976 resultados para Ionospheric electromagnetic
Resumo:
The electromagnetic radiation at a terahertz frequencies (from 0.1 THz to 10 THz) is situated in the frequency band comprised between the optical band and the radio band. The interest of the scientific community in this frequency band has grown up due to its large capabilities to develop innovative imaging systems. The terahertz waves are able to generate extremely short pulses that achieve good spatial resolution, good penetration capabilities and allow to identify microscopic structures using spectral analysis. The work carried out during the period of the grant has been based on the developement of system working at the aforementioned frequency band. The main system is based on a total power radiometer working at 0.1 THz to perform security imaging. Moreover, the development of this system has been useful to gain knowledge in the behavior of the component systems at this frequency band. Moreover, a vectorial network analyzer has been used to characterize materials and perform active raster imaging. A materials measurement system has been designed and used to measure material properties as permittivity, losses and water concentration. Finally, the design of a terahertz time-domain spectrometer (THz-TDS) system has been started. This system will allow to perform tomographic measurement with very high penetration resolutions while allowing the spectral characterization of the sample material. The application range of this kind of system is very wide: from the identification of cancerous tissues of a skin to the characterization of the thickness of a painted surface of a car.
Resumo:
Electromagnetic fields arising from magnetic resonance imaging (MRI) can cause various clinically relevant functional disturbances in patients with cardiac pacemakers. Consequently, an implanted pacemaker is generally considered a contraindication for an MRI scan. With approximately 60 million MRI scans performed worldwide per year, MRI may be indicated for an estimated majority of pacemaker patients during the lifetime of their pacemakers. The availability of MR conditional pacemakers with CE labelling is of particular advantage since they allow the safe use of pacemakers in MRI. In this article the current state of knowledge on pacemakers and MR imaging is discussed. We present the results of a survey conducted among Swiss radiologists to assess current practice in patients with pacemakers.
Resumo:
Background. DNA-damage assays, quantifying the initial number of DNA double-strand breaks induced by radiation, have been proposed as a predictive test for radiation-induced toxicity. Determination of radiation-induced apoptosis in peripheral blood lymphocytes by flow cytometry analysis has also been proposed as an approach for predicting normal tissue responses following radiotherapy. The aim of the present study was to explore the association between initial DNA damage, estimated by the number of double-strand breaks induced by a given radiation dose, and the radio-induced apoptosis rates observed. Methods. Peripheral blood lymphocytes were taken from 26 consecutive patients with locally advanced breast carcinoma. Radiosensitivity of lymphocytes was quantified as the initial number of DNA double-strand breaks induced per Gy and per DNA unit (200 Mbp). Radio-induced apoptosis at 1, 2 and 8 Gy was measured by flow cytometry using annexin V/propidium iodide. Results. Radiation-induced apoptosis increased in order to radiation dose and data fitted to a semi logarithmic mathematical model. A positive correlation was found among radio-induced apoptosis values at different radiation doses: 1, 2 and 8 Gy (p < 0.0001 in all cases). Mean DSB/Gy/DNA unit obtained was 1.70 ± 0.83 (range 0.63-4.08; median, 1.46). A statistically significant inverse correlation was found between initial damage to DNA and radio-induced apoptosis at 1 Gy (p = 0.034). A trend toward 2 Gy (p = 0.057) and 8 Gy (p = 0.067) was observed after 24 hours of incubation. Conclusions. An inverse association was observed for the first time between these variables, both considered as predictive factors to radiation toxicity.
Resumo:
The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although statistically significant responses could be detected in more than 50% of trials for every subject. Overall, we conclude that the proposed setup is well suited for simultaneous EEG-fMRI at 7T.
Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.
Resumo:
OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.
Resumo:
Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.
Resumo:
Vitamin D deficiency is associated with higher cardiovascular risk and metabolic syndrome (MeS) criteria. The main objective of this study was to analyse the association of 25-hydroxyvitamin D (25-OHD) serum levels with MeS (National Cholesterol Education Program-Adult Treatment Panel-III criteria) in 46 Spanish patients with psoriasis, but without arthritis and systemic treatment, and 46 control subjects, matched by sex and age. The patients with psoriasis showed significantly lower level of 25-OHD than controls (30.5 vs. 38.3 ng/ml; p = 0.0001). Patients with MeS had significantly lower serum levels of 25-OHD than those without MeS (24.1 ± 7.5 vs. 32.8 ± 8.9, p = 0.007), and a negative correlation was found between 25-OHD and waist circumference, diastolic blood pressure, fasting glucose, and triglyceridaemia. In the control group no significant correlation between 25-OHD and MeS was found. Al-though the sample was small, our results suggest a potential protective role for 25-OHD in the metabolic profile of patients with psoriasis without arthritis.
Resumo:
This paper addresses a fully automatic landmarks detection method for breast reconstruction aesthetic assessment. The set of landmarks detected are the supraesternal notch (SSN), armpits, nipples, and inframammary fold (IMF). These landmarks are commonly used in order to perform anthropometric measurements for aesthetic assessment. The methodological approach is based on both illumination and morphological analysis. The proposed method has been tested with 21 images. A good overall performance is observed, although several improvements must be achieved in order to refine the detection of nipples and SSNs.
Resumo:
The restoration of body composition (BC) parameters is considered to be one of the most important goals in the treatment of patients with anorexia nervosa (AN). However, little is known about differences between AN diagnostic subtypes [restricting (AN-R) and binge/purging (AN-BP)] and weekly changes in BC during refeeding treatment. Therefore, the main objectives of our study were twofold: 1) to assess the changes in BC throughout nutritional treatment in an AN sample and 2) to analyze predictors of BC changes during treatment, as well as predictors of treatment outcome. The whole sample comprised 261 participants [118 adult females with AN (70 AN-R vs. 48 AN-BP), and 143 healthy controls]. BC was measured weekly during 15 weeks of day-hospital treatment using bioelectrical impedance analysis (BIA). Assessment measures also included the Eating Disorders Inventory-2, as well as a number of other clinical indices. Overall, the results showed that AN-R and AN-BP patients statistically differed in all BC measures at admission. However, no significant time×group interaction was found for almost all BC parameters. Significant time×group interactions were only found for basal metabolic rate (p = .041) and body mass index (BMI) (p = .035). Multiple regression models showed that the best predictors of pre-post changes in BC parameters (namely fat-free mass, muscular mass, total body water and BMI) were the baseline values of BC parameters. Stepwise predictive logistic regressions showed that only BMI and age were significantly associated with outcome, but not with the percentage of body fat. In conclusion, these data suggest that although AN patients tended to restore all BC parameters during nutritional treatment, only AN-BP patients obtained the same fat mass values as healthy controls. Put succinctly, the best predictors of changes in BC were baseline BC values, which did not, however, seem to influence treatment outcome.
Resumo:
An alternative approach to the fundamental general physics concepts has been proposed. We demonstrate that the electrostatic potential energy of a discrete or a continuous system of charges should be stored by the charges and not the field. It is found that there is a possibility that any electric field has no energy density, as well as magnetic field. It is found that there is no direct relation between the electric or magnetic energy and photons. An alternative derivation of the blackbody radiation formula is proposed. It is also found that the zero-point of energy of electromagnetic radiation may not exist.
Technologies de procédé et de contrôle pour réduire la teneur en sel du jambon sec et des saucissons
Resumo:
Dans certains pays européens, les produits carnés élaborés peuvent représenter près de 20% de la consommation journalière de sodium. De ce fait, les industries de la viande tentent de réduire la teneur en sel dans les produits carnés pour répondre, d’une part aux attentes des consommateurs et d’autre part aux demandes des autorités sanitaires. Le système Quick‐Dry‐Slice process (QDS®), couplé avec l’utilisation de sels substituant le chlorure de sodium (NaCl), a permis de fabriquer, avec succès, des saucisses fermentées à basse teneur en sel en réduisant le cycle de fabrication et sans ajout de NaCl supplémentaire. Les technologies de mesure en ligne non destructives, comme les rayons X et l’induction électromagnétique, permettent de classifier les jambons frais suivant leur teneur en gras, un paramètre crucial pour adapter la durée de l’étape de salaison. La technologie des rayons X peut aussi être utilisée pour estimer la quantité de sel incorporée pendant la salaison. L’information relative aux teneurs en sel et en gras est importante pour optimiser le processus d’élaboration du jambon sec en réduisant la variabilité de la teneur en sel entre les lots et dans un même lot, mais aussi pour réduire la teneur en sel du produit final. D’autres technologies comme la spectroscopie en proche infrarouge (NIRS) ou spectroscopie microondes sont aussi utiles pour contrôler le processus d’élaboration et pour caractériser et classifier les produits carnés élaborés, selon leur teneur en sel. La plupart de ces technologies peuvent être facilement appliquées en ligne dans l’industrie afin de contrôler le processus de fabrication et d’obtenir ainsi des produits carnés présentant les caractéristiques recherchées.
Resumo:
High-resolution tomographic imaging of the shallow subsurface is becoming increasingly important for a wide range of environmental, hydrological and engineering applications. Because of their superior resolution power, their sensitivity to pertinent petrophysical parameters, and their far reaching complementarities, both seismic and georadar crosshole imaging are of particular importance. To date, corresponding approaches have largely relied on asymptotic, ray-based approaches, which only account for a very small part of the observed wavefields, inherently suffer from a limited resolution, and in complex environments may prove to be inadequate. These problems can potentially be alleviated through waveform inversion. We have developed an acoustic waveform inversion approach for crosshole seismic data whose kernel is based on a finite-difference time-domain (FDTD) solution of the 2-D acoustic wave equations. This algorithm is tested on and applied to synthetic data from seismic velocity models of increasing complexity and realism and the results are compared to those obtained using state-of-the-art ray-based traveltime tomography. Regardless of the heterogeneity of the underlying models, the waveform inversion approach has the potential of reliably resolving both the geometry and the acoustic properties of features of the size of less than half a dominant wavelength. Our results do, however, also indicate that, within their inherent resolution limits, ray-based approaches provide an effective and efficient means to obtain satisfactory tomographic reconstructions of the seismic velocity structure in the presence of mild to moderate heterogeneity and in absence of strong scattering. Conversely, the excess effort of waveform inversion provides the greatest benefits for the most heterogeneous, and arguably most realistic, environments where multiple scattering effects tend to be prevalent and ray-based methods lose most of their effectiveness.
Resumo:
Els monopols es defineixen, teòricament, com càrregues que generen camps amb divergència diferent de cero. Malgrat això, les entitats amb comportament mimètic al dels monopols magnètics, segueix sent compatible amb ∇·B=0, han estat detectades experimentalment en gels d’espín (‘spin-ices’). Aquesta aparent contradicció pot generar confusió i, per tant, requereix explicació. D’altra banda, s’estudien propietats duals del materials amb càrregues magnètiques efectives tals com la ‘magnetricity’ en els ‘spinices’ (conductivitat de les càrregues magnètiques davant un camp magnètic extern). Com una conseqüència de la magnetricitat, l’apantallament del camp magnètic en materials amb càrregues magnètiques és analitzat. Estudio la propagació d’ones electromagnètiques transversals en medis materials infinits i en plasmes magnètics diluïts davant la presència de camps elèctrics externs constants. Aquesta propagació és dual a la propagació d’ones en plasmes de càrregues elèctriques davant la presència de camps magnètics externs, constants. Finalment, estudio el frenat elèctric d’un conductor de càrregues magnètiques amb un efecte dual al frenat magnètic en conductors elèctrics.
Resumo:
In vivo localized proton magnetic resonance spectroscopy (1H MRS) became a powerful and unique technique to non-invasively investigate brain metabolism of rodents and humans. The main goal of 1H MRS is the reliable quantification of concentrations of metabolites (neurochemical profile) in a well-defined region of the brain. The availability of very high magnetic field strengths combined with the possibility of acquiring spectra at very short echo time have dramatically increased the number of constituents of the neurochemical profile. The quantification of spectra measured at short echo times is complicated by the presence of macromolecule signals of particular importance at high magnetic fields. An error in the macromolecule estimation can lead to substantial errors in the obtained neurochemical profile. The purpose of the present review is to overview methods of high field 1H MRS with a focus on the metabolite quantification, in particular in handling signals of macromolecules. Three main approaches of handling signals of macromolecules are described, namely mathematical estimation of macromolecules, measurement of macromolecules in vivo, and direct acquisition of the in vivo spectrum without the contribution of macromolecules.
Resumo:
Un dels reptes tecnològics més importants del segle XXI és el desenvolupament i organització de materials funcionals a escala nanomètrica ja que permet modificar-ne les propietats fonamentals i generar-ne de noves. En el cas dels òxids complexos aquesta tecnologia ha generat grans perspectives en diferents àrees d’estudi perquè presenten propietats molt interessants com la magnetoresistència colossal, superconductivitat o multiferroicitat. En particular, en l’òxid complex superconductor YBa2Cu3O7 (YBCO) s’ha demostrat que la formació de capes superconductores sobre plantilles nanoestructurades o bé la formació de nanocompostos en una matriu superconductora permet millorar de manera espectacular les seves propietats (corrent crític). Aquests resultats introduiran canvis paradigmàtics en la tecnologia de l’energia elèctrica (cables, motors, generadors) i en totes aquelles aplicacions que requereixin camps magnètics intensos. Ara bé, cal aconseguir-ho mitjançant tècniques de baix cost i que permetin un fàcil escalat. Durant els 4 mesos que s’ha disfrutat de l’ajut BP s’han preparat amb èxit noves capes primes superconductores nanoestructurades mitjançant la introducció d’una fase secundària nanomètrica complexa, Ba2YTaO6 (BYTO), dins la matriu d’YBCO pel mètode de baix cost de deposició de solucions químiques. Aquesta nova composició ha donat lloc a un augment significatiu de les propietats superconductores comparat amb la fase tradicional d’YBCO i per tant tenen gran potencial per fabricar futures cintes superconductores.