882 resultados para HEAVY DRINKING


Relevância:

20.00% 20.00%

Publicador:

Resumo:

2-Mercaptobenzothiazole loaded on previously treated clay was prepared, characterized and used for sorption and preconcentration of Hg(II), Pb(II), Zn(II), Cd(II), Cu(II) and Mn(II) from an aqueous solution. The support used was a natural clay previously treated with sulphuric acid solution. Adsorption isotherms of metal ions from aqueous solutions as function of pH were studied at 298 K. Conditions for quantitative retention and elution were established for each metal by batch and column methods. The chemically treated clay was very selective to Hg(II) in solution in which Zn(II), Cd(II), Pb(II), Cu(II) and Mn(II) were also present. © 1995.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We estimate the cross-section for glueball production in peripheral heavy-ion collisions through two-photon and double-Pomeron exchange, at energies that will be available at RHIC and LHC. Glueballs will be produced at large rates, opening the possibility to study decays with very small branching ratios. In particular, we discuss the possibility of observing the subprocess γγ(PP) → G → γγ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonlocal interactions are an intrinsically quantum phenomenon. In this work we point out that, in the context of heavy ions, such interactions can be studied through the refractive elastic scattering of these systems at intermediate energies. We show that most of the observed energy dependence of the local equivalent bare potential arises from the exchange nonlocality. The nonlocality parameter extracted from the data was found to be very close to the one obtained from folding models. The effective mass of the colliding, heavy-ion, system was found to be close to the nucleon effective mass in nuclear matter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, an in situ derivatization and extraction method for the determination of pentachlorophenol (PCP) has been applied successfully in the analysis of water samples. The PCP derivative analysis was performed by gas-liquid chromatography with electron capture detection. The limit of detection of the method is 1 μg/L and recoveries averaged 78-108% for PCP acetate at levels of 2, 10 and 20 μg/L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cellulose phosphate (CELLPHOS) was studied as a collector for analytical preconcentration of traces of Cd(II), Cr(III), Cu(II) and Ni(II) from aqueous sample solution. It has been proved that using chromatographic columns packed with CELLPHOS for preconcentration and 1.0 mol 1 -1 HCl for elution the adsorbed analytes are quantitatively enriched. An enrichment factor of 20 (100 ml sample, 5 ml concentrate) was achieved by this separation procedure, which was applied to a series of water analyses (river, sea, bog water).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magneto-optical rotation was measured at room temperature for glasses containing Bi2O3-CdO-GeO2 (BCG), and Bi2O3-PbO-GeO2-B2O3 (BPGP). A pulsed magnetic field between 50 and 80 KG was used to measure Faraday rotation at 632.8 nm as a function of the concentration of Bi and Cd for BCG and Bi and Pb for BPGB. Verdet constant as high as 0.162 min G-1 cm-1 at 632.8 nm for the BPGB sample with the highest concentrations of Bi and Cd was found. Verdet constant increases linearly with the heavy-metal concentration for the BPGB whereas it reaches some saturation for the BCG system. Measurements of the magneto-optical rotation at other wavelengths in the visible and the refractive index at 632.8 nm are also reported. © 1998 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to analyze the prospective alterations of the testis and epididymis in a defined strain of alcoholic rats in order to contribute to our understanding of the effects of chronic alcoholism on reproduction. The testis and epididymis of the animals were submitted to morphological analysis by macroscopy, light microscopy and electron microscopy and to morphometric analysis. The UCh rats showed atrophy of the epithelium and reduction of testis and epididymis weight, liver hypertrophy and fat infiltration and alterations of the hypothalamus-pituitary axis. Ethanol induces changes in the weight and in the epithelium of the testis and epididymis and in the hypothalamus-pituitary axis of the UCh rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We estimate the cross sections for the production of resonances, pion pairs, and a central cluster of hadrons in peripheral heavy-ion collisions through two-photon and double-pomeron exchange, at energies that will be available at the Relativistic Heavy Ion Collider (RHIC) and the Large Hadron Collider (LHC). The effect of the impact parameter in the diffractive reactions is introduced, and by imposing the condition for realistic peripheral collisions we verify that in the case of very heavy ions the pomeron-pomeron contribution is indeed smaller than the electromagnetic one. However, they give a non-negligible background in the collision of light ions. This diffractive background will be more important at RHIC than at LHC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic alcoholism alters reproduction and therefore may be responsible for alterations of prostate and seminal vesicles, which are the subject of this analysis in UCh ethanol-drinking rats. The prostate and seminal vesicles of 20 animals were submitted to macroscopic, light microscopy, electron microscopy and morphometric analysis. The UCh rats showed atrophy of the epithelium and reduction of the weight of the prostate and seminal vesicle, liver hypertrophy and fat infiltration and alterations of the hypothalamus-pituitary axis. Ethanol induces changes in the weight and in the epithelium of prostate and seminal vesicles and hypothalamus-pituitary axis of UCh rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss processes leading to two photon final states in peripheral heavy ion collisions at RHIC. Due to the large photon luminosity we show that the continuum subprocess γγ→ γγ can be observed with a large number of events. We study this reaction when it is intermediated by a resonance made of quarks or gluons and discuss its interplay with the continuum process, verifying that in several cases the resonant process overwhelms the continuum one. It also investigated the possibility of observing a scalar resonance (the σ meson) in this process. Assuming for the σ the mass and total decay width values recently reported by the E791 Collaboration we show that RHIC may detect this particle in its two photon decay mode if its partial photonic decay width is of the order of the ones discussed in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for the direct and simultaneous determination of As, Cu, Mn, Sb, and Se in drinking water by electrothermal atomic absorption spectrometry (ETAAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of analytes during the pyrolysis and atomization stages was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3 and 1 + 1 (v/v) diluted water using mixtures of Pd(NO3)2 + Mg(NO3)2 as the chemical modifier. With 5 μg Pd + 3 μg Mg as the modifier, the pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1400°C and 2100°C, respectively, and 20 μL of the water sample (sample + 0.28 mol L-1 HNO3, 1 + 1, v/v), dispensed into the graphite tube, analytical curves were established ranging from 5.00 -50.0 μg L-1 for As, Sb, Se; 10.0 - 100 μg L-1 for Cu; and 20.0 - 200 μg L-1 for Mn. The characteristic masses were around 39 pg As, 17 pg Cu, 60 pg Mn, 43 pg Sb, and 45 pg Se, and the lifetime of the tube was around 500 firings. The limits of detection (LOD) based on integrated absorbance (0.7 μg L-1 As, 0.2 μg L-1 Cu, 0.6 μg L-1 Mn, 0.3 μg L-1 Sb, 0.9 μg L-1 Se) exceeded the requirements of the Brazilian Food Regulations (decree # 310-ANVS from the Health Department), which established the maximum permissible level for As, Cu, Mn, Sb, and Se at 50 μg L-1, 1000 μg L-1, 2000 μg L-1, 5 μg L-1, and 50 μg L-1, respectively. The relative standard deviations (n = 12) were typically < 5.3% for As, < 0.5% for Cu, < 2.1% for Mn, < 11.7% for Sb, and < 9.2% for Se. The recoveries of As, Cu, Mn, Sb, and Se added to the mineral water samples varied from 102-111%, 91-107%, 92-109%, 89-97%, and 101-109%, respectively. Accuracy for the determination of As, Cu, Mn, Sb, and Se was checked using standard reference materials NIST SRM 1640 - Trace Elements in Natural Water, NIST SRM 1643d - Trace Elements in Water, and 10 mineral water samples. A paired t-test showed that the results were in agreement with the certified values of the standard reference materials at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic alcoholism alters reproduction and therefore may be responsible for alterations of vas deferens, which are the subject of this analysis in UCh ethanol-drinking rats. The proximal and distal segments of the vas deferens of 20 animals were submitted to macroscopic, light microscopy, electron microscopy and morphometric analysis. The UCh rats showed atrophy of the epithelium of the vas deferens and alterations of the hypothalamus-pituitary axis. Ethanol induces changes in the epithelium of the vas deferens and hypothalamus-pituitary axis of UCh rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heavy metal oxide (HMO) glasses have received special attention due to their optical, electrical and magnetic properties. The problem with these glasses is their corrosive nature. In this work, three ceramic crucibles (Al 2O 3, SnO 2 and ZrO 2) were tested in the melting of the system 40 PbO-35 BiO 1.5-25 GaO 1.5 (cation-%). After glass melting, crucibles were transversally cut and analyzed by scanning electronic microscopy (SEM), coupled to microanalysis by energy dispersive spectroscopy (EDS). Results indicated that zirconia crucibles presented the highest corrosion, probably due to its smallest grain size. Tin oxide crucibles presented a low corrosion with small penetration of the glass into the crucible. This way, these crucibles are an interesting alternative to melt corrosive glasses in instead of gold or platinum crucibles. It is important to emphasize the lower cost of tin oxide crucibles, compared to gold or platinum ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to their low cost and high resistance to corrosion, ceramic crucibles can be used for the melting of PBG glasses (PbO-BiO 1.5GaO 1.5). These glasses present good window transmission from ultra-violet to infrared, making their use as optical fibres promising. However, their disadvantage is the high reactivity, leading to the corrosion of different crucibles, including gold and platinum ones. In this work, the corrosion of Al 2O 3, SnO 2 and ZrO 2 crucibles after melting at temperatures varying from 850 to 1000°C, was evaluated by Scanning Electronic Microscopy (SEM) in conjunction with microanalysis by EDS. The lead diffusion profile in the crucible material was obtained. Diffusion coefficients were calculated according to the Fick and Fisher theories. Results indicated that the different crucibles presented similar behaviour: in the region near the interface, diffusion occurs in the volumetric way and in regions away from the interface, diffusion occurs through grain boundary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of biosolids in horticulture could contribute to recycle residues produced by men. This study analyzed concentrations of Cu, Mn and Zn in the compost during fermentation, in the soil amended with the composts and in the tomato plant materials. Five composts were produced using sugar-cane bagasse, biosolid and cattle manure in the proportions: 75-0-25; 75-12.5-12.5; 75-25-0; 50-50- 0 and 0-100-0 (composts with 0; 12.5; 25; 50 and 100% biosolid), respectively. These composts were used in an experiment with 6 treatments (the 5 composts and a control with mineral fertilization) in a design of randomized blocks with a split plot design. The control and the treatment of 0% biosolid received inorganic nitrogen. All the treatments received the same amount of N, P and K. Two tomato plants were cultivated in each 24 L pot, in a greenhouse at the Technology Department of the Faculdade de Ciências Agrárias e Veterinárias of the Universidade Estadual Paulista in Jaboticabal County, São Paulo State, Brazil. The concentrations of Cu, Mn and Zn were evaluated in the compost 7, 27, 57, 97 and 127 days after composting began, in the soil 0 and 164 days after the compost applied, and in the plants. Compost, soil and plant samples were subjected to digestion with HNO3, H 2O2 and HCl and the metals were determined by AAS. There were positive and significant correlations between Mn in the compost and Mn uptake by the plant (0.46 p>0.05), and between Zn in the compost and Zn concentration in the plant (0.78 p>0.05). Cu, Mn and Zn concentrations increased during composting. The biosolid in the compost supplied Cu and Zn to tomato plants, and the cattle manure supplied Mn to the plants.