830 resultados para Energia elétrica - Tarifas - Brasil


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the oil industry, natural gas is a vital component of the world energy supply and an important source of hydrocarbons. It is one of the cleanest, safest and most relevant of all energy sources, and helps to meet the world's growing demand for clean energy in the future. With the growing share of natural gas in the Brazil energy matrix, the main purpose of its use has been the supply of electricity by thermal power generation. In the current production process, as in a Natural Gas Processing Unit (NGPU), natural gas undergoes various separation units aimed at producing liquefied natural gas and fuel gas. The latter should be specified to meet the thermal machines specifications. In the case of remote wells, the process of absorption of heavy components aims the match of fuel gas application and thereby is an alternative to increase the energy matrix. Currently, due to the high demand for this raw gas, research and development techniques aimed at adjusting natural gas are studied. Conventional methods employed today, such as physical absorption, show good results. The objective of this dissertation is to evaluate the removal of heavy components of natural gas by absorption. In this research it was used as the absorbent octyl alcohol (1-octanol). The influence of temperature (5 and 40 °C) and flowrate (25 and 50 ml/min) on the absorption process was studied. Absorption capacity expressed by the amount absorbed and kinetic parameters, expressed by the mass transfer coefficient, were evaluated. As expected from the literature, it was observed that the absorption of heavy hydrocarbon fraction is favored by lowering the temperature. Moreover, both temperature and flowrate favors mass transfer (kinetic effect). The absorption kinetics for removal of heavy components was monitored by chromatographic analysis and the experimental results demonstrated a high percentage of recovery of heavy components. Furthermore, it was observed that the use of octyl alcohol as absorbent was feasible for the requested separation process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the progress of devices technology, generation and use of energy ways, power quality parameters start to influence more significantly the various kinds of power consumers. Currently, there are many types of devices that analyze power quality. However, there is a need to create devices, and perform measurements and calculate parameters, find flaws, suggest changes, and to support the management of the installation. In addition, you must ensure that such devices are accessible. To maintain this balance, one magnitude measuring method should be used which does not require great resources processing or memory. The work shows that application of the Goertzel algorithm, compared with the commonly used FFT allows measurements to be made using much less hardware resources, available memory space to implement management functions. The first point of the work is the research of troubles that are more common for low voltage consumers. Then we propose the functional diagram indicate what will be measured, calculated, what problems will be detected and that solutions can be found. Through the Goertzel algorithm simulation using Scilab, is possible to calculate frequency components of a distorted signal with satisfactory results. Finally, the prototype is assembled and tests are carried out by adjusting the parameters necessary for one to maintain a reliable device without increasing its cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação (Mestrado)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The search for mitigation solutions, with respect to the effects of overvoltages linked to the energization and reclosing maneuvers of transmission lines include a challenging subject with strong impact on the insulation coordination of electrical systems. Although the recognition of classical and commercial proposals to mitigate these phenomena, other possibilities are certainly still worthwhile highlighting and investigations. In this context, the present work is grounded in the exposure of the physical and mathematical foundations of a strategy based on controlled switchings, whose moments to the line reclosing are pre-programmed. The computational evaluation of the effectiveness of the methodology is made using the ATP simulator, which are studies in a typical electrical system subjected to the action of short-circuits fallowed by shutdowns and subsequent reclosing, under the action of technology here focused and lack thereof.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing demand in electricity and decrease forecast, increasingly, of fossil fuel reserves, as well as increasing environmental concern in the use of these have generated a concern about the quality of electricity generation, making it well welcome new investments in generation through alternative, clean and renewable sources. Distributed generation is one of the main solutions for the independent and selfsufficient generating systems, such as the sugarcane industry. This sector has grown considerably, contributing expressively in the production of electricity to the distribution networks. Faced with this situation, one of the main objectives of this study is to propose the implementation of an algorithm to detect islanding disturbances in the electrical system, characterized by situations of under- or overvoltage. The algorithm should also commonly quantize the time that the system was operating in these conditions, to check the possible consequences that will be caused in the electric power system. In order to achieve this it used the technique of wavelet multiresolution analysis (AMR) for detecting the generated disorders. The data obtained can be processed so as to be used for a possible predictive maintenance in the protection equipment of electrical network, since they are prone to damage on prolonged operation under abnormal conditions of frequency and voltage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper analyses the sustainability under the environmental (ecological) perspective of Water Supply and Sanitary Sewers Systems from Uberaba city, MG. It was accomplished in this analysis, An Environmental Sustainability Assessment of those systems, by the means of specific sustainability indicators proposed for Uberaba, but which may be used for other simi-lar cities. To the characterization of the systems, visitations were made to the main units as well as a documental was elaborated. The definition of the level or stage of the sustainability by the indicators was made based on a literature review, on interviews with the technicians and managers of the systems and based on the characterization and observation of the system reality, being attributed to them the following classification: Non Sustainable, Low Sustaina-bility, Medium Sustainability and High Sustainability. It was verified that the indicators that have lower compatibility to the process of sustainability to the studied systems are those rela-ted to the water physical losses, to the water per capita consumption, to the electricity con-sumption and to the sludge from the water treatment plants disposal untreated into a water body, for the Water Supply System. And those ones related to the attendance with sewage treatment, to the electricity consumption and to the usage of the treated sewage, for the Sani-tary Sewers, all of them classified as Non Sustainable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on the possibility of real-time interaction with three-dimensional environments through an advanced interface, Virtual Reality consist in the main technology of this work, used in the design of virtual environments based on real Hydroelectric Plants. Previous to the process of deploying a Virtual Reality System for operation, three-dimensional modeling and interactive scenes settings are very importante steps. However, due to its magnitude and complexity, power plants virtual environments generation, currently, presents high computing cost. This work aims to present a methodology to optimize the production process of virtual environments associated with real hydroelectric power plants. In partnership with electric utility CEMIG, several HPPs were used in the scope of this work. During the modeling of each one of them, the techiniques within the methodologie were addressed. After the evaluation of the computional techniques presented here, it was possible to confirm a reduction in the time required to deliver each hydroelectrical complex. Thus, this work presents the current scenario about development of virtual hydroelectric power plants and discusses the proposed methodology that seeks to optimize this process in the electricity generation sector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Informação Geográfica (SIG) ao estudo das energias renováveis, tendo como caso avaliar o potencial solar na ilha de São Vicente do arquipélago de Cabo Verde. A energia do sol é a principal fonte de energia renovável, e está disponível em quase todas as regiões do planeta. Quantificar o potencial energético solar de um lugar ou região é indispensável, para avaliar as potencialidades de produção de energia fotovoltaica. Outro fator importante prende-se com ordenamento territorial associado à exploração desses recursos energéticos, pelo que devem ser avaliadas as condições técnicas, ambientais e económicas, quando se pretende instalar parques para a produção de energia fotovoltaica. Assim, neste trabalho foram aplicadas as ferramentas SIG, para quantificar a radiação solar mensal e anual da ilha de São Vicente, arquipélago de Cabo Verde, através do modelo Solar Analyst. Numa segunda fase, aplicou-se a técnica de análise multicritério em combinação com os SIGs para definir as áreas mais favoráveis para a instalação de parques de produção de energia elétrica a partir da energia solar. Para o cálculo da radiação solar na ilha de São de Vicente, utilizou-se o modelo digital de terreno (MDT) e a latitude da ilha como parâmetros de entrada ao modelo. Para a análise multicritério definiram-se um conjunto de critérios que devem ser considerados na implementação de parques solares, nomeadamente, a disponibilidade de radiação solar existente na área, a distância à rede de transporte de energia elétrica e à rede viária, o declive do terreno, o uso e ocupação do solo e a proximidade às linhas de água. Para auxiliar na atribuição dos pesos aos critérios utilizados na análise aplicou-se a método Analytic Hierarchy Process (AHP). As áreas resultantes do processo da análise multicritério, foram confrontadas com a Carta de Condicionantes do esquema regional de ordenamento da ilha de São Vicente, aferindo a conformidade das propostas e reajustes subsequentes, de modo a obter os resultados finais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Sociedade da Água de Luso, S.A., localizada no concelho de Mealhada, é uma empresa do setor do engarrafamento de águas minerais naturais, de nascente e de consumo humano. Esta realiza as suas atividades, tendo em consideração a eficiência energética, ao longo do seu processo produtivo. Desta forma, o trabalho desenvolvido teve como objetivo o acompanhamento da implementação do sistema de monitorização e recolha de dados, que posteriormente foi útil na redução dos consumos energéticos (consumo de ar comprimido). Para além disto, também foi proposta uma medida de eficiência energética que visa a redução de energia elétrica na área da iluminação. O sistema de monitorização e recolha de dados e a criação de uma equipa de redução do consumo de ar comprimido permitiram a identificação das áreas de atuação, a monitorização das metas estipuladas no âmbito da equipa e a detecção de anomalias. A medida de eficiência energética aplicada incide na substituição de lâmpadas fluorescentes tubulares T8 por lâmpadas fluorescentes tubulares T5. Assim, a implementação deste sistema e a aplicação das medidas de eficiência energética na rede de ar comprimido no âmbito da equipa permitiram uma redução de 0,03 kWh/hL o que significa uma poupança de 5.600 € em quinze semanas. Ao nível da iluminação as medidas sugeridas permitem uma redução de 8.945 kWh/ano o que corresponde a uma poupança de 1.055 €/ano.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the development and modification of techniques to reduce the effects of load variation and mains frequency deviation in repetitive controllers applied to active power filters. To minimize the effects of aperiodic signals resulting from the connection or disconnection of non-linear loads is developed a technique which recognizes linear and nonlinear loads, and operates to reset the controller only when the error due to the transition of considerable value, and the transition is from non-linear to linear load. An algorithm to adapt the gain of the repetitive controller, based on a sigmoid function adaptation, in order to minimize the effects caused by random noise in the measurement system is also used. This work also analyzes the effects of frequency variation and presents the main methods to cope with this situation. Some solutions are the change in the number of samples per period and the variation of the sampling rate. The first has the advantage of using linear design techniques and results in a time invariant system. The second method changes the sampling frequency and leads to a time variant system that demands a difficult analysis of stability. The proposed algorithms were tested using the methods of truncation of the number of samples and the method of changing the sampling rate of the system to compensate possible frequency variations of the grid. Experimental results are presented to validate the proposal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electric power systems are getting more complex and covering larger areas day by day. This fact has been contribuiting to the development of monitoring techniques that aim to help the analysis, control and planning of power systems. Supervisory Control and Data Acquisition (SCADA) systems, Wide Area Measurement Systems and disturbance record systems. Unlike SCADA and WAMS, disturbance record systems are mainly used for offilne analysis in occurrences where a fault resulted in tripping of and apparatus such as a transimission line, transformer, generator and so on. The device responsible for record the disturbances is called Digital Fault Recorder (DFR) and records, basically, electrical quantities as voltage and currents and also, records digital information from protection system devices. Generally, in power plants, all the DFRs data are centralized in the utility data centre and it results in an excess of data that difficults the task of analysis by the specialist engineers. This dissertation shows a new methodology for automated analysis of disturbances in power plants. A fuzzy reasoning system is proposed to deal with the data from the DFRs. The objective of the system is to help the engineer resposnible for the analysis of the DFRs’s information by means of a pre-classification of data. For that, the fuzzy system is responsible for generating unit operational state diagnosis and fault classification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The focus of this work is the automatic analysis of disturbance records for electrical power generating units. The main proposition is a method based on wavelet transform applied to short-term disturbance records (waveform records). The goal of the method is to detect the time instants of recorded disturbances and extract meaningful information that characterize the faults. The result is a set of representative information of the monitored signals in power generators. This information can be further classified by an expert system (or other classification method) in order to classify the faults and other abnormal operating conditions. The large amount of data produced by digital fault recorders during faults justify the research of methods to assist the analysts in their task of analysing the disturbances. The literature review pointed out the state of the art and possible applications for oscillography records. The review of the COMTRADE standard and wavelet transform underlines the choice of the method for solving the problem. The conducted tests lead to the determination of the best mother wavelet for the segmentation process. The application of the proposed method to five case studies with real oscillographic records confirmed the accuracy and efficiency of the proposed scheme. With this research, the post-operation analysis of occurrences is improved and as a direct result is the reduction of the time that generators are offline.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a low cost architecture for development of synchronized phasor measurement units (PMU). The device is intended to be connected in the low voltage grid, which allows the monitoring of transmission and distribution networks. Developments of this project include a complete PMU, with instrumentation module for use in low voltage network, GPS module to provide the sync signal and time stamp for the measures, processing unit with the acquisition system, phasor estimation and formatting data according to the standard and finally, communication module for data transmission. For the development and evaluation of the performance of this PMU, it was developed a set of applications in LabVIEW environment with specific features that let analyze the behavior of the measures and identify the sources of error of the PMU, as well as to apply all the tests proposed by the standard. The first application, useful for the development of instrumentation, consists of a function generator integrated with an oscilloscope, which allows the generation and acquisition of signals synchronously, in addition to the handling of samples. The second and main, is the test platform, with capabality of generating all tests provided by the synchronized phasor measurement standard IEEE C37.118.1, allowing store data or make the analysis of the measurements in real time. Finally, a third application was developed to evaluate the results of the tests and generate calibration curves to adjust the PMU. The results include all the tests proposed by synchrophasors standard and an additional test that evaluates the impact of noise. Moreover, through two prototypes connected to the electrical installation of consumers in same distribution circuit, it was obtained monitoring records that allowed the identification of loads in consumer and power quality analysis, beyond the event detection at the distribution and transmission levels.