900 resultados para Difference method for differences


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The active electrogenic absorption of glucose was studied in 12 niacin deficient rats using a method for measuring changes in transmural potential difference across jejunal mucosa. The glucose was infused in 6 different concentrations (2.5; 5.0; 10.0; 20.0; 50.0 and 100.0 mM/L) at a constant rate of 1.7 ml per minute. The apparent kinetic parameters (Km and Pdmax) of active electrogenic transport were obtained graphically from curves of glucose transfer potentials. The results were compared with that obtained in a control group. The curve of glucose transfer potential in niacin deficient group was significantly lower than that of the control group. The apparent Km of niacin deficient group was greater than in the control group (16.1 x 12.7 mM/L). Furthermore, the Pdmax of the deficient group was lower than that of the control group (12.5 x 19.4 mV). The results showed that in niacin deficiency occurs a decreasing of the active electrogenic glucose absorption. One of the possible interpretation of the differences in the kinetic characteristics of electrogenic glucose transport would be a depleted energy supplement for the active transport in the enterocyte of the niacin deficient rats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the antihypertensive efficacy and safety of cilazapril compared to nifedipine retard in mild to moderate hypertension. Methods: Forty randomized out-patients with mild moderate hypertension, diastolic pressure (DP) between 95 and 115 mmg/Hg, with placebo for 15 days were randomized and allocated for treatment, double-blind, once daily with cilazapril 2.5 mg (n = 20) or nifedipine retard 20 mg (20 = n) for four weeks. The non-responders (DP > 90 mmHg) had the dosage increased twice, b.i.d., while responders were maintained up to 10 weeks. Clinical visits were performed before, at baseline and every two weeks and the laboratory test was performed after placebo run-in, 4th and 10th weeks of treatment. Results: The blood pressure (BP) were similar between groups at the end of the placebo (cilazapril 151 ± 14/103 ± 5 - nifedipine 157 ± 17/108 ± 7 mmHg, p > 0.05). DP decreased already at second weeks (cilazapril 95 ± 9 - nifedipine 96 ± 11 mmHg, p < 0.05, compared to week 0) in both groups at the end of study with no differences inter groups. BP normalization was obtained in 58% of the patients with cilazapril and in 61% in the nifedipine group. Adverse biochemical effects were not observed in any group. Six (16%) patients of the cilazapril and 15 (39%) of nifedipine related collateral events, although no difference were observed between groups. Conclusion: Cilazapril 2.5 to 5 mg normalized BP in 58% of mild and moderate hypertension patients, and this efficacy was similar to sustained-release nifedipine 20 to 40 mg. Cilazapril had no adverse effects on the biochemical parameters with low incidence of collateral effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The absence of natural enemies often allows exotic pests to reach densities that are much higher than normally occur in their native habitats. When Solenopsis fire ants were introduced into the United States, their numerous natural enemies were left behind in South America. To compare intercontinental fire ant densities, we selected 13 areas in South America and another 12 areas in North America. Sample areas were paired with weather stations and distributed across a broad range of climatic conditions. In each area, we measured fire ant densities at 5 preselected roadside sites that were at least 5 km apart. At each site, we also measured foraging activity, checked for polygyne colonies, and recorded various kinds of environmental data. In most areas, we also measured fire ant densities in lawns and grazing land. Fire ant populations along roadsides in North America were 4-7 times higher than fire ant populations in South America. Similar intercontinental differences were found in lawns and on grazing lands. These intercontinental differences in fire ant abundance were not associated with sampling conditions, seasonal variability, habitat differences, or the frequency of polygyny. Although several correlations were found with long-term weather conditions, careful inspection of the data suggests that these correlations were probably more coincidental than causal. Cultural differences in roadside maintenance may explain some of the intercontinental differences in fire ant abundance, but they did not account for equivalent intercontinental differences in grazing land and mowed lawns. Bait tests showed that competition with other ants was much more important in South America; however, we were not able to determine whether this was a major cause of intercontinental differences or largely a consequence of other factors such as the numerous pathogens and parasites that are found in South America. Because this study was correlational, we were unable to determine the cause(s) of the large intercontinental difference in fire ant abundance that we observed. However, we were able to largely exclude a number of possible explanations for the differences, including sampling, season, polygyny, climate, and aspects of habitat. By a process of elimination, escape from natural enemies remains among the most likely explanations for the unusually high densities of fire ants found in North America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the effect of erbium:yttrium-aluminum-garnet laser instrumentation of root surfaces on the morphology of fibroblasts from continuous lineage. Method and materials: Dentinal slices with 4 mm2 of surface area were obtained from teeth extracted for severe periodontal involvement. Specimens were assigned to one of three treatment groups: group 1, application of the laser with an energy level of 250 mJ at 103 pulses per second; group 2, application of the laser with an energy level of 80 mJ at 166 pulses per second; and group 3, similar to group 2, but with concomitant water irrigation of the device. The specimens were incubated in multiwell plates containing cell culture media. After 24 hours, the specimens were submitted to routine preparation for scanning electron microscopy. Three independent and blind examiners used photomicrographs to evaluate the morphology of the fibroblasts: 0 = without cells; 1 = flat cells; 2 = round cells; and 3 = combination of round and flat cells. Results: Statistical analysis indicated that there were significant differences among treatment groups and that group 3 was significantly different from groups 1 and 2. Conclusion: There was no difference between groups 1 and 2 in the morphology of fibroblasts. Laser instrumentation with concomitant irrigation impaired the adhesion of fibroblasts to dentinal surfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigated the effect of different microwave curing cycles on the changes in occlusal vertical dimension of complete dentures. Four test groups with 12 maxillary dentures each were evaluated. Groups 1, 2 and 3 were polymerized with different cycles by microwave radiation and Group 4 was the control and cured by water bath. The average pin opening for all groups was less than 0.5 mm. There was no significant difference between the groups polymerized by the microwave method and the control group. However, analyses of the vertical dimension changes showed statistically significant differences between groups 2 (0.276 +/- 0.141 mm) and 3 (0.496 +/- 0.220 mm).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study measured the water flow commonly used in high-speed handpieces to evaluate the water flow's influence on temperature generation. Different flow speeds were evaluated between turbines that had different numbers of cooling apertures. Method and materials: Two water samples were collected from each high-speed handpiece at private practices and at the School of Dentistry at São José dos Campos. The first sample was collected at the customary flow and the second was collected with the terminal opened for maximum flow. The two samples were collected into weighed glass receptacles after 15 seconds of turbine operation. The glass receptacles were reweighed and the difference between weights was recorded to calculate the water flow in mL/min and for further statistical analysis. Results: The average water flow for 137 samples was 29.48 mL/min. The flow speeds obtained were 42.38 mL/min for turbines with one coolant aperture; 34.31 mL/min for turbines with two coolant apertures; and 30.44 mL/min for turbines with three coolant apertures. There were statistical differences between turbines with one and three coolant apertures (Tukey-Kramer multiple comparisons test with P < .05). Conclusion: Turbine handpieces with one cooling aperture distributed more water for the burs than high-speed handpieces with more than one aperture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of cavity design and photocuring method on the marginal seal of resin composite restorations. METHOD AND MATERIALS: Seventy-two bovine teeth were divided into 2 groups: group 1 received box-type cavity preparations, and group 2 received plate-type preparations. Each group was divided into 3 subgroups. After etching and bonding, Z250 resin composite (3M Espe) was applied in 2 equal increments and cured with 1 of 3 techniques: (1) conventional curing for 30 seconds at 650 mW/cm2; (2) 2-step photocuring, in which the first step was performed 14 mm from the restoration for 10 seconds at 180 mW/cm2 and the second step was performed in direct contact for 20 seconds at 650 mW/cm2; or (3) progressive curing using Jetlite 4000 (J. Morita) for 8 seconds at 125 mW/cm2 and then 22 seconds at 125 mW/cm2 up to 500 mW/cm2. The specimens were thermocycled for 500 cycles and then submitted to dye penetration with a 50% silver nitrate solution. Microleakage was assessed using a stereomicroscope. Data were analyzed using analysis of variance and Tukey test (5% level of significance). RESULTS: A statistically significant difference was found between groups when a double interaction between photocuring and cavity preparation was considered (P = .029). CONCLUSIONS: No one type of cavity preparation or photocuring method prevented micro-leakage. The plate-type preparation showed the worst dye penetration when conventional and progressive photocuring methods were used. The best results were found using the 2-step photocuring with the plate-type preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A cross-sectional microhardness (CSMH) test was carried out in human dental enamel exposed to a demineralizing solution in order to evaluate two different times of indentation in sound tissue and artificially induced caries. Twenty caries-free extracted human molars had one of their smooth surfaces sectioned and the enamel surface was isolated with nail polish except for an area of 6 mm2. These specimens were submitted to artificially induced enamel caries on a lactate buffer containing 0.1 ppm fluoride (F) during 28 days. All specimens were bisected to create groups A and B in which CSMH test was performed employing a Knoop indenter with a 25g load for 5 or 10 s, respectively. Student's paired t-test (p<0.05) was used to determine statistically significant differences between group A and B in 7 depths. There were no significant differences between any of the analyzed depths. Since the present experiment showed no significant difference when comparing indentations made with a 25 g load during either 5 or 10 s in different depths, this method can be used with either one of the time intervals tested without compromising a CSMH test on artificially demineralized human enamel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of polymerization cycle and thickness of maxillary complete denture bases on the porosity of acrylic resin. Materials and Methods: Two heat-activated denture base resins - one conventional (Clássico) and one designed for microwave polymerization (Onda-Cryl) - were used. Four groups were established, according to polymerization cycles: A (Onda-Cryl, short microwave cycle), B (Onda-Cryl, long microwave cycle), C (Onda-Cryl, manufacturing microwave cycle), and T (Clássico, water bath). Porosity was evaluated for different thicknesses (2.0, 3.5, and 5.0 mm; thicknesses I, II, and III, respectively) by measurement of the specimen volume before and after its immersion in water. The percent porosity data were submitted to Kruskal-Wallis for comparison among the groups. Results: The Kruskal-Wallis test detected that the combinations of the different cycles and thicknesses showed significant differences, and the mean ranks of percent porosity showed differences only in the thinnest (2.0 mm) microwave-polymerized specimens (A = 53.55, B = 40.80, and C = 90.70). Thickness did not affect the results for cycle T (I = 96.15, II = 70.20, and III = 82.70), because porosity values were similar in the three thicknesses. Conclusions: Microwave polymerization cycles and the specimen thickness of acrylic resin influenced porosity. Porosity differences were not observed in the polymerized resin bases in the water bath cycle for any thickness. © 2007 by The American College of Prosthodontists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To ensure high accuracy results from GPS relative positioning, the multipath effects have to be mitigated. Although the careful selection of antenna site and the use of especial antennas and receivers can minimize multipath, it cannot always be eliminated and frequently the residual multipath disturbance remains as the major error in GPS results. The high-frequency multipath from large delays can be attenuated by double difference (DD) denoising methods. But the low-frequency multipath from short delays is very difficult to be reduced or modeled. In this paper, it is proposed a method based on wavelet regression (WR), which can effectively detect and reduce the low-frequency multipath. The wavelet technique is firstly applied to decompose the DD residuals into the low-frequency bias and high-frequency noise components. The extracted bias components by WR are then directly applied to the DD observations to correct them from the trend. The remaining terms, largely characterized by the high-frequency measurement noise, are expected to give the best linear unbiased solutions from a least-squares (LS) adjustment. An experiment was carried out using objects placed close to the receiver antenna to cause, mainly, low-frequency multipath. The data were collected for two days to verify the multipath repeatability. The ground truth coordinates were computed with data collected in the absence of the reflector objects. The coordinates and ambiguity solution were compared with and without the multipath mitigation using WR. After mitigating the multipath, ambiguity resolution became more reliable and the coordinates were more accurate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Creatine kinase (CK) and aspartate aminotransferase (AST) are mainly muscle-specific enzymes, which can be associated with muscle tissue damage. The aim of this study was to assess the activities of CK and AST during the postoperative period, after conventional (G1) and videolaparoscopic ovariectomy (G2), in queens. A further group (G3) was subjected to anaesthesia only. Results demonstrate that there were significant differences between groups. The highest levels of CK were recorded in Gl, however at a confidence level of p < 0.05 there was no significant difference between groups during the first 6 hours after surgery. A significant (p < 0.05) increase of CK values was identified between 0h and 3h in both groups (Gl and G2). Regarding AST activity there was no significant variation between groups, but again there was a significant difference between values at 0h and 3h after surgery. In conclusion, ovariectomy performed by videolap-aroscopy seems to cause less muscle damage when compared to the conventional method. © 2009 by Verlag Hans Huber, Hogrefe AG, Bem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prosthetic eyes are artificial substitutes for the eyeball, made of heat-curing acrylic resin, serving to improve the esthetic appearance of the mutilated patient and his/her inclusion in society. The aim of this study was to assess the flexural strength of two heat-curing acrylic resins used for manufacturing prosthetic eyes. Thirty-six specimens measuring 64 x 10 x 3.3 mm were obtained and divided into four groups: acrylic resin for artificial sclera N1 (Artigos Odontológicos Clássico, São Paulo, SP, Brazil), heat-cure water technique (GI) and microwave-cured (GII); colorless acrylic resin for prosthetic eyes (Artigos Odontológicos Clássico, São Paulo, SP, Brazil), heat-cure water technique (GIII) and microwave-cured (GIV). Mechanical tests using three point loads were performed in a test machine (EMIC, São José dos Pinhais, PR, Brazil). The analysis of variance and the Tukey test were used to identify significant differences (p < 0.01). Groups GII and GIV presented, respectively, the highest (98.70 ± 11.90 MPa) and lowest means (71.07 ± 8.93 MPa), with a statistically significant difference. The cure method used for the prosthetic eye resins did not interfere in their flexural strength. It was concluded that all the resins assessed presented sufficient flexural strength values to be recommended for the manufacture of prosthetic eyes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: The aim of the study was to assess the accuracy of a new intraoral paralleling device for creating proximal guiding planes for removable partial dental prostheses. Methods and Materials: Thirty gypsum casts were divided into two groups in which the proximal surfaces of selected teeth were prepared using either a surveying device (Group 1) or the new ParalAB paralleling device (Group 2). In each cast guiding planes were prepared on the distal surface of the maxillary left canine (A), on the mesial and distal surfaces of the maxillary left second molar (B and C), and on the distal surface of the maxillary right canine (D). Each prepared surface formed an angle related to the occlusal plane that was measured five times and averaged by one operator using a tridimensional coordinate machine. Results: The mean guiding plane angles (± standard deviation) for the prepared surfaces were A=91.82° (±0.48°, B=90.47° (±0.47°, C=90.21° (±0.76°, and D=90.50° (±0.73°) for the dental surveyor (Group 1) and A=92.18° (±0.87°), B=90.90° (±0.85°), C=90.07° (±0.92°), and D=90.66° (±0.76°) for the ParalAB paralleling device (Group 2). A two-way ANOVA, Tukey's, and Levène's tests (at p<0.05) revealed statistically significant differences among surfaces prepared by both groups and that one surface Conclusions: The ParalAB device was able to prepare parallel surfaces and despite significant difference between groups, the ParalAB presented a small deviation from absolute parallelism and can be considered a valid method to transfer guide plans in the fabrication of removable partial dentures. Clinical Significance: The preparation of suitable guiding planes on abutment teeth during the fabrication of removable partial dentures is dependent on the ability of the operator and requires considerable chair time. When multiple teeth are involved, achieving parallelism between abutment surfaces can be technically challenging, especially in posterior regions of the mouth. The ParalAB prototype intraoral paralleling device can aid the clinician during the preparation of accurate guiding planes with a minimum degree of occlusal divergence. © 2010 Seer Publishing LLC.