917 resultados para Façades of buildings
Resumo:
Urban systems consist of several interlinked sub-systems - social, economic, institutional and environmental – each representing a complex system of its own and affecting all the others at various structural and functional levels. An urban system is represented by a number of “human” agents, such as individuals and households, and “non-human” agents, such as buildings, establishments, transports, vehicles and infrastructures. These two categories of agents interact among them and simultaneously produce impact on the system they interact with. Try to understand the type of interactions, their spatial and temporal localisation to allow a very detailed simulation trough models, turn out to be a great effort and is the topic this research deals with. An analysis of urban system complexity is here presented and a state of the art review about the field of urban models is provided. Finally, six international models - MATSim, MobiSim, ANTONIN, TRANSIMS, UrbanSim, ILUTE - are illustrated and then compared.
Resumo:
La presente tesi tratta il comportamento meccanico delle fasce di piano in muratura composite. Con tale termine ci si riferisce alle fasce di piano che hanno al di sotto un elemento portante in conglomerato cementizio armato, come ad esempio cordoli o solai. Assieme ai maschi murari, le fasce di piano costituiscono gli elementi portanti di una parete in muratura. Tuttavia, in caso di analisi sismica di un edificio in muratura, l’effetto fornito da tali elementi è trascurato e si considera solamente il contributo dei maschi murari. Ciò è dovuto anche alla scarsa conoscenza che ancora oggi si possiede sul loro comportamento meccanico. Per questo motivo diversi gruppi di ricerca tutt’ora sono impegnati in tale studio. In particolare, il lavoro di questa tesi, s’inserisce nel più ampio progetto di ricerca condotto dalla professoressa Katrin Beyer, direttrice del Laboratorio di Ingegneria Sismica e Dinamica Strutturale del Politecnico di Losanna (Svizzera).
Resumo:
In this dissertation the influence of a precast concrete cladding system on structural robustness of a multi-storey steel-composite building is studied. The analysis follows the well-established framework developed at Imperial College London for the appraisal of robustness of multi-storey buildings. For this scope a simplified nonlinear model of a typical precast concrete façade-system is developed. Particular attention is given to the connection system between structural frame and panel, recognised as the driving component of the nonlinear behaviour of the façade-system. Only connections involved in the gravity load path are evaluated (bearing connections). Together with standard connection, a newly proposed system (Slotted Bearing Connection) is designed to achieve a more ductile behaviour of the panel-connection system. A parametric study involving the dimensions of panel-connection components is developed to search for an optimal configuration of the bearing connection. From the appraisal of structural robustness of the panelised frame it is found that the standard connection systems may reduce the robustness of a multi-storey frame due to a poor ductile behaviour while the newly proposed connection is able to guarantee an enhanced response to the panelised multi-storey frame thanks to a higher ductility.
Resumo:
With the outlook of improving seismic vulnerability assessment for the city of Bishkek (Kyrgyzstan), the global dynamic behaviour of four nine-storey r.c. large-panel buildings in elastic regime is studied. The four buildings were built during the Soviet era within a serial production system. Since they all belong to the same series, they have very similar geometries both in plan and in height. Firstly, ambient vibration measurements are performed in the four buildings. The data analysis composed of discrete Fourier transform, modal analysis (frequency domain decomposition) and deconvolution interferometry, yields the modal characteristics and an estimate of the linear impulse response function for the structures of the four buildings. Then, finite element models are set up for all four buildings and the results of the numerical modal analysis are compared with the experimental ones. The numerical models are finally calibrated considering the first three global modes and their results match the experimental ones with an error of less then 20%.
Resumo:
In recent years, advanced metering infrastructure (AMI) has been the main research focus due to the traditional power grid has been restricted to meet development requirements. There has been an ongoing effort to increase the number of AMI devices that provide real-time data readings to improve system observability. Deployed AMI across distribution secondary networks provides load and consumption information for individual households which can improve grid management. Significant upgrade costs associated with retrofitting existing meters with network-capable sensing can be made more economical by using image processing methods to extract usage information from images of the existing meters. This thesis presents a new solution that uses online data exchange of power consumption information to a cloud server without modifying the existing electromechanical analog meters. In this framework, application of a systematic approach to extract energy data from images replaces the manual reading process. One case study illustrates the digital imaging approach is compared to the averages determined by visual readings over a one-month period.
Diffusion Dynamics of Energy Efficient Buildings. Actor's Cognitive Maps of the Construction Process
Resumo:
Consecrated in 1297 as the monastery church of the four years earlier founded St. Catherine’s monastery, the Gothic Church of St. Catherine was largely destroyed in a devastating bombing raid on January 2nd 1945. To counteract the process of disintegration, the departments of geo-information and lower monument protection authority of the City of Nuremburg decided to getting done a three dimensional building model of the Church of St. Catherine’s. A heterogeneous set of data was used for preparation of a parametric architectural model. In effect the modeling of historic buildings can profit from the so called BIM method (Building Information Modeling), as the necessary structuring of the basic data renders it into very sustainable information. The resulting model is perfectly suited to deliver a vivid impression of the interior and exterior of this former mendicant orders’ church to present observers.
Resumo:
A historical account is given of the Houston Academy of Medicine--Texas Medical Center Library within its Texas Medical Center setting in Houston, Texas. Outlined are planning, financing, and construction of the new library, which consists in part of new building and in part of renovated interiors of an old building originally completed in 1954. A concise picture is given of the new library's interiors, showing its functional success for users and employees alike. An architectural summary is appended showing gross and net footages, source of funds, costs and capacities.
Resumo:
One of the most significant aspects of a building’s acoustic behavior is the airborne sound insulation of the room façades, since this determines the protection of its inhabitants against environmental noise. For this reason, authorities in most countries have established in their acoustic regulations for buildings the minimum value of sound insulation that must be respected for façades. In order to verify compliance with legal requirements it is usual to perform acoustic measurements in the finished buildings and then compare the measurement results with the established limits. Since there is always a certain measurement uncertainty, this uncertainty must be calculated and taken into account in order to ensure compliance with specifications. The most commonly used method for measuring sound insulation on façades is the so-called Global Loudspeaker Method, specified in ISO 140-5:1998. This method uses a loudspeaker placed outside the building as a sound source. The loudspeaker directivity has a significant influence on the measurement results, and these results may change noticeably by choosing different loudspeakers, even though they all fulfill the directivity requirements of ISO 140-5. This work analyzes the influence of the loudspeaker directivity on the results of façade sound insulation measurement, and determines its contribution to measurement uncertainty. The theoretical analysis is experimentally validated by means of an intermediate precision test according to ISO 5725-3:1994, which compares the values of sound insulation obtained for a façade using various loudspeakers with different directivities
Resumo:
The façade is the visible part of a building, and generally consists of various different constructive systems. The sound reduction index of the closing elements for the openings on a room’s façade is a determining factor in the sound insulation from airborne noise inside the space. Windows are the transparent part of the façade, and to improve their thermal behaviour and control solar radiation, they are often fitted with a series of external and internal protections such as shutters, slats and blinds. This work contains a summary of studies carried out using field measurements of airborne sound insulation on façades in rooms, in application of the standard UNE-EN ISO 140-5:1999. In all the rooms the windows were fitted with shutter boxes and rolling shutters, and the acoustic tests were made with the shutter in two positions (extended and fully retracted). The results were analysed considering the window opening system (openable or sliding) and the type of glass pane (monolithic or insulating glass unit, IGU). In the case of sliding windows, the airborne sound insulation of façades is greater when the shutter is extended than when it is retracted, and this should be taken into account when applying the aforementioned standard.
Resumo:
Nearly 3000 slaughterhouses (74% of them public facilities) were built in Spain during the last decades of the nineteenth century and the first half of the twentieth century. The need to comply with new technical requirements and regulations on the hygiene of the meat passed in the 70s and the gradual replacement of public facilities by larger and more modern private slaughterhouses have subsequently led to the closure and abandonment of many of these buildings. Public slaughterhouses generally consisted of several single-storey and open-plan buildings located around a courtyard. Although originally they were preferably located on the outskirts of the towns, many slaughterhouses are now placed inside the built up areas, due to the urban development. The present work aims to contribute to a better understanding of these agro-industrial buildings and to provide ideas for their conservation and reuse. A review on the historical evolution and the architectural features of the public slaughterhouses in Spain is presented and different examples of old vacant slaughterhouses reused to accommodate libraries, offices, community centres, exhibition halls or sports centres, among others, are shown in the paper.
Resumo:
A number of short-to-mid height RC buildings with wide beams have been constructed in moderate-seismicity areas of Spain. The seismic behavior in the direction of the wide beams appears to be deficient because of low lateral strength, low ductility of the wide beams, big strut compressive forces inside the column-beam connections, and unreliable contribution of the spandrel zones of the wide beams. In the orthogonal direction, the behavior is worse since only the joists and the façade beams contribute to the lateral resistance. The objective is to assess the seismic capability of these structures; further research will involve proposing retrofit strategies. The research approach consists of selecting a number of representative buildings and evaluating their vulnerability by code-type, push-over and dynamic analyses. The cooperation of the masonry infill walls is accounted for. The main conclusion is that the seismic behavior of these buildings is inadequate in most of the situations.
Resumo:
One of the most significant aspects of a building?s acoustic behavior is the airborne sound insulation of the room façades, since this determines the protection of its inhabitants against environmental noise. For this reason, authorities in most countries have established in their acoustic regulations for buildings the minimum value of sound insulation that must be respected for façades. In order to verify compliance with legal requirements it is usual to perform acoustic measurements in the finished buildings and then compare the measurement results with the established limits. Since there is always a certain measurement uncertainty, this uncertainty must be calculated and taken into account in order to ensure compliance with specifications. The most commonly used method for measuring sound insulation on façades is the so-called Global Loudspeaker Method, specified in ISO 140-5:1998. This method uses a loudspeaker placed outside the building as a sound source. The loudspeaker directivity has a significant influence on the measurement results, and these results may change noticeably by choosing different loudspeakers, even though they all fulfill the directivity requirements of ISO 140-5. This work analyzes the influence of the loudspeaker directivity on the results of façade sound insulation measurement, and determines its contribution to measurement uncertainty. The theoretical analysis is experimentally validated by means of an intermediate precision test according to ISO 5725-3:1994, which compares the values of sound insulation obtained for a façade using various loudspeakers with different directivities. Keywords: Uncertainty, Façade, Insulation