959 resultados para Diagnostic Test Accuracy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to use systematic teaching in a clinical setting using software to teach reading and writing in one boy with learning difficulties and obtain accurate performance in dictation. In the pre-test, the student showed good performance in matching-to-sample tasks (96% in matching printed words to dictated words; 88% in matching pictures to dictated words), although he obtained a low percentage of correct answers in the dictation of constructed responses (52%) and manuscripts (24%). The teaching strengthened the selection of printed words matched to dictated words and copying words. The student obtained 100% correct answers in the teaching tasks. In post-tests of dictation, he obtained 100% correct answers in constructed response and 96% correct answers in manuscripts. The results indicate that carefully teaching copying may promote accuracy in the performance of responding to minimal units in dictation tasks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the accuracy of the depth of carious lesions on bitewing radiographs. Methods Recently extracted primary molars had their proximal surfaces evaluated visually (EC) and classified as healthy surface (0), signs that suggest the presence of carious lesions in enamel (1), signs of a superficial lesion in dentin (2) and carious lesions in deep dentin (3). Results The results were obtained by consensus between the investigators. The gold standard was determined by histological analysis. The values of sensitivity, specificity, accuracy and area under the ROC (Receiver Operating Characteristic) curve were evaluated. There was equilibrium between sensitivity (76.92% EC and 88.46% ER) and specificity (95.83% EC and 95.83% ER). Accuracy was 86.01% (EC) and 88.46% (ER). The Spearman correlation test was used to prove the correlation between clinical and radiographic examinations (0.886), for clinical and histological (0.736) and for radiographic and histological analysis (0.843).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this clinical study was to evaluate and compare the performance of visual exam with use of the Nyvad criteria (visual examination - (VE)), interproximal radiography (BW), laser fluorescence device (DIAGNOdent Pen-DDPen), and their association in the diagnosis of proximal lesions in primary teeth. For this purpose, 45 children (n = 59 surfaces) of both sexes, aged between 5 and 9 years were selected, who presented healthy primary molars or primary molars with signs suggestive of the presence of caries lesions. The surfaces were clinically evaluated and coded according to the Nyvad criteria and immediately afterwards with the DDPen. Radiographic exam was performed only on the surfaces coded with Nyvad scores 2, 3, 5, or 6. Active caries lesions and/or those with discontinuous surfaces were restored, considering the depth of lesion as reference standard. Sensitivity, specificity, accuracy, and area under ROC curve were calculated for each technique and its associations. Visual exam with Nyvad criteria presented the highest specificity, accuracy, and area under ROC curve values. The DDPen presented the highest sensitivity values. Association with one or more methods resulted in an increase in specificity. The performance of visual, radiographic, and DDpen exams and their associations were good; however, the clinical examination with the Nyvad criteria was sufficient for the diagnosis of interproximal lesions in primary teeth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Fisioterapia - FCT

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Objective: To evaluate the diagnostic accuracy of transvaginal ultrasound and office hysteroscopy in the differentiation between endometrial polyps and endometrial adenocarcinoma. Design: This is a prospective 100 women longitudinal study, 24 to 80 years, submitted to hysteroscopic polypectomy (n = 80) or surgery due to endometrial adenocarcinoma (n = 20), from january 2010 to December 2011. Clinical, ultrasonographic and hysteroscopic parameters were analyzed and compared with histopathologic find. Statistical analysis were performed utilizing the Tukey, Kruskal-Wallis, Dunn and Mann-Whitney test, with a confidence interval of 95% and p\0, 05 statiscally significant. Setting: Botucatu Medical School. Intervention: Prospective analysis of clinical, ultrasonographic and hysteroscopic parameters in patients with diagnosis suspected of endometrial polyps and adenocarcinoma of endometrium were performed. According to the diagnosis, hysteroscopic polypectomy or pan hysterectomy with lymph node sampling was realized. After the surgery and histopathological study, statistical analysis of parameters was performed and the results were compared between groups. It was Research Ethics Committee approved. Measurements and Main Results: There were no differences between age, BMI, menopause, TH use and associated diseases among groups. The main symptom of endometrial cancer was the postmenopausal bleeding, affecting 84,2% of women against 34,8% of polypectomy group. The majority of women with endometrial polyps were asymptomatic. Transvaginal ultrasonography showed no ability to differentiate cases of endometrial cancer compared with the cases of endometrial polyps, considering the presence of endometrial thickness and blood flow on color Doppler. Office hysteroscopy showed significant changes in 75% of the adenocarcinoma cases, especially the presence of diffuse hypervascularity with atypical vessels. Conclusion: Still remains an inability to establish clinical parameters and reliable ultrasound imaging to differentiate endometrial polyps and cancer of endometrium. Attention should be given to hysteroscopic exams presenting diffuse endometrial hypervascularization with architectural distortion of the vessels. The recommendation of our service remains the systematic removal of all endometrial polyps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mainstay of tuberculosis diagnosis in cattle and deer has been the tuberculin skin test. Recent advances have allowed the incorporation of blood based assays to the diagnostic arsenal for both cattle and deer. Use of defined and specific antigens has allowed for improved specificity of cell mediated assays in both cattle and deer and advances in antibody tests for tuberculosis have potential for use in free-ranging and captive cervid populations. Combined use of blood-based assays with skin testing will require further understanding of the effect of skin testing on the accuracy of blood based assays. Models of experimental infection of cattle have allowed for increased understanding of natural disease pathogenesis. Differences likely exist; however, between cattle and deer in both disease distribution and primary route of inoculation in naturally infected animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to examine the reliability, validity and classification accuracy of the South Oaks Gambling Screen (SOGS) in a sample of the Brazilian population. Participants in this study were drawn from three sources: 71 men and women from the general population interviewed at a metropolitan train station; 116 men and women encountered at a bingo venue; and 54 men and women undergoing treatment for gambling. The SOGS and a DSM-IV-based instrument were applied by trained researchers. The internal consistency of the SOGS was 0.75 according to the Cronbach`s alpha model, and construct validity was good. A significant difference among groups was demonstrated by ANOVA (F ((2.238)) = 221.3, P < 0.001). The SOGS items and DSM-IV symptoms were highly correlated (r = 0.854, P < 0.01). The SOGS also presented satisfactory psychometric properties: sensitivity (100), specificity (74.7), positive predictive rate (60.7), negative predictive rate (100) and misclassification rate (0.18). However, a cut-off score of eight improved classification accuracy and reduced the rate of false positives: sensitivity (95.4), specificity (89.8), positive predictive rate (78.5), negative predictive rate (98) and misclassification rate (0.09). Thus, the SOGS was found to be reliable and valid in the Brazilian population.