972 resultados para Mandibular gland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES/HYPOTHESIS Assess the diagnostic and prognostic relevance of intraglandular lymph node (IGLN) metastases in primary parotid gland carcinomas (PGCs). STUDY DESIGN Retrospective study at a tertiary referral university hospital. METHODS We reviewed the records of 95 patients with primary PGCs, treated at least surgically, between 1997 and 2010. We assessed the clinicopathological associations of IGLN metastases, their prognostic significance, and predictive value in the diagnosis of occult neck lymph node metastases RESULTS Twenty-four (25.26%) patients had IGLN metastases. This feature was significantly more prevalent in patients with advanced pT status (P = .01), pN status (P < .01), and overall stage (P < .001); high-risk carcinomas (P = .01); as well as in patients with treatment failures (P < .01). IGLN involvement was significantly associated with decreased univariate disease-free survival (P < .001). Positive and negative predictive values and accuracy for IGLN involvement in the detection of occult neck lymph node metastases were 63.64%, 90.48%, and 84.91%, respectively. The diagnostic values were generally higher in patients with low-risk subtype of PGCs. CONCLUSIONS IGLN involvement provides prognostic information and is associated with advanced tumoral stage and higher risk of recurrence. This feature could be used as a potential readout to determine whether a neck dissection in clinically negative neck lymph nodes is needed or not. LEVEL OF EVIDENCE 4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To compare the initial stability and stability after fatigue of three different locking systems (Synthes(®), Stryker(®) and Medartis(®)) for mandibular fixation and reconstruction. METHOD Standard mandible locking plates with identical profile height (1,5 mm), comparable length and screws with identical diameter (2,0 mm) were used. Plates were fixed with six screws according a preparation protocol. Four point bending tests were then performed using artificial bone material to compare their initial stability and failure limit under realistic loading conditions. Loading of the plates was performed using of a servo hydraulic driven testing machine. The stiffness of the implant/bone construct was calculated using a linear regression on the experimental data included in a range of applied moment between 2 Nm and 6 Nm. RESULTS No statistical difference in the elastic stiffness was visible between the three types of plate. However, differences were observed between the systems concerning the maximal load supported. The Stryker and Synthes systems were able to support a significantly higher moment. CONCLUSION For clinical application all systems show good and reliable results. Practical aspects such as handling, possible angulation of screw fixation, possibility of screw/plate removal, etc. may favour one or the other plating system.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION A prerequisite for development of gingival recession is the presence of alveolar bone dehiscence. Proclination of mandibular incisors can result in thinning of the alveolus and dehiscence formation. OBJECTIVE To assess an association between proclination of mandibular incisor and development of gingival recession. METHODS One hundred and seventeen subjects who met the following inclusion criteria were selected: 1. age 11-14 years at start of orthodontic treatment (TS), 2. bonded retainer placed immediately after treatment (T0), 3. dental casts and lateral cephalograms available pre-treatment (TS), post-treatment (T0), and 5 years post-treatment (T5), and 4. post-treatment (T0) lower incisor inclination (Inc_Incl) <95° or >100.5°. Two groups were formed: non-proclined (N = 57; mean Inc_Incl = 90.8°) and proclined (N = 60; mean Inc_Incl = 105.2°). Clinical crown heights of mandibular incisors and the presence of gingival recession sites in this region were assessed on plaster models. Fisher's exact tests, t-tests, and regression models were computed for analysis of inter-group differences. RESULTS The mean increase of clinical crown heights (from T0 to T5) of mandibular incisors ranged from 0.75 to 0.83mm in the non-proclined and proclined groups, respectively (P = 0.273). At T5, gingival recession sites were present in 12.3% and 11.7% patients from the non-proclined and proclined groups, respectively. The difference was also not significant (P = 0.851). CONCLUSIONS The proclination of mandibular incisors did not increase a risk of development of gingival recession during five-year observation in comparison non-proclined teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. PURPOSE To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. MATERIALS AND METHODS Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. RESULTS Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups. CONCLUSIONS Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION If a surgical approach is chosen to treat a multirooted tooth affected by persistent periapical pathosis, usually only the affected roots are operated on. The present study assessed the periapical status of the nonoperated root 5 years after apical surgery of the other root in mandibular molars. METHODS Patients treated with apical surgery of mandibular molars with a follow-up of 5 years were selected. Patient-related and clinical parameters (sex, age, smoking, symptoms, and signs of infection) before surgery were recorded. Preoperative intraoral periapical radiographs and radiographs 5 years after surgery were examined. The following data were collected: tooth, operated root, type and quality of the coronal restoration, marginal bone level, length and homogeneity of the root canal filling, presence of a post/screw, periapical index (PAI) of each root, and radiographic healing of the operated root. The presence of apical pathosis of the nonoperated root was analyzed statistically in relation to the recorded variables. RESULTS Thirty-seven patients fulfilled the inclusion criteria. Signs of periapical pathosis in the nonoperated root 5 years after surgery (PAI ≥ 3) could be observed in only 3 cases (8.1%). Therefore, statistical analysis in relation to the variables was not possible. The PAI of the nonoperated root before surgery had a weak correlation with signs of apical pathosis 5 years after surgery. CONCLUSIONS Nonoperated roots rarely developed signs of new apical pathosis 5 years after apical surgery of the other root in mandibular molars. It appears reasonable to resect and fill only roots with a radiographically evident periapical lesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic Resonance Imaging of the Pituitary Gland of Horses With Pituitary Pars Intermedia Dysfunction

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pineal gland is known to be light sensitive and to be involved in the seasonal reproduction of male golden hamster Mesocricetus auratus. In general, the pineal gland has been demonstrated to be inhibitory to the reproductive system of the male golden hamster. Melatonin is a pineal hormone which can mimic the action of the pineal gland upon the reproductive system. However, the actual site(s) of melatonin action in the hamster has not been demonstrated. In this study a direct effect of melatonin on the release of FSH and LH from superfused hamster pituitary glands was investigated.^ The superfused pituitary glands showed a stable in vitro basal release of FSH and LH for up to 10 hours. The superfused pituitaries demonstrated reproducible responses to repeated pulses of 10('-8) M LHRH, and a dose-dependent response to stimulation with different concentrations of LHRH.^ Melatonin inhibited the basal release of FSH and LH from superfused hamster pituitary glands. This effect of melatonin was specific and not a general indolamine or catecholamine effect.^ The superfused pituitaries had a diurnal differential responsiveness to physiological concentrations of melatonin with respect to FSH and LH release which were related to the light cycle used to maintain the experimental animals. A LD 14:10 photoperiod cycle was used with light on from 5 a.m. till 7 p.m.. With pituitary glands obtained at 8:30 a.m., the basal release of FSH exhibited an initial inhibition, a gradual rebound at approximately two hours after the beginning of melatonin superfusion, and a significant overshoot of FSH release after the cessation of infusion with melatonin (Morning Response). If the pituitary glands were obtained from hamsters which were sacrificed at 3:30 p.m., the release rate of FSH exhibited an inhibition during the entire period of melatonin infusion with a rebound effect appearing only after melatonin infusion was discontinued (Afternoon Response). There was no significant difference in the responsiveness of the pituitary gland to infusion with melatonin at either 8:30 a.m. or 3:30 p.m. with respect to LH release. Also, melatonin could not inhibit the gonadotropins response to continuous superfusion with 10('-9) M LHRH in pituitaries obtained at either 8:30 a.m. or 3:30 p.m., nor inhibit the stimulatory effect of pulsatile 10('-9) M LHRH. . . . (Author's abstract exceeds stipulated maximum length. Discontinued here with permission of author.) UMI^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Submitted in partial fulfillment of the requirements for a Certificate in Orthodontics, Dept. of Orthodontics, University of Connecticut Health Center, 1977

Relevância:

20.00% 20.00%

Publicador: