984 resultados para Heart surgery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial contractility depends on several mechanisms such as coronary perfusion pressure (CPP) and flow as well as on a1-adrenoceptor stimulation. Both effects occur during the sympathetic stimulation mediated by norepinephrine. Norepinephrine increases force development in the heart and produces vasoconstriction increasing arterial pressure and, in turn, CPP. The contribution of each of these factors to the increase in myocardial performance needs to be clarified. Thus, in the present study we used two protocols: in the first we measured mean arterial pressure, left ventricular pressure and rate of rise of left ventricular pressure development in anesthetized rats (N = 10) submitted to phenylephrine (PE) stimulation before and after propranolol plus atropine treatment. These observations showed that in vivo a1-adrenergic stimulation increases left ventricular-developed pressure (P<0.05) together with arterial blood pressure (P<0.05). In the second protocol, we measured left ventricular isovolumic systolic pressure (ISP) and CPP in Langendorff constant flow-perfused hearts. The hearts (N = 7) were perfused with increasing flow rates under control conditions and PE or PE + nitroprusside (NP). Both CPP and ISP increased (P<0.01) as a function of flow. CPP changes were not affected by drug treatment but ISP increased (P<0.01). The largest ISP increase was obtained with PE + NP treatment (P<0.01). The results suggest that both mechanisms, i.e., direct stimulation of myocardial a1-adrenoceptors and increased flow, increased cardiac performance acting simultaneously and synergistically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Determinar as alterações de atividade da enzima conversora de angiotensina (ECA) no coração com infarto do miocárdio (IM) e comparar os efeitos do captopril e losartan em parâmetros morfológicos e funcionais de ratos com IM. Métodos: O IM foi produzido em ratos Wistar por ligadura de ramos da artéria coronária esquerda. Os controles (Con) foram submetidos a uma cirurgia fictícia. Animais com IM e Con foram tratados com captopril (30mg/kg/dia) ou losartan (15mg/kg/dia) e estudados 30 dias após, determinando-se a atividade da ECA nos ventrículos direito (VD) e esquerdo (VE), as alterações hemodinâmicas e as concentrações de hidroxiprolina (OH-Pro) e proteína total no VD e VE. Resultados: A atividade da ECA aumentou no VD (+25%) e VE (+70%) após IM. A maior atividade foi observada na cicatriz fibrótica, onde atingiu cerca de 4,5 vezes a do músculo do VE que sobreviveu ao IM (420±68 vs 94±8nmoles/g/min; P<0,01). O IM determinou aumento da pressão diastólica final e hipertrofia do VD e VE. Captopril e losartan foram igualmente eficazes em atenuar a hipertrofia e o aumento da pré-carga. O captopril também atenuou o aumento de OH-Pro no VD e VE após IM. O IM reduziu a concentração de proteína principalmente no músculo de VE, efeito esse acentuado pelo captopril. Conclusão: A grande atividade da ECA na cicatriz deve produzir altas concentrações de angiotensina II (AII) no sangue que drena da cicatriz. Os efeitos dos inibidores da ECA seriam decorrentes, principalmente, da redução de geração local de AII, e não de aumento de cininas, uma vez que captopril e losartan exerceram efeitos similares no remodelamento pós-infarto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laparoscopy is a surgical procedure on which operations in the abdomen are performed through small incisions using several specialized instruments. The laparoscopic surgery success greatly depends on surgeon skills and training. To achieve these technical high-standards, different apprenticeship methods have been developed, many based on in vivo training, an approach that involves high costs and complex setup procedures. This paper explores Virtual Reality (VR) simulation as an alternative for novice surgeons training. Even though several simulators are available on the market claiming successful training experiences, their use is extremely limited due to the economic costs involved. In this work, we present a low-cost laparoscopy simulator able to monitor and assist the trainee’s surgical movements. The developed prototype consists of a set of inexpensive sensors, namely an accelerometer, a gyroscope, a magnetometer and a flex sensor, attached to specific laparoscopic instruments. Our approach allows repeated assisted training of an exercise, without time constraints or additional costs, since no human artificial model is needed. A case study of our simulator applied to instrument manipulation practice (hand-eye coordination) is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of cardiac resynchronization therapy (CRT) in the health-related quality of life (HRQL) are largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions that constitute HRQL are still a matter of discussion. Objective: To evaluate the impact of CRT on the HRQL of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT. Methods: 43 patients, submitted to successful implantation of CRT, were evaluated in hospital just before intervention and in the outpatient clinic within 6 months after CRT. HRQL was analyzed based on the Kansas City Cardiomyopathy Questionnaire (KCCQ). Patients were classified as super-responders (ejection fraction of left ventricle - LVEF - ≥45% post-CRT), n=15, responders (sustained improvement in functional class and LVEF increased by 15%), n=19, and non-responders (no clinical or LVEF improvement), n=9. Results: In the group of super-responders, CRT was associated with an improvement in HRQL for the various fields and sums assessed (ρ<0.05); in responders, CRT has been associated with an improvement of HRQL in the various fields and sums, except in the self-efficacy dimension (ρ<0.05); in non-responders, CRT was not associated with improvement of HRQL. Conclusion: In a population with severe CHF undergoing CRT, the patients with clinical and echocardiographic positive response, obtained a favorable impact in all dimensions of HRQL, while the group without response to CRT showed no improvement. These data reinforces the importance of HRQL as a multidimensional tool for assessment of benefits in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A insuficiência cardíaca afecta cerca de 261 mil pessoas em Portugal constituindo um problema de saúde pública. Pretendemos avaliar aspectos associados à recuperação do estado de saúde nesta síndrome, em particular a esperança, o afecto e a felicidade. Recorremos a um estudo longitudinal com 128 indivíduos sintomáticos com má fracção de ejecção do ventrículo esquerdo. Utilizámos um questionário para caracterizar os aspectos sóciodemográficos, clínicos e funcionais, o Kansas City Cardiomiopathy Questionnaire (KCCQ) para avaliar a qualidade de vida, a Subjective Hapiness Scale (SHS) para a felicidade, a HOPE Scale (HOPE) para a esperança e a Positive And Negative Afect Schedule (PANAS) para o afecto. Os questionários de caracterização sócio-demográfica, clínica e funcional, KCCQ e o SHS foram aplicados em três momentos: no internamento, prévio à instituição de terapêutica médica na sua totalidade e ao terceiro e sexto mês após a intervenção médica, na consulta externa. A maioria dos participantes eram homens em classe III da classificação da New York Heart Association com etiologia isquémica. No internamento e antes da terapêutica médica, observámos que a esperança, a felicidade e o afecto se relacionaram com a qualidade de vida, a felicidade e o afecto positivo com a esperança. No período avaliado foram submetidos a: terapia de ressincronização cardíaca (n=52), cardioversor-desfibrilhador implantável (n=44), cirurgia valvular com revascularização do miocárdio (n=14), optimização terapêutica farmacológica (n=10), transplante cardíaco (n=8). Foram significativos os resultados da qualidade de vida, da classificação da New York Heart Association, do exercício físico, da fracção de ejecção do ventrículo esquerdo e das arritmias cardíacas (estrasístoles e taquicardias ventriculares). A felicidade foi preditora da qualidade de vida e da funcionalidade. O afecto negativo foi preditor da satisfação com a insuficiência cardíaca. Concluímos da importância das variáveis positivas a par dos procedimentos médicos no tratamento das pessoas com insuficiência cardíaca. ABSTRACT - Heart failure affects about 261 000 people in Portugal constituting a public health problem. We intend to evaluate aspects of the health recovery in this syndrome, in particular hope, affection and happiness. We used a longitudinal study with 128 symptomatic patients with poor ejection fraction of left ventricle. We used a questionnaire to characterize the socio-demographic, clinical and functional aspects, the Kansas City Cardiomiopathy Questionnaire (KCCQ) to assess the quality of life, the Subjective Happiness Scale (SHS) for happiness, the HOPE Scale (HOPE) for hope and the Positive And Negative Affect Schedule (PANAS) for affection. The questionnaires of sociodemographic, clinical and functional KCCQ and SHS were applied on three occasions: on admission, prior to the execution of medical therapy in its totality and in the third and sixth months after medical intervention in the outpatient. Most of the participants were men in Class III New York Heart Association classification with ischemic etiology. At admission and before medical therapy, we observed that the hope, happiness and affection were related to the quality of life, happiness and positive affect with hope. Over the studied period were submitted to: cardiac resynchronization therapy (n=52), implantable cardioverter-defibrillator (n=44), valvular surgery with coronary artery bypass graft surgery (n=14), optimizing drug therapy (n=10), heart transplant (n=8). The significant results were the quality of life, the New York Heart Association classification, the exercise, the ejection fraction and left ventricular cardiac arrhythmias (ventricular tachycardia and estrasistoles). Happiness was a predictor of quality of life and functionality. The negative affect was a predictor of satisfaction with heart failure. We concluded that the positive variables and the medical procedures were important in treating people with heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rise in ischemic heart disease(IHD) mortality occurring mostly during the first half of the 20th century is usually associated with economic development and its consequences for people's lifestyles. On the basis of historical evidence, it is postulated that a previous IHD epidemic cycle may have occurred in England and Wales towards the turn of the nineteenth century. The implications of this on causal theories and current etiological research on atherosclerosis are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of cardiac resynchronization therapy (CRT) in the quality of life have been largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions of quality of life is still a matter of discussion. Objective: to evaluate the impact of CRT on the quality of life of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Meeting the actual role of positive psychology, begins to be recognized the relation of positive variables with health. Objective: To know the relation of happiness, hope and affection with quality of life in individuals with heart failure. Population and Methodology: 128 individuals with heart failure, 98 men and 30 women, 61.9±12,1 years of age, 6,6±3,9 years in school and 74,2% retired because of this disease. 56,3% were in Class III of New York Heart Association, with poor left ventricular ejection fraction (25,3±6,2%). The clinical history was of 9,4±8,5 years for this heart disease and had at least one hospitalization due to heart failure with 51,6% having ischemic heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Meeting the actual role of positive psychology, begins to be recognized the contribution of positive variables in health outcomes. Objective: To know the contribution of happiness, hope and affection individually and as a whole in the quality of life and functionality of individuals with heart failure. Population and Methodology: 128 individuals with heart failure, 98 men and 30 women, 61.9±12,1 years of age, 6,6±3,9 years of school and 74,2% retired because of this disease. 56,3% were in Class III of New York Heart Association, with poor left ventricular ejection fraction (25,3±6,2%). The clinical history was of 9,4±8,5 years for this heart disease and had at least one hospitalization due to heart failure with 51,6% having ischemic heart disease.