969 resultados para Markov chain Monte Carlo techniques
Resumo:
Wydział Chemii
Resumo:
Dissertação (Mestrado em Tecnologia Nuclear)
Resumo:
Dissertação (Mestrado em Tecnologia Nuclear)
Resumo:
Sequential panel selection methods (spsms — procedures that sequentially use conventional panel unit root tests to identify I(0)I(0) time series in panels) are increasingly used in the empirical literature. We check the reliability of spsms by using Monte Carlo simulations based on generating directly the individual asymptotic pp values to be combined into the panel unit root tests, in this way isolating the classification abilities of the procedures from the small sample properties of the underlying univariate unit root tests. The simulations consider both independent and cross-dependent individual test statistics. Results suggest that spsms may offer advantages over time series tests only under special conditions.
Resumo:
A investigação na área da saúde e a utilização dos seus resultados tem funcionado como base para a melhoria da qualidade de cuidados, exigindo dos profissionais de saúde conhecimentos na área específica onde desempenham funções, conhecimentos em metodologia de investigação que incluam as técnicas de observação, técnicas de recolha e análise de dados, para mais facilmente serem leitores capacitados dos resultados da investigação. Os profissionais de saúde são observadores privilegiados das respostas humanas à saúde e à doença, podendo contribuir para o desenvolvimento e bem-estar dos indivíduos muitas vezes em situações de grande vulnerabilidade. Em saúde infantil e pediatria o enfoque está nos cuidados centrados na família privilegiando-se o desenvolvimento harmonioso da criança e jovem, valorizando os resultados mensuráveis em saúde que permitam determinar a eficácia das intervenções e a qualidade de saúde e de vida. No contexto pediátrico realçamos as práticas baseadas na evidência, a importância atribuída à pesquisa e à aplicação dos resultados da investigação nas práticas clínicas, assim como o desenvolvimento de instrumentos de mensuração padronizados, nomeadamente as escalas de avaliação, de ampla utilização clínica, que facilitam a apreciação e avaliação do desenvolvimento e da saúde das crianças e jovens e resultem em ganhos em saúde. A observação de forma sistematizada das populações neonatais e pediátricas com escalas de avaliação tem vindo a aumentar, o que tem permitido um maior equilíbrio na avaliação das crianças e também uma observação baseada na teoria e nos resultados da investigação. Alguns destes aspetos serviram de base ao desenvolvimento deste trabalho que pretende dar resposta a 3 objetivos fundamentais. Para dar resposta ao primeiro objetivo, “Identificar na literatura científica, os testes estatísticos mais frequentemente utilizados pelos investigadores da área da saúde infantil e pediatria quando usam escalas de avaliação” foi feita uma revisão sistemática da literatura, que tinha como objetivo analisar artigos científicos cujos instrumentos de recolha de dados fossem escalas de avaliação, na área da saúde da criança e jovem, desenvolvidas com variáveis ordinais, e identificar os testes estatísticos aplicados com estas variáveis. A análise exploratória dos artigos permitiu-nos verificar que os investigadores utilizam diferentes instrumentos com diferentes formatos de medida ordinal (com 3, 4, 5, 7, 10 pontos) e tanto aplicam testes paramétricos como não paramétricos, ou os dois em simultâneo, com este tipo de variáveis, seja qual for a dimensão da amostra. A descrição da metodologia nem sempre explicita se são cumpridas as assunções dos testes. Os artigos consultados nem sempre fazem referência à distribuição de frequência das variáveis (simetria/assimetria) nem à magnitude das correlações entre os itens. A leitura desta bibliografia serviu de suporte à elaboração de dois artigos, um de revisão sistemática da literatura e outro de reflexão teórica. Apesar de terem sido encontradas algumas respostas às dúvidas com que os investigadores e os profissionais, que trabalham com estes instrumentos, se deparam, verifica-se a necessidade de desenvolver estudos de simulação que confirmem algumas situações reais e alguma teoria já existente, e trabalhem outros aspetos nos quais se possam enquadrar os cenários reais de forma a facilitar a tomada de decisão dos investigadores e clínicos que utilizam escalas de avaliação. Para dar resposta ao segundo objetivo “Comparar a performance, em termos de potência e probabilidade de erro de tipo I, das 4 estatísticas da MANOVA paramétrica com 2 estatísticas da MANOVA não paramétrica quando se utilizam variáveis ordinais correlacionadas, geradas aleatoriamente”, desenvolvemos um estudo de simulação, através do Método de Monte Carlo, efetuado no Software R. O delineamento do estudo de simulação incluiu um vetor com 3 variáveis dependentes, uma variável independente (fator com três grupos), escalas de avaliação com um formato de medida com 3, 4, 5, e 7 pontos, diferentes probabilidades marginais (p1 para distribuição simétrica, p2 para distribuição assimétrica positiva, p3 para distribuição assimétrica negativa e p4 para distribuição uniforme) em cada um dos três grupos, correlações de baixa, média e elevada magnitude (r=0.10, r=0.40, r=0.70, respetivamente), e seis dimensões de amostras (n=30, 60, 90, 120, 240, 300). A análise dos resultados permitiu dizer que a maior raiz de Roy foi a estatística que apresentou estimativas de probabilidade de erro de tipo I e de potência de teste mais elevadas. A potência dos testes apresenta comportamentos diferentes, dependendo da distribuição de frequência da resposta aos itens, da magnitude das correlações entre itens, da dimensão da amostra e do formato de medida da escala. Tendo por base a distribuição de frequência, considerámos três situações distintas: a primeira (com probabilidades marginais p1,p1,p4 e p4,p4,p1) em que as estimativas da potência eram muito baixas, nos diferentes cenários; a segunda situação (com probabilidades marginais p2,p3,p4; p1,p2,p3 e p2,p2,p3) em que a magnitude das potências é elevada, nas amostras com dimensão superior ou igual a 60 observações e nas escalas com 3, 4,5 pontos e potências de magnitude menos elevada nas escalas com 7 pontos, mas com a mesma ma magnitude nas amostras com dimensão igual a 120 observações, seja qual for o cenário; a terceira situação (com probabilidades marginais p1,p1,p2; p1,p2,p4; p2,p2,p1; p4,p4,p2 e p2,p2,p4) em que quanto maiores, a intensidade das correlações entre itens e o número de pontos da escala, e menor a dimensão das amostras, menor a potência dos testes, sendo o lambda de Wilks aplicado às ordens mais potente do que todas as outra s estatísticas da MANOVA, com valores imediatamente a seguir à maior raiz de Roy. No entanto, a magnitude das potências dos testes paramétricos e não paramétricos assemelha-se nas amostras com dimensão superior a 90 observações (com correlações de baixa e média magnitude), entre as variáveis dependentes nas escalas com 3, 4 e 5 pontos; e superiores a 240 observações, para correlações de baixa intensidade, nas escalas com 7 pontos. No estudo de simulação e tendo por base a distribuição de frequência, concluímos que na primeira situação de simulação e para os diferentes cenários, as potências são de baixa magnitude devido ao facto de a MANOVA não detetar diferenças entre grupos pela sua similaridade. Na segunda situação de simulação e para os diferentes cenários, a magnitude das potências é elevada em todos os cenários cuja dimensão da amostra seja superior a 60 observações, pelo que é possível aplicar testes paramétricos. Na terceira situação de simulação, e para os diferentes cenários quanto menor a dimensão da amostra e mais elevada a intensidade das correlações e o número de pontos da escala, menor a potência dos testes, sendo a magnitude das potências mais elevadas no teste de Wilks aplicado às ordens, seguido do traço de Pillai aplicado às ordens. No entanto, a magnitude das potências dos testes paramétricos e não paramétricos assemelha-se nas amostras com maior dimensão e correlações de baixa e média magnitude. Para dar resposta ao terceiro objetivo “Enquadrar os resultados da aplicação da MANOVA paramétrica e da MANOVA não paramétrica a dados reais provenientes de escalas de avaliação com um formato de medida com 3, 4, 5 e 7 pontos, nos resultados do estudo de simulação estatística” utilizaram-se dados reais que emergiram da observação de recém-nascidos com a escala de avaliação das competências para a alimentação oral, Early Feeding Skills (EFS), o risco de lesões da pele, com a Neonatal Skin Risk Assessment Scale (NSRAS), e a avaliação da independência funcional em crianças e jovens com espinha bífida, com a Functional Independence Measure (FIM). Para fazer a análise destas escalas foram realizadas 4 aplicações práticas que se enquadrassem nos cenários do estudo de simulação. A idade, o peso, e o nível de lesão medular foram as variáveis independentes escolhidas para selecionar os grupos, sendo os recém-nascidos agrupados por “classes de idade gestacional” e por “classes de peso” as crianças e jovens com espinha bífida por “classes etárias” e “níveis de lesão medular”. Verificou-se um bom enquadramento dos resultados com dados reais no estudo de simulação.
Resumo:
Numerose osservazioni astrofisiche e cosmologiche compiute a partire dagli anni '30 confermano che circa il 26% dell'Universo è costituito da materia oscura. Tale materia ha la particolarità di interagire solo gravitazionalmente e, forse, debolmente: essa si presenta massiva e neutra. Tra le numerose ipotesi avanzate riguardanti la natura della materia oscura una delle più accreditate è quella delle WIMP (Weakly Interacting Massive Particle). Il progetto all'avanguardia nella ricerca diretta delle WIMP è XENON presso i Laboratori Nazionali del Gran Sasso (LNGS). Tale esperimento è basato sulla diffusione elastica delle particelle ricercate su nuclei di Xeno: il rivelatore utilizzato è una TPC a doppia fase (liquido-gas). La rivelazione diretta di materia oscura prevede l'impiego di un rivelatore molto grande, a causa della piccola probabilità di interazione, e di ambienti a bassa radioattività naturale, per ridurre al minimo il rumore di fondo. Risulta necessario inoltre l'utilizzo di uno schermo attivo che individui particelle di alta energia, in particolare muoni cosmici, che possono produrre falsi segnali. È stato realizzato a tale scopo un sistema di Muon Veto composto da un grande cilindro d'acqua posto attorno alla TPC, equipaggiato con 84 fotorivelatori atti ad osservare i fotoni ottici emessi per effetto Čherenkov dai raggi cosmici. Il presente lavoro di tesi si colloca nell'ambito di un programma di simulazione Monte Carlo, creato per realizzare virtualmente l'esperimento XENON1T e per effettuare studi preliminari. Lo scopo di tale lavoro è stato quello di contribuire alla scrittura e alla verifica del codice di simulazione e allo studio di eventi di muoni cosmici da esso generati. L'analisi dati è stata effettuata scrivendo un programma in C++ in grado di analizzare i risultati forniti dal simulatore e di generare degli Event Display statici e dinamici per una visualizzazione efficace degli eventi.
Resumo:
I neutroni possono essere classificati in base all'energia e per anni lo studio sui neutroni si è focalizzato verso le basse energie, ottenendo informazioni fondamentali sulle reazioni nucleari. Lo studio per i neutroni ad alta energia (E >20 MeV) ha ultimamente suscitato un vivo interesse, poiché i neutroni hanno un ruolo fondamentale in una vasta gamma di applicazioni: in campo medico, industriale e di radioprotezione. Tuttavia le informazioni sperimentali (sezioni d'urto) in nostro possesso, in funzione dell'energia dei neutroni, sono limitate, considerando che richiedono la produzione di fasci con un ampio spettro energetico e delle tecniche di rivelazione conforme ad essi. La rivelazione dei neutroni avviene spesso attraverso il processo di scintillazione che consiste nell'eccitazione e diseccitazione delle molecole che costituiscono il rivelatore. Successivamente, attraverso i fotomoltiplicatori, la luce prodotta viene raccolta e convertita in impulsi energetici che vengono registrati ed analizzati. Lo scopo di questa tesi è quello di testare quale sia la migliore configurazione sperimentale di un rivelatore costituito da scintillatori e fotomoltiplicatori per quanto riguarda la raccolta di luce, utilizzando una simulazione Monte Carlo per riprodurre le proprietà ottiche di un rivelatore per misure di flusso di un rivelatore ad alta energia.
Resumo:
The Hybrid Monte Carlo algorithm is adapted to the simulation of a system of classical degrees of freedom coupled to non self-interacting lattices fermions. The diagonalization of the Hamiltonian matrix is avoided by introducing a path-integral formulation of the problem, in d + 1 Euclidean space–time. A perfect action formulation allows to work on the continuum Euclidean time, without need for a Trotter–Suzuki extrapolation. To demonstrate the feasibility of the method we study the Double Exchange Model in three dimensions. The complexity of the algorithm grows only as the system volume, allowing to simulate in lattices as large as 163 on a personal computer. We conclude that the second order paramagnetic–ferromagnetic phase transition of Double Exchange Materials close to half-filling belongs to the Universality Class of the three-dimensional classical Heisenberg model.
Resumo:
Ultracold gases provide an ideal platform for quantum simulations of many-body systems. Here we are interested in a particular system which has been the focus of most experimental and theoretical works on ultracold fermionic gases: the unitary Fermi gas. In this work we study with Quantum Monte Carlo simulations a two-component gas of fermionic atoms at zero temperature in the unitary regime. Specifically, we are interested in studying how the effective masses for the quasi-particles of the two components of the Fermi liquid evolve as the polarization is progressively reduced from full to lower values. A recent theoretical work, based on alternative diagrammatic methods, has indeed suggested that such effective masses should diverge at a critical polarization. To independently verify such predictions, we perform Variational Monte Carlo (VMC) calculations of the energy based on Jastrow-Slater wavefunctions after adding or subtracting a particle with a given momentum to a full Fermi sphere. In this way, we determine the quasi-particle dispersions, from which we extract the effective masses for different polarizations. The resulting effective masses turn out to be quite close to the non-interacting values, even though some evidence of an increase for the effective mass of the minority component appears close to the predicted value for the critical polarization. Preliminary results obtained for the majority component with the Fixed-node Diffusion Monte Carlo (DMC) method seem to indicate that DMC could lead to an increase of the effective masses in comparison with the VMC results. Finally, we point out further improvements of the trial wave-function and boundary conditions that would be necessary in future simulations to draw definite conclusions on the effective masses of the polarized unitary Fermi gas.
Resumo:
O elevado número de gestações na adolescência vem sendo vivenciado mundialmente, nos últimos anos, com predomínio em alguns países subdesenvolvidos e em desenvolvimento; em torno de 95% das gestações ocorrem entre os 15 e 19 anos. A saúde pública considera gravidez na adolescência uma das maiores preocupações por acarretar complicações obstétricas, com repercussões para a mãe e o recém-nascido, bem como problemas psicossociais e econômicos. O objetivo deste plano de ação é reduzir a incidência de gravidez na adolescência na área de abrangência da Equipe de Saúde da Família (ESF) Monte Carlo, município de Sete Lagoas, Minas Gerias. Para ajudar na construção da intervenção, além do diagnóstico situacional da área de abrangência da ESF, foram realizados levantamentos no banco de dados do Instituto Brasileiro de Geografia e Estatística (IBGE), na base de dados do Sistema de Informação da Atenção Básica (SIAB), e no site eletrônico do Departamento de Informática do Sistema Único de Saúde do Brasil (DATASUS), entre outros. Também, foi realizada busca de publicações sobre o tema nos bancos de dados da Biblioteca Virtual em Saúde (BVS): Scientific Electronic Library Online SCIELO) e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS); no Banco de Dados de Enfermagem (BDENF), e publicações do Ministério da Saúde. A busca de artigos foi guiada utilizando-se os seguintes Descritores em Ciências da Saúde (DeCS): Relações Familiares; Gravidez na Adolescência; Saúde do Adolescente; Estratégia Saúde da Família; e Planejamento em Saúde. O período de busca compreendeu trabalhos publicados entre 2005 e 2015, exceto legislações e outras publicações básicas anteriores. Para realização da intervenção foram utilizados os passos para elaboração de um plano de ação, descritos no Módulo de Planejamento e Avaliação das Ações de Saúde do Curso de especialização em Atenção Básica em Saúde da Família. Assim, atividades como palestras na unidade de saúde e nas escolas locais, oficinas de capacitação dos profissionais, rodas de conversa, grupos operativos, e visitas domiciliares constituem estratégias importantes para se trabalhar a prevenção da gravidez na adolescência, com os adolescentes e suas famílias
Resumo:
This article presents Monte Carlo techniques for estimating network reliability. For highly reliable networks, techniques based on graph evolution models provide very good performance. However, they are known to have significant simulation cost. An existing hybrid scheme (based on partitioning the time space) is available to speed up the simulations; however, there are difficulties with optimizing the important parameter associated with this scheme. To overcome these difficulties, a new hybrid scheme (based on partitioning the edge set) is proposed in this article. The proposed scheme shows orders of magnitude improvement of performance over the existing techniques in certain classes of network. It also provides reliability bounds with little overhead.
Resumo:
RESUMO: Este trabalho teve como objetivo a determinação de esquemas de tratamento alternativos para o carcinoma da próstata com radioterapia externa (EBRT) e braquiterapia de baixa taxa de dose (LDRBT) com implantes permanentes de Iodo-125, biologicamente equivalentes aos convencionalmente usados na prática clínica, com recurso a modelos teóricos e a métodos de Monte Carlo (MC). Os conceitos de dose biológica efetiva (BED) e de dose uniforme equivalente (EUD) foram utilizados, com o modelo linear-quadrático (LQ), para a determinação de regimes de tratamento equivalentes. Numa primeira abordagem, utilizou-se a BED para determinar: 1) esquemas hipofracionados de EBRT mantendo as complicações retais tardias de regimes convencionais com doses totais de 75,6 Gy, 77,4 Gy, 79,2 Gy e 81,0 Gy; e 2) a relação entre as doses totais de EBRT e LDRBT de modo a manter a BED do regime convencional de 45 Gy de EBRT e 110 Gy de LDRBT. Numa segunda abordagem, recorreu-se ao código de MC MCNPX para a simulação de distribuições de dose de EBRT e LDRBT em dois fantomas de voxel segmentados a partir das imagens de tomografia computorizada de pacientes com carcinoma da próstata. Os resultados das simulações de EBRT e LDRBT foram somados e determinada uma EUD total de forma a obterem-se: 1) esquemas equivalentes ao tratamento convencional de 25 frações de 1,8 Gy de EBRT em combinação com 110 Gy de LDRBT; e 2) esquemas equivalentes a EUD na próstata de 67 Gy, 72 Gy, 80 Gy, 90 Gy, 100 Gy e 110 Gy. Em todos os resultados nota-se um ganho terapêutico teórico na utilização de esquemas hipofracionados de EBRT. Para uma BED no reto equivalente ao esquema convencional, tem-se um aumento de 2% na BED da próstata com menos 5 frações. Este incremento dá-se de forma cada vez mais visível à medida que se reduz o número de frações, sendo da ordem dos 10-11% com menos 20 frações e dos 35-45% com menos 40 frações. Considerando os resultados das simulações de EBRT, obteve-se uma EUD média de 107 Gy para a próstata e de 42 Gy para o reto, com o esquema convencional de 110 Gy de LDRBT, seguidos de 25 frações de 1,8 Gy de EBRT. Em termos de probabilidade de controlo tumoral (igual EUD), é equivalente a este tratamento a administração de EBRT em 66 frações de 1,8 Gy, 56 de 2 Gy, 40 de 2,5 Gy, 31 de 3 Gy, 20 de 4 Gy ou 13 de 5 Gy. Relativamente à administração de 66 frações de 1,8 Gy, a EUD generalizada no reto reduz em 6% com o recurso a frações de 2,5 Gy e em 10% com frações de 4 Gy. Determinou-se uma BED total de 162 Gy para a administração de 25 frações de 1,8 Gy de EBRT em combinação com 110 Gy de LDRBT. Variando-se a dose total de LDRBT (TDLDRBT) em função da dose total de EBRT (TDEBRT), de modo a garantir uma BED de 162 Gy, obteve-se a seguinte relação:.......... Os resultados das simulações mostram que a EUD no reto diminui com o aumento da dose total de LDRBT para dose por fração de EBRT (dEBRT) inferiores a 2, Gy e aumenta para dEBRT a partir dos 3 Gy. Para quantidades de TDLDRBT mais baixas (<50 Gy), o reto beneficia de frações maiores de EBRT. À medida que se aumenta a TDLDRBT, a EUD generalizada no reto torna-se menos dependente da dEBRT. Este trabalho mostra que é possível a utilização de diferentes regimes de tratamento para o carcinoma da próstata com radioterapia que possibilitem um ganho terapêutico, quer seja administrando uma maior dose biológica com efeitos tardios constantes, quer mantendo a dose no tumor e diminuindo a toxicidade retal. A utilização com precaução de esquemas hipofracionados de EBRT, para além do benefício terapêutico, pode trazer vantagens ao nível da conveniência para o paciente e economia de custos. Os resultados das simulações deste estudo e conversão para doses de efeito biológico para o tratamento do carcinoma da próstata apresentam linhas de orientação teórica de interesse para novos ensaios clínicos. --------------------------------------------------ABSTRACT: The purpose of this work was to determine alternative radiotherapy regimens for the treatment of prostate cancer using external beam radiotherapy (EBRT) and low dose-rate brachytherapy (LDRBT) with Iodine-125 permanent implants which are biologically equivalent to conventional clinical treatments, by the use of theoretical models and Monte Carlo techniques. The concepts of biological effective dose (BED) and equivalent uniform dose (EUD), together with the linear-quadratic model (LQ), were used for determining equivalent treatment regimens. In a first approach, the BED concept was used to determine: 1) hypofractionated schemes of EBRT maintaining late rectal complications as with the conventional regimens with total doses of 75.6 Gy, 77.4 Gy, 79.2 Gy and 81.0 Gy; and 2) the relationship between total doses of EBRT and LDRBT in order to keep the BED of the conventional treatment of 45 Gy of EBRT and 110 Gy of LDRBT. In a second approach, the MC code MCNPX was used for simulating dose distributions of EBRT and LDRBT in two voxel phantoms segmented from the computed tomography of patients with prostate cancer. The results of the simulations of EBRT and LDRBT were added up and given an overall EUD in order to obtain: 1) equivalent to conventional treatment regimens of 25 fraction of 1.8 Gy of EBRT in combination with 110Gy of LDRBT; and 2) equivalent schemes of EUD of 67 Gy, 72 Gy, 80 Gy, 90 Gy, 100 Gy, and 110Gy to the prostate. In all the results it is noted a therapeutic gain using hypofractionated EBRT schemes. For a rectal BED equivalent to the conventional regimen, an increment of 2% in the prostate BED was achieved with less 5 fractions. This increase is visibly higher as the number of fractions decrease, amounting 10-11% with less 20 fractions and 35-45% with less 20 fractions. Considering the results of the EBRT simulations an average EUD of 107 Gy was achieved for the prostate and of 42 Gy for the rectum with the conventional scheme of 110 Gy of LDRBT followed by 25 fractions of 1.8 Gy of EBRT. In terms of tumor control probability (same EUD) it is equivalent to this treatment, for example, delivering the EBRT in 66 fractions of 1.8 Gy, 56 fractions of 2 Gy, 40 fractions of 2.5 Gy, 31 fractions of 3 Gy, 20 fractions of 4 Gy or 13 fractions of 5 Gy. Regarding the use of 66 fractions of 1.8 Gy, the rectum EUD is reduced to 6% with 2.5 Gy per fraction and to 10% with 4 Gy. A total BED of 162 Gy was achieved for the delivery of 25 fractions of 1.8 Gy of EBRT in combination with 110 Gy of LDRBT. By varying the total dose of LDRBT (TDLDRBT) with the total dose of EBRT (TDEBRT) so as to ensure a BED of 162 Gy, the following relationship was obtained: ....... The simulation results show that the rectum EUD decreases with the increase of the TDLDRBT, for EBRT dose per fracion (dEBRT) less than 2.5 Gy and increases for dEBRT above 3 Gy. For lower amounts of TDLDRBT (< 50Gy), the rectum benefits of larger EBRT fractions. As the TDLDRBT increases, the rectum gEUD becomes less dependent on the dEBRT. The use of different regimens which enable a therapeutic gain, whether deivering a higher dose with the same late biological effects or maintaining the dose to the tumor and reducing rectal toxicity is possible. The use with precaution of hypofractionated regimens, in addition to the therapeutic benefit, can bring advantages in terms of convenience for the patient and cost savings. The simulation results of this study together with the biological dose conversion for the treatment of prostate cancer serve as guidelines of interest for new clinical trials.
Resumo:
We provide methods for forecasting variables and predicting turning points in panel Bayesian VARs. We specify a flexible model which accounts for both interdependencies in the cross section and time variations in the parameters. Posterior distributions for the parameters are obtained for a particular type of diffuse, for Minnesota-type and for hierarchical priors. Formulas for multistep, multiunit point and average forecasts are provided. An application to the problem of forecasting the growth rate of output and of predicting turning points in the G-7 illustrates the approach. A comparison with alternative forecasting methods is also provided.