954 resultados para Hidráulica fluvial
Resumo:
This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds
Resumo:
The use of membrane filters in the post-treatment of sewage has been increasingly employed to obtain water quality, applicable to various forms of reuse. Despite the advantages presented using the permeate membranes, such as saving water and reducing water pollution, the concentrate generated in the process ends up being an inconvenience to the deployment of this technology due to lack of sustainable solutions for their management. Thus, the main objective of this research was to evaluate the use of membranes for microfiltration, ultrafiltration, nanofiltration and reverse osmosis concentrated in agriculture, using it as liquid fertilizer. The permeated membranes were also assessed in order to identify activities in which they could be reused. Five configurations were established from four types of membranes, so that each configuration represents a different system. The tests were conducted in batch mode, with triplicate for each configuration. The results indicated that permeated the microfiltration and ultrafiltration can be used in urban areas, in non-potable uses. Have the nanofiltration permeate can be reused in the industry, replacement cooling towers, and other non -potable uses required in the manufacturing unit. The permeate obtained in reverse osmosis met the intended uses for nanofiltration as well as the standards required for boiler feed, adding alkalizing being required to raise the pH to the recommended value. Concentrates generated in nanofiltration and reverse osmosis can be availed as liquid fertilizer in agriculture, but they must be diluted in the irrigation water, in order to adjust the salt concentration allowed for the least tolerant crops patterns
Resumo:
In the state of Rio Grande do Norte (RN), Brazil, there are about 80 sewage treatment systems being the predominant technology waste stabilization ponds. The Baldo s WWTP , due to its location and low availability of area, was designed as a hybrid conventional system (UASB reactor followed by activated sludge with biodiscs) at a tertiary level, being the most advanced WWTP in the State and also with the larger treatment capacity (1620 m3/h) .The paper presents the results of its performance based on samples collections from May to December 2012. Composite samples of the effluent of the grit chamber, UASB reactors, anoxic chambers, aeration tanks and treated effluent were collected weekly, every 4 hours for 24 hours. The results showed that the WWTP effluent presented adequate ranges of temperatures, pH and DO, however removal efficiencies of BOD and TSS were below the predicted by design. The UASB reactors also showed removals of BOD and TSS less than expected, due to the accumulation of sludge in the reactors, which eventually, was washed out in the effluent. The nitrification process was not satisfactory mainly due to problems in the oxygen distribution in the aeration tanks. The removal of ammonia and TKN were high, probably by the assimilation process
Resumo:
The aim of this study is to characterize and evaluate the Macro System of Regional Water Distribution Natal North (RNN) and Southern Regional Natal (RNS), covering 35% and 65% respectively of the Natal-RN City. The terms of the quality and quantity of water (surface and groundwater) were also evaluated in order to adjust the parameters that contribute to proper distribution and control in water reserves. The methodology of the work took place from collecting volumetric data of production capacity and distribution of the two treatment plants for Regional as well as the flow rates of wells. Yet the quantitative capacity of reservation, distribution and consumption of the main reservoirs, population numbers and consumption of members neighborhoods were collected. Data were tabulated and used in computational simulator EPANET to diagnose possible through the water balance, the offers and demands on the water supply system in the neighborhoods of the capital, linking them to specific distribution points. We also evaluated the wells in the levels of nitrate in water consumed. As a result it was found that some neighborhoods in the South Regional Natal, was ranked as critical supply situation: City of Hope, Lagoa Nova and Nova Descoberta, where demand exceeds supply. While in most Northern Regional Natal present deficiency in the supply system as: Lagoa Azul, the Parque dos Coqueiros, igapó, Amarante and Salinas. The rates of nitrate in the city were significant, but manageable with corrective and preventive measures. The averages were 12 mg /l-N in Candelária, 10 mg/l-N in Lagoa Nova, 9 mg/l-N in Satelite, 20 mg/l-N in Gramore and 15 mg/l-N in N. Sra. Apresentação. Therefore proper distribution of water abstracted and implementation of quality control ensures the supply required by the system, associated with preservation of Water Resources of the Metropolitan Region of Natal
Resumo:
The aquatic ecosystems can play a role as carbon-dioxide-source or carbon-dioxide-sink systems due to the high predominance of heterotrophic or autotrophic metabolism. The primary production can strongly affect the carbon balance (CO2) through the consumption of carbon dioxide in the photosynthesis, especially in eutrophic environment, acting as a carbon sink. The present study tested the hypothesis that the eutrophic reservoirs in tropical semi-arid region are carbon dioxide-sink systems due to the high primary productivity presented in these systems. Five Brazilian reservoirs from the semi-arid in the northeast region were monitored monthly during four years (2010 to 2013) with a prolonged drought event identified during the study. The results showed an increasing level of eutrophication over the period of prolonged drought, with the predominance of autotrophy. Significant negative correlations were observed between the partial pressure of CO2 (pCO2) (p<0,001) and chlorophyll-a in the Boqueirão, Passagem das Traíras, Dourado and Gargalheiras reservoirs, showing a pattern of the carbon dioxide-sink systems. However, this pattern was not found in Cruzeta reservoir. In summary, in the tropical semi-arid region, hydrological and morphometric variables can lead to different behaviors of the water-supply reservoirs on the carbon metabolism. The eutrophic reservoirs evaluated showed a negative relationship between pCO2 and Chl-a, which suggests that these water bodies show an autotrophic metabolism and behave as carbon dioxide- sink systems
Resumo:
Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series
Resumo:
In Natal/RN, 68% of the population uses some kind of individual system for their domestic sewers treatment, being that the most used it is septic tank, followed by sumidouro. Every treatment system of sewers, usually used, generates a by-product denominated sludge. That residue presents some components, in its constitution, undesirable under the environmental and sanitary point of view. In such case, to assure that the system treatment has satisfactory results, it is necessary to do the adjusted disposition of the sludge sewage. Several countries are looking for technical alternatives for the use and disposition of residues. Under technical and environmental conditions appropriate, these materials can be used, decreasing the consumption of the natural resources and the treatment need, storage or elimination of the wastes, what decrease the risks created. Some of the alternatives of recycling of the sludge sewage are: the application in the agriculture, in the production of energy and as raw material in the civil construction. This study evaluated asphalt mixtures behavior that partially substituted conventional aggregates by septic tank sludge. The septic tank sludge gave origin to two raw materials called raw sludge and sludge ash. The raw sludge was put as a small aggregate and the sludge ash as filler. In the first experiment it was made a comparison between the mixture with conventional aggregates and the mixtures that replaced sand by raw sludge in the proportions from 5% to 40%. In the second experiment, it was made comparison between mixtures with 1%, 2% and 3% of sludge ash and cement. The stages developed along the study were: physical characterization of the conventional materials; physical, chemistry, thermal, mineralogical characterizations and analysis of environmental risk of the raw sludge; physical characterization and analysis of environmental risk of the sludge ash; analysis of the mixtures performance through its volumetric and mechanical characteristics; forecast of the mixtures susceptibility in the moisture presence. For the grain size composition used and with the percentage asphalt adopted, the mixtures with up to 7,5% of raw sludge in his composition attend to the National Department of Transports Infrastructure (DNIT) specifications. However, in agreement with the mixtures susceptibility in the moisture presence, the mixtures with addition of raw sludge don't present satisfactory acting. In such case, they could be used in arid and semi-arid areas. The raw sludge application in mixtures increased their voids volume and their stability. However, it damaged mixtures adhesiveness. Mixtures with sludge ash and with cement presented similar behavior. However, mixtures with sludge ash presented a better performance than mixtures with cement as for their stability and their tensile strength ratio. The mixture with 1% of sludge ash is better. The wastes studied don't represent environmental risk
Resumo:
Piranhas-Açu basin is a Federal watershed with a drainage area of 43.681,5 km2, sited at Brazilian northeast semi arid, with 60% of your area in Paraiba State and 40% in Rio Grande do Norte State. The main river, Piranhas-Açu, has strategic importance for development of these states, because it s an essential source for many socio-economics activities developed along watercourse. The river s reach between Coremas-Mãe D`água Dam and Armando Ribeiro Gonçalves Dam has many irrigation projects, and supply many riverside cities. All this activities practiced in this river s reach consumes high water volumes. Due the importance of this stream and the necessity of an adequate management, this work aims for an impartial and detailed evaluation of real water supply conditions in this river s reach, by the application of hydrological modeling, including the arrangement of main dams in tributaries, and storage reservoir water balance. The rainfall-discharge model s applied in each sub-basins it was selected the model MODHISA- Hydrological Model of Semi Arid, that is a concentrated model with easy application. The simulation produced 50 years of inflows into the reservoirs, for which, were constructed the guaranties curves; and produced 50 years of synthetic discharge data in relevant points on the river and on its affluents; so it was constructed the permanence curves. Confronting the available discharge with the current and futures volumes of raw water captured in this river s reach, it was verified that de demands have high guaranties. This work concluded that the MODHISA Model is suitable to reproduce the hydrologic characteristics of Piranhas-Açu sub-basins, and showing good results
Resumo:
This dissertation presents a methodology to the optimization of a predial system of cold water distribution. It s about a study of a case applied to the Tropical Buzios Residential Condominium, located in the Búzio s Beach, Nísia Floresta city, the east coast of the Rio Grande do Norte state, twenty kilometers far from Natal. The design of cold water distribution networks according to Norm NBR 5626 of the ABNT - Brazilian Association of Techniques Norms, does not guarantee that the joined solution is the optimal solution of less cost. It s necessary the use of an optimization methodology, that supplies us, between all the possible solutions, the minimum cost solution. In the optimization process of the predial system of water distribution of the Tropical Búzios Condominium, is used Method Granados, that is an iterative algorithm of optimization, based on the Dynamic Programming, that supplies the minimum cost s network, in function of the piezometric quota of the reservoir. For the application of this Method in ramifies networks, is used a program of computer in C language. This process is divided in two stages: attainment of the previous solution and reduction of the piezometric quota of headboard. In the attainment of the previous solution, the minors possible diameters are used that guarantee the limit of maximum speed and the requirements of minimum pressures. The piezometric quota of headboard is raised to guarantee these requirements. In the second stage of the Granados Method, an iterative process is used and it objective is to reduce the quota of headboard gradually, considering the substitution of stretches of the network pipes for the subsequent diameters, considering a minimum addition of the network cost. The diameter change is made in the optimal stretch that presents the lesser Exchange Gradient. The process is locked up when the headboard quota of desired is reached. The optimized network s material costs are calculated, and is made the analysis of the same ones, through the comparison with the conventional network s costs
Resumo:
This work intends to develop an approach based through scientific criteria in the operational diagnosis of ponds of stabilization, starting from analyses accomplished in loco and in laboratory of 78 systems of sewer treatment through ponds of stabilization in the State of Rio Grande do Norte. The objectives of the research are: to map, to evaluate and to diagnose the operational acting of the ponds of stabilization of the state of Rio Grande do Norte, through visits in loco and analyses laboratory; to build a SIG, through the map rain, locate the points of releases of sewages of the systems of existent ponds in Rio Grande do Norte, as well as operational data and his/her respective efficiency diagnosis in the removal of BOD and Coliforms Termotolerantes; to evaluate, in real scale, three systems of ponds of stabilization of RN in the operational efficiency for the parameters BOD5, COD, pH, Temperature, OD and Coliforms Termotolerantes. Of 78 ETEs of appraised RN just, 9% or 7 had maximum concepts in what concerns the removal of BOD and Coliforms Termotolerantes and 41% or 32, they had the worst concepts in term of operational efficiency. The flowing concentrations ETEs of RN of BOD and Coliforms were of 410mg/L and 2,50x107UFC/100ml, the predominant configuration is of the type F1+M1+M2, the relationship BOD/COD revealed for the sewer tributary characteristic biodegradable high. For the study of case of 3 ETEs, the best operational efficiencies in decreasing order were: Cidade (Municipal district), it Roça (State) and São Miguel (SAAE). The removals of final BOD were 51,6mg/L; 108,27mg/L and 62,6mg/L, tends efficiency of 82%; 74% and 81%. In term of coliforms removal in the final effluentes were 1,90x103UFC/100ml; 1,50x104UFC/100ml and 3,10x104UFC/100ml, tends efficiencies of 99,99%; 99,95% and 99,90%. In what it concerns the practice of agricultural reúso of cultures consumed raw, none of 3 ETEs assisted the parameters of the Resolution CONAMA 357/05, for other reúso practices, all assisted the categories B and C of OMS. For release in body receiving ETE Cidade just, they assist the demands of the resolution of CONAMA 357/05, by study of purification solemnity of the receiving body. The maintenance lack and operation; exclusive operator in ETEs and operation knowledge was the contributory factors for the operational fall in appraised ETEs of RN
Resumo:
Bivalves mollusks fossils of Bauru Group (Late Cretaceous, Bauru Basin) deposited in scientific collections and collected in outcrops from Monte Alto municipality, São Paulo, are analyzed in their taphonomy. The preservation of recrystallized individual in carbonatic matrix indicates substrate remobilization by unidirectional energetic event in fluvial discharge. The specimens with conjugated valves possess internal sediment similar to the external indicating low exposition to Taphonomical Active Zone, suggesting a bioclastic low time-averaging. The truncate and fragmented posterior portion of specimens from scientific collections is probably related to the incapacity of the taxa to reburrowing the substrate in drowning periods. Both taphonomic patterns corroborate evidences of a fluvial paleoenvironment in the Bauru Group.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Tubos de aço são transportados diariamente em todo o mundo, por caminhão, trem ou navio. Conseqüentemente, danos de transporte, podem ocorrer com freqüência e regularidade. O tipo de dano particular selecionado para este estudo foi o de trinca por fadiga, o qual é considerado como um dos mais críticos. Neste trabalho foram estudados tubos de aço fabricados de acordo com os requisitos da norma API 5L [1]. Foram efetuadas caracterizações químicas, mecânicas e metalográficas de um tubo com diâmetro 609,6 mm e espessura 15,87 mm grau X-65. A simulação do transporte por navio de tubos de aço foi feita submetendo-se seções de tubo com comprimento igual a 0,1 metro, a ciclos de fadiga por meio de máquina servo-hidráulica. Foi possível concluir que em tubos soldados, a região adjacente ao cordão de solda é a mais crítica, e que quando o posicionamento do tubo na carga é efetuado de maneira que a solda fique apoiada sobre alguma superfície rígida, a ocorrência de trinca por fadiga torna-se possível principalmente se os procedimentos de manuseio, carregamento e transporte não forem executados da maneira como recomendada pelos fabricantes de tubos e pela norma API [2].
Resumo:
O objetivo deste trabalho foi monitorar o desempenho de remoção de nitrogênio amoniacal no tratamento das águas residuárias da produção intensiva de tilápia nilótica em sistema com recirculação de água. O sistema foi constituído por um sedimentador convencional e um reator aeróbio de leito fluidizado trifásico com circulação, operados com tempos de detenção hidráulica de 176.4 e 11.9 minutos respectivamente. O meio suporte utilizado no reator foi o carvão ativado granular com densidade aparente de 1.64 g/cm3 e tamanho efetivo de 0.34 mm; a concentração do meio suporte no reator foi mantida constante em 80 g/L. A eficiência média de remoção do nitrogênio amoniacal total foi de 41.2%. O sistema avaliado é uma alternativa efetiva para o reuso da água em sistemas de recirculação para aqüicultura. Embora a variabilidade das concentrações do nitrogênio amoniacal afluente cujo valor médio foi de 0.136 mg/L, o efluente do reator conservou as características de qualidade da água estáveis, com concentrações médias de nitrogênio amoniacal de 0.079 mg/L e do oxigênio dissolvido de 6.70 mg/L, recomendáveis para a criação dos peixes e nas faixas de valores permitidos pela legislação Brasileira (Resolução CONAMA No. 357 de março 5 de 2005) para lançamento de efluentes finais nos corpos de água receptores.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)