829 resultados para Liquid based cytology


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This PhD work is focused on liquid crystal based tunable phase devices with special emphasis on their design and manufacturing. In the course of the work a number of new manufacturing technologies have been implemented in the UPM clean room facilities, leading to an important improvement in the range of devices being manufactured in the laboratory. Furthermore, a number of novel phase devices have been developed, all of them including novel electrodes, and/or alignment layers. The most important manufacturing progress has been the introduction of reactive ion etching as a tool for achieving high resolution photolithography on indium-tin-oxide (ITO) coated glass and quartz substrates. Another important manufacturing result is the successful elaboration of a binding protocol of anisotropic conduction adhesives. These have been employed in high density interconnections between ITO-glass and flexible printed circuits. Regarding material characterization, the comparative study of nonstoichiometric silicon oxide (SiOx) and silica (SiO2) inorganic alignment layers, as well as the relationship between surface layer deposition, layer morphology and liquid crystal electrooptical response must be highlighted, together with the characterization of the degradation of liquid crystal devices in simulated space mission environment. A wide variety of phase devices have been developed, with special emphasis on beam steerers. One of these was developed within the framework of an ESA project, and consisted of a high density reconfigurable 1D blaze grating, with a spatial separation of the controlling microelectronics and the active, radiation exposed, area. The developed devices confirmed the assumption that liquid crystal devices with such a separation of components, are radiation hard, and can be designed to be both vibration and temperature sturdy. In parallel to the above, an evenly variable analog beam steering device was designed, manufactured and characterized, providing a narrow cone diffraction free beam steering. This steering device is characterized by a very limited number of electrodes necessary for the redirection of a light beam. As few as 4 different voltage levels were needed in order to redirect a light beam. Finally at the Wojskowa Akademia Techniczna (Military University of Technology) in Warsaw, Poland, a wedged analog tunable beam steering device was designed, manufactured and characterized. This beam steerer, like the former one, was designed to resist the harsh conditions both in space and in the context of the shuttle launch. Apart from the beam steering devices, reconfigurable vortices and modal lens devices have been manufactured and characterized. In summary, during this work a large number of liquid crystal devices and liquid crystal device manufacturing technologies have been developed. Besides their relevance in scientific publications and technical achievements, most of these new devices have demonstrated their usefulness in the actual work of the research group where this PhD has been completed. El presente trabajo de Tesis se ha centrado en el diseño, fabricación y caracterización de nuevos dispositivos de fase basados en cristal líquido. Actualmente se están desarrollando dispositivos basados en cristal líquido para aplicaciones diferentes a su uso habitual como displays. Poseen la ventaja de que los dispositivos pueden ser controlados por bajas tensiones y no necesitan elementos mecánicos para su funcionamiento. La fabricación de todos los dispositivos del presente trabajo se ha realizado en la cámara limpia del grupo. La cámara limpia ha sido diseñada por el grupo de investigación, es de dimensiones reducidas pero muy versátil. Está dividida en distintas áreas de trabajo dependiendo del tipo de proceso que se lleva a cabo. La cámara limpia está completamente cubierta de un material libre de polvo. Todas las entradas de suministro de gas y agua están selladas. El aire filtrado es constantemente bombeado dentro de la zona limpia, a fin de crear una sobrepresión evitando así la entrada de aire sin filtrar. Las personas que trabajan en esta zona siempre deben de estar protegidas con un traje especial. Se utilizan trajes especiales que constan de: mono, máscara, guantes de látex, gorro, patucos y gafas de protección UV, cuando sea necesario. Para introducir material dentro de la cámara limpia se debe limpiar con alcohol y paños especiales y posteriormente secarlos con nitrógeno a presión. La fabricación debe seguir estrictamente unos pasos determinados, que pueden cambiar dependiendo de los requerimientos de cada dispositivo. Por ello, la fabricación de dispositivos requiere la formulación de varios protocolos de fabricación. Estos protocolos deben ser estrictamente respetados a fin de obtener repetitividad en los experimentos, lo que lleva siempre asociado un proceso de fabricación fiable. Una célula de cristal líquido está compuesta (de forma general) por dos vidrios ensamblados (sándwich) y colocados a una distancia determinada. Los vidrios se han sometido a una serie de procesos para acondicionar las superficies internas. La célula se llena con cristal líquido. De forma resumida, el proceso de fabricación general es el siguiente: inicialmente, se cortan los vidrios (cuya cara interna es conductora) y se limpian. Después se imprimen las pistas sobre el vidrio formando los píxeles. Estas pistas conductoras provienen del vidrio con la capa conductora de ITO (óxido de indio y estaño). Esto se hace a través de un proceso de fotolitografía con una resina fotosensible, y un desarrollo y ataque posterior del ITO sin protección. Más tarde, las caras internas de los vidrios se acondicionan depositando una capa, que puede ser orgánica o inorgánica (un polímero o un óxido). Esta etapa es crucial para el funcionamiento del dispositivo: induce la orientación de las moléculas de cristal líquido. Una vez que las superficies están acondicionadas, se depositan espaciadores en las mismas: son pequeñas esferas o cilindros de tamaño calibrado (pocos micrómetros) para garantizar un espesor homogéneo del dispositivo. Después en uno de los sustratos se deposita un adhesivo (gasket). A continuación, los sustratos se ensamblan teniendo en cuenta que el gasket debe dejar una boca libre para que el cristal líquido se introduzca posteriormente dentro de la célula. El llenado de la célula se realiza en una cámara de vacío y después la boca se sella. Por último, la conexión de los cables a la célula y el montaje de los polarizadores se realizan fuera de la sala limpia (Figura 1). Dependiendo de la aplicación, el cristal líquido empleado y los demás componentes de la célula tendrán unas características particulares. Para el diseño de los dispositivos de este trabajo se ha realizado un estudio de superficies inorgánicas de alineamiento del cristal líquido, que será de gran importancia para la preparación de los dispositivos de fase, dependiendo de las condiciones ambientales en las que vayan a trabajar. Los materiales inorgánicos que se han estudiado han sido en este caso SiOx y SiO2. El estudio ha comprendido tanto los factores de preparación influyentes en el alineamiento, el comportamiento del cristal líquido al variar estos factores y un estudio de la morfología de las superficies obtenidas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we report the experimental results obtained when an He-Ne laser beam crosses an MBBA homeotropic sandwich structure and is modulated by the influence of another laser beam, in our case an Ar+ laser, crossing through the same region. We extend some results previously reported by us1 2 concerning the influence of the ratio of the diameters of the laser beams on the modulation characteristics. A theoretical model, based on the one reported in Ref6 , shows good agreement with the experimental results. If the Ar+ laser is intensity chopped, the resulting He-Ne diffracted image is also intensity modulated. The highest frequency observed has been 500 p. p. s.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports a new family of multimode fiber-optic switching devices based on nematic liquid crystal devices reported by us previously. These devices have a wedged structure as the main characteristic. Several modes of behavior cart arise depending on the internal configuration of the molecules. As we show, fhey have the possibility of total switching of unpolarized light with a very simple structure, low insertion losses, and very low operating voltages These new devices should find a wide range of applications in fiber-optic communication systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Los métodos de detección rápida de microorganismos se están convirtiendo en una herramienta esencial para el control de calidad en el área de la biotecnología, como es el caso de las industrias de alimentos y productos farmacéuticos y bioquímicos. En este escenario, el objetivo de esta tesis doctoral es desarrollar una técnica de inspección rápida de microoganismos basada en ultrasonidos. La hipótesis propuesta es que la combinación de un dispositivo ultrasónico de medida y un medio líquido diseñado específicamente para producir y atrapar burbujas, pueden constituir la base de un método sensible y rápido de detección de contaminaciones microbianas. La técnica presentada es efectiva para bacterias catalasa-positivas y se basa en la hidrólisis del peróxido de hidrógeno inducida por la catalasa. El resultado de esta reacción es un medio con una creciente concentración de burbujas. Tal medio ha sido estudiado y modelado desde el punto de vista de la propagación ultrasónica. Las propiedades deducidas a partir del análisis cinemático de la enzima se han utilizado para evaluar el método como técnica de inspección microbiana. En esta tesis, se han investigado aspectos teóricos y experimentales de la hidrólisis del peróxido de hidrógeno. Ello ha permitido describir cuantitativamente y comprender el fenómeno de la detección de microorganismos catalasa-positivos mediante la medida de parámetros ultrasónicos. Más concretamente, los experimentos realizados muestran cómo el oxígeno que aparece en forma de burbujas queda atrapado mediante el uso de un gel sobre base de agar. Este gel fue diseñado y preparado especialmente para esta aplicación. A lo largo del proceso de hidrólisis del peróxido de hidrógeno, se midió la atenuación de la onda y el “backscattering” producidos por las burbujas, utilizando una técnica de pulso-eco. Ha sido posible detectar una actividad de la catalasa de hasta 0.001 unidades/ml. Por otra parte, este estudio muestra que por medio del método propuesto, se puede lograr una detección microbiana para concentraciones de 105 células/ml en un periodo de tiempo corto, del orden de unos pocos minutos. Estos resultados suponen una mejora significativa de tres órdenes de magnitud en comparación con otros métodos de detección por ultrasonidos. Además, la sensibilidad es competitiva con modernos y rápidos métodos microbiológicos como la detección de ATP por bioluminiscencia. Pero sobre todo, este trabajo muestra una metodología para el desarrollo de nuevas técnicas de detección rápida de bacterias basadas en ultrasonidos. ABSTRACT In an industrial scenario where rapid microbiological methods are becoming essential tools for quality control in the biotechnological area such as food, pharmaceutical and biochemical; the objective of the work presented in this doctoral thesis is to develop a rapid microorganism inspection technique based on ultrasounds. It is proposed that the combination of an ultrasonic measuring device with a specially designed liquid medium, able to produce and trap bubbles could constitute the basis of a sensitive and rapid detection method for microbial contaminations. The proposed technique is effective on catalase positive microorganisms. Well-known catalase induced hydrogen peroxide hydrolysis is the fundamental of the developed method. The physical consequence of the catalase induced hydrogen peroxide hydrolysis is an increasingly bubbly liquid medium. Such medium has been studied and modeled from the point of view of ultrasonic propagation. Properties deduced from enzyme kinematics analysis have been extrapolated to investigate the method as a microbial inspection technique. In this thesis, theoretical and experimental aspects of the hydrogen peroxide hydrolysis were analyzed in order to quantitatively describe and understand the catalase positive microorganism detection by means of ultrasonic measurements. More concretely, experiments performed show how the produced oxygen in form of bubbles is trapped using the new gel medium based on agar, which was specially designed for this application. Ultrasonic attenuation and backscattering is measured in this medium using a pulse-echo technique along the hydrogen peroxide hydrolysis process. Catalase enzymatic activity was detected down to 0.001 units/ml. Moreover, this study shows that by means of the proposed method, microbial detection can be achieved down to 105 cells/ml in a short time period of the order of few minutes. These results suppose a significant improvement of three orders of magnitude compared to other ultrasonic detection methods for microorganisms. In addition, the sensitivity reached is competitive with modern rapid microbiological methods such as ATP detection by bioluminescence. But above all, this work points out a way to proceed for developing new rapid microbial detection techniques based on ultrasound.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we report a new metod for optical switching based on the magneto-optical properties of liquid crystal materials. In order to improve previous response times, we used a wedge structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this letter , we report a new method for óptical switching based on the electro-optical properties of liquid crystal materials and, in particular, of the nematic type. The basis of this new method is the use of twisted wedge structure that has not been reported before elsewhere. In the past several years , great efforts in integrated optics have been made to develop optical switching devices with fast speed by using electro-optic, acousto-optic or magneto -optic materials. A mechanically operated óptical switch made of grade-index rod 1enses and e1ectromagnets has been proposed too . Switches of this kind include one input and two output waveguides and, depending on the app1ied voltage, one incident light on the switch exits either in one or another of the two output waveguides.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work a novel point diffraction interferometer based on a variable liquid crystal wave plate (LCWP) has been implemented. The LCWP consists of a 3x3 cm2 monopixel cell with parallel alignment. The monopixel cell was manufactured such that the electrode covers the entire surface except in a centered circular area of 50 μm of diameter. This circle acts as a point perturbation which diffracts the incident wave front giving rise to a spherical reference wave. By applying a voltage to the LCWP we can change the phase of the wave front that passes through the monopixel, except at the center. Phase shifting techniques are used in order to calculate the amplitude and phase distribution of the object wave front. The system allows a digital hologram to be obtained, and by using the Fresnel diffraction integral it is possible to digitally reconstruct the different planes that constitute the three dimensional object.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we present a novel interferometer based on liquid crystal and photonic crystal fiber technology. The objective of this project is the development of a tunable (switchable) modal (Mach-Zehnder) interferometer for optical communications or sensing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we present a novel interferometer based on liquid crystal and photonic crystal fiber technology. The objective of this project is the development of a tunable (switchable) modal (Mach-Zehnder) interferometer for optical communications or sensing. This interferometer has been manufactured splicing a short portion (between 15 and 30 mm) of photonic crystal fiber with two single mode fiber pigtails. The study shows a high sensitivity of the interferometer to the polarization of the launching light.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper the dynamics of axisymmetric, slender, viscous liquid bridges having volume close to the cylindrical one, and subjected to a small gravitational field parallel to the axis of the liquid bridge, is considered within the context of one-dimensional theories. Although the dynamics of liquid bridges has been treated through a numerical analysis in the inviscid case, numerical methods become inappropriate to study configurations close to the static stability limit because the evolution time, and thence the computing time, increases excessively. To avoid this difficulty, the problem of the evolution of these liquid bridges has been attacked through a nonlinear analysis based on the singular perturbation method and, whenever possible, the results obtained are compared with the numerical ones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed new analytical expressions for designing liquid crystal (LC) microlenses. These equations are based on a novel equivalent electric circuit and can be used to create an optimum design for the LC lenses in which the lens diameter ranges from a few micrometers to several millimeters. Thus far, only experimental studies have been conducted on the LC lenses. The analytical expressions developed in this letter depend on various manufacturing parameters and can be used to design lenses with specific focal lengths and a parabolic phase profile. The required driving scheme (modal or hole-patterned) can be predicted. The LC microlenses were manufactured and electrooptically characterized: the measurements were compared using an analytical approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the theory, design, applications and performance of a new Reconfigurable Add-drop Multiplexer (ROADM) with flexible bandwidth allocation. The device can address several wavelengths at the input to four output fibers, according to the holograms stored in a SLM (Spatial Light Modulator), where all the outputs are equalized in power. All combinations of the input wavelengths are possible at the different output fibers. Each fiber has assigned all the signals with the same bandwidth; the possible bandwidths are 12.5GHz, 25GHz, 50GHz and 100GHz, according to ITU-T 694.1 Recommendation. It is possible to route several signals with different bandwidth in real time thanks to Liquid Crystal over Silicon (LCoS) technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel temperature sensor based on nematic liquid crystal permittivity as a sensing magnitude, is presented. This sensor consists of a specific micrometric structure that gives considerable advantages from other previous related liquid crystal (LC) sensors. The analytical study reveals that permittivity change with temperature is introduced in a hyperbolic cosine function, increasing the sensitivity term considerably. The experimental data has been obtained for ranges from −6 °C to 100 °C. Despite this, following the LC datasheet, theoretical ranges from −40 °C to 109 °C could be achieved. These results have revealed maximum sensitivities of 33 mVrms/°C for certain temperature ranges; three times more than of most silicon temperature sensors. As it was predicted by the analytical study, the micrometric size of the proposed structure produces a high output voltage. Moreover the voltage’s sensitivity to temperature response can be controlled by the applied voltage. This response allows temperature measurements to be carried out without any amplification or conditioning circuitry, with very low power consumption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the design and experimental characterization of a tunable microstrip bandpass filter based on liquid crystal technology are presented. A reshaped microstrip dual-mode filter structure has been used in order to improve the device performance. Specifically, the aim is to increase the pass-band return loss of the filter by narrowing the filter bandwidth. Simulations confirm the improvement of using this new structure, achieving a pass-band return loss increase of 1.5 dB at least. Because of the anisotropic properties of LC molecules, a filter central frequency shift from 4.688 GHz to 5.045 GHz, which means a relative tuning range of 7.3%, is measured when an external AC voltage from 0 Vrms to 15 Vrms is applied to the device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El presente trabajo de Tesis se ha centrado en el diseño, fabricación y caracterización de dispositivos basados en fibras de cristal fotónico infiltrado selectivamente con cristales líquidos, polímeros y una mezcla de ambos. Todos los dispositivos son sintonizables, y su área de aplicación se centra en comunicaciones ópticas y sensores. La manipulación y fusionado de fibras fotónicas, el llenado selectivo de determinadas cavidades y la alineación recíproca de fibras mantenedoras de polarización son tareas muy específicas y delicadas para las que se requieren protocolos muy estrictos. Previo a la fabricación de dispositivos ha sido necesaria por tanto una tarea de sistematización y creación de protocolos de fabricación. Una vez establecidos se ha procedido a la fabricación y caracterización de dispositivos. Los dispositivos fabricados se enumeran a continuación para posteriormente detallar una a una las singularidades de cada uno. • Interferómetros intermodales hechos a partir de una porción de fibra fotónica soldada entre dos fibras estándar, bien monomodo o PANDA (mantenedora de polarización). Estos interferómetros han sido sumergidos o bien llenados selectivamente con cristales líquidos para así sintonizar la señal interferométrica guiada a través de la fibra. • Infiltración de fibras fotónicas con cristales líquidos colestéricos con especial énfasis en la fase azul (blue phase) de estos materiales. Las moléculas de cristal líquido se autoalinean en volumen por lo que la infiltración de fibras fotónicas con estos cristales líquidos es muy interesante, pues es conocida la dificultad de alinear apropiadamente cristales líquidos dentro de cavidades micrométricas de las fibras fotónicas. • Grabación de redes holográficas de forma selectiva en las cavidades de una fibra fotónica. Estas redes holográficas, llamadas POLICRYPS (POlymer-LIquid CRYstal-Polymer Slices), son redes fabricadas a base de franjas de polímero y cristal líquido alineado perpendicularmente a dichas franjas. Las franjas son a su vez perpendiculares al eje de la fibra como lo puede ser una red de Bragg convencional. El cristal líquido, al estar alineado perpendicularmente a dichos franjas y paralelo al eje de la fibra, se puede conmutar aplicando un campo eléctrico externo, modificando así el índice efectivo de la red. Se puede fabricar por lo tanto una red de Bragg sintonizable en fibra, muy útil en comunicaciones ópticas. • Llenado selectivo de fibras fotónicas con polidimetilsiloxano (PDMS), un polímero de tipo silicona. Si se realiza un llenado selectivo asimétrico se puede inducir birrefringencia en la fibra. El índice de refracción del PDMS tiene una fuerte dependencia térmica, por lo que se puede sintonizar la birrefringencia de la fibra. • Estudio teórico de llenado selectivo de fibras fotónicas con PDMS dopado con nanopartículas de plata de 5, 40 y 80 nm. Estas nanopartículas poseen un pico de absorción en torno a los 450 nm debido a resonancias superficiales localizadas de plasmones (LSPR). La resonancia del plasmon tiene una fuerte dependencia con el índice de refracción del material colindante, y al ser éste PDMS, la variación de índice de refracción se ve amplificada, obteniendo una absorción sintonizable. Se ha propuesto la fabricación de polarizadores sintonizables usando esta técnica. Como ya se ha dicho, previamente a la fabricación ha sido necesaria la protocolización de diversos procedimientos de fabricación de alta complejidad, así como protocolizar el proceso de toma de medidas para optimizar los resultados. Los procedimientos que han requerido la formulación de protocolos específicos han sido los siguientes: • Llenado selectivo de cavidades en una fibra fotónica. Dichas fibras tienen generalmente un diámetro externo de 125 μm, y sus cavidades son de entre 5 y 10 μm de diámetro. Se han desarrollado tres técnicas diferentes para el llenado/bloqueado selectivo, pudiéndose combinar varios protocolos para la optimización del proceso. Las técnicas son las siguientes: o Llenado y bloqueado con un prepolímero. Dicho prepolímero, también llamado adhesivo óptico, está inicialmente en estado líquido y posee una cierta viscosidad. Las cavidades de la fibra fotónica que se desea llenar o bloquear poseen un diámetro diferente al resto, por lo que en el proceso de llenado aparecen dos frentes de llenado dependientes de su diámetro. A mayor diámetro, mayor velocidad de llenado. Polimerizando cuando existe dicha diferencia en los frentes se puede cortar por medio, obteniendo así una fibra parcialmente bloqueada. o Colapsamiento de las cavidades de menor diámetro mediante aplicación de calor. El calor producido por un arco voltaico de una soldadora de fibra estándar fusiona el material exterior de la fibra produciendo el colapsamiento de las cavidades de menor diámetro. En esta técnica también es necesaria una diferencia de diámetros en las cavidades de la fibra. o Bloqueo una a una de las cavidades de la fibra fotónica con adhesivo óptico. Este procedimiento es muy laborioso y requiere mucha precisión. Con este sistema se pueden bloquear las cavidades deseadas de una fibra sin importar su diámetro. • Alineación de una fuente de luz linealmente polarizada con una fibra mantenedora de polarización ya sea PANDA o fotónica. Así mismo también se han alineado entre sí fibras mantenedoras de polarización, para que sus ejes rápidos se fusionen paralelos y así el estado de polarización de la luz guiada se mantenga. • Sistematización de toma de medidas para caracterizar los interferómetros modales. Éstos son altamente sensibles a diversas variables por lo que el proceso de medida es complejo. Se deben aislar variables de forma estrictamente controlada. Aunque todos los dispositivos tienen en común el llenado selectivo de cavidades en una fibra fotónica cada dispositivo tiene sus peculiaridades, que van a ser explicadas a continuación. ABSTRACT The present Thesis has been centered in the design, fabrication and characterization of devices based on photonic crystal fibers selectively filled with liquid crystals, polymers and a mixture of both. All devices are tunable and their work field is optical communications and sensing The handling and splicing of photonic crystal fibers, the selective filling of their holes and the aligning of polarization maintaining fibers are very specific and delicate tasks for which very strict protocols are required. Before the fabrication of devices has therefore been necessary task systematization and creation of manufacturing protocols. Once established we have proceeded to the fabrication and characterization of devices. The fabricated devices are listed below and their peculiarities are detailed one by one: • Intermodal interferometers made with a portion of photonic crystal fiber spliced between two optical communication fiber pigtails, either single mode or PANDA (polarization-maintaining) fiber. These interferometers have been submerged or selectively filled with liquid crystals to tune the interferometric guided signal. • Infiltration of photonic fibers with cholesteric liquid crystals with special emphasis on their blue phase (blue phase). The liquid crystal molecules are self-aligning in volume so the infiltration of photonic fibers with these liquid crystals is very interesting. It is notoriously difficult to properly align liquid crystals within micron cavities such as photonic fibers. • Selectively recording of holographic gratings in the holes of photonic crystal fibers. These holographic gratings, called POLICRYPS (POlymer-LIquid CRYstal-Polymes Slices), are based on walls made of polymer and liquid crystal aligned perpendicular to them. These walls are perpendicular to the axis of the fiber as it can be a conventional Bragg grating. The liquid crystal is aligned perpendicular to the walls and parallel to the fiber axis, and can be switched by applying an external electric field and thus change the effective index of the grating. It is thus possible to manufacture a tunable Bragg grating fiber, useful in optical communications. •Asymmetrically selective filling of photonic crystal fibers with a silicone polymer like called polydimethylsiloxane (PDMS) to induce birefringence in the fiber. The refractive index of PDMS has temperature dependence, so that the birefringence of the fiber can be tuned. • Theoretical study of photonic crystal fibers selectively filled with PDMS doped with silver nanoparticles of 5, 40 and 80 nm. These nanoparticles have an absorption peak around 450 nm due to localized surface plasmon resonances (LSPR). Plasmon resonance has a strong dependence on the refractive index of the adjacent material, and as this is PDMS, the refractive index variation is amplified, obtaining a tunable absorption. Fabrication of tunable polarizers using this technique has been proposed. Before starting the fabrication, it has been necessary to optimize several very delicate procedures and different protocols have been designed. The most delicate procedures are as follows: • Selective filling of holes in a photonic crystal fiber. These fibers generally have an outer diameter of 125 μm, and their holes have a diameter around between 5 and 10 μm. It has been developed three different techniques for filling / selective blocking, and they can be combined for process optimization. The techniques are: o Filling and blocked with a prepolymer. This prepolymer also called optical adhesive is initially in liquid state and has a certain viscosity. The holes of the photonic crystal fiber that are desired to be filled or blocked should have a different diameter, so that in the filling process appear two different fronts depending on the hole diameter. The holes with larger diameter are filled faster. Then the adhesive is polymerized when there is such a difference on the front. A partially blocked fiber is obtained cutting between fronts. o Collapsing of holes of smaller diameter by application of heat. The heat produced by an arc of a standard fusion splicer fuses the outer fiber material producing the collapsing of the cavities of smaller diameter. In this technique also you need a difference of diameters in the fiber holes. o Blocking one by one the holes of photonic crystal fiber with optical adhesive. This procedure is very laborious and requires great precision. This system can block unwanted cavities regardless fiber diameter. • Aligning a linearly polarized light source with a polarization-maintaining fiber (either a PANDA fiber as a photonic crystal fiber). It is needed also an aligning between polarization-maintaining fibers, so that their fast axes parallel merge and that is state of polarization of light guided is maintained. • Systematization of taking measurements to characterize the modal interferometers. These are highly sensitive to several variables so the measurement process is very complicated. Variables must be fixed in a very controlled manner. Although all devices have the common characteristic of being selectively filled PCFs with some kind of material, each one has his own peculiarities, which are explained below.