916 resultados para Endometrial cavity
Resumo:
Mode of access: Internet.
Resumo:
"Department of the Navy. Bureau of Ships. Contract Nonr-220 (12)."
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
We consider the effect of quantum interference on population distribution and photon statistics of a cavity field interacting with dressed states of a strongly driven three-level atom. We analyse three coupling configurations of the cavity field to the driven atom, with the cavity frequency tuned to the outer Rabi sideband, the inner Rabi sideband and the central frequency of the 'singly dressed' three-level atom. The quantum doubly dressed states for each configuration are identified and the population distribution and photon statistics are interpreted in terms of transitions among these dressed states and their populations. We find that the population distribution depends strongly on quantum interference and the cavity damping. For the cavity field tuned to the outer or inner Rabi sidebands the cavity damping induces transitions between the dressed states which are forbidden for the ordinary spontaneous emission. Moreover, we find that in the case of the cavity field coupled to the inner Rabi sideband the population distribution is almost Poissonian with a large average number of photons that can be controlled by quantum interference. This system can be considered as a one-atom dressed-state laser with controlled intensity.
Resumo:
A semiconductor based scheme has been proposed for generating entangled photon pairs from the radiative decay of an electrically pumped biexciton in a quantum dot. Symmetric dots produce polarization entanglement, but experimentally realized asymmetric dots produce photons entangled in both polarization and frequency. In this work, we investigate the possibility of erasing the “which-path” information contained in the frequencies of the photons produced by asymmetric quantum dots to recover polarization-entangled photons. We consider a biexciton with nondegenerate intermediate excitonic states in a leaky optical cavity with pairs of degenerate cavity modes close to the nondegenerate exciton transition frequencies. An open quantum system approach is used to compute the polarization entanglement of the two-photon state after it escapes from the cavity, measured by the visibility of two-photon interference fringes. We explicitly relate the two-photon visibility to the degree of the Bell-inequality violation, deriving a threshold at which Bell-inequality violations will be observed. Our results show that an ideal cavity will produce maximally polarization-entangled photon pairs, and even a nonideal cavity will produce partially entangled photon pairs capable of violating a Bell-inequality.
Resumo:
Aims The major aims of the study were to compare the safety of a continuous low-dose estradiol-releasing vaginal ring (ESTring) to that of a vaginal estradiol tablet (Vagifem®) on the endometrium and the relief of subjective symptoms and signs of urogenital estrogen deficiency. Quality of life and acceptability of treatment delivery were also assessed. Study design A prospective, randomized study in which women were assigned in a 2: 1 ratio to ESTring and Vagifem and followed for 12 months. The primary endpoint was endometrial safety, based on the results of ultrasound measurement of endometrial thickness and a progestogen challenge test at baseline and week 48. Efficacy was determined by subjective assessment of urogenital estrogen deficiency symptoms at baseline and weeks 3, 12, 24, 36 and 48 and assessment of signs of vaginal epithelial atrophy by the clinician at baseline, 12 and 48 weeks. In addition, pelvic floor strength, vaginal cytological evaluation and pH, bacteruria and patient acceptability were assessed. Quality of life was assessed using a menopause-specific quality-of-life questionnire and a 2-day bladder diary at baseline and 12 and 48 weeks. The comparability of the two groups was assessed using ANOVA, χ(2) or Fisher's exact tests. Results A total of 126 women were randomized to ESTring and 59 to Vagifem. There was no statistical difference between the groups in the alleviation of symptoms and signs of urogenital estrogen deficiency. Maturation indices increased in both groups, from generally atrophic at baseline to proliferative or highly proliferative at 48 weeks. After 48 weeks of treatment, there was no statistically significant difference in endometrial thickness between the two groups. A statistically smaller proportion of bleeding/spotting occurred in the ESTring group (n = 0) compared to the Vagifem users (n = 4). Estradiol and total estrone serum levels increased during treatment in both groups but remained within the normal postmenopausal range. General health status in both groups was unchanged but the urogenital component of health burden was significantly improved in both groups. Bladder diary variables showed no differences between treatment groups. Conclusion Equivalent endometrial safety and efficacy in the relief of the symptoms and signs of urogenital estrogen deficiency were demonstrated for the 12 months' use of a low-dose estradiol-releasing vaginal ring and a vaginal estradiol tablet.
Resumo:
In order to determine the age of adult wild dogs, we compared two methods ( that of Thomson and Rose (TR method) and that of Knowlton and Whittemore (KW method)) of measuring and calculating pulp cavity : tooth width ratios on upper and lower canine teeth from 68 mixed-sex, known-age wild dogs of 9 months to 13 years of age reared at two localities. Although significant relationships ( P = 0.0001) were found between age and pulp cavity ratios by both methods, the TR ratio calculation and measurement showed heteroscedasity in error variance whereas the KW ratios had a more stable error variance and were normally distributed. The KW method also found significant differences between pulp cavity ratios between teeth of the upper and lower jaws ( P < 0.0001) and sex ( P = 0.01) but not geographic origin ( P = 0.1). Regressions and formulae for fitted curves are presented separately for male and female wild dogs. Males show greater variability in pulp cavity decrements with age than do females, suggesting a physiological difference between the sexes. We conclude that the KW method of using pulp cavity as a proportion of tooth width, measured 15 mm from the root tip and averaged over both upper canines, is the more accurate method of estimating the age of adult wild dogs.
Resumo:
Follicular dendritic cell sarcoma (FDCS) is a rare intermediate grade malignant neoplasm of reticular dendritic origin. Castleman’s disease (CD) represents a non-neoplastic lymphoproliferative disorder with various clinical and morphological features. FDCS has been reported to be associated with CD. In this article, we describe the first case of follicular dendritic cell sarcoma associated with Castleman’s disease presenting in the oral cavity. Copyright © 2005 Elsevier Ltd All rights reserved.
Resumo:
We report on the effect of the replacement of the conventional ITO anode with the semitransparent metallic material on the performance of microcavity OLEDs. We performed comprehensive simulations of the emission from microcavity OLEDs consisting of widely used organic materials, N,N′-di(naphthalene-1- yl)-N,N′-diphenylbenzidine (NPB) as a hole transport layer and tris (8-hydroxyquinoline) (Alq3) as emitting and electron transporting layer. Silver and LiF/Al were considered as a cathode, while metallic (Au and Ag) anode was used and simulations were performed on devices with both the metallic and conventional ITO anode. The electroluminescence emission spectra, electric field distribution inside the device, carrier density, recombination rate and exciton density were calculated as a function of the position of the emission layer. The results show that the metallic anode enhances light output and that optimum emission from a microcavity OLED is achieved when the position of the recombination region is aligned with the antinode of the standing wave inside the cavity. The microcavity OLED devices with Ag/Ag and Ag/Au mirrors were fabricated and characterized. The experimental results have been compared to the simulations and the influence of the different anode, emission region width and position on the performance of microcavity OLEDs was discussed.