997 resultados para Monitoramento orbital
Resumo:
Background: This is the first report of involvement of Australian and New Zealand oral and maxillofacial surgeons in the management of isolated orbital floor blow-out fractures and was conducted to obtain comparisons with the results from a recent similar survey of British oral and maxillofacial surgeons. Methods: A questionnaire survey was sent to all 113 practising members of the Australian and New Zealand Association of Oral and Maxillofacial Surgeons in April 2002 with a second mailout 1 month later. Results: Sixty-nine per cent of the respondents were referred isolated orbital floor blow-out fractures for manage-ment, and just over half of these respondents estimated that 50% or more of the cases went to surgery. The materials most commonly used in orbital floor reconstruction were resorbable membrane for small defects and autologous bone for large defects. Conclusion: As in Britain, management of isolated orbital floor blow-out fractures comprises part of the surgical spectrum for many oral and maxillofacial surgeons in Australia and New Zealand. The management protocol was observed to be very similar between the two groups.
Resumo:
We study a generalized Hubbard model on the two-leg ladder at zero temperature, focusing on a parameter region with staggered flux (SF)/d-density wave (DDW) order. To guide our numerical calculations, we first investigate the location of a SF/DDW phase in the phase diagram of the half-filled weakly interacting ladder using a perturbative renormalization group (RG) and bosonization approach. For hole doping 6 away from half-filling, finite-system density-matrix renormalizationgroup (DMRG) calculations are used to study ladders with up to 200 rungs for intermediate-strength interactions. In the doped SF/DDW phase, the staggered rung current and the rung electron density both show periodic spatial oscillations, with characteristic wavelengths 2/delta and 1/delta, respectively, corresponding to ordering wavevectors 2k(F) and 4k(F) for the currents and densities, where 2k(F) = pi(1 - delta). The density minima are located at the anti-phase domain walls of the staggered current. For sufficiently large dopings, SF/DDW order is suppressed. The rung density modulation also exists in neighboring phases where currents decay exponentially. We show that most of the DMRG results can be qualitatively understood from weak-coupling RG/bosonization arguments. However, while these arguments seem to suggest a crossover from non-decaying correlations to power-law decay at a length scale of order 1/delta, the DMRG results are consistent with a true long-range order scenario for the currents and densities. (c) 2005 Elsevier Inc. All rights reserved.
Resumo:
Objective: To present the clinical features and management outcome in a large series of patients with periocular and orbital amyloidosis. Design: Retrospective, noncomparative, interventional case series. Patients: All patients diagnosed with periocular and orbital amyloidosis in 6 oculoplastic and orbital units. Methods: Clinical records of all patients were reviewed. Main Outcome Measures: Clinical presentation, radiological and histological findings, treatment modalities, and outcome. Results. The study included 24 patients (15 female, 9 male) with a mean age of 57 17 years. Nineteen cases were unilateral, and 5 were bilateral. Clinical signs and symptoms included a visible or palpable periocular mass or tissue infiltration (95.8%), ptosis (54.2%), periocular discomfort or pain (25%), proptosis or globe displacement (21%), limitations in ocular motility (16.7%), recurrent periocular subcutaneous hemorrhages (12.5%), and diplopia (8.3%). Seven cases had orbital involvement, and 17 were periocular. Immunohistochemistry in 7 patients showed B cells or plasma cells producing monoclonal immunoglobulin chains that were deposited as amyloid light chains. Only 1 patient was diagnosed with systemic amyloid light chain amyloidosis. Treatment modalities were mainly observation and surgical debulking. During a mean follow-up period of 39 months, 21% showed significant progression after treatment, whereas 79% were stable or showed no recurrence after treatment. Conclusion: Periocular and orbital amyloidosis may present with a wide spectrum of clinical findings and result in significant ocular morbidity. Complete surgical excision is not feasible in many cases, and the goal of treatment is to preserve function and to prevent sight-threatening complications.
Resumo:
Objective: To perform a multicenter review of the clinical features and treatment of 31 patients with idiopathic sclerosing orbital inflammation. Methods: We included all patients with histologically confirmed idiopathic sclerosing orbital inflammation from 5 regional orbital centers. We reviewed the case notes to determine the clinical presentation, diagnostic features, and response to treatment. The main outcome measures were duration and nature of symptoms, anatomical location of disease, histopathological findings, treatment modalities, treatment efficacy and adverse effects, and final clinical status. Results: We included 13 male and 18 female patients ranging in age from 7 to 83 years. The average duration of symptoms at presentation was 13.4 months. There was a predilection for the lateral and superior quadrants. Thirteen patients had apical disease, and 4 had extraorbital involvement. Histopathological findings invariably showed sclerosis associated with a sparse mixed cellular infiltrate. Twenty- seven patients were treated with oral prednisolone, response to which was good in 9 patients, partial in 11, and poor in 7. Six patients were treated with a second- line immunosuppressive agent, and 6 received radiotherapy. The response to radiotherapy was generally poor. Conclusions: Idiopathic sclerosing orbital inflammation is a rare condition that can be difficult to diagnose and manage. Early intervention with immunosuppression in the form of corticosteroids combinedwith secondline agents can result in control and even regression of the disease.
Resumo:
The whole set of the nickel(II) complexes with no derivatized edta-type hexadentate ligands has been investigated from their structural and electronic properties. Two more complexes have been prepared in order to complete the whole set: trans(O5)-[Ni(ED3AP)]2- and trans(O5O6)-[Ni(EDA3P)]2- complexes. trans(O5) geometry has been verified crystallographically and trans(O5O6) geometry of the second complex has been predicted by the DFT theory and spectral analysis. Mutual dependance has been established between: the number of the five-membered carboxylate rings, octahedral/tetrahedral deviation of metal-ligand/nitrogen-neighbour-atom angles and charge-transfer energies (CTE) calculated by the Morokuma’s energetic decomposition analysis; energy of the absorption bands and HOMO–LUMO gap.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
This study is concerned with gravity field recovery from low-low satellite to satellite range rate data. An improvement over a coplanar mission is predicted in the errors associated with certain parts of the geopotential by the separation of the orbital planes of the two satellites. Using Hill's equations an analytical scheme to model the range rate residuals is developed. It is flexible enough to model equally well the residuals between pairs of satellites in the same orbital plane or whose planes are separated in right ascension. The possible benefits of such an orientation to gravity field recovery from range rate data can therefore be analysed, and this is done by means of an extensive error analysis. The results of this analysis show that for an optimal planar mission improvements can be made by separating the satellites in right ascension. Gravity field recoveries are performed in order to verify and gauge the limitations of the analytical model, and to support the results of the error analysis. Finally the possible problem of the differential decay rates of two satellites due to the diurnal bulge are evaluated.
Resumo:
Heavy metals are present in industrial waste. These metals can generate a large environmental impact contaminating water, soil and plants. The chemical action of heavy metals has attracted environmental interest. In this context, this study aimed to test t he performance of electrochemical technologies for removing and quantifying heavy metals. First ly , the electroanalytical technique of stripping voltammetry with glassy carbon electrode (GC) was standardized in order to use this method for the quantificatio n of metals during their removal by electrocoagulation process (EC). A nalytical curves were evaluated to obtain reliability of the determin ation and quantification of Cd 2+ and Pb 2+ separately or in a mixture. Meanwhile , EC process was developed using an el ectrochemical cell in a continuous flow (EFC) for removing Pb 2+ and Cd 2+ . The se experiments were performed using Al parallel plates with 10 cm of diameter ( 63.5 cm 2 ) . The optimization of conditions for removing Pb 2+ and Cd 2+ , dissolved in 2 L of solution at 151 L h - 1 , were studied by applying different values of current for 30 min. Cd 2+ and Pb 2+ concentrations were monitored during electrolysis using stripping voltammetry. The results showed that the removal of Pb 2 + was effective when the EC pro cess is used, obtaining removals of 98% in 30 min. This behavior is dependent on the applied current, which implies an increase in power consumption. From the results also verified that the stripping voltammetry technique is quite reliable deter mining Pb 2+ concentration , when compared with the measurements obtained by atomic absorption method (AA). In view of this, t he second objective of this study was to evaluate the removal of Cd 2+ and Pb 2+ (mixture solution) by EC . Removal efficiency increasing current was confirmed when 93% and 100% of Cd 2+ and Pb 2+ was removed after 30 min . The increase in the current promotes the oxidation of sacrificial electrodes, and consequently increased amount of coagulant, which influences the removal of heavy metals in solution. Adsortive voltammetry is a fast, reliable, economical and simple way to determine Cd 2+ and Pb 2+ during their removal. I t is more economical than those normally used, which require the use of toxic and expensive reagents. Our results demonstrated the potential use of electroanalytical techniques to monitor the course of environmental interventions. Thus, the application of the two techniques associated can be a reliable way to monitor environmental impacts due to the pollution of aquatic ecosystems by heavy metals.