988 resultados para Hardness testing
Resumo:
Scepticism over stated preference surveys conducted online revolves around the concerns over “professional respondents” who might rush through the questionnaire without sufficiently considering the information provided. To gain insight on the validity of this phenomenon and test the effect of response time on choice randomness, this study makes use of a recently conducted choice experiment survey on ecological and amenity effects of an offshore windfarm in the UK. The positive relationship between self-rated and inferred attribute attendance and response time is taken as evidence for a link between response time and cognitive effort. Subsequently, the generalised multinomial logit model is employed to test the effect of response time on scale, which indicates the weight of the deterministic relative to the error component in the random utility model. Results show that longer response time increases scale, i.e. decreases choice randomness. This positive scale effect of response time is further found to be non-linear and wear off at some point beyond which extreme response time decreases scale. While response time does not systematically affect welfare estimates, higher response time increases the precision of such estimates. These effects persist when self-reported choice certainty is controlled for. Implications of the results for online stated preference surveys and further research are discussed.
Resumo:
This chapter describes methods for testing biocides against microbes. The first part describes a method using flow cytometry to test biocides against multispecies communities of planktonic microbial assemblage and Part 2 describes methods to test biocides against both single and multispecies biofilms.
Resumo:
The environmental attractions of air-cycle refrigeration are considerable. Following a thermodynamic design analysis, an air-cycle demonstrator plant was constructed within the restricted physical envelope of an existing Thermo King SL200 trailer refrigeration unit. This unique plant operated satisfactorily, delivering sustainable cooling for refrigerated trailers using a completely natural and safe working fluid. The full load capacity of the air-cycle unit at -20 °C was 7,8 kW, 8% greater than the equivalent vapour-cycle unit, but the fuel consumption of the air-cycle plant was excessively high. However, at part load operation the disparity in fuel consumption dropped from approximately 200% to around 80%. The components used in the air-cycle demonstrator were not optimised and considerable potential exists for efficiency improvements, possibly to the point where the air-cycle system could rival the efficiency of the standard vapour-cycle system at part-load operation, which represents the biggest proportion of operating time for most units.