992 resultados para Higher yield
Resumo:
This paper studies price determination in pharmaceutical markets using data for 25 countries, six years and a comprehensive list of products from the MIDAS IMS database. We show that market power and the quality of the product has a significantly positive impact of prices. The nationality of the producer appears to have a small and often insignificant impact on prices, which suggests that countries which regulates prices have relatively little power to do it in a way that advances narrow national interest. We produce a theoretical explanation for this phenomenon based on the fact that low negotiated prices in a country would have a knock-on effect in other markets, and is thus strongly resisted by producers. Another key finding is that the U.S. has prices that are not significantly higher than those of countries with similar income levels. This, together with the former observation on the effect of the nationality of producers casts doubt on the ability of countries to purs
Resumo:
Increasing greenhouse light transmission has a positive effect not only in Northern latitudes but in Mediterranean countries as well. A greenhouse, H2, with a tetrafluoroethylene copolymer 60 microns film, (Asahi Glass company, Aflex) characterised by its high light transmission and durability was compared to another greenhouse with a co-extruded film considered as a control, H1. Tomato crop response to the increase in light during winter and summer with high temperature and light was evaluated. Light transmission in H2 remained very high in spite of the observed dust accumulation and the low angle of incidence of the winter solar radiation. Transmissivity was clearly higher for H2 (81 to 83 % throughout the season) than in the control (around 63 %). The rest of the climatic parameters were similar in both greenhouses, either in the winter or in the summer evaluations. In spite of the high solar radiation in H2, the summer temperature could be maintained at the desired levels by using evaporative cooling. Accumulated tomato yield and quality was better in the H2 greenhouse (15 % more for the winter crop and 27% more for the summer crop). Fruit size was bigger in the winter crop. As an overall conclusion, the use of high light transmissive films in Mediterranean areas is very convenient for many vegetable crops. This is valid not only in winter but in summer, provided the greenhouse has good ventilation or evaporative cooling to overcome the increase in sensible heat caused by this increase in light..
Resumo:
White micas in carbonate-rich tectonites and a few other rock types of large thrusts in the Swiss Helvetic fold-and-thrust belt have been analyzed by Ar-40/Ar-39 and Rb/Sr techniques to better constrain the timing of Alpine deformation for this region. Incremental Ar-40/Ar-39 heating experiments of 25 weakly metamorphosed (anchizone to low greenschist) samples yield plateau and staircase spectra. We interpret most of the staircase release spectra result from variable mixtures of syntectonic (neoformed) and detrital micas. The range in dates obtained within individual spectra depends primarily on the duration of mica nucleation and growth, and relative proportions of neoformed and detrital mica. Rb/Sr analyses of 12 samples yield dates of ca. 10-39 Ma (excluding one anomalously young sample). These dates are slightly younger than the Ar-40/Ar-39 total gas dates obtained for the same samples. The Rb/ Sr dates were calculated using initial Sr-87/Sr-86 ratios obtained from the carbonate-dominated host rocks, which are higher than normal Mesozoic carbonate values due to exchange with fluids of higher Sr-87/Sr-86 ratios (and lower O-18/O-16 ratios). Model dates calculated using Sr-87/Sr-86 values typical of Mesozoic marine carbonates more closely approximate the Ar-40/Ar-39 total gas dates for most of the samples. The similarities of Rb/Sr and Ar-40/Ar-39 total gas dates are consistent with limited amounts of detrital mica in the samples. The delta(18)O values range from 24-15%. (VSMOW) for 2-6 mum micas and 27-16parts per thousand for the carbonate host rocks. The carbonate values are significantly lower than their protolith values due to localized fluid-rock interaction and fluid flow along most thrust surfaces. Although most calcite-mica pairs are not in oxygen isotope equilibrium at temperatures of ca. 200-400 degreesC, their isotopic fractionations are indicative of either 1) partial exchange between the minerals and a common external fluid, or 2) growth or isotopic exchange of the mica with the carbonate after the carbonate had isotopically exchanged with an external fluid. The geological significance of these results is not easily or uniquely determined, and exemplifies the difficulties inherent in dating very fine-grained micas of highly deformed tectonites in low-grade metamorphic terranes. Two generalizations can be made regarding the dates obtained from the Helvetic thrusts: 1) samples from the two highest thrusts (Mt. Gond and Sublage) have all of their Ar-40/Ar-39 steps above 20 Ma, and 2) most samples from the deepest Helvetic thrusts have steps (often accounting for more than 80% of Ar-39 release) between 15 and 25 Ma. These dates are consistent with the order of thrusting in the foreland-imbricating system and increase proportions of neoformed to detrital mica in the more metamorphosed hinterland and deeply buried portions of the nappe pile. Individual thrusts accommodated the majority of their displacement during their initial incorporation into the foreland-imbricating system, and some thrusts remained active or were reactivated down to 15 Ma.
Resumo:
The aim of this study was to evaluate the combination of abdominoplasty with liposuction of both flanks with regards to length of scar, complications, and patient's satisfaction. A retrospective analysis of 35 patients who underwent esthetic abdominoplasty at our institution between 2002 and 2004 was performed. Thirteen patients underwent abdominoplasty with liposuction of both flanks, 22 patients underwent conventional abdominoplasty. Liposuction of the flanks did not increase the rate of complications of the abdominoplasty procedures. We found a tendency toward shorter scars in patients who underwent abdominoplasty combined with liposuction of the flanks. Implementation of 3-dimensional laser surface scanning to objectify the postoperative outcomes, documented a comparable degree of flatness of the achieved body contouring in both procedures. 3-dimensional laser surface scanning can be a valuable tool to objectify assessment of postoperative results.
Resumo:
BACKGROUND: Lipid-lowering therapy is costly but effective at reducing coronary heart disease (CHD) risk. OBJECTIVE: To assess the cost-effectiveness and public health impact of Adult Treatment Panel III (ATP III) guidelines and compare with a range of risk- and age-based alternative strategies. DESIGN: The CHD Policy Model, a Markov-type cost-effectiveness model. DATA SOURCES: National surveys (1999 to 2004), vital statistics (2000), the Framingham Heart Study (1948 to 2000), other published data, and a direct survey of statin costs (2008). TARGET POPULATION: U.S. population age 35 to 85 years. Time Horizon: 2010 to 2040. PERSPECTIVE: Health care system. INTERVENTION: Lowering of low-density lipoprotein cholesterol with HMG-CoA reductase inhibitors (statins). OUTCOME MEASURE: Incremental cost-effectiveness. RESULTS OF BASE-CASE ANALYSIS: Full adherence to ATP III primary prevention guidelines would require starting (9.7 million) or intensifying (1.4 million) statin therapy for 11.1 million adults and would prevent 20,000 myocardial infarctions and 10,000 CHD deaths per year at an annual net cost of $3.6 billion ($42,000/QALY) if low-intensity statins cost $2.11 per pill. The ATP III guidelines would be preferred over alternative strategies if society is willing to pay $50,000/QALY and statins cost $1.54 to $2.21 per pill. At higher statin costs, ATP III is not cost-effective; at lower costs, more liberal statin-prescribing strategies would be preferred; and at costs less than $0.10 per pill, treating all persons with low-density lipoprotein cholesterol levels greater than 3.4 mmol/L (>130 mg/dL) would yield net cost savings. RESULTS OF SENSITIVITY ANALYSIS: Results are sensitive to the assumptions that LDL cholesterol becomes less important as a risk factor with increasing age and that little disutility results from taking a pill every day. LIMITATION: Randomized trial evidence for statin effectiveness is not available for all subgroups. CONCLUSION: The ATP III guidelines are relatively cost-effective and would have a large public health impact if implemented fully in the United States. Alternate strategies may be preferred, however, depending on the cost of statins and how much society is willing to pay for better health outcomes. FUNDING: Flight Attendants' Medical Research Institute and the Swanson Family Fund. The Framingham Heart Study and Framingham Offspring Study are conducted and supported by the National Heart, Lung, and Blood Institute.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
"vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
INTRODUCTION: Although long-term video-EEG monitoring (LVEM) is routinely used to investigate paroxysmal events, short-term video-EEG monitoring (SVEM) lasting <24 h is increasingly recognized as a cost-effective tool. Since, however, relatively few studies addressed the yield of SVEM among different diagnostic groups, we undertook the present study to investigate this aspect. METHODS: We retrospectively analyzed 226 consecutive SVEM recordings over 6 years. All patients were referred because routine EEGs were inconclusive. Patients were classified into 3 suspected diagnostic groups: (1) group with epileptic seizures, (2) group with psychogenic nonepileptic seizures (PNESs), and (3) group with other or undetermined diagnoses. We assessed recording lengths, interictal epileptiform discharges, epileptic seizures, PNESs, and the definitive diagnoses obtained after SVEM. RESULTS: The mean age was 34 (±18.7) years, and the median recording length was 18.6 h. Among the 226 patients, 127 referred for suspected epilepsy - 73 had a diagnosis of epilepsy, none had a diagnosis of PNESs, and 54 had other or undetermined diagnoses post-SVEM. Of the 24 patients with pre-SVEM suspected PNESs, 1 had epilepsy, 12 had PNESs, and 11 had other or undetermined diagnoses. Of the 75 patients with other diagnoses pre-SVEM, 17 had epilepsy, 11 had PNESs, and 47 had other or undetermined diagnoses. After SVEM, 15 patients had definite diagnoses other than epilepsy or PNESs, while in 96 patients, diagnosis remained unclear. Overall, a definitive diagnosis could be reached in 129/226 (57%) patients. CONCLUSIONS: This study demonstrates that in nearly 3/5 patients without a definitive diagnosis after routine EEG, SVEM allowed us to reach a diagnosis. This procedure should be encouraged in this setting, given its time-effectiveness compared with LVEM.
Resumo:
A “policy scepticism” has emerged that challenges the results of conventional regional HEI impact analyses. Its denial of the importance of the expenditure impacts of HEIs appears to be based on a belief in either a binding regional resource constraint or a regional public sector budget constraint. In this paper we provide a systematic critique of this policy scepticism. However, while rejecting the extreme form of policy scepticism, we argue that it is crucial to recognise the importance of the public-sector expenditure constraints that are binding under devolution. We show how conventional impact analyses can be augmented to accommodate regional public sector budget constraints. While our results suggest that conventional impact studies overestimate the expenditure impacts of HEIs, they also demonstrate that the policy scepticism that treats these expenditure effects as irrelevant neglects some key aspects of HEIs, in particular their export intensity.
Resumo:
Comparing each of the twenty Higher Education Institutions (HEIs) in Scotland as separate sectors in an Input-Output table suggests their expenditure patterns are homogenous and that the apparent heterogeneity of their impacts is primarily driven by scale. However, a disaggregation of their income by source reveals a disparity in their dependence upon funding from the devolved Scottish Government and their ability to draw in income/funding from external sources. Acknowledging the binding budget constraint of the Scottish Government and deriving balanced expenditure multipliers reveals large differences in the net-expenditure impact of HEIs upon the Scottish economy, with the source of variation being the origin of income. Applying a novel treatment of student expenditure impacts, identifying the amount of exogenous spending per student, modifies the heterogeneity of the overall expenditure impacts. On balance this suggests that the impacts of impending budget cut-backs will be quite different by institution depending on their sensitivity to public funding. However, predicting the outcome of budget cutbacks at the margin is problematic as we do not know whether public and external incomes are complements or substitutions (and indeed this may vary between individual HEIs).
Resumo:
This paper estimates whether both sourcing knowledge from and/or cooperating on innovation with HEIs (Higher Education Institutions)1 impacts on establishment-level total factor productivity (TFP) using a dataset created by merging the UK government’s Community Innovation Survey (CIS) with the Annual Respondents Database (ARD). It also considers whether higher graduate employment (as a measure of human capital) also impacts positively on TFP at the establishment-level. Many studies have investigated the relationship between university-firm knowledge links and innovation (see, for example, Mansfield, 1991; Becker, 2003; Thorn et al, 2007). Most of these studies find a positive impact. Fewer studies have investigated the impact of university-firm knowledge links on productivity. Belderbos et al. (2004), using the Dutch CIS, find that cooperation with universities has no statistically significant impact on the growth of labour productivity. Medda et al. (2005) find no statistically significant effect of collaborative research undertaken by Italian manufacturing firms and universities on the growth of TFP. Arvanitis et al. (2008), using Swiss data, show that university-firm knowledge and technology transfer has both a direct impact on labour productivity and an indirect impact through its positive impact on innovation. In sum, there is as yet no clear consensus as to the impact of university-firm knowledge links on productivity.