947 resultados para Medical laboratory technology


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Carbonate sediments are dynamic three-dimensional environments where the surface layers are constantly moving and mixing due to the energy of the water column. It is also an environment of dynamic biological, chemical and physical interaction and modification. The biological community can actively influence changes to sediment characteristics and associated biochemistry. Bioturbation resulting from macrofaunal activity disrupts sediment structure and biochemical arrangements and reduces the critical shear forces required to move sediment particles, adding to the dynamic and complex physical and biogeochemical nature of the sediment. Laboratory studies using both planner optodes and glass needle microsensors were used to measure abiotic sediment characteristics such as the depth distribution and concentrations of PAR. The biochemical nature of coral reef sediment were also investigated, specifically the quantification and the distribution of dissolved oxygen within coarse and fine-grained sediments under regimes of light and darkness. Results highlighted the significant contribution microalgal productivity and bioturbation has on distribution of dissolved oxygen in the upper sediment layers. On the reef flat a shallow water lander system was employed to measure concentrations of O2, pH, S, Ca and temperature over periods of 24 to 48 hours in coarse and fine-grained sediments. Similarities between laboratory and in situ results where evident, however the in situ environment was more dynamic and the distribution and concentrations of dissolved oxygen were more complex and correlated to irradiance, temperature and biological activity. Microsensor technology provides us with the opportunity to study, at very high resolutions, the upper irradiated; photosynthetically active regions of aquatic sediments along with anoxic processes deeper in sub-euphotic regions of the sediments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The adoption of DRG coding may be seen as a central feature of the mechanisms of the health reforms in New Zealand. This paper presents a story of the use of DRG coding by describing the experience of one major health provider. The conventional literature portrays casemix accounting and medical coding systems as rational techniques for the collection and provision of information for management and contracting decisions/negotiations. Presents a different perspective on the implications and effects of the adoption of DRG technology, in particular the part played by DRG coding technology as a part of a casemix system is explicated from an actor network theory perspective. Medical coding and the DRG methodology will be argued to represent ``black boxes''. Such technological ``knowledge objects'' provide strong points in the networks which are so important to the processes of change in contemporary organisations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel quasidistributed in-fiber Bragg grating (FBG) temperature sensor system has been developed for temperature proving in vivo in the human body for medical applications, e.g., hyperthermia treatment. This paper provides the operating principle of FBG temperature sensors and then the design of the sensor head. High-resolution detection of the wavelength-shifts induced by temperature changes are achieved using drift-compensated interferometric detection while the return signals from the FBG sensor array are demultiplexed with a simple monochromator which offers crosstalk-free wavelength-division-multiplexing (WDM). A “strain-free” probe is designed by enclosing the FBG sensor array in a protection sleeve. A four FBG sensor system is demonstrated and the experimental results are in good agreement with those obtained by traditional electrical thermocouple sensors. A resolution of 0.1°C and an accuracy of ±0.2°C over a temperature range of 30-60°C have been achieved, which meet established medical requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis described the research carried out on the development of a novel hardwired tactile sensing system tailored for the application of a next generation of surgical robotic and clinical devices, namely a steerable endoscope with tactile feedback, and a surface plate for patient posture and balance. Two case studies are examined. The first is a one-dimensional sensor for the steerable endoscope retrieving shape and ‘touch’ information. The second is a two-dimensional surface which interprets the three-dimensional motion of a contacting moving load. This research can be used to retrieve information from a distributive tactile sensing surface of a different configuration, and can interpret dynamic and static disturbances. This novel approach to sensing has the potential to discriminate contact and palpation in minimal invasive surgery (MIS) tools, and posture and balance in patients. The hardwired technology uses an embedded system based on Field Programmable Gate Arrays (FPGA) as the platform to perform the sensory signal processing part in real time. High speed robust operation is an advantage from this system leading to versatile application involving dynamic real time interpretation as described in this research. In this research the sensory signal processing uses neural networks to derive information from input pattern from the contacting surface. Three neural network architectures namely single, multiple and cascaded were introduced in an attempt to find the optimum solution for discrimination of the contacting outputs. These architectures were modelled and implemented into the FPGA. With the recent introduction of modern digital design flows and synthesis tools that essentially take a high-level sensory processing behaviour specification for a design, fast prototyping of the neural network function can be achieved easily. This thesis outlines the challenge of the implementations and verifications of the performances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background - Menorrhagia is a common problem, yet evidence to inform decisions about therapy is limited. In a pragmatic, multicenter, randomized trial, we compared the levonorgestrel-releasing intrauterine system (levonorgestrel-IUS) with usual medical treatment in women with menorrhagia who presented to their primary care providers. Methods - We randomly assigned 571 women with menorrhagia to treatment with levonorgestrel-IUS or usual medical treatment (tranexamic acid, mefenamic acid, combined estrogen–progestogen, or progesterone alone). The primary outcome was the patient-reported score on the Menorrhagia Multi-Attribute Scale (MMAS) (ranging from 0 to 100, with lower scores indicating greater severity), assessed over a 2-year period. Secondary outcomes included general quality-of-life and sexual-activity scores and surgical intervention. Results - MMAS scores improved from baseline to 6 months in both the levonorgestrel-IUS group and the usual-treatment group (mean increase, 32.7 and 21.4 points, respectively; P<0.001 for both comparisons). The improvements were maintained over a 2-year period but were significantly greater in the levonorgestrel-IUS group than in the usual-treatment group (mean between-group difference, 13.4 points; 95% confidence interval, 9.9 to 16.9; P<0.001). Improvements in all MMAS domains (practical difficulties, social life, family life, work and daily routine, psychological well-being, and physical health) were significantly greater in the levonorgestrel-IUS group than in the usual-treatment group, and this was also true for seven of the eight quality-of-life domains. At 2 years, more of the women were still using the levonorgestrel-IUS than were undergoing the usual medical treatment (64% vs. 38%, P<0.001). There were no significant between-group differences in the rates of surgical intervention or sexual-activity scores. There were no significant differences in serious adverse events between groups. Conclusions - In women with menorrhagia who presented to primary care providers, the levonorgestrel-IUS was more effective than usual medical treatment in reducing the effect of heavy menstrual bleeding on quality of life. (Funded by the National Institute of Health Research Health Technology Assessment Programme; ECLIPSE Controlled-Trials.com number, ISRCTN86566246.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel quasidistributed in-flber Bragg grating (FBG) temperature sensor system has been developed for temperature profiling in vivo in the human body for medical applications, e.g., hyperthermia treatment. This paper provides the operating principle of FBG temperature sensors and then the design of the sensor head. High-resolution detection of the wavelength-shifts induced by temperature changes are achieved using drift-compensated interferometric detection while the return signals from the FBG sensor array are demultiplexed with a simple monochromator which offers crosstalk-free wavelength-division-multiplexing (WDM). A "strain-free" probe is designed by enclosing the FBG sensor array in a protection sleeve. A four FBG sensor system is demonstrated and the experimental results are in good agreement with those obtained by traditional electrical thermocouple sensors. A resolution of 0.1°C and an accuracy of ±0.2°C over a temperature range of 30-60°C have been achieved, which meet established medical requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quarter century since the foundation of the Royal College of Ophthalmologists has coincided with immense change in the subspecialty of medical retina, which has moved from being the province of a few dedicated enthusiasts to being an integral, core part of ophthalmology in every eye department. In age-related macular degeneration, there has been a move away from targeted, destructive laser therapy, dependent on fluorescein angiography to intravitreal injection therapy of anti-growth factor agents, largely guided by optical coherence tomography. As a result of these changes, ophthalmologists have witnessed a marked improvement in visual outcomes for their patients with wet age-related macular degeneration (AMD), while at the same time developing and enacting entirely novel ways of delivering care. In the field of diabetic retinopathy, this period also saw advances in laser technology and a move away from highly destructive laser photocoagulation treatment to gentler retinal laser treatments. The introduction of intravitreal therapies, both steroids and anti-growth factor agents, has further advanced the treatment of diabetic macular oedema. This era has also seen in the United Kingdom the introduction of a coordinated national diabetic retinopathy screening programme, which offers an increasing hope that the burden of blindness from diabetic eye disease can be lessened. Exciting future advances in retinal imaging, genetics, and pharmacology will allow us to further improve outcomes for our patients and for ophthalmologists specialising in medical retina, the future looks very exciting but increasingly busy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper briefly reviews CMOS image sensor technology and its utilization in security and medical applications. The role and future trends of image sensors in each of the applications are discussed. To provide the reader deeper understanding of the technology aspects the paper concentrates on the selected applications such as surveillance, biometrics, capsule endoscopy and artificial retina. The reasons for concentrating on these applications are due to their importance in our daily life and because they present leading-edge applications for imaging systems research and development. In addition, review of image sensors implementation in these applications allows the reader to investigate image sensor technology from the technical and from other views as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results of research the intelligence multimodal man-machine interface and virtual reality means for assistive medical systems including computers and mechatronic systems (robots) are discussed. The gesture translation for disability peoples, the learning-by-showing technology and virtual operating room with 3D visualization are presented in this report and were announced at International exhibition "Intelligent and Adaptive Robots–2005".

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There have been multifarious approaches in building expert knowledge in medical or engineering field through expert system, case-based reasoning, model-based reasoning and also a large-scale knowledge-based system. The intriguing factors with these approaches are mainly the choices of reasoning mechanism, ontology, knowledge representation, elicitation and modeling. In our study, we argue that the knowledge construction through hypermedia-based community channel is an effective approach in constructing expert’s knowledge. We define that the knowledge can be represented as in the simplest form such as stories to the most complex ones such as on-the-job type of experiences. The current approaches of encoding experiences require expert’s knowledge to be acquired and represented in rules, cases or causal model. We differentiate the two types of knowledge which are the content knowledge and socially-derivable knowledge. The latter is described as knowledge that is earned through social interaction. Intelligent Conversational Channel is the system that supports the building and sharing on this type of knowledge.