983 resultados para Ipê roxo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although power-line communication (PLC) is not a new technology, its use to support communication with timing requirements is still the focus of ongoing research. Recently, a new infrastructure was presented, intended for communication using power lines from a central location to geographically dispersed nodes using inexpensive devices. This new infrastructure uses a two-level hierarchical power-line system, together with an IP-based network. Within this infrastructure, in order to provide end-toend communication through the two levels of the powerline system, it is necessary to fully understand the behaviour of the underlying network layers. The masterslave behaviour of the PLC MAC, together with the inherent dynamic topology of power-line networks are important issues that must be fully characterised. Therefore, in this paper we present a simulation model which is being used to study and characterise the behaviour of power-line communication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent developments in the factory floor technologies together with the widespread use of TCP/IP and the Internet are increasing the eagerness to support a new wide class of devices and applications, such as industrial multimedia applications, in factory floor networks. This paper presents how this new field of applications can be put into practice, via a manufacturing cell field trial being implemented. This manufacturing automation field trial involves the use of traditional distributed computer control systems and 'factory-floor-oriented' multimedia (e.g. voice, video) application services.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we describe a real-time industrial communication network able to support both controlrelated and multimedia traffic. The industrial communication network is based on the PROFIBUS standard, with multimedia capabilities being provided by an adequate integration of TCP/IP protocols into the PROFIBUS stack. From the operational point of view the integration of TCP/IP into PROFIBUS is by itself a challenge, since the master-slave nature of the PROFIBUS MAC makes complex the implementation of the symmetry inherent to IP communications. From the timeliness point of view the challenge is two folded. On one hand the multimedia traffic should not interfere with the timing requirements of the "native" control-related PROFIBUS traffic (typically hard real-time). On the other hand multimedia traffic requires certain levels of quality-of-service to be attained. In this paper we provide a methodology that enables fulfilling the timing requirements for both types of traffic in these real-time industrial LAN. Moreover, we describe suitable algorithms for the scheduling support of concurrent multimedia streams.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Virtual and augmented reality (VR/AR) are increasingly being used in various business scenarios and are important driving forces in technology development. However the usage of these technologies in the home environment is restricted due to several factors including lack of low-cost (from the client point of view) highperformance solutions. In this paper we present a general client/server rendering architecture based on Real-Time concepts, including support for a wide range of client platforms and applications. The idea of focusing on the real-time behaviour of all components involved in distributed IP-based VR scenarios is new and has not been addressed before, except for simple sub-solutions. This is considered as “the most significant problem with the IP environment” [1]. Thus, the most important contribution of this research will be the holistic approach, in which networking, end-systems and rendering aspects are integrated into a cost-effective infrastructure for building distributed real-time VR applications on IP-based networks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we describe how to integrate Internet Protocols (IP) into a typical hierarchical master-slave fieldbus network, supporting a logical ring token passing mechanism between master stations. The integration of the TCP/IP protocols in the fieldbus protocol rises a number of issues that must be addressed properly. In this paper we particularly address the issues related to the conveyance of IP fragments in fieldbus frames (fragmentation/de-fragmentation) and on how to support the symmetry inherent to the TCP/IP protocols in fieldbus slaves, which lack communication initiative.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although power-line communication (PLC) is not a new technology, its use to support data communication with timing requirements is still the focus of ongoing research. A new infrastructure intended for communication using power lines from a central location to dispersed nodes using inexpensive devices was presented recently. This new infrastructure uses a two-level hierarchical power-line system, together with an IP-based network. Due to the master-slave behaviour of the PLC medium access, together with the inherent dynamic topology of power-line networks, a mechanism to provide end-to-end communication through the two levels of the power-line system must be provided. In this paper we introduce the architecture of the PLC protocol layer that is being implemented for this end.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A iluminação pública é responsável por 3% do consumo de energia elétrica, em Portugal, tendo havido um crescimento no consumo de energia elétrica neste setor, entre 2000 e 2011, de cerca de 55%, com uma taxa média de crescimento anual de cerca de 5,1%. No ano de 2011, os custos com a iluminação pública rondaram os 170 M€, sendo que grande parte foram assegurados pelos Municípios. Atendendo ao panorama financeiro delicado de grande parte das autarquias do País, e sabendo que a iluminação pública tem um peso considerável nas despesas anuais de energia, faz sentido que se concentre aqui um esforço para tornar mais eficientes estas instalações. A nível nacional, a Estratégia Nacional para a Energia 2020 (ENE 2020) define estratégias que visam o cumprimento das medidas impostas pela União Europeia no sentido de cumprir objetivos que respeitem a sustentabilidade A ENE 2020 define uma agenda para a competitividade, o crescimento e a independência energética e financeira do país através da aposta nas energias renováveis e da promoção integrada da eficiência energética, assegurando a segurança de abastecimento e a sustentabilidade económica e ambiental do modelo energético. Um dos eixos em que se divide a ENE 2020 visa diretamente a promoção da eficiência energética na Iluminação Pública (IP), com o objetivo de promover e apoiar projetos inovadores de iluminação pública com prioridade para os centros históricos. Existem no mercado diversas soluções e tecnologias que permitem melhorar a eficiência energética da IP, facilitando uma gestão mais eficiente. Estes sistemas podem também permitir economias diretas nos consumos de energia e/ou levar a um aumento da vida útil das lâmpadas, permitindo uma redução dos custos de manutenção das instalações de IP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para a obtenção do grau de Mestre em Engenharia Civil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de doutoramento em Ciências da Educação

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Se ha poucos anos nao imaginavamos as nossas vidas sem o conforto proporcionado pela iluminacao artificial, fruto do desenvolvimento e proliferacao da producao, transporte e distribuicao de energia electrica, seguramente que nos dias de hoje e indissociavel juntar a esse mesmo conforto e estilo de vida a utilizacao dos meios de telecomunicacoes actuais. Com efeito, a vulgarizacao do uso de telemoveis, a recepcao e transmissao de dados a velocidades cada vez maiores, o aparecimento de televisao de alta definicao (TVAD) em substituicao do actual formato PAL, a surgimento de ofertas de novos servicos como o Video on Demand a par da emergente televisao digital terrestre constituem, seguramente, uma nova revolucao nas infra-estruturas de telecomunicacoes domesticas e profissionais. O sector das telecomunicacoes tem sido aquele que se encontra em pleno crescimento, com os fabricantes e operadores a lancarem novos produtos e solucoes de forma continuada, bem como uma atenta e perspicaz reaccao por parte dos legisladores. Assiste-se verdadeiramente na industria das telecomunicacoes a um movimento relacionado com a convergencia para as redes IP (“Internet Protocol”, ou Protocolo de Internet).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório de Estágio para obtenção do grau de Mestre em Engenharia Civil Perfil de Edificações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório de Estágio para obtenção do grau de Mestre em Engenharia Civil Perfil de Edificações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Informática

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado em Engenharia Informática

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Realizou-se inquérito sorológico para malária em escolares de Marabá — Pará, por meio de testes de imunofluorescência (IP) para anticorpos IgG e IgM, tendo como antígenos P. falciparum e P. gallinaceum, e teste de hemaglutinação (HAg) com P. gallinaceum. O teste IF-IgG com P. falciparum foi positivo em 6,94% dos 389 indivíduos estudados e o de P. gallinaceum em 11,56%, havendo concordância entre ambos os testes em 88,68% das amostras. No total, observou-se 14,91% de casos reagentes em qualquer dos testes. O teste com P. gallinaceum se mostrou mais abrangente provavelmente devido a maior prevalência na região de infecções por P. vivax. Ao se dividir a população estudada em faixas etárias de 6 a 10 anos (grupo A) e de 11 a 16 anos (grupo B), observou-se diferença significativa de reatividade ao teste IF-IgG com P. falciparum (2,68% para A e 10,94% para B) mas não com P. gallinaceum (10,10% para A e 12,97% para B). Para os testes IF-IgM houve positividade de 2,83% na população, e para o teste de HAg de 1,80%, sem diferença significativa entre os grupos etários A e B.