970 resultados para Illinois. Ambient Air Monitoring Section


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bacteria are generally difficult specimens to prepare for conventional resin section electron microscopy and mycobacteria, with their thick and complex cell envelope layers being especially prone to artefacts. Here we made a systematic comparison of different methods for preparing Mycobacterium smegmatis for thin section electron microscopy analysis. These methods were: (1) conventional preparation by fixatives and epoxy resins at ambient temperature. (2) Tokuyasu cryo-section of chemically fixed bacteria. (3) rapid freezing followed by freeze substitution and embedding in epoxy resin at room temperature or (4) combined with Lowicryl HM20 embedding and ultraviolet (UV) polymerization at low temperature and (5) CEMOVIS, or cryo electron microscopy of vitreous sections. The best preservation of bacteria was obtained with the cryo electron microscopy of vitreous sections method, as expected, especially with respect to the preservation of the cell envelope and lipid bodies. By comparison with cryo electron microscopy of vitreous sections both the conventional and Tokuyasu methods produced different, undesirable artefacts. The two different types of freeze-substitution protocols showed variable preservation of the cell envelope but gave acceptable preservation of the cytoplasm, but not lipid bodies, and bacterial DNA. In conclusion although cryo electron microscopy of vitreous sections must be considered the 'gold standard' among sectioning methods for electron microscopy, because it avoids solvents and stains, the use of optimally prepared freeze substitution also offers some advantages for ultrastructural analysis of bacteria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rationale: There is increasing evidence that short-term exposure to air pollution has a detrimental effect on respiratory health, but data from healthy populations, particularly infants, are scarce. Objectives: To assess the association of air pollution with frequency and severity of respiratory symptoms and infections measured weekly in healthy infants. Methods: In a prospective birth cohort of 366 infants of unselected mothers, respiratory health was assessed weekly by telephone interviews during the first year of life (19,106 total observations). Daily mean levels of particulate matter (PM10), nitrogen dioxide (NO2), and ozone (O3) were obtained from local monitoring stations. We determined the association of the preceding week's pollutant levels with symptom scores and respiratory tract infections using a generalized additive mixed model with an autoregressive component. In addition, we assessed whether neonatal lung function influences this association and whether duration of infectious episodes differed between weeks with normal PM10 and weeks with elevated levels. Measurements and Main Results: We found a significant association between air pollution and respiratory symptoms, particularly in the week after respiratory tract infections (risk ratio, 1.13 [1.02-1.24] per 10 μg/m(3) PM10 levels) and in infants with premorbid lung function. During times of elevated PM10 (>33.3 μg/m(3)), duration of respiratory tract infections increased by 20% (95% confidence interval, 2-42%). Conclusions: Exposure to even moderate levels of air pollution was associated with increased respiratory symptoms in healthy infants. Particularly in infants with premorbid lung function and inflammation, air pollution contributed to longer duration of infectious episodes with a potentially large socioeconomic impact.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traffic particle concentrations show considerable spatial variability within a metropolitan area. We consider latent variable semiparametric regression models for modeling the spatial and temporal variability of black carbon and elemental carbon concentrations in the greater Boston area. Measurements of these pollutants, which are markers of traffic particles, were obtained from several individual exposure studies conducted at specific household locations as well as 15 ambient monitoring sites in the city. The models allow for both flexible, nonlinear effects of covariates and for unexplained spatial and temporal variability in exposure. In addition, the different individual exposure studies recorded different surrogates of traffic particles, with some recording only outdoor concentrations of black or elemental carbon, some recording indoor concentrations of black carbon, and others recording both indoor and outdoor concentrations of black carbon. A joint model for outdoor and indoor exposure that specifies a spatially varying latent variable provides greater spatial coverage in the area of interest. We propose a penalised spline formation of the model that relates to generalised kringing of the latent traffic pollution variable and leads to a natural Bayesian Markov Chain Monte Carlo algorithm for model fitting. We propose methods that allow us to control the degress of freedom of the smoother in a Bayesian framework. Finally, we present results from an analysis that applies the model to data from summer and winter separately

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study is to provide a procedure to include emissions to the atmosphere resulting from the combustion of diesel fuel during dredging operations into the decision-making process of dredging equipment selection. The proposed procedure is demonstrated for typical dredging methods and data from the Illinois Waterway as performed by the U.S. Army Corps of Engineers, Rock Island District. The equipment included in this study is a 16-inch cutterhead pipeline dredge and a mechanical bucket dredge used during the 2005 dredging season on the Illinois Waterway. Considerable effort has been put forth to identify and reduce environmental impacts from dredging operations. Though environmental impacts of dredging have been studied no efforts have been applied to the evaluation of air emissions from comparable types of dredging equipment, as in this study. By identifying the type of dredging equipment with the lowest air emissions, when cost, site conditions, and equipment availability are comparable, adverse environmental impacts can be minimized without compromising the dredging project. A total of 48 scenarios were developed by varying the dredged material quantity, transport distance, and production rates. This produced an “envelope” of results applicable to a broad range of site conditions. Total diesel fuel consumed was calculated using standard cost estimating practices as defined in the U.S. Army Corps of Engineers Construction Equipment Ownership and Operating Expense Schedule (USACE, 2005). The diesel fuel usage was estimated for all equipment used to mobilize and/or operate each dredging crew for every scenario. A Limited Life Cycle Assessment (LCA) was used to estimate the air emissions from two comparable dredging operations utilizing SimaPro LCA software. An Environmental Impact Single Score (EISS) was the SimaPro output selected for comparison with the cost per CY of dredging, potential production rates, and transport distances to identify possible decision points. The total dredging time was estimated for each dredging crew and scenario. An average hourly cost for both dredging crews was calculated based on Rock Island District 2005 dredging season records (Graham 2007/08). The results from this study confirm commonly used rules of thumb in the dredging industry by indicating that mechanical bucket dredges are better suited for long transport distances and have lower air emissions and cost per CY for smaller quantities of dredged material. In addition, the results show that a cutterhead pipeline dredge would be preferable for moderate and large volumes of dredged material when no additional booster pumps are required. Finally, the results indicate that production rates can be a significant factor when evaluating the air emissions from comparable dredging equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gas sensors have been used widely in different important area including industrial control, environmental monitoring, counter-terrorism and chemical production. Micro-fabrication offers a promising way to achieve sensitive and inexpensive gas sensors. Over the years, various MEMS gas sensors have been investigated and fabricated. One significant type of MEMS gas sensors is based on mass change detection and the integration with specific polymer. This dissertation aims to make contributions to the design and fabrication of MEMS resonant mass sensors with capacitance actuation and sensing that lead to improved sensitivity. To accomplish this goal, the research has several objectives: (1) Define an effective measure for evaluating the sensitivity of resonant mass devices; (2) Model the effects of air damping on microcantilevers and validate models using laser measurement system (3) Develop design guidelines for improving sensitivity in the presence of air damping; (4) Characterize the degree of uncertainty in performance arising from fabrication variation for one or more process sequences, and establish design guidelines for improved robustness. Work has been completed toward these objectives. An evaluation measure has been developed and compared to an RMS based measure. Analytic models of air damping for parallel plate that include holes are compared with a COMSOL model. The models have been used to identify cantilever design parameters that maximize sensitivity. Additional designs have been modeled with COMSOL and the development of an analytical model for Fixed-free cantilever geometries with holes has been developed. Two process flows have been implemented and compared. A number of cantilever designs have been fabricated and the uncertainty in process has been investigated. Variability from processing have been evaluated and characterized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The South Florida Water Management District (SFWMD) manages and operates numerous water control structures that are subject to scour. In an effort to reduce scour downstream of these gated structures, laboratory experiments were performed to investigate the effect of active air-injection downstream of the terminal structure of a gated spillway on the depth of the scour hole. A literature review involving similar research revealed significant variables such as the ratio of headwater-to-tailwater depths, the diffuser angle, sediment uniformity, and the ratio of air-to-water volumetric discharge values. The experimental design was based on the analysis of several of these non-dimensional parameters. Bed scouring at stilling basins downstream of gated spillways has been identified as posing a serious risk to the spillway’s structural stability. Although this type of scour has been studied in the past, it continues to represent a real threat to water control structures and requires additional attention. A hydraulic scour channel comprised of a head tank, flow straightening section, gated spillway, stilling basin, scour section, sediment trap, and tail-tank was used to further this analysis. Experiments were performed in a laboratory channel consisting of a 1:30 scale model of the SFWMD S65E spillway structure. To ascertain the feasibility of air injection for scour reduction a proof-of-concept study was performed. Experiments were conducted without air entrainment and with high, medium, and low air entrainment rates for high and low headwater conditions. For the cases with no air entrainment it was found that there was excessive scour downstream of the structure due to a downward roller formed upon exiting the downstream sill of the stilling basin. When air was introduced vertically just downstream of, and at the same level as, the stilling basin sill, it was found that air entrainment does reduce scour depth by up to 58% depending on the air flow rate, but shifts the deepest scour location to the sides of the channel bed instead of the center. Various hydraulic flow conditions were tested without air injection to verify which scenario caused more scour. That scenario, uncontrolled free, in which water does not contact the gate and the water elevation in the stilling basin is lower than the spillway crest, would be used for the remainder of experiments testing air injection. Various air flow rates, diffuser elevations, air hole diameters, air hole spacings, diffuser angles and widths were tested in over 120 experiments. Optimal parameters include air injection at a rate that results in a water-to-air ratio of 0.28, air holes 1.016mm in diameter the entire width of the stilling basin, and a vertically orientated injection pattern. Detailed flow measurements were collected for one case using air injection and one without. An identical flow scenario was used for each experiment, namely that of a high flow rate and upstream headwater depth and a low tailwater depth. Equilibrium bed scour and velocity measurements were taken using an Acoustic Doppler Velocimeter at nearly 3000 points. Velocity data was used to construct a vector plot in order to identify which flow components contribute to the scour hole. Additionally, turbulence parameters were calculated in an effort to help understand why air-injection reduced bed scour. Turbulence intensities, normalized mean flow, normalized kinetic energy, and anisotropy of turbulence plots were constructed. A clear trend emerged that showed air-injection reduces turbulence near the bed and therefore reduces scour potential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation represents experimental and numerical investigations of combustion initiation trigged by electrical-discharge-induced plasma within lean and dilute methane air mixture. This research topic is of interest due to its potential to further promote the understanding and prediction of spark ignition quality in high efficiency gasoline engines, which operate with lean and dilute fuel-air mixture. It is specified in this dissertation that the plasma to flame transition is the key process during the spark ignition event, yet it is also the most complicated and least understood procedure. Therefore the investigation is focused on the overlapped periods when plasma and flame both exists in the system. Experimental study is divided into two parts. Experiments in Part I focuses on the flame kernel resulting from the electrical discharge. A number of external factors are found to affect the growth of the flame kernel, resulting in complex correlations between discharge and flame kernel. Heat loss from the flame kernel to code ambient is found to be a dominant factor that quenches the flame kernel. Another experimental focus is on the plasma channel. Electrical discharges into gases induce intense and highly transient plasma. Detailed observation of the size and contents of the discharge-induced plasma channel is performed. Given the complex correlation and the multi-discipline physical/chemical processes involved in the plasma-flame transition, the modeling principle is taken to reproduce detailed transitions numerically with minimum analytical assumptions. Detailed measurement obtained from experimental work facilitates the more accurate description of initial reaction conditions. The novel and unique spark source considering both energy and species deposition is defined in a justified manner, which is the key feature of this Ignition by Plasma (IBP) model. The results of numerical simulation are intuitive and the potential of numerical simulation to better resolve the complex spark ignition mechanism is presented. Meanwhile, imperfections of the IBP model and numerical simulation have been specified and will address future attentions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Severe respiratory distress syndrome (RDS) caused by surfactant deficiency is described not only in preterm infants but also in (near-) term babies after caesarean section (CS), especially when carried out before the onset of labour. The aim of the present study was to document the severity of this theoretically avoidable entity in order to improve obstetric and perinatal care. PATIENTS: All neonates admitted to the paediatric intensive care unit of the University Hospital of Bern between 1988 and 2000 with RDS on the basis of hyaline membrane disease (HMD) needing mechanical ventilation (MV) after CS and with a birthweight > or = 2500 g were analysed. HMD was diagnosed when respiratory distress and the typical radiological signs were present. Patients were grouped into elective CS before onset of labour and before rupture of membranes (group 1, n = 34) and patients delivered by emergency CS or CS after onset of labour or rupture of membranes (group 2, n = 22). Analysed indices for severity of illness were duration of stay in intensive care unit and MV, ventilation mode, worst oxygenation index (OI), presence of pulmonary air leak, and systemic hypotension. RESULTS: Mean gestational age (GA) was 37 2/7 weeks in group 1 and 36 2/7 weeks in group 2; no patient had a GA of > or = 39 0/7 weeks. Duration of MV was 4.4 days in group 1 and 3.9 days in group 2. Thirteen patients (38%) of group 1 and 7 (32%) of group 2 had to be managed by rescue high-frequency ventilation. A total of 7 patients had an OI>40. Eight patients (24%) in group 1 and 4 (18%) in group 2 developed a pulmonary air leak. Fourteen neonates (41%) in group 1 had to be supported by catecholamines versus 5 (22%) in group 2. There was one death in group 1. CONCLUSION: Severe RDS on the basis of HMD can also occur in near-term babies after CS; even a fatal outcome can not be excluded. The severity of illness in elective CS without labour may be quite high and is comparable to newborns delivered by CS (after onset of labour and/or rupture of the membranes) who were 1 week younger. No case of HMD was found in our population when CS was carried out after completion of 39 post-menstrual weeks of gestation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION This report from the World Psychiatric Association Section on Pharmacopsychiatry examines the possible relationship of antiepileptic drugs with suicide-related clinical features and behaviors in patients with epilepsy. MATERIALS AND METHODS A systematic review of the MEDLINE search returned 1039 papers, of which only 8 were considered relevant. A critical analysis of the Food and Drug Administration (FDA) report on the increase risk for patients under antiepileptics to manifest suicidality is also included in this report. RESULTS The analysis of these studies revealed that the data are not supportive of the presence of a "class effect" on suicide-related behavior; on the contrary, there are some data suggesting such an effect concerning treatment with topiramate, lamotrigine, and levetiracetam for which further research is needed. DISCUSSION For the majority of people with epilepsy, anticonvulsant treatment is necessary and its failure for any reason is expected to have deleterious consequences. Therefore, clinicians should inform patients and their families of this increased risk of suicidal ideation and behavior, but should not overemphasize the issue. Specific subgroups of patients with epilepsy might be at a higher risk, and deserve closer monitoring and follow-up. Future research with antiepileptics should specifically focus on depression and suicidal thoughts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate assessments of fish populations are often limited by re-observation or recapture events. Since the early 1990s, passive integrated transponders (PIT tags) have been used to understand the biology of many fish species. Until recently, PIT applications in small streams have been limited to physical recapture events. To maximize recapture probability, we constructed PIT antenna arrays in small streams to remotely detect individual fish. Experiences from two different laboratories (three case studies) allowed us to develop a unified approach to applying PIT technology for enhancing data assessments. Information on equipment, its installation, tag considerations, and array construction is provided. Theoretical and practical definitions are introduced to standardize metrics for assessing detection efficiency. We demonstrate how certain conditions (stream discharge, vibration, and ambient radio frequency noise) affect the detection efficiency and suggest that by monitoring these conditions, expectations of efficiency can be modified. We emphasize the importance of consistently estimating detection efficiency for fisheries applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The airliner cabin environment and its effects on occupant health have not been fully characterized. This dissertation is: (1) A review of airliner environmental control systems (ECSs) that modulate the ventilation, temperature, relative humidity (RH), and barometric pressure (PB) of the cabin environment---variables related to occupant comfort and health. (2) A review and assessment of the methods and findings of key cabin air quality (CAQ) investigations. Several significant deficiencies impede the drawing of inferences about CAQ, e.g., lack of detail about investigative methods, differences in methods between investigations, limited assessment of CAQ variables, small sample sizes, and technological deficiencies of data collection. (3) A comprehensive evaluation of the methods used in the subsequent NIOSH-FAA Airliner CAQ Exposure Assessment Feasibility Study (STUDY) in which this author participated. A number of problems were identified which limit the usefulness of the data. (4) An analysis of the reliable 10-flight STUDY data. Univariate and multivariate methods applied to CO2 (a surrogate for air contaminants), temperature, RH, and PB, in association with percent passenger load, ventilation system, flight duration, airliner body type, and measurement location within the cabin, revealed neither the measured values nor their variability exceeded established health-based exposure limits. Regression analyses suggest CO2, temperature, and RH were affected by percent passenger load. In-flight measurements of CO2 and RH were relatively independent of ventilation system type or flight duration. Cabin temperature was associated with percent passenger load, ventilation system type, and flight duration. (5) A synthesis of the implications of the airliner ECS and cabin O2 environment on occupant health. A model was developed to predict consequences of the airliner cabin pressure altitude 8,000 ft limit and resulting model-estimated PO2 on cardiopulmonary status. Based on the PB, altitude, and environmental data derived from the 10 STUDY flights, the predicted PaO2 of adults with COPD, or elderly adults with or without COPD, breathing ambient cabin air could be < 55 mm Hg (SaO2 < 88%). Reduction in cabin PB found in the STUDY flights could aggravate various medical conditions and require the use of in-flight supplemental O2. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Species variations in formaldehyde solutions and gases were investigated by means of infrared spectral analysis. Double beam infrared spectrometry in conjunction with sodium chloride wafer technique and solvent compensation technique were employed. Formaldehyde species in various solutions were investigated. Formalin 37% was stable for many months. Refrigeration had no effects on its stability. Spectral changes were detected in 1000 ppm formaldehyde solutions. The absorbances of very diluted solutions up to 100 ppm were lower than the detection limit of the instruments. Solvent compensation improved resolution, but was associated with an observed lack of repeatability. Formaldehyde species in animal chambers containing animals and in mobile home air were analyzed with the infrared spectrophotometer equipped with a 10 cm gas cell. Spectra were not different from the spectrum of clean air. A portable single beam infrared spectrometer with a 20 meter pathlength was used for reinvestigation. Indoor formaldehyde could not be detected in the spectral; conversely, an absorption peak at 3.58 microns was found in the spectra of 3 and 15 ppm formaldehyde gas in animal chambers. This peak did not appear in the spectrum of the control chamber. Because of concerns over measurement bias among various analytical methods for formaldehyde, side-by-side comparisons were conducted in both laboratory and field measurements. The chromotropic acid method with water and 1% sodium bisulfite as collection media, the pararosaniline method, and a single beam infrared spectrometer were compared. Measurement bias was elucidated and the extent of the effects of temperature and humidity was also determined. The problems associated with related methods were discussed. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the indoor environment of two different types of dental practices regarding VOCs, PM2.5, and ultrafine particulate concentrations and examine the relationship between specific dental activities and contaminant levels. Method: The indoor environments of two selected dental settings (private practice and community health center) will were assessed in regards to VOCs, PM 2.5, and ultrafine particulate concentrations, as well as other indoor air quality parameters (CO2, CO, temperature, and relative humidity). The sampling duration was four working days for each dental practice. Continuous monitoring and integrated sampling methods were used and number of occupants, frequency, type, and duration of dental procedures or activities recorded. Measurements were compared to indoor air quality standards and guidelines. Results: The private practice had higher CO2, CO, and most VOC concentrations than the community health center, but the community health center had higher PM2.5 and ultrafine PM concentrations. Concentrations of p-dichlorobenzene and PM2.5 exceeded some guidelines. Outdoor concentrations greatly influenced the indoor concentration. There were no significant differences in contaminant levels between the operatory and general area. Indoor concentrations during the working period were not always consistently higher than during the nonworking period. Peaks in particulate matter concentration occurred during root canal and composite procedures.^