin coping impression technique with individual shells. A master cast made of stainless steel with fixed prosthesis characteristics with two prepared abutment teeth was used to obtain the impressions. References points (A, B, C, D, E and F) were recorded on the occlusal and buccal surfaces of abutments to register the distances. The impressions were obtained using the following materials: polyether, mercaptan-polysulfide, addition silicone, and condensation silicone. The transfer impressions were made with custom trays and an irreversible hydrocolloid material and were poured with type IV gypsum. The distances between identified points in gypsum dies were measured using an optical microscope and the results were statistically analyzed by ANOVA (p < 0.05) and Tukey's test. The mean of the distances were registered as follows: addition silicone (AB = 13.6 µm, CD=15.0 µm, EF = 14.6 µm, GH=15.2 µm), mercaptan-polysulfide (AB = 36.0 µm, CD = 36.0 µm, EF = 39.6 µm, GH = 40.6 µm), polyether (AB = 35.2 µm, CD = 35.6 µm, EF = 39.4 µm, GH = 41.4 µm) and condensation silicone (AB = 69.2 µm, CD = 71.0 µm, EF = 80.6 µm, GH = 81.2 µm). All of the measurements found in gypsum dies were compared to those of a master cast. The results demonstrated that the addition silicone provides the best stability of the compounds tested, followed by polyether, polysulfide and condensation silicone. No statistical differences were obtained between polyether and mercaptan-polysulfide materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biological fixation between the dental implant surfaces and jaw bones should be considered a prerequisite for the long-term success of implant-supported prostheses. In this context, the implant surface modifications gained an important and decisive place in implant research over the last years. As the most investigated topic in, it aided the development of enhanced dental treatment modalities and the expansion of dental implant use. Nowadays, a large number of implant types with a great variety of surface properties and other features are commercially available and have to be treated with caution. Although surface modifications have been shown to enhance osseointegration at early implantation times, for example, the clinician should look for research evidence before selecting a dental implant for a specific use. This paper reviews the literature on dental implant surfaces by assessing in vitro and in vivo studies to show the current perspective of implant development. The review comprises quantitative and qualitative results on the analysis of bone-implant interface using micro and nano implant surface topographies. Furthermore, the perspective of incorporating biomimetic molecules (e.g.: peptides and bone morphogenetic proteins) to the implant surface and their effects on bone formation and remodeling around implants are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports a rare case of acute severe orbital abscess manifested 2 days after a facial trauma without bone fracture in a 20-year-old Afro-American female. The symptoms worsened within the 24 h prior to hospital admission resulting in visual disturbances such as diplopia and photophobia. The clinical findings at the first consultation included fever, periorbital swelling and redness, ptosis, proptosis and limitation of ocular movements upwards, downwards, to the right and to the left. Computed tomography scan showed proptosis with considerable soft tissue swelling on the left side and no fracture was evidenced in the facial skeleton, including the zygomatic-orbital complex. After hospital admission and antibiotic therapy intravenously the patient was conducted to the operation room and submitted to incision and drainage under general anesthesia. The orbit was approached thorough both eyelids and the maxillary sinus was reached only through the Caldwell-Luc approach. The postoperative period was uneventful and the rapid improvement of symptoms was remarkable. Visual acuity and ocular motility returned to the normal ranges within 2 days after the surgical intervention. After 12 postoperative days, the patient presented with significative improvement in the ptosis and proptosis, and acceptable scars.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nocardia is a rare opportunistic agent, which may affect immunocompromised individuals causing lung infections and exceptionally infective endocarditis (IE). There are few reports of IE caused by Nocardia sp., usually involving biological prostheses but rarely in natural valves. Its accurate microbiological identification may be hampered by the similarity with Rhodococcus equi and Corynebacterium spp. Here we report a case of native mitral valve IE caused by this agent in which the clinical absence of response to vancomycin and the suggestion of Nocardia sp. by histology pointed to the misdiagnosis of Corynebacterium spp. in blood cultures. The histological morphology can advise on the need for expansion of cultivation time and use of extra microbiological procedures that lead to the differential diagnosis with Corynebacterium spp. and other agents, which is essential to establish timely specific treatment, especially in immunocompromised patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to determine the cardiopulmonary effects and eyeball centralization time obtained with 15 or 30µg kg-1 of atracurium in anesthetized dogs under spontaneous breathing. Eighteen healthy adult mixed-breed dogs were used, which received 0.1mg kg-1 acepromazine and 0.5mg kg-1 morphine IM, followed by 4mg kg-1 propofol IV and maintained on isoflurane anesthesia with spontaneous breathing. Animals received 1mL 0.9% NaCl IV (CG), 15µg kg-1 (G15) or 30µg kg-1 (G30) of atracurium IV. Eyeball centralization time was measured; heart rate (HR), systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures, respiratory rate (RR), tidal volume (Vt) and minute volume (Vm) were determined every 5min, and pH, arterial CO2 pressure (PaCO2 ), arterial O2 pressure (PaO2 ), hemoglobin oxygen saturation (SaO2 ), bicarbonate (HCO3-) and base excess (BE) every 15min until 60min. Both doses of atracurium produced a similar period of eyeball centralization. Vt in groups treated with atracurium was lower than in CG up to 15min. Vm in G15 differed from CG up to 10min and in G30 up to 25min. No differences were observed for cardiovascular parameters, RR, SaO2, PaO2, HCO3- and BE. pH decreased in CG between 30 and 60min and in G15 and G30 at 15min. G30 differed from CG between 15 and 30min. PaCO2 in GC differed from baseline between 30 and 60min and in G15 differed at 15min. Atracurium at the dose of 15µg kg-1 is adequate for short corneal procedures in inhalant-anesthetized dogs under spontaneous breathing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Troglobitic (exclusively subterranean) organisms usually present, among their apomorphies related to the subterranean life (troglomorphisms), the regression of eyes and melanic pigmentation. The degree of regression varies among species, from a slight reduction to the complete loss of eyes and dark pigmentation, without a taxonomic correlation. While mechanisms of eye reduction have been intensively investigated in some troglobites such as the Mexican blind tetra characins, genus Astyanax, and the European salamander, Proteus anguinus, few studies have focused on pigmentation. The Brazilian subterranean ichthyofauna distinguishes not only by the species richness (23 troglobitic fishes so far known) but also by the variation in the degree of reduction of eyes and pigmentation. This study focused on Brazilian fishes completely devoid of melanic pigmentation: the characiform Stygichthys typhlops (Characidae) and the siluriforms Ancistrus formoso (Loricariidae), Rhamdiopsis sp.1 (Heptapteridae; from caves in the Chapada Diamantina, Bahia) and Rhamdiopsis sp. 2 (cave in Campo Formoso, Bahia). In order to investigate if such depigmentation is the result of blockage in some step in the melanogenesis, in vitro tests of administration of L-DOPA were done, using caudal-fin fragments extracted from living fish. Except for Rhamdiopsis sp. 2, all the studied species were DOPA(+), i.e., melanin was synthesized after L-DOPA administration. This indicates these fish do have melanophores but they are unable to convert L-tyrosine to L-DOPA. On the other hand, Rhamdiopsis sp. 2, like the albino specimens of Trichomycterus itacarambiensis previously studied (which correspond to one third of the population), are DOPA(-), either because the block of melanin synthesis occurs downstream in melanogenesis, which is probably the case with T. itacarambiensis (monogenic system in view of the phenotypic discontinuity), or because the so-called albinos do no possess melanophores. The physiological loss in the ability to synthesize melanin, apparently caused by different genetic processes in DOPA(+) and in DOPA(-) fishes, may co-exist in subterranean populations with a decrease in the density of melanophores, as observed in the pigmented two thirds of T. itacarambiensis population, a morphological reduction apparently controlled by polygenic systems producing a continuous phenotypic variation.