997 resultados para Laser-Assisted CVD
Resumo:
To explore the discriminatory power of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for detecting subtle differences in isogenic isolates, we tested isogenic strains of Staphylococcus aureus differing in their expression of resistance to methicillin or teicoplanin. More important changes in MALDI-TOF MS spectra were found with strains differing in methicillin than in teicoplanin resistance. In comparison, very minor or no changes were recorded in pulsed-field gel electrophoresis profiles or peptidoglycan muropeptide digest patterns of these strains, respectively. MALDI-TOF MS might be useful to detect subtle strain-specific differences in ionizable components released from bacterial surfaces and not from their peptidoglycan network.
Resumo:
Pearson correlation coefficients were applied for the objective comparison of 30 black gel pen inks analysed by laser desorption ionization mass spectrometry (LDI-MS). The mass spectra were obtained for ink lines directly on paper using positive and negative ion modes at several laser intensities. This methodology has the advantage of taking into account the reproducibility of the results as well as the variability between spectra of different pens. A differentiation threshold could thus be selected in order to avoid the risk of false differentiation. Combining results from positive and negative mode yielded a discriminating power up to 85%, which was better than the one obtained previously with other optical comparison methodologies. The technique also allowed discriminating between pens from the same brand.
Resumo:
BACKGROUND: Vacuum-assisted closure (VAC) has become the preferred modality to treat many complex wounds but could be further improved by methods that minimize bleeding and facilitate wound epithelialization. Short fiber poly-N-acetyl glucosamine nanofibers (sNAG) are effective hemostatic agents that activate platelets and facilitate wound epithelialization. We hypothesized that sNAG used in combination with the VAC device could be synergistic in promoting wound healing while minimizing the risk of bleeding. METHODS: Membranes consisting entirely of sNAG nanofibers were applied immediately to dorsal excisional wounds of db/db mice followed by application of the VAC device. Wound healing kinetics, angiogenesis, and wound-related growth factor expression were measured. RESULTS: The application of sNAG membranes to wounds 24 hours before application of the VAC device was associated with a significant activation of wounds (expression of PDGF, TGFβ, EGF), superior granulation tissue formation rich in Collagen I as well as superior wound epithelialization (8.6% ± 0.3% vs. 1.8% ± 1.1% of initial wound size) and wound contraction. CONCLUSIONS: The application of sNAG fiber-containing membranes before the application of the polyurethane foam interface of VAC devices leads to superior healing in db/db mice and represents a promising wound healing adjunct that can also reduce the risk of bleeding complications.
Resumo:
Introduction : Un chylothorax est une pathologie comprenant des manifestations respiratoires, nutritionnelles et immunologiques. La récidive du chylothorax ou l'échec du traitement conservateur imposent un traitement chirurgical. Ce travail rapporte notre expérience de ligature supra-diaphragmatique, vidéo-assistée du canal thoracique, pour chylothorax récurrent non traumatique. Patients et méthodes : Entre 1999 et 2004, nous avons recensé six observations (quatre du côté droit, un du côté gauche et un bilateral) Le chylothorax s'est développé chez trois patients traités par radio et chimiothérapie pour tumeur (deux lymphomes et une tumeur du sein) un dans le contexte d'une lymphangioléiomatose et un après greffe cardiaque. Résultats : Les patients ont bénéficié sous anesthésie générale, d'une ligature du canal thoracique supra-diaphragmatique, vidéo-assistée. Le temps opératoire moyen a été de 102 minutes. Le chylothorax a régressé chez cinq des six patients en sept jours. Un patient a été repris par thoracotomie droite au huitième jour pour chylothorax persistant. Dans la phase post-opératoire, un patient a développé une détresse respiratoire nécessitant une ventilation mécanique. Un autre patient a présenté un chylopéritoine important traité par un stent de Le Veen®. Le séjour moyen a été de quatorze jours sans mortalité péri-opératoire. Conclusion : Le traitement du chylothorax non traumatique récurrent est, en première intention, un traitement médical. En cas de récidive ou d'échec du traitement conservateur, le traitement chirurgical par ligature du canal thoracique supra- diaphragmatique, vidéo-assistée, permet de traiter avec succès le chylothorax récurrent non traumatique. -- Background: Chylothorax is an uncommon disorder with respiratory, nutritional and immunological manifestations. Surgical management is indicated in case of recurrence or failure after conservative treatment. We report our experience with video-assisted right-sided supradiaphrag¬matic thoracic duct ligation for non-traumatic, non-postoperative persistent or recurrent chylothorax. Patients and methods: The medical records of six patients operated at our institution between 1999 and 2004 were retrospectively reviewed. A right-sided chylothorax was found in four patients, a left-sided in one, and a bilateral in one. Three patients developed chylothorax after chemotherapy and chest irradiation for malignant diseases (lymphoma in two patients and breast cancer in one), one in the context of lymphangioleiomyomatosis, one due to a non-diagnosed lymphoma, and one after heart transplantation. Results: The mean operative time was 102 min, with an average length of hospital stay of 14 days. Persistent cessation of chylous effusion within 7 days after surgery was observed in 5/6 patients without recurrence during a mean follow-up time of 41 months. One patient with undiagnosed mediastinal lymphoma required re-operation and thoracic duct ligation on day 8 by right-sided thoracotomy due to persistent chylothorax. No 30-day mortality was recorded. Two patients presented postoperative complications including respiratory insufficiency requiring mechanical ventilation in one, and chylous ascites development requiring peritoneo-venous LeVeen shunting in one patient. Conclusions: Recurrent or persistent non-traumatic chylothorax may be successfully treated by video-assisted right supradiaphragmatic thoracic duct ligation.
Resumo:
Electrotransfer and iontophoresis are being developed as innovative non-viral gene delivery systems for the treatment of eye diseases. These two techniques rely on the use of electric current to allow for higher transfection yield of various ocular cell types in vivo. Short pulses of relatively high-intensity electric fields are used for electrotransfer delivery, whereas the iontophoresis technique is based on the application of low voltage electric current. The basic principles of these techniques and their potential therapeutic application for diseases of the anterior and posterior segments of the eye are reviewed. Iontophoresis has been found most efficient for the delivery of small nucleic acid fragments such as antisense oligonucleotides, siRNA, or ribozymes. Electrotransfer, on the other hand, is being developed for the delivery of oligonucleotides or custom designed plasmids. The wide range of strategies already validated and the potential for targeting specific types of cells confirm the promising early observations made using electrotransfer and iontophoresis. These two nonviral delivery systems are safe and can be used efficiently for targeted gene delivery to ocular tissues in vivo. At the present, their application for the treatment of ocular human diseases is nearing its final stages of adaptation and practical implementation at the bedside.
Resumo:
Background: To evaluate outcomes after optimized laser in situ keratomileusis (LASIK) for astigmatism correction with flap created by a mechanical microkeratome or a femtosecond laser. Patients and Methods: In this retrospective study, a total of 102 eyes of 71 consecutive patients were enrolled undergoing optimized LASIK treatments using the Allegretto laser system (WaveLight Laser Technologie AG, Erlangen, Germany). A mechanical microkeratome for flap creation was used (One Use, Moria®) in 46 eyes (31 patients, spherical equivalent [SE] -4.44 D ± 2.4) and a femtosecond laser was used (LDV, Ziemer®) in 56 eyes (40 patients, spherical equivalent [SE] -3.07 D ± 3.3). The two groups were matched for inclusion criteria and were operated under similar conditions by the same surgeon. Results: Overall, the preoperative spherical equivalent was -9.5 diopters (D) to +3.37 D; the preoperative manifest astigmatism was between -1.5 D and -3.5 D. At 6 months postoperatively, the mean postoperative uncorrected distance visual acuity (UDVA) was 0.93 ± 0.17 (range 0.4 to 1.2) in the Moria group and 1.0 ± 0.21 (range 0.6 to 1.6) in the Femto group, which was statistically significant (p = 0.003). Comparing the cylinder power there was a statistical difference between the two groups (p = 0.0015). Conclusions: This study shows that the method of flap creation has a significant impact on postoperative astigmatism with a significantly better postoperative UDVA in the Femto group. These findings suggest that the femtosecond laser provides a better platform for LASIK treatment of astigmatism than the commonly used microkeratome.
Resumo:
In January 2006 the Centre Hospitalier Universitaire Vaudois (CHUV), a large university hospital in Lausanne, Switzerland, became the first hospital in Switzerland to allow assisted suicide (AS) in exceptional cases within its walls. However, euthanasia is illegal. This decision has posed several ethical and practical dilemmas for the hospital's palliative care consult service. To address these, the team embarked on a formal process of open dialogue amongst its members with the goal of identifying a collective response and position. This process involved meetings every 4 to 6 weeks over the course of 10 months. An iterative process unfolded. One of the principal dilemmas relates to finding a balance between the team's position against AS and the patient's autonomy and the institution's directive. Although all team members expressed opposition to AS, there were mixed opinions as to whether or not the team members should be present during the act if requested so by patients. Some thought this could be misinterpreted as complicity in the act and could send out mixed messages to the public and other health professionals about palliative care. Others felt that the team's commitment to nonabandonment obliged them to be present even if they did not provide the drug or give any advice or assistance. The implications of nonabandonment are explored, as are several other questions such as whether or not the teams are obliged to provide detailed information on AS when requested by patients.
Resumo:
Crushed seeds of the Moringa oleifera tree have been used traditionally as natural flocculants to clarify drinking water. We previously showed that one of the seed peptides mediates both the sedimentation of suspended particles such as bacterial cells and a direct bactericidal activity, raising the possibility that the two activities might be related. In this study, the conformational modeling of the peptide was coupled to a functional analysis of synthetic derivatives. This indicated that partly overlapping structural determinants mediate the sedimentation and antibacterial activities. Sedimentation requires a positively charged, glutamine-rich portion of the peptide that aggregates bacterial cells. The bactericidal activity was localized to a sequence prone to form a helix-loop-helix structural motif. Amino acid substitution showed that the bactericidal activity requires hydrophobic proline residues within the protruding loop. Vital dye staining indicated that treatment with peptides containing this motif results in bacterial membrane damage. Assembly of multiple copies of this structural motif into a branched peptide enhanced antibacterial activity, since low concentrations effectively kill bacteria such as Pseudomonas aeruginosa and Streptococcus pyogenes without displaying a toxic effect on human red blood cells. This study thus identifies a synthetic peptide with potent antibacterial activity against specific human pathogens. It also suggests partly distinct molecular mechanisms for each activity. Sedimentation may result from coupled flocculation and coagulation effects, while the bactericidal activity would require bacterial membrane destabilization by a hydrophobic loop.
Resumo:
Object Recent years have been marked by efforts to improve the quality and safety of pedicle screw placement in spinal instrumentation. The aim of the present study is to compare the accuracy of the SpineAssist robot system with conventional fluoroscopy-guided pedicle screw placement. Methods Ninety-five patients suffering from degenerative disease and requiring elective lumbar instrumentation were included in the study. The robot cohort (Group I; 55 patients, 244 screws) consisted of an initial open robot-assisted subgroup (Subgroup IA; 17 patients, 83 screws) and a percutaneous cohort (Subgroup IB, 38 patients, 161 screws). In these groups, pedicle screws were placed under robotic guidance and lateral fluoroscopic control. In the fluoroscopy-guided cohort (Group II; 40 patients, 163 screws) screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. The primary outcome measure was accuracy of screw placement on the Gertzbein-Robbins scale (Grade A to E and R [revised]). Secondary parameters were duration of surgery, blood loss, cumulative morphine, and length of stay. Results In the robot group (Group I), a perfect trajectory (A) was observed in 204 screws (83.6%). The remaining screws were graded B (n = 19 [7.8%]), C (n = 9 [3.7%]), D (n = 4 [1.6%]), E (n = 2 [0.8%]), and R (n = 6 [2.5%]). In the fluoroscopy-guided group (Group II), a completely intrapedicular course graded A was found in 79.8% (n = 130). The remaining screws were graded B (n = 12 [7.4%]), C (n = 10 [6.1%]), D (n = 6 [3.7%]), and E (n = 5 [3.1%]). The comparison of "clinically acceptable" (that is, A and B screws) was neither different between groups (I vs II [p = 0.19]) nor subgroups (Subgroup IA vs IB [p = 0.81]; Subgroup IA vs Group II [p = 0.53]; Subgroup IB vs Group II [p = 0.20]). Blood loss was lower in the robot-assisted group than in the fluoroscopy-guided group, while duration of surgery, length of stay, and cumulative morphine dose were not statistically different. Conclusions Robot-guided pedicle screw placement is a safe and useful tool for assisting spine surgeons in degenerative spine cases. Nonetheless, technical difficulties remain and fluoroscopy backup is advocated.
Resumo:
New child wish after vasectomy: vasovasostomy or assisted reproductive medicine? In the case of a new child wish after vasectomy, there are two options: vaso-vasostomy (VV) or biopsy of the testicle associated with intra-cytoplasmatic sperm injection (ICSI). Both methods are not reimbursed. The VV offers a cumulative pregnancy rate of 28-40%, depending on pre-, intra- and postoperative factors. The age of the female partner and the time after vasectomy are the most important factors. Pregnancy rates after ICSI are 29-41% per transfer. Cumulative pregnancy rates vary between 60-80%. Malformation rates after ICSI in this special collective are not investigated yet, the "general" ICSI-collective differs completely compared to the a priori fertile couples after vasectomy. Couples have to inform themselves about the experience of the doctors and their rate of success in order to minimize the risk of failure.
Resumo:
A statistical methodology for the objective comparison of LDI-MS mass spectra of blue gel pen inks was evaluated. Thirty-three blue gel pen inks previously studied by RAMAN were analyzed directly on the paper using both positive and negative mode. The obtained mass spectra were first compared using relative areas of selected peaks using the Pearson correlation coefficient and the Euclidean distance. Intra-variability among results from one ink and inter-variability between results from different inks were compared in order to choose a differentiation threshold minimizing the rate of false negative (i.e. avoiding false differentiation of the inks). This yielded a discriminating power of up to 77% for analysis made in the negative mode. The whole mass spectra were then compared using the same methodology, allowing for a better DP in the negative mode of 92% using the Pearson correlation on standardized data. The positive mode results generally yielded a lower differential power (DP) than the negative mode due to a higher intra-variability compared to the inter-variability in the mass spectra of the ink samples.
Resumo:
Purpose: To investigate the differences between Fundus Camera (Topcon TRC-50X) and Confocal Scanning Laser Ophthalmoscope (Heidelberg retina angiogram (HRA)) on the fundus autofluorescence (FAF) imaging (resolution and FAF characteristics). Methods: 105 eyes of 56 patients with various retinal diseases underwent FAF imaging with HRA (488nm exciter/500nm barrier filter) before fluorescein angiography (FFA) and Topcon Fundus Camera (580nm exciter/695nm barrier filter) before and after FFA. The quality of the FAF images was compared for their resolution and analysed for the influence of fixation stability and cataracts. Hypo-and hyper-FAF behaviour was analysed for the healthy disc, healthy fovea, and a variety of pathological features. Results: HRA images were found to be of superior resolution in 18, while Topcon images were estimated superior in 29 eyes. No difference was found in 58 eyes. Both poor fixation (p=0.009) and more advanced cataract (p=0.013) were found associated with better image quality by Topcon. Images acquired by Topcon before and after FFA were identical (100%). The healthy disc was usually dark on HRA (72%), but showed mild autofluorescence on Topcon (85%). The healthy fovea showed in 100% Hypo-FAF on HRA, while Topcon showed in 53% Iso-FAF, in 43% mild Hypo-FAF, and in 4% Hypo-FAF as on HRA. No difference of FAF was found for geographic atrophy, pigment changes, and drusen, although Topcon images were often more detailed. Hyper-FAF due to serous exudation showed better on HRA. Cystic edema was visible only on HRA in a petaloid hyper-FAF pattern in 83%, while only two eyes (17%) showed similar behavior in both HRA- and Topcon images. Hard exudates caused Hypo-FAF only on HRA, hardly visible on Topcon. Blockage phenomenon by blood however was identical. Conclusions: The filter set of Topcon and the single image acquisition appear to be an advantage for patients with cataract and poor fixation respectively. Preceding FFA does not alter the Topcon FAF image. Regarding the FAF behavior, there are differences between the 2 systems which need to be taken into account when interpreting the images.
Resumo:
BACKGROUND: Cytomegalovirus (CMV) infection is associated with significant morbidity and mortality in transplant recipients. Resistance against ganciclovir is increasingly observed. According to current guidelines, direct drug resistance testing is not always performed due to high costs and work effort, even when resistance is suspected. OBJECTIVES: To develop a more sensitive, easy applicable and cost-effective assay as proof of concept for direct drug resistance testing in CMV surveillance of post-transplant patients. STUDY DESIGN: Five consecutive plasma samples from a heart transplant patient with a primary CMV infection were analyzed by quantitative real-time polymerase chain reaction (rtPCR) as a surrogate marker for therapy failure, and by direct drug resistance detection assays such as Sanger sequencing and the novel primer extension (PEX) reaction matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) based method. RESULTS: This report demonstrates that PEX reaction followed by MALDI-TOF analysis detects the A594V mutation, encoding ganciclovir resistance, ten days earlier compared to Sanger sequencing and more than 30 days prior to an increase in viral load. CONCLUSION: The greatly increased sensitivity and rapid turnaround-time combined with easy handling and moderate costs indicate that this procedure could make a major contribution to improve transplantation outcomes.