980 resultados para MODIFIED HODGE TEST


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modification of the indirect fluorescence test (IFT) for serological diagnosis of Paracoccidioidomycosis is described in which formolized budding forms (yeast cells) of the fungus Paracoccidioides brasiliensis are used as antigen. A further modification introduced is a less eiaborate technical procedure of the test without lowering the sensitivity of the reaction. The test may be considered as adequateiy accurate and easy to perform in any laboratory with immunofluorescence facilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A direct immunofluorescent antibody (DIFMA) test using a Leishmania genus- specific monoclonal antibody was evaluated in the routine diagnosis of cutaneous leishmaniasis (CL) in Ecuador. This test was compared with the standard diagnostic techniques of scrapings, culture and histology. Diagnostic samples were taken from a total of 90 active dermal ulcers from patients from areas of Ecuador known to be endemic for cutaneous leishmaniasis. DIFMA was positive in all lesions. It was shown to be significantly superior to standard diagnostic methods either alone or in combination. The sensitivity of DIFMA did not diminish with chronicity of lesions. This test proved to be extremely useful in the routine diagnosis of CL because it is highly sensitive, is easy to use and produces rapid results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a rapid method for the flow cytometric quantitation of phagocytosis in heparinized complete peripherial blood (HCPB), using commercially available phycoerythrin-conjugated latex particles of 1µm diameter. The method is faster and shows greater reproducibility than Bjerknes' (1984) standard technique using propidium iodide-stained Candida albicans, conventionally applied to the leukocytic layer of peripherial blood but here modified for HCPB. We also report a modification of Bjerknes' Intracellular Killing Test to allow its application to HCPB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forty voluntary blood donors from two different blood banks in Havana, Cuba, who were repeatedly reactive on the routine screening of antibodies to hepatitis C virus, by Umelisa HCV test, were analyzed for the presence of HCV RNA using a nested PCR assay of the HCV 5' untranslated region, Umelosa HCV qualitative. Sera from 45 patients of a specialized gastroenterology consultation, positive to Umelisa HCV, were also assayed with the Umelosa HCV qualitative, to establish their condition related to the presence of HCV RNA previously to the indication of a treatment or after three, six or twelve months of antiviral therapy. Serum HCV-RNA was detected in 21/40 (52.5%) donors who had repeatedly positive ELISA results, confirming the HCV infection for them. In specialized consultation HCV-RNA was detected by PCR analysis in 30/45 (66%) analyzed sera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ligase chain reaction DNA amplification method for direct detection of Mycobacterium tuberculosis (Abbott LCx MTB) in respiratory specimens was evaluated. Results from LCx MTB Assay were compared with those from acid fast bacilli smear, culture, and final clinical diagnosis for each patient. A total of 297 respiratory specimens (sputum and bronchial lavage) from 193 patients were tested. The sensitivity, specificity, positive predictive value and negative predictive value of LCx vs culture were 92.7%, 93%, 67.8% and 98.7%, respectively. When compared to the clinical final diagnosis, the sensitivity, specificity, PPV and NPV for LCx were 88.9%, 96.8%, 86.5% and 97.4%, respectively. The sensitivity of LCx MTB assay was 75% for smear-negative, culture positive samples. The results indicate that LCx MTB assay is a rapid, simple and valuable technique as a complementary tool for the diagnosis of tuberculosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the second-generation OptiMal test for malaria diagnosis under various storage conditions. It detected all the positive samples, except for two Plasmodium malariae samples. Further research evaluating diverse environmental conditions are important for ICT test applicability in Brazilian malaria areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented in this thesis was developed in collaboration with a Portuguese company, BeyonDevices, devoted to pharmaceutical packaging, medical technology and device industry. Specifically, the composition impact and surface modification of two polymeric medical devices from the company were studied: inhalers and vaginal applicators. The polyethylene-based vaginal applicator was modified using supercritical fluid technology to acquire self-cleaning properties and prevent the transport of bacteria and yeasts to vaginal flora. For that, in-situ polymerization of 2-substituted oxazolines was performed within the polyethylene matrix using supercritical carbon dioxide. The cationic ring-opening polymerization process was followed by end-capping with N,N-dimethyldodecylamine. Furthermore, for the same propose, the polyethylene matrix was impregnated with lavender oil in supercritical medium. The obtained materials were characterized physical and morphologically and the antimicrobial activity against bacteria and yeasts was accessed. Materials modified using 2-substituted oxazolines showed an effective killing ability for all the tested microorganisms, while the materials modified with lavender oil did not show antimicrobial activity. Only materials modified with oligo(2-ethyl-2-oxazoline) maintain the activity during the long term stability. Furthermore, the cytotoxicity of the materials was tested, confirming their biocompatibilty. Regarding the inhaler, its surface was modified in order to improve powder flowability and consequently, to reduce powder retention in the inhaler´s nozzle. New dry powder inhalers (DPIs), with different needle’s diameters, were evaluated in terms of internal resistance and uniformity of the emitted dose. It was observed that they present a mean resistance of 0.06 cmH2O0.5/(L/min) and the maximum emitted dose obtained was 68.9% for the inhaler with higher needle´s diameter (2 mm). Thus, this inhaler was used as a test and modified by the coating with a commonly-used force control agent, magnesium stearate, dried with supercritical carbon dioxide (scCO2) and the uniformity of delivered dose tests were repeated. The modified inhaler showed an increase in emitted dose from 68.9% to 71.3% for lactose and from 30.0% to 33.7% for Foradil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Bioorgânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the performance of the immunochromatographic test for filariasis, adult Wuchereria bancrofti worms were incubated under different conditions. The tests were strongly positive with incubation fluids from both living and mechanically damaged females. Negative results were observed with incubation fluids from all male worms and from intact dead females.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Latent tuberculosis was studied in a research laboratory. A prevalence of positive tuberculin skin test results (> 15mm) of 20% was found and the main predictors were place of birth in a foreign country with high prevalence of tuberculosis and a history of contact with patients with untreated active tuberculosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: HTLV-1/2 screening among blood donors commonly utilizes an enzyme-linked immunosorbent assay (EIA), followed by a confirmatory method such as Western blot (WB) if the EIA is positive. However, this algorithm yields a high rate of inconclusive results, and is expensive. METHODS: Two qualitative real-time PCR assays were developed to detect HTLV-1 and 2, and a total of 318 samples were tested (152 blood donors, 108 asymptomatic carriers, 26 HAM/TSP patients and 30 seronegative individuals). RESULTS: The sensitivity and specificity of PCR in comparison with WB results were 99.4% and 98.5%, respectively. PCR tests were more efficient for identifying the virus type, detecting HTLV-2 infection and defining inconclusive cases. CONCLUSIONS: Because real-time PCR is sensitive and practical and costs much less than WB, this technique can be used as a confirmatory test for HTLV in blood banks, as a replacement for WB.